GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration
Common Weakness Enumeration

CWE-307

Allowed

Improper Restriction of Excessive Authentication Attempts

Abstraction: Base · Status: Draft

The product does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame.

1002 vulnerabilities reference this CWE, most recent first.

CVE-2023-25820 (GCVE-0-2023-25820)

Vulnerability from cvelistv5 – Published: 2023-03-22 18:22 – Updated: 2025-02-25 14:51
VLAI
Title
Nextcloud Server and Enterprise Server missing brute force protection on password confirmation modal
Summary
Nextcloud Server is the file server software for Nextcloud, a self-hosted productivity platform, and Nextcloud Enterprise Server is the enterprise version of the file server software. In Nextcloud Server versions 25.0.x prior to 25.0.5 and versions 24.0.x prior to 24.0.10 as well as Nextcloud Enterprise Server versions 25.0.x prior to 25.0.4, 24.0.x prior to 24.0.10, 23.0.x prior to 23.0.12.5, 22.x prior to 22.2.0.10, and 21.x prior to 21.0.9.10, when an attacker gets access to an already logged in user session they can then brute force the password on the confirmation endpoint. Nextcloud Server should upgraded to 24.0.10 or 25.0.4 and Nextcloud Enterprise Server should upgraded to 21.0.9.10, 22.2.10.10, 23.0.12.5, 24.0.10, or 25.0.4 to receive a patch. No known workarounds are available.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-25 14:28 UTC
CWE
  • CWE-307 - Improper Restriction of Excessive Authentication Attempts
References
Impacted products
Vendor Product Version
nextcloud security-advisories Affected: Nextcloud Server >= 24.0.0, < 24.0.10
Affected: Nextcloud Server >= 25.0.0, < 25.0.4
Affected: Nextcloud Enterprise Server >= 25.0.0, < 25.0.4
Affected: Nextcloud Enterprise Server >= 24.0.0, < 24.0.10
Affected: Nextcloud Enterprise Server >= 23.0.0, < 23.0.12.5
Affected: Nextcloud Enterprise Server >= 22.0.0, < 22.2.10.10
Affected: Nextcloud Enterprise Server >= 21.0.0, < 21.0.9.10
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T11:32:12.380Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://github.com/nextcloud/security-advisories/security/advisories/GHSA-36g6-wjx2-333x",
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/nextcloud/security-advisories/security/advisories/GHSA-36g6-wjx2-333x"
          },
          {
            "name": "https://github.com/nextcloud/server/pull/36489",
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/nextcloud/server/pull/36489"
          },
          {
            "name": "https://hackerone.com/reports/1842114",
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://hackerone.com/reports/1842114"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-25820",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-25T14:28:26.634913Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-25T14:51:54.712Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "security-advisories",
          "vendor": "nextcloud",
          "versions": [
            {
              "status": "affected",
              "version": "Nextcloud Server \u003e= 24.0.0, \u003c 24.0.10"
            },
            {
              "status": "affected",
              "version": "Nextcloud Server \u003e= 25.0.0, \u003c 25.0.4"
            },
            {
              "status": "affected",
              "version": "Nextcloud Enterprise Server \u003e= 25.0.0, \u003c 25.0.4"
            },
            {
              "status": "affected",
              "version": "Nextcloud Enterprise Server \u003e= 24.0.0, \u003c 24.0.10"
            },
            {
              "status": "affected",
              "version": "Nextcloud Enterprise Server \u003e= 23.0.0, \u003c 23.0.12.5"
            },
            {
              "status": "affected",
              "version": "Nextcloud Enterprise Server \u003e= 22.0.0, \u003c 22.2.10.10"
            },
            {
              "status": "affected",
              "version": "Nextcloud Enterprise Server \u003e= 21.0.0, \u003c 21.0.9.10"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Nextcloud Server is the file server software for Nextcloud, a self-hosted productivity platform, and Nextcloud Enterprise Server is the enterprise version of the file server software. In Nextcloud Server versions 25.0.x prior to 25.0.5 and versions 24.0.x prior to 24.0.10 as well as Nextcloud Enterprise Server versions 25.0.x prior to 25.0.4, 24.0.x prior to 24.0.10, 23.0.x prior to 23.0.12.5, 22.x prior to 22.2.0.10, and 21.x prior to 21.0.9.10, when an attacker gets access to an already logged in user session they can then brute force the password on the confirmation endpoint. Nextcloud Server should upgraded to 24.0.10 or 25.0.4 and Nextcloud Enterprise Server should upgraded to 21.0.9.10, 22.2.10.10, 23.0.12.5, 24.0.10, or 25.0.4 to receive a patch. No known workarounds are available."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 4.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307: Improper Restriction of Excessive Authentication Attempts",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-22T18:22:54.139Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/nextcloud/security-advisories/security/advisories/GHSA-36g6-wjx2-333x",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/nextcloud/security-advisories/security/advisories/GHSA-36g6-wjx2-333x"
        },
        {
          "name": "https://github.com/nextcloud/server/pull/36489",
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/nextcloud/server/pull/36489"
        },
        {
          "name": "https://hackerone.com/reports/1842114",
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://hackerone.com/reports/1842114"
        }
      ],
      "source": {
        "advisory": "GHSA-36g6-wjx2-333x",
        "discovery": "UNKNOWN"
      },
      "title": "Nextcloud Server and Enterprise Server missing brute force protection on password confirmation modal"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2023-25820",
    "datePublished": "2023-03-22T18:22:54.139Z",
    "dateReserved": "2023-02-15T16:34:48.774Z",
    "dateUpdated": "2025-02-25T14:51:54.712Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-25818 (GCVE-0-2023-25818)

