CWE-121
Stack-based Buffer Overflow
A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).
CVE-2024-2546 (GCVