CWE-284
DiscouragedImproper Access Control
Abstraction: Pillar · Status: Incomplete
The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
8555 vulnerabilities reference this CWE, most recent first.
CVE-2023-23573 (GCVE-0-2023-23573)
Vulnerability from cvelistv5 – Published: 2023-05-10 13:17 – Updated: 2025-01-24 17:48- information disclosure
- CWE-284 - Improper access control
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) Unite(R) android application |
Affected:
before Release 17
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:35:33.070Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00825.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00825.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-23573",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-24T17:48:13.718145Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-24T17:48:22.480Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) Unite(R) android application",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before Release 17"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access control in the Intel(R) Unite(R) android application before Release 17 may allow a privileged user to potentially enable information disclosure via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "information disclosure",
"lang": "en"
},
{
"cweId": "CWE-284",
"description": "Improper access control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-10T13:17:24.919Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00825.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00825.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2023-23573",
"datePublished": "2023-05-10T13:17:24.919Z",
"dateReserved": "2023-02-17T04:00:04.672Z",
"dateUpdated": "2025-01-24T17:48:22.480Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-23446 (GCVE-0-2023-23446)
Vulnerability from cvelistv5 – Published: 2023-05-15 10:52 – Updated: 2026-06-01 12:19- CWE-284 - (Improper Access Control)
| URL | Tags |
|---|---|
| https://sick.com/psirt | issue-tracking |
| https://sick.com/.well-known/csaf/white/2023/sca-… | vendor-advisory |
| https://sick.com/.well-known/csaf/white/2023/sca-… | x_csaf |
| Vendor | Product | Version | |
|---|---|---|---|
| SICK AG | SICK FTMG-ESD15AXX AIR FLOW SENSOR |
Affected:
0 , < v3.0.0.131.Release
(*)
|
|
| SICK AG | SICK FTMG-ESD20AXX AIR FLOW SENSOR |
Affected:
0 , < v3.0.0.131.Release
(*)
|
|
| SICK AG | SICK FTMG-ESD25AXX AIR FLOW SENSOR |
Affected:
0 , < v3.0.0.131.Release
(*)
|
|
| SICK AG | SICK FTMG-ESN40SXX AIR FLOW SENSOR |
Affected:
0 , < v3.0.0.131.Release
(*)
|
|
| SICK AG | SICK FTMG-ESN50SXX AIR FLOW SENSOR |
Affected:
0 , < v3.0.0.131.Release
(*)
|
|
| SICK AG | SICK FTMG-ESR40SXX AIR FLOW SENSOR |
Affected:
0 , < v3.0.0.131.Release
(*)
|
|
| SICK AG | SICK FTMG-ESR50SXX AIR FLOW SENSOR |
Affected:
0 , < v3.0.0.131.Release
(*)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:28:41.041Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.pdf"
},
{
"tags": [
"x_csaf",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.json"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-23446",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-23T19:16:08.743687Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-23T19:16:29.331Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESD15AXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "v3.0.0.131.Release",
"status": "affected",
"version": "0",
"versionType": "*"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESD20AXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "v3.0.0.131.Release",
"status": "affected",
"version": "0",
"versionType": "*"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESD25AXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "v3.0.0.131.Release",
"status": "affected",
"version": "0",
"versionType": "*"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESN40SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "v3.0.0.131.Release",
"status": "affected",
"version": "0",
"versionType": "*"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESN50SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "v3.0.0.131.Release",
"status": "affected",
"version": "0",
"versionType": "*"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESR40SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "v3.0.0.131.Release",
"status": "affected",
"version": "0",
"versionType": "*"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESR50SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "v3.0.0.131.Release",
"status": "affected",
"version": "0",
"versionType": "*"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers\n1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to download files by using a therefore unpriviledged account via the REST interface."
}
],
"value": "Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers\n1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to download files by using a therefore unpriviledged account via the REST interface."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 (Improper Access Control)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-01T12:19:51.613Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"issue-tracking"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.pdf"
},
{
"tags": [
"x_csaf"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "SICK has released a new major version v3.0.0.131.Release of the SICK FTMg firmware and\nrecommends updating to the newest version."
}
],
"value": "SICK has released a new major version v3.0.0.131.Release of the SICK FTMg firmware and\nrecommends updating to the newest version."
}
],
"source": {
"discovery": "INTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2023-23446",
"datePublished": "2023-05-15T10:52:30.269Z",
"dateReserved": "2023-01-12T04:07:53.938Z",
"dateUpdated": "2026-06-01T12:19:51.613Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-23445 (GCVE-0-2023-23445)
Vulnerability from cvelistv5 – Published: 2023-05-15 10:51 – Updated: 2026-06-01 12:20- CWE-284 - Improper Access Control
| URL | Tags |
|---|---|
| https://sick.com/psirt | issue-tracking |
| https://sick.com/.well-known/csaf/white/2023/sca-… | vendor-advisory |
| https://sick.com/.well-known/csaf/white/2023/sca-… | x_csaf |
| Vendor | Product | Version | |
|---|---|---|---|
| SICK AG | SICK FTMG-ESD15AXX AIR FLOW SENSOR |
Affected:
all firmware versions
|
|
| SICK AG | SICK FTMG-ESD20AXX AIR FLOW SENSOR |
Affected:
all firmware versions
|
|
| SICK AG | SICK FTMG-ESD25AXX AIR FLOW SENSOR |
Affected:
all firmware versions
|
|
| SICK AG | SICK FTMG-ESN40SXX AIR FLOW SENSOR |
Affected:
all firmware versions
|
|
| SICK AG | SICK FTMG-ESN50SXX AIR FLOW SENSOR |
Affected:
all firmware versions
|
|
| SICK AG | SICK FTMG-ESR40SXX AIR FLOW SENSOR |
Affected:
all firmware versions
|
|
| SICK AG | SICK FTMG-ESR50SXX AIR FLOW SENSOR |
Affected:
all firmware versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:28:40.858Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.pdf"
},
{
"tags": [
"x_csaf",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.json"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-23445",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-23T19:17:53.365000Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-23T19:17:56.655Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESD15AXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESD20AXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESD25AXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESN40SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESN50SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESR40SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESR50SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers\n1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote\nattacker to gain unauthorized access to data fields by using a therefore unpriviledged account via the\nREST interface."
}
],
"value": "Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers\n1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote\nattacker to gain unauthorized access to data fields by using a therefore unpriviledged account via the\nREST interface."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-01T12:20:49.066Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"issue-tracking"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.pdf"
},
{
"tags": [
"x_csaf"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.json"
}
],
"source": {
"discovery": "INTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Please make sure that you apply general security practices when operating the SICK FTMg\nlike network segmentation. The following General Security Practices and Operating Guidelines could\nmitigate the associated security risk."
}
],
"value": "Please make sure that you apply general security practices when operating the SICK FTMg\nlike network segmentation. The following General Security Practices and Operating Guidelines could\nmitigate the associated security risk."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2023-23445",
"datePublished": "2023-05-15T10:51:44.194Z",
"dateReserved": "2023-01-12T04:07:53.938Z",
"dateUpdated": "2026-06-01T12:20:49.066Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-22920 (GCVE-0-2023-22920)
Vulnerability from cvelistv5 – Published: 2023-02-21 00:00 – Updated: 2025-03-12 14:35- CWE-284 - Improper Access Control
| Vendor | Product | Version | |
|---|---|---|---|
| Zyxel | LTE3316-M604 |
Affected:
V2.00(ABMP.6)C0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:20:31.430Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.zyxel.com/global/en/support/security-advisories/zyxel-security-advisory-for-security-misconfiguration-vulnerability-of-4g-lte-indoor-routers"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-22920",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-12T14:34:23.719581Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-12T14:35:22.085Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "LTE3316-M604",
"vendor": "Zyxel",
"versions": [
{
"status": "affected",
"version": "V2.00(ABMP.6)C0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A security misconfiguration vulnerability exists in the Zyxel LTE3316-M604 firmware version V2.00(ABMP.6)C0 due to a factory default misconfiguration intended for testing purposes. A remote attacker could leverage this vulnerability to access an affected device using Telnet."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-21T00:00:00.000Z",