Vulnerability from cvelistv5 – Published: 2023-03-27 20:00 – Updated: 2025-02-19 15:23
VLAI
Title
Missing brute force protection on password reset token in Nextcloud Server
Summary
Nextcloud server is an open source, personal cloud implementation. In affected versions a malicious user could try to reset the password of another user and then brute force the 62^21 combinations for the password reset token. As of commit `704eb3aa` password reset attempts are now throttled. Note that 62^21 combinations would significant compute resources to brute force. None the less it is recommended that the Nextcloud Server is upgraded to 24.0.10 or 25.0.4. There are no known workarounds for this vulnerability.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-19 15:22 UTC
CWE
  • CWE-307 - Improper Restriction of Excessive Authentication Attempts
Impacted products
Vendor Product Version
nextcloud security-advisories Affected: >= 24.0.0, < 24.0.10
Affected: >= 25.0.0, < 25.0.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T11:32:12.551Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://github.com/nextcloud/security-advisories/security/advisories/GHSA-v243-x6jc-42mp",
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/nextcloud/security-advisories/security/advisories/GHSA-v243-x6jc-42mp"
          },
          {
            "name": "https://github.com/nextcloud/server/pull/36489",
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/nextcloud/server/pull/36489"
          },
          {
            "name": "https://github.com/nextcloud/server/pull/36489/commits/704eb3aa6cecc0a646f5cca4290b595f493f9ed3",
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/nextcloud/server/pull/36489/commits/704eb3aa6cecc0a646f5cca4290b595f493f9ed3"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-25818",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-19T15:22:55.116439Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-19T15:23:50.147Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "security-advisories",
          "vendor": "nextcloud",
          "versions": [
            {
              "status": "affected",
              "version": "\u003e= 24.0.0, \u003c 24.0.10"
            },
            {
              "status": "affected",
              "version": "\u003e= 25.0.0, \u003c 25.0.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Nextcloud server is an open source, personal cloud implementation. In affected versions a malicious user could try to reset the password of another user and then brute force the 62^21 combinations for the password reset token. As of commit `704eb3aa` password reset attempts are now throttled. Note that 62^21 combinations would significant compute resources to brute force. None the less it is recommended that the Nextcloud Server is upgraded to 24.0.10 or 25.0.4. There are no known workarounds for this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307: Improper Restriction of Excessive Authentication Attempts",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-27T20:00:01.019Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/nextcloud/security-advisories/security/advisories/GHSA-v243-x6jc-42mp",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/nextcloud/security-advisories/security/advisories/GHSA-v243-x6jc-42mp"
        },
        {
          "name": "https://github.com/nextcloud/server/pull/36489",
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/nextcloud/server/pull/36489"
        },
        {
          "name": "https://github.com/nextcloud/server/pull/36489/commits/704eb3aa6cecc0a646f5cca4290b595f493f9ed3",
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/nextcloud/server/pull/36489/commits/704eb3aa6cecc0a646f5cca4290b595f493f9ed3"
        }
      ],
      "source": {
        "advisory": "GHSA-v243-x6jc-42mp",
        "discovery": "UNKNOWN"
      },
      "title": "Missing brute force protection on password reset token in Nextcloud Server"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2023-25818",
    "datePublished": "2023-03-27T20:00:01.019Z",
    "dateReserved": "2023-02-15T16:34:48.773Z",
    "dateUpdated": "2025-02-19T15:23:50.147Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-24020 (GCVE-0-2023-24020)

Vulnerability from cvelistv5 – Published: 2023-01-30 21:54 – Updated: 2025-01-16 21:58
VLAI
Summary
Snap One Wattbox WB-300-IP-3 versions WB10.9a17 and prior could bypass the brute force protection, allowing multiple attempts to force a login.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-16 20:57 UTC
CWE
  • CWE-307 - Improper Restriction of Excessive Authentication Attempts
Impacted products
Vendor Product Version
Snap One Wattbox WB-300-IP-3 Affected: 0 , ≤ WB10.9a17 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T10:49:08.992Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-026-03"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-24020",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:57:01.767529Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:58:48.037Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Wattbox WB-300-IP-3",
          "vendor": "Snap One",
          "versions": [
            {
              "lessThanOrEqual": "WB10.9a17",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Uri Katz of Claroty Research reported these vulnerabilities to CISA. "
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eSnap One Wattbox WB-300-IP-3 versions WB10.9a17 and prior could bypass the brute force protection, allowing multiple attempts to force a login. \u003c/p\u003e\u003cbr\u003e\n\n"
            }
          ],
          "value": "\nSnap One Wattbox WB-300-IP-3 versions WB10.9a17 and prior could bypass the brute force protection, allowing multiple attempts to force a login. \n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-30T21:54:49.887Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-026-03"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eSnap One has released the following updates for the affected products: \u003c/p\u003e\u003cul\u003e\u003cli\u003eVersion \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://app.ovrc.com/#/user-settings\"\u003eWB10.B929\u003c/a\u003e\u0026nbsp;(login required) \u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nSnap One has released the following updates for the affected products: \n\n  *  Version  WB10.B929 https://app.ovrc.com/#/user-settings \u00a0(login required) \n\n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-24020",
    "datePublished": "2023-01-30T21:54:49.887Z",
    "dateReserved": "2023-01-23T23:57:52.042Z",
    "dateUpdated": "2025-01-16T21:58:48.037Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-23730 (GCVE-0-2023-23730)

