var-202310-1699
Vulnerability from variot
FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol. Rockwell Automation Provided by FactoryTalk Linx The following vulnerabilities exist in. It was * Inappropriate input confirmation (CWE-20) - CVE-2023-29464If the vulnerability is exploited, it may be affected as follows. It was * Information may be obtained by a remote third party via a specially crafted packet, or a denial of service (denial of service) may be attempted. DoS ) state. This product is mainly used for communication between small applications and large automation systems
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202310-1699", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "factorytalk linx", "scope": "eq", "trust": 1.0, "vendor": "rockwellautomation", "version": "6.30" }, { "model": "factorytalk linx", "scope": "eq", "trust": 1.0, "vendor": "rockwellautomation", "version": "6.20" }, { "model": "factorytalk linx", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": null }, { "model": "factorytalk linx", "scope": "lte", "trust": 0.8, "vendor": "rockwell automation", "version": "v6.20 and earlier s" }, { "model": "automation factorytalk linx", "scope": "lte", "trust": 0.6, "vendor": "rockwell", "version": "\u003c=6.20" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-78312" }, { "db": "JVNDB", "id": "JVNDB-2023-003918" }, { "db": "NVD", "id": "CVE-2023-29464" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.30:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.20:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-29464" } ] }, "cve": "CVE-2023-29464", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 8.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2023-78312", "impactScore": 7.8, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.2, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "PSIRT@rockwellautomation.com", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "exploitabilityScore": 3.9, "impactScore": 4.2, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.1, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-29464", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-29464", "trust": 1.8, "value": "CRITICAL" }, { "author": "PSIRT@rockwellautomation.com", "id": "CVE-2023-29464", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2023-78312", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-78312" }, { "db": "JVNDB", "id": "JVNDB-2023-003918" }, { "db": "NVD", "id": "CVE-2023-29464" }, { "db": "NVD", "id": "CVE-2023-29464" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "\nFactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol. Rockwell Automation Provided by FactoryTalk Linx The following vulnerabilities exist in. It was * Inappropriate input confirmation (CWE-20) - CVE-2023-29464If the vulnerability is exploited, it may be affected as follows. It was * Information may be obtained by a remote third party via a specially crafted packet, or a denial of service (denial of service) may be attempted. DoS ) state. This product is mainly used for communication between small applications and large automation systems", "sources": [ { "db": "NVD", "id": "CVE-2023-29464" }, { "db": "JVNDB", "id": "JVNDB-2023-003918" }, { "db": "CNVD", "id": "CNVD-2023-78312" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-29464", "trust": 3.2 }, { "db": "JVN", "id": "JVNVU93535614", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-23-290-02", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-003918", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-78312", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-78312" }, { "db": "JVNDB", "id": "JVNDB-2023-003918" }, { "db": "NVD", "id": "CVE-2023-29464" } ] }, "id": "VAR-202310-1699", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-78312" } ], "trust": 1.1021739 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-78312" } ] }, "last_update_date": "2024-05-22T22:32:35.333000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Install\u00a0the\u00a0security\u00a0patches\u00a0for\u00a0the\u00a0respective\u00a0versions (Login required) Rockwell\u00a0Automation", "trust": 0.8, "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140402/loc/en_us" }, { "title": "Patch for Rockwell Automation FactoryTalk Linx Input Validation Error Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/470471" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-78312" }, { "db": "JVNDB", "id": "JVNDB-2023-003918" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Inappropriate input confirmation (CWE-20) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-003918" }, { "db": "NVD", "id": "CVE-2023-29464" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141040" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu93535614/index.html" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-29464" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-290-02" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-78312" }, { "db": "JVNDB", "id": "JVNDB-2023-003918" }, { "db": "NVD", "id": "CVE-2023-29464" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-78312" }, { "db": "JVNDB", "id": "JVNDB-2023-003918" }, { "db": "NVD", "id": "CVE-2023-29464" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-10-20T00:00:00", "db": "CNVD", "id": "CNVD-2023-78312" }, { "date": "2023-10-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-003918" }, { "date": "2023-10-13T13:15:11.453000", "db": "NVD", "id": "CVE-2023-29464" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-10-20T00:00:00", "db": "CNVD", "id": "CNVD-2023-78312" }, { "date": "2024-05-20T08:46:00", "db": "JVNDB", "id": "JVNDB-2023-003918" }, { "date": "2023-10-20T20:10:53.483000", "db": "NVD", "id": "CVE-2023-29464" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Rockwell\u00a0Automation\u00a0 Made \u00a0FactoryTalk\u00a0Linx\u00a0 Improper Input Validation Vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-003918" } ], "trust": 0.8 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.