"orgId": "96e50032-ad0d-4058-a115-4d2c13821f9f",
"shortName": "Zyxel"
},
"references": [
{
"url": "https://www.zyxel.com/global/en/support/security-advisories/zyxel-security-advisory-for-security-misconfiguration-vulnerability-of-4g-lte-indoor-routers"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "96e50032-ad0d-4058-a115-4d2c13821f9f",
"assignerShortName": "Zyxel",
"cveId": "CVE-2023-22920",
"datePublished": "2023-02-21T00:00:00.000Z",
"dateReserved": "2023-01-10T00:00:00.000Z",
"dateUpdated": "2025-03-12T14:35:22.085Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-22848 (GCVE-0-2023-22848)
Vulnerability from cvelistv5 – Published: 2024-02-14 13:37 – Updated: 2024-08-16 19:47- denial of service
- CWE-284 - Improper access control
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) Thunderbolt(TM) DCH drivers for Windows |
Affected:
before version 88
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:20:30.914Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00851.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00851.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-22848",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-16T19:47:44.004003Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-16T19:47:52.822Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) Thunderbolt(TM) DCH drivers for Windows",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "before version 88"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access control in some Intel(R) Thunderbolt(TM) DCH drivers for Windows before version 88 may allow an authenticated user to potentially enable denial of service via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "denial of service",
"lang": "en"
},
{
"cweId": "CWE-284",
"description": "Improper access control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-14T13:37:43.471Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00851.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00851.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2023-22848",
"datePublished": "2024-02-14T13:37:43.471Z",
"dateReserved": "2023-02-28T04:00:03.238Z",
"dateUpdated": "2024-08-16T19:47:52.822Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-22807 (GCVE-0-2023-22807)
Vulnerability from cvelistv5 – Published: 2023-02-15 17:29 – Updated: 2025-01-16 21:56- CWE-284 - Improper Access Control
| Vendor | Product | Version | |
|---|---|---|---|
| LS Electric | XBC-DN32U |
Affected:
Operating System Version 01.80
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:20:31.221Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-040-02"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-22807",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-16T20:59:11.235636Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-16T21:56:14.871Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "XBC-DN32U",
"vendor": "LS Electric",
"versions": [
{
"status": "affected",
"version": "Operating System Version 01.80"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "HeeA Go of Dankook University reported these vulnerabilities"
}
],
"datePublic": "2023-02-09T21:05:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eLS ELECTRIC XBC-DN32U with operating system version 01.80 does not properly control access to the PLC over its internal XGT protocol. An attacker could control and tamper with the PLC by sending the packets to the PLC over its XGT protocol.\u003c/p\u003e"
}
],
"value": "LS ELECTRIC XBC-DN32U with operating system version 01.80 does not properly control access to the PLC over its internal XGT protocol. An attacker could control and tamper with the PLC by sending the packets to the PLC over its XGT protocol.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-15T17:29:47.415Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-040-02"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "CVE-2023-22807",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003eLS ELECTRIC is developing mitigations (to be released tentatively by the end of 2023) and recommends users follow the provided workarounds to reduce the risk of exploitation: \u003c/p\u003e\u003cul\u003e\u003cli\u003eRestrict communication to the PLC to only trusted IP addresses and trusted devices by enabling the \u201cHost Table\u201d option in the configuration window of the PLC. \u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
}
],
"value": "\nLS ELECTRIC is developing mitigations (to be released tentatively by the end of 2023) and recommends users follow the provided workarounds to reduce the risk of exploitation: \n\n * Restrict communication to the PLC to only trusted IP addresses and trusted devices by enabling the \u201cHost Table\u201d option in the configuration window of the PLC. \n\n\n\n\n\n"