Vulnerability from cvelistv5 – Published: 2024-06-03 21:24 – Updated: 2026-04-28 16:08
VLAI
Title
WordPress Spectra – WordPress Gutenberg Blocks plugin <= 2.3.0 - Captcha Bypass Vulnerability
Summary
Improper Restriction of Excessive Authentication Attempts vulnerability in Brainstorm Force Spectra allows Functionality Bypass.This issue affects Spectra: from n/a through 2.3.0.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-04 19:15 UTC
CWE
  • CWE-307 - Improper Restriction of Excessive Authentication Attempts
References
Impacted products
Vendor Product Version
Brainstorm Force Spectra Affected: n/a , ≤ 2.3.0 (custom)
Create a notification for this product.
brainstormforce spectra Affected: 0 , ≤ 2.3.0 (custom)
Unaffected: 2.3.1
    cpe:2.3:a:brainstormforce:spectra:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brainstormforce:spectra:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "spectra",
            "vendor": "brainstormforce",
            "versions": [
              {
                "lessThanOrEqual": "2.3.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "status": "unaffected",
                "version": "2.3.1"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-23730",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-04T19:15:04.370781Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-25T13:30:51.929Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T10:42:25.769Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "https://patchstack.com/database/vulnerability/ultimate-addons-for-gutenberg/wordpress-spectra-wordpress-gutenberg-blocks-plugin-2-3-0-captcha-bypass-vulnerability?_s_id=cve"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "collectionURL": "https://wordpress.org/plugins",
          "defaultStatus": "unaffected",
          "packageName": "ultimate-addons-for-gutenberg",
          "product": "Spectra",
          "vendor": "Brainstorm Force",
          "versions": [
            {
              "changes": [
                {
                  "at": "2.3.1",
                  "status": "unaffected"
                }
              ],
              "lessThanOrEqual": "2.3.0",
              "status": "affected",
              "version": "n/a",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Dave Jong (Patchstack)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Restriction of Excessive Authentication Attempts vulnerability in Brainstorm Force Spectra allows Functionality Bypass.\u003cp\u003eThis issue affects Spectra: from n/a through 2.3.0.\u003c/p\u003e"
            }
          ],
          "value": "Improper Restriction of Excessive Authentication Attempts vulnerability in Brainstorm Force Spectra allows Functionality Bypass.This issue affects Spectra: from n/a through 2.3.0."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-554",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-554 Functionality Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-28T16:08:01.567Z",
        "orgId": "21595511-bba5-4825-b968-b78d1f9984a3",
        "shortName": "Patchstack"
      },
      "references": [
        {
          "tags": [
            "vdb-entry"
          ],
          "url": "https://patchstack.com/database/vulnerability/ultimate-addons-for-gutenberg/wordpress-spectra-wordpress-gutenberg-blocks-plugin-2-3-0-captcha-bypass-vulnerability?_s_id=cve"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Update to 2.3.1 or a higher version."
            }
          ],
          "value": "Update to 2.3.1 or a higher version."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "WordPress Spectra \u2013 WordPress Gutenberg Blocks plugin \u003c= 2.3.0 - Captcha Bypass Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "21595511-bba5-4825-b968-b78d1f9984a3",
    "assignerShortName": "Patchstack",
    "cveId": "CVE-2023-23730",
    "datePublished": "2024-06-03T21:24:35.797Z",
    "dateReserved": "2023-01-17T15:49:23.462Z",
    "dateUpdated": "2026-04-28T16:08:01.567Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2023-21709 (GCVE-0-2023-21709)

Vulnerability from cvelistv5 – Published: 2023-08-08 17:08 – Updated: 2026-08-10 15:11
VLAI
Title
Microsoft Exchange Server Elevation of Privilege Vulnerability
Summary
Microsoft Exchange Server Elevation of Privilege Vulnerability
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-26 21:51 UTC
CWE
  • CWE-307 - Improper Restriction of Excessive Authentication Attempts
References
Date Public
2023-08-08 07:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T09:44:02.165Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "Microsoft Exchange Server Elevation of Privilege Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2023-21709"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-21709",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-26T21:51:01.605859Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-27T21:07:14.157Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Microsoft Exchange Server 2016 Cumulative Update 23",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "15.01.2507.032",
              "status": "affected",
              "version": "15.01.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Microsoft Exchange Server 2019 Cumulative Update 12",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "15.02.1118.037",
              "status": "affected",
              "version": "15.02.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Microsoft Exchange Server 2019 Cumulative Update 13",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "15.02.1258.025",
              "status": "affected",
              "version": "15.02.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:microsoft:exchange_server:*:cumulative_update_12:*:*:*:*:*:*",
                  "versionEndExcluding": "15.02.1118.037",
                  "versionStartIncluding": "15.02.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:exchange_server_2016:*:cumulative_update_23:*:*:*:*:*:*",
                  "versionEndExcluding": "15.01.2507.032",
                  "versionStartIncluding": "15.01.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:exchange_server:*:cumulative_update_13:*:*:*:*:*:*",
                  "versionEndExcluding": "15.02.1258.025",
                  "versionStartIncluding": "15.02.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "datePublic": "2023-08-08T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en-US",
          "value": "Microsoft Exchange Server Elevation of Privilege Vulnerability"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307: Improper Restriction of Excessive Authentication Attempts",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-08-10T15:11:18.136Z",
        "orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
        "shortName": "microsoft"
      },
      "references": [
        {
          "name": "Microsoft Exchange Server Elevation of Privilege Vulnerability",
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2023-21709"
        }
      ],
      "title": "Microsoft Exchange Server Elevation of Privilege Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
    "assignerShortName": "microsoft",
    "cveId": "CVE-2023-21709",
    "datePublished": "2023-08-08T17:08:46.247Z",
    "dateReserved": "2022-12-13T18:08:03.490Z",
    "dateUpdated": "2026-08-10T15:11:18.136Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2023-6928 (GCVE-0-2023-6928)