}
],
"x_generator": {
"engine": "VINCE 2.0.6",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2023-22807"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-22807",
"datePublished": "2023-02-15T17:29:47.415Z",
"dateReserved": "2023-01-06T18:49:55.855Z",
"dateUpdated": "2025-01-16T21:56:14.871Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-22805 (GCVE-0-2023-22805)
Vulnerability from cvelistv5 – Published: 2023-02-15 17:27 – Updated: 2025-01-16 21:56- CWE-284 - Improper Access Control
| Vendor | Product | Version | |
|---|---|---|---|
| LS Electric | XBC-DN32U |
Affected:
Operating System Version 01.80
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:20:30.904Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-040-02"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-22805",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-16T20:21:58.852255Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-16T21:56:38.793Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "XBC-DN32U",
"vendor": "LS Electric",
"versions": [
{
"status": "affected",
"version": "Operating System Version 01.80"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "HeeA Go of Dankook University reported these vulnerabilities"
}
],
"datePublic": "2023-02-09T21:03:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eLS ELECTRIC XBC-DN32U with operating system version 01.80 has improper access control to its read prohibition feature. This could allow a remote attacker to remotely set the feature to lock users out of reading data from the device.\u003c/p\u003e"
}
],
"value": "LS ELECTRIC XBC-DN32U with operating system version 01.80 has improper access control to its read prohibition feature. This could allow a remote attacker to remotely set the feature to lock users out of reading data from the device.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-15T17:27:50.026Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-040-02"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "CVE-2023-22805",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003eLS ELECTRIC is developing mitigations (to be released tentatively by the end of 2023) and recommends users follow the provided workarounds to reduce the risk of exploitation: \u003c/p\u003e\u003cul\u003e\u003cli\u003eRestrict communication to the PLC to only trusted IP addresses and trusted devices by enabling the \u201cHost Table\u201d option in the configuration window of the PLC. \u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
}
],
"value": "\nLS ELECTRIC is developing mitigations (to be released tentatively by the end of 2023) and recommends users follow the provided workarounds to reduce the risk of exploitation: \n\n * Restrict communication to the PLC to only trusted IP addresses and trusted devices by enabling the \u201cHost Table\u201d option in the configuration window of the PLC. \n\n\n\n\n\n"
}
],
"x_generator": {
"engine": "VINCE 2.0.6",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2023-22805"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-22805",
"datePublished": "2023-02-15T17:27:50.026Z",
"dateReserved": "2023-01-06T18:49:55.855Z",
"dateUpdated": "2025-01-16T21:56:38.793Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-22600 (GCVE-0-2023-22600)
Vulnerability from cvelistv5 – Published: 2023-01-12 22:33 – Updated: 2025-01-16 22:02- CWE-284 - Improper Access Control
| URL | Tags |
|---|---|
| https://www.cisa.gov/uscert/ics/advisories/icsa-2… | government-resource |
| Vendor | Product | Version | |
|---|---|---|---|
| InHand Networks | InRouter 302 |
Affected:
0 , < IR302 V3.5.56
(custom)
|
|
| InHand Networks | InRouter 615 |
Affected:
0 , < InRouter6XX-S-V2.3.0.r5542
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:13:49.121Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-012-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-22600",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-16T20:57:31.348725Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-16T22:02:20.939Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "InRouter 302",
"vendor": "InHand Networks",
"versions": [
{
"lessThan": "IR302 V3.5.56",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "InRouter 615",
"vendor": "InHand Networks",
"versions": [
{
"lessThan": "InRouter6XX-S-V2.3.0.r5542",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Roni Gavrilov"
},
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "OTORIO"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eInHand Networks InRouter 302, prior to version IR302 V3.5.56, and InRouter 615, prior to version InRouter6XX-S-V2.3.0.r5542, contain vulnerability CWE-284: Improper Access Control. They\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eallow unauthenticated devices to subscribe to MQTT topics on the same network as the device manager. An unauthorized user who knows of an existing topic name could send and receive messages to and from that topic. This includes the ability to send GET/SET configuration commands, reboot commands, and push firmware updates. \u003c/span\u003e\n\n \u003c/span\u003e\n\n \u003c/span\u003e\n\n \n\n \u003c/span\u003e\n\n"
}
],
"value": "\nInHand Networks InRouter 302, prior to version IR302 V3.5.56, and InRouter 615, prior to version InRouter6XX-S-V2.3.0.r5542, contain vulnerability CWE-284: Improper Access Control. They\u00a0allow unauthenticated devices to subscribe to MQTT topics on the same network as the device manager. An unauthorized user who knows of an existing topic name could send and receive messages to and from that topic. This includes the ability to send GET/SET configuration commands, reboot commands, and push firmware updates. \n\n \n\n \n\n \n\n \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-12T22:33:16.337Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-012-03"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-22600",
"datePublished": "2023-01-12T22:33:16.337Z",
"dateReserved": "2023-01-03T19:55:20.124Z",
"dateUpdated": "2025-01-16T22:02:20.939Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-22487 (GCVE-0-2023-22487)
Vulnerability from cvelistv5 – Published: 2023-01-11 19:49 – Updated: 2025-03-10 21:30- CWE-284 - Improper Access Control
| URL | Tags |
|---|---|
| https://github.com/flarum/framework/security/advi… | x_refsource_CONFIRM |
| https://github.com/flarum/framework/commit/ab1c86… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:13:48.533Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://github.com/flarum/framework/security/advisories/GHSA-22m9-m3ww-53h3",
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://github.com/flarum/framework/security/advisories/GHSA-22m9-m3ww-53h3"
},
{
"name": "https://github.com/flarum/framework/commit/ab1c868b978e8b0d09a5d682c54665dae17d0985",
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/flarum/framework/commit/ab1c868b978e8b0d09a5d682c54665dae17d0985"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-22487",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-10T21:01:41.331652Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-10T21:30:35.411Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "framework",
"vendor": "flarum",
"versions": [
{
"status": "affected",
"version": "\u003c 1.6.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Flarum is a forum software for building communities. Using the mentions feature provided by the flarum/mentions extension, users can mention any post ID on the forum with the special `@\"\u003cusername\u003e\"#p\u003cid\u003e` syntax. The following behavior never changes no matter if the actor should be able to read the mentioned post or not: A URL to the mentioned post is inserted into the actor post HTML, leaking its discussion ID and post number. The `mentionsPosts` relationship included in the `POST /api/posts` and `PATCH /api/posts/\u003cid\u003e` JSON responses leaks the full JSON:API payload of all mentioned posts without any access control. This includes the content, date, number and attributes added by other extensions. An attacker only needs the ability to create new posts on the forum to exploit the vulnerability. This works even if new posts require approval. If they have the ability to edit posts, the attack can be performed even more discreetly by using a single post to scan any size of database and hiding the attack post content afterward. The attack allows the leaking of all posts in the forum database, including posts awaiting approval, posts in tags the user has no access to, and private discussions created by other extensions like FriendsOfFlarum Byobu. This also includes non-comment posts like tag changes or renaming events. The discussion payload is not leaked but using the mention HTML payload it\u0027s possible to extract the discussion ID of all posts and combine all posts back together into their original discussions even if the discussion title remains unknown. All Flarum versions prior to 1.6.3 are affected. The vulnerability has been fixed and published as flarum/core v1.6.3. As a workaround, user can disable the mentions extension."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-11T19:49:37.668Z",
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M"
},
"references": [
{
"name": "https://github.com/flarum/framework/security/advisories/GHSA-22m9-m3ww-53h3",
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/flarum/framework/security/advisories/GHSA-22m9-m3ww-53h3"
},
{
"name": "https://github.com/flarum/framework/commit/ab1c868b978e8b0d09a5d682c54665dae17d0985",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/flarum/framework/commit/ab1c868b978e8b0d09a5d682c54665dae17d0985"
}
],
"source": {
"advisory": "GHSA-22m9-m3ww-53h3",
"discovery": "UNKNOWN"
},
"title": "Post mentions can be used to read any post on the forum without access control"