Vulnerability from cvelistv5 – Published: 2023-12-19 22:58 – Updated: 2024-08-02 08:42
VLAI
Title
Improper Restriction of Excessive Authentication Attempts
Summary
EuroTel ETL3100 versions v01c01 and v01x37 does not limit the number of attempts to guess administrative credentials in remote password attacks to gain full control of the system.
CWE
  • CWE-307 - Improper Restriction of Excessive Authentication Attempts
References
Impacted products
Vendor Product Version
EuroTel ETL3100 Affected: v01c01
Affected: v01x37
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:42:08.687Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-353-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ETL3100",
          "vendor": "EuroTel",
          "versions": [
            {
              "status": "affected",
              "version": "v01c01"
            },
            {
              "status": "affected",
              "version": "v01x37"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Gjoko Krstic"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eEuroTel ETL3100 versions v01c01 and v01x37 does not limit the number of attempts to guess administrative credentials in remote password attacks to gain full control of the system.\u003c/p\u003e\u003cbr\u003e\n\n"
            }
          ],
          "value": "\nEuroTel ETL3100 versions v01c01 and v01x37 does not limit the number of attempts to guess administrative credentials in remote password attacks to gain full control of the system.\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-12-19T22:58:50.824Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-353-05"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Improper Restriction of Excessive Authentication Attempts",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-6928",
    "datePublished": "2023-12-19T22:58:50.824Z",
    "dateReserved": "2023-12-18T17:18:31.806Z",
    "dateUpdated": "2024-08-02T08:42:08.687Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-6912 (GCVE-0-2023-6912)

Vulnerability from cvelistv5 – Published: 2023-12-20 09:35 – Updated: 2026-02-23 10:07
VLAI
Title
Brute force vulnerability in M-Files user authentication
Summary
Lack of protection against brute force attacks in M-Files Server before 23.12.13205.0 allows an attacker unlimited authentication attempts, potentially compromising targeted M-Files user accounts by guessing passwords.
CWE
  • CWE-307 - Improper Restriction of Excessive Authentication Attempts
Impacted products
Vendor Product Version
M-Files Corporation M-Files Server Affected: 0 , < 23.12.13205.0 (custom)
Unaffected: 23.2 LTS SR6
Unaffected: 23.8 LTS SR4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:42:08.504Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.m-files.com/about/trust-center/security-advisories/cve-2023-6912/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "M-Files Server",
          "vendor": "M-Files Corporation",
          "versions": [
            {
              "lessThan": "23.12.13205.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "23.2 LTS SR6"
            },
            {
              "status": "unaffected",
              "version": "23.8 LTS SR4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Lack of protection against brute force attacks in M-Files Server before 23.12.13205.0 allows an attacker unlimited authentication attempts, potentially compromising targeted M-Files user accounts by guessing passwords.\u003cbr\u003e"
            }
          ],
          "value": "Lack of protection against brute force attacks in M-Files Server before 23.12.13205.0 allows an attacker unlimited authentication attempts, potentially compromising targeted M-Files user accounts by guessing passwords."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-49",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-49: Password Brute Forcing"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307: Improper Restriction of Excessive Authentication Attempts",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-23T10:07:53.064Z",
        "orgId": "bcf7a16e-bfdc-46e4-9e42-4187da3f4410",
        "shortName": "M-Files Corporation"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://product.m-files.com/security-advisories/cve-2023-6912/"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://empower.m-files.com/security-advisories/CVE-2023-6912"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Update to patched version.\u003cbr\u003e"
            }
          ],
          "value": "Update to patched version."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Brute force vulnerability in M-Files user authentication",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bcf7a16e-bfdc-46e4-9e42-4187da3f4410",
    "assignerShortName": "M-Files Corporation",
    "cveId": "CVE-2023-6912",
    "datePublished": "2023-12-20T09:35:46.232Z",
    "dateReserved": "2023-12-18T08:33:42.158Z",
    "dateUpdated": "2026-02-23T10:07:53.064Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2023-6756 (GCVE-0-2023-6756)

Vulnerability from cvelistv5 – Published: 2023-12-13 13:31 – Updated: 2024-08-02 08:42
VLAI
Title
Thecosy IceCMS Captcha login excessive authentication
Summary
A vulnerability was found in Thecosy IceCMS 2.0.1. It has been classified as problematic. Affected is an unknown function of the file /login of the component Captcha Handler. The manipulation leads to improper restriction of excessive authentication attempts. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-247884.
CWE
  • CWE-307 - Improper Restriction of Excessive Authentication Attempts
References
Impacted products
Vendor Product Version
Thecosy IceCMS Affected: 2.0.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:42:07.179Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.247884"
          },
          {
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.247884"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "http://124.71.147.32:8082/IceCMS2.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Captcha Handler"
          ],
          "product": "IceCMS",
          "vendor": "Thecosy",
          "versions": [
            {
              "status": "affected",
              "version": "2.0.1"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "analyst",
          "value": "YuJiu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Thecosy IceCMS 2.0.1. It has been classified as problematic. Affected is an unknown function of the file /login of the component Captcha Handler. The manipulation leads to improper restriction of excessive authentication attempts. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-247884."
        },
        {
          "lang": "de",
          "value": "Es wurde eine problematische Schwachstelle in Thecosy IceCMS 2.0.1 ausgemacht. Betroffen hiervon ist ein unbekannter Ablauf der Datei /login der Komponente Captcha Handler. Durch Beeinflussen mit unbekannten Daten kann eine improper restriction of excessive authentication attempts-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-12-13T13:31:03.944Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.247884"
        },
        {
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.247884"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "http://124.71.147.32:8082/IceCMS2.html"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2023-12-13T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2023-12-13T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2023-12-13T08:45:15.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Thecosy IceCMS Captcha login excessive authentication"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2023-6756",
    "datePublished": "2023-12-13T13:31:03.944Z",
    "dateReserved": "2023-12-13T07:39:44.413Z",
    "dateUpdated": "2024-08-02T08:42:07.179Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-5754 (GCVE-0-2023-5754)

Vulnerability from cvelistv5 – Published: 2023-10-26 19:47 – Updated: 2025-01-16 21:27
VLAI
Title
Improper Restriction of Excessive Authentication Attempts in Sielco PolyEco1000
Summary
Sielco PolyEco1000 uses a weak set of default administrative credentials that can be easily guessed in remote password attacks and gain full control of the system.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-16 21:22 UTC
CWE
  • CWE-307 - Improper Restriction of Excessive Authentication Attempts
Impacted products
Vendor Product Version
Sielco PolyEco1000 Affected: CPU:2.0.6 FPGA:10.19
Affected: CPU:1.9.4 FPGA:10.19
Affected: CPU:1.9.3 FPGA:10.19
Affected: CPU:1.7.0 FPGA:10.16
Affected: CPU:2.0.2 FPGA:10.19
Affected: CPU:2.0.0 FPGA:10.19
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:07:32.658Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-299-07"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-5754",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T21:22:31.175439Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:27:38.467Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PolyEco1000",
          "vendor": "Sielco ",
          "versions": [
            {
              "status": "affected",
              "version": "CPU:2.0.6 FPGA:10.19"
            },
            {
              "status": "affected",
              "version": "CPU:1.9.4 FPGA:10.19"
            },
            {
              "status": "affected",
              "version": "CPU:1.9.3 FPGA:10.19"
            },
            {
              "status": "affected",
              "version": "CPU:1.7.0 FPGA:10.16"
            },
            {
              "status": "affected",
              "version": "CPU:2.0.2 FPGA:10.19"
            },
            {
              "status": "affected",
              "version": "CPU:2.0.0 FPGA:10.19"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": " Gjoko Krstic"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003eSielco PolyEco1000 uses a weak set of default administrative credentials that can be easily guessed in remote password attacks and gain full control of the system.\u003c/p\u003e\u003cbr\u003e\n\n\u003cbr\u003e\n\n"
            }
          ],
          "value": "\n\n\n\n\nSielco PolyEco1000 uses a weak set of default administrative credentials that can be easily guessed in remote password attacks and gain full control of the system.\n\n\n\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-26T19:47:06.226Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-299-07"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Improper Restriction of Excessive Authentication Attempts in Sielco PolyEco1000",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-5754",
    "datePublished": "2023-10-26T19:47:06.226Z",
    "dateReserved": "2023-10-24T16:24:16.565Z",
    "dateUpdated": "2025-01-16T21:27:38.467Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-4625 (GCVE-0-2023-4625)