}
},
"cveMetadata": {
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"assignerShortName": "GitHub_M",
"cveId": "CVE-2023-22487",
"datePublished": "2023-01-11T19:49:37.668Z",
"dateReserved": "2022-12-29T17:41:28.089Z",
"dateUpdated": "2025-03-10T21:30:35.411Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-22473 (GCVE-0-2023-22473)
Vulnerability from cvelistv5 – Published: 2023-01-09 14:07 – Updated: 2025-03-10 21:31- CWE-284 - Improper Access Control
| URL | Tags |
|---|---|
| https://github.com/nextcloud/security-advisories/… | x_refsource_CONFIRM |
| https://github.com/nextcloud/talk-android/pull/2598 | x_refsource_MISC |
| https://hackerone.com/reports/1784645 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| nextcloud | security-advisories |
Affected:
< 15.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:13:48.470Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://github.com/nextcloud/security-advisories/security/advisories/GHSA-wvr4-gc4c-6vmx",
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://github.com/nextcloud/security-advisories/security/advisories/GHSA-wvr4-gc4c-6vmx"
},
{
"name": "https://github.com/nextcloud/talk-android/pull/2598",
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/nextcloud/talk-android/pull/2598"
},
{
"name": "https://hackerone.com/reports/1784645",
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://hackerone.com/reports/1784645"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-22473",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-10T21:01:47.088000Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-10T21:31:11.966Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "security-advisories",
"vendor": "nextcloud",
"versions": [
{
"status": "affected",
"version": "\u003c 15.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Talk-Android enables users to have video \u0026 audio calls through Nextcloud on Android. Due to passcode bypass, an attacker is able to access the user\u0027s Nextcloud files and view conversations. To exploit this the attacker needs to have physical access to the target\u0027s device. There are currently no known workarounds available. It is recommended that the Nextcloud Talk Android app is upgraded to 15.0.2. \n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-09T14:07:14.923Z",
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M"
},
"references": [
{
"name": "https://github.com/nextcloud/security-advisories/security/advisories/GHSA-wvr4-gc4c-6vmx",
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/nextcloud/security-advisories/security/advisories/GHSA-wvr4-gc4c-6vmx"
},
{
"name": "https://github.com/nextcloud/talk-android/pull/2598",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/nextcloud/talk-android/pull/2598"
},
{
"name": "https://hackerone.com/reports/1784645",
"tags": [
"x_refsource_MISC"
],
"url": "https://hackerone.com/reports/1784645"
}
],
"source": {
"advisory": "GHSA-wvr4-gc4c-6vmx",
"discovery": "UNKNOWN"
},
"title": "Passcode bypass on Talk-Android app"
}
},
"cveMetadata": {
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"assignerShortName": "GitHub_M",
"cveId": "CVE-2023-22473",
"datePublished": "2023-01-09T14:07:14.923Z",
"dateReserved": "2022-12-29T03:00:40.880Z",
"dateUpdated": "2025-03-10T21:31:11.966Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation MIT-1
Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.
Mitigation MIT-46
Strategy: Separation of Privilege
- Compartmentalize the system to have "safe" areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area.
- Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.
CAPEC-19: Embedding Scripts within Scripts
An adversary leverages the capability to execute their own script by embedding it within other scripts that the target software is likely to execute due to programs' vulnerabilities that are brought on by allowing remote hosts to execute scripts.
CAPEC-441: Malicious Logic Insertion
An adversary installs or adds malicious logic (also known as malware) into a seemingly benign component of a fielded system. This logic is often hidden from the user of the system and works behind the scenes to achieve negative impacts. With the proliferation of mass digital storage and inexpensive multimedia devices, Bluetooth and 802.11 support, new attack vectors for spreading malware are emerging for things we once thought of as innocuous greeting cards, picture frames, or digital projectors. This pattern of attack focuses on systems already fielded and used in operation as opposed to systems and their components that are still under development and part of the supply chain.
CAPEC-478: Modification of Windows Service Configuration
An adversary exploits a weakness in access control to modify the execution parameters of a Windows service. The goal of this attack is to execute a malicious binary in place of an existing service.