Vulnerability from cvelistv5 – Published: 2023-11-06 04:57 – Updated: 2025-02-27 20:34
VLAI
Title
Denial-of-Service(DoS) Vulnerability in Web server function on MELSEC Series CPU module
Summary
Improper Restriction of Excessive Authentication Attempts vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F/iQ-R Series CPU modules Web server function allows a remote unauthenticated attacker to prevent legitimate users from logging into the Web server function for a certain period after the attacker has attempted to log in illegally by continuously attempting unauthorized login to the Web server function. The impact of this vulnerability will persist while the attacker continues to attempt unauthorized login.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-26 21:49 UTC
CWE
  • CWE-307 - Improper Restriction of Excessive Authentication Attempts
References
Impacted products
Vendor Product Version
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MT/ES Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MT/ES Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MT/ES Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MR/ES Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MR/ES Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MR/ES Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MT/DS Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MT/DS Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MT/DS Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MR/DS Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MR/DS Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MR/DS Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MT/ESS Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MT/ESS Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MT/ESS Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MT/DSS Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MT/DSS Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MT/DSS Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/D Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-64MT/D Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-96MT/D Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DSS Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-64MT/DSS Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-96MT/DSS Affected: all versions (for serial number 17X**** and later)
Affected: 1.060 or later (for serial number 179**** and prior)
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DS-TS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DSS-TS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MR/DS-TS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MT/ES Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MT/ES Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MT/ES Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MR/ES Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MR/ES Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MR/ES Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MT/ESS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MT/ESS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MT/ESS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MT/DS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MT/DS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MT/DS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MR/DS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MR/DS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MR/DS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MT/DSS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MT/DSS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MT/DSS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MT/ES-A Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MT/ES-A Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MT/ES-A Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MR/ES-A Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MR/ES-A Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MR/ES-A Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-30MT/ES Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-40MT/ES Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-60MT/ES Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-80MT/ES Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-30MR/ES Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-40MR/ES Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-60MR/ES Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-80MR/ES Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-30MT/ESS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-40MT/ESS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-60MT/ESS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-80MT/ESS Affected: all versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R00CPU Affected: versions 05 or later
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R01CPU Affected: versions 05 or later
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R02CPU Affected: versions 05 or later
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R04CPU Affected: versions 35 or later
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R08CPU Affected: versions 35 or later
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R16CPU Affected: versions 35 or later
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R32CPU Affected: versions 35 or later
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R120CPU Affected: versions 35 or later
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R04ENCPU Affected: versions 35 or later
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R08ENCPU Affected: versions 35 or later
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R16ENCPU Affected: versions 35 or later
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R32ENCPU Affected: versions 35 or later
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R120ENCPU Affected: versions 35 or later
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R08PCPU Affected: versions 37 or later
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R16PCPU Affected: versions 37 or later
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R32PCPU Affected: versions 37 or later
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-R Series R120PCPU Affected: versions 37 or later
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:31:06.570Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-014_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU94620134"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-306-02"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-4625",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-26T21:49:50.263922Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-27T20:34:25.710Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-32MT/D",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-64MT/D",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-96MT/D",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-32MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-64MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-96MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions (for serial number 17X**** and later)"
            },
            {
              "status": "affected",
              "version": "1.060 or later (for serial number 179**** and prior)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-32MT/DS-TS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-32MT/DSS-TS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-32MR/DS-TS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-30MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-40MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-60MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-80MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-30MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-40MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-60MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-80MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-30MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-40MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-60MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-80MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R00CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 05 or later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R01CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 05 or later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R02CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 05 or later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R04CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 35 or later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R08CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 35 or later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R16CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 35 or later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R32CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 35 or later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R120CPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 35 or later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R04ENCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 35 or later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R08ENCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 35 or later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R16ENCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 35 or later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R32ENCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 35 or later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R120ENCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 35 or later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R08PCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 37 or later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R16PCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 37 or later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R32PCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 37 or later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series R120PCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 37 or later"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Restriction of Excessive Authentication Attempts vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F/iQ-R Series CPU modules Web server function allows a remote unauthenticated attacker to prevent legitimate users from logging into the Web server function for a certain period after the attacker has attempted to log in illegally by continuously attempting unauthorized login to the Web server function. The impact of this vulnerability will persist while the attacker continues to attempt unauthorized login."
            }
          ],
          "value": "Improper Restriction of Excessive Authentication Attempts vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F/iQ-R Series CPU modules Web server function allows a remote unauthenticated attacker to prevent legitimate users from logging into the Web server function for a certain period after the attacker has attempted to log in illegally by continuously attempting unauthorized login to the Web server function. The impact of this vulnerability will persist while the attacker continues to attempt unauthorized login."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Denial of Service(DoS)"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-15T05:17:45.711Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-014_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU94620134"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-306-02"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Denial-of-Service\uff08DoS\uff09 Vulnerability in Web server function on MELSEC Series CPU module",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2023-4625",
    "datePublished": "2023-11-06T04:57:44.446Z",
    "dateReserved": "2023-08-30T12:11:44.835Z",
    "dateUpdated": "2025-02-27T20:34:25.710Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation
Architecture and Design
  • Common protection mechanisms include:
  • Disconnecting the user after a small number of failed attempts
  • Implementing a timeout
  • Locking out a targeted account
  • Requiring a computational task on the user's part.
Mitigation MIT-4
Architecture and Design