CAPEC-479: Malicious Root Certificate
An adversary exploits a weakness in authorization and installs a new root certificate on a compromised system. Certificates are commonly used for establishing secure TLS/SSL communications within a web browser. When a user attempts to browse a website that presents a certificate that is not trusted an error message will be displayed to warn the user of the security risk. Depending on the security settings, the browser may not allow the user to establish a connection to the website. Adversaries have used this technique to avoid security warnings prompting users when compromised systems connect over HTTPS to adversary controlled web servers that spoof legitimate websites in order to collect login credentials.
CAPEC-502: Intent Spoof
An adversary, through a previously installed malicious application, issues an intent directed toward a specific trusted application's component in an attempt to achieve a variety of different objectives including modification of data, information disclosure, and data injection. Components that have been unintentionally exported and made public are subject to this type of an attack. If the component trusts the intent's action without verififcation, then the target application performs the functionality at the adversary's request, helping the adversary achieve the desired negative technical impact.
CAPEC-503: WebView Exposure
An adversary, through a malicious web page, accesses application specific functionality by leveraging interfaces registered through WebView's addJavascriptInterface API. Once an interface is registered to WebView through addJavascriptInterface, it becomes global and all pages loaded in the WebView can call this interface.
CAPEC-536: Data Injected During Configuration
An attacker with access to data files and processes on a victim's system injects malicious data into critical operational data during configuration or recalibration, causing the victim's system to perform in a suboptimal manner that benefits the adversary.
CAPEC-546: Incomplete Data Deletion in a Multi-Tenant Environment
An adversary obtains unauthorized information due to insecure or incomplete data deletion in a multi-tenant environment. If a cloud provider fails to completely delete storage and data from former cloud tenants' systems/resources, once these resources are allocated to new, potentially malicious tenants, the latter can probe the provided resources for sensitive information still there.
CAPEC-550: Install New Service
When an operating system starts, it also starts programs called services or daemons. Adversaries may install a new service which will be executed at startup (on a Windows system, by modifying the registry). The service name may be disguised by using a name from a related operating system or benign software. Services are usually run with elevated privileges.
CAPEC-551: Modify Existing Service
When an operating system starts, it also starts programs called services or daemons. Modifying existing services may break existing services or may enable services that are disabled/not commonly used.
CAPEC-552: Install Rootkit
An adversary exploits a weakness in authentication to install malware that alters the functionality and information provide by targeted operating system API calls. Often referred to as rootkits, it is often used to hide the presence of programs, files, network connections, services, drivers, and other system components.
CAPEC-556: Replace File Extension Handlers
When a file is opened, its file handler is checked to determine which program opens the file. File handlers are configuration properties of many operating systems. Applications can modify the file handler for a given file extension to call an arbitrary program when a file with the given extension is opened.
CAPEC-558: Replace Trusted Executable
An adversary exploits weaknesses in privilege management or access control to replace a trusted executable with a malicious version and enable the execution of malware when that trusted executable is called.
CAPEC-562: Modify Shared File
An adversary manipulates the files in a shared location by adding malicious programs, scripts, or exploit code to valid content. Once a user opens the shared content, the tainted content is executed.
CAPEC-563: Add Malicious File to Shared Webroot
An adversaries may add malicious content to a website through the open file share and then browse to that content with a web browser to cause the server to execute the content. The malicious content will typically run under the context and permissions of the web server process, often resulting in local system or administrative privileges depending on how the web server is configured.
CAPEC-564: Run Software at Logon
Operating system allows logon scripts to be run whenever a specific user or users logon to a system. If adversaries can access these scripts, they may insert additional code into the logon script. This code can allow them to maintain persistence or move laterally within an enclave because it is executed every time the affected user or users logon to a computer. Modifying logon scripts can effectively bypass workstation and enclave firewalls. Depending on the access configuration of the logon scripts, either local credentials or a remote administrative account may be necessary.
CAPEC-578: Disable Security Software
An adversary exploits a weakness in access control to disable security tools so that detection does not occur. This can take the form of killing processes, deleting registry keys so that tools do not start at run time, deleting log files, or other methods.