Strategy: Libraries or Frameworks

  • Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid [REF-1482].
  • Consider using libraries with authentication capabilities such as OpenSSL or the ESAPI Authenticator. [REF-45]
CAPEC-16: Dictionary-based Password Attack

An attacker tries each of the words in a dictionary as passwords to gain access to the system via some user's account. If the password chosen by the user was a word within the dictionary, this attack will be successful (in the absence of other mitigations). This is a specific instance of the password brute forcing attack pattern.

Dictionary Attacks differ from similar attacks such as Password Spraying (CAPEC-565) and Credential Stuffing (CAPEC-600), since they leverage unknown username/password combinations and don't care about inducing account lockouts.

CAPEC-49: Password Brute Forcing

An adversary tries every possible value for a password until they succeed. A brute force attack, if feasible computationally, will always be successful because it will essentially go through all possible passwords given the alphabet used (lower case letters, upper case letters, numbers, symbols, etc.) and the maximum length of the password.

CAPEC-560: Use of Known Domain Credentials

An adversary guesses or obtains (i.e. steals or purchases) legitimate credentials (e.g. userID/password) to achieve authentication and to perform authorized actions under the guise of an authenticated user or service.

CAPEC-565: Password Spraying

In a Password Spraying attack, an adversary tries a small list (e.g. 3-5) of common or expected passwords, often matching the target's complexity policy, against a known list of user accounts to gain valid credentials. The adversary tries a particular password for each user account, before moving onto the next password in the list. This approach assists the adversary in remaining undetected by avoiding rapid or frequent account lockouts. The adversary may then reattempt the process with additional passwords, once enough time has passed to prevent inducing a lockout.

CAPEC-600: Credential Stuffing

An adversary tries known username/password combinations against different systems, applications, or services to gain additional authenticated access. Credential Stuffing attacks rely upon the fact that many users leverage the same username/password combination for multiple systems, applications, and services.

CAPEC-652: Use of Known Kerberos Credentials

An adversary obtains (i.e. steals or purchases) legitimate Kerberos credentials (e.g. Kerberos service account userID/password or Kerberos Tickets) with the goal of achieving authenticated access to additional systems, applications, or services within the domain.

CAPEC-653: Use of Known Operating System Credentials

An adversary guesses or obtains (i.e. steals or purchases) legitimate operating system credentials (e.g. userID/password) to achieve authentication and to perform authorized actions on the system, under the guise of an authenticated user or service. This applies to any Operating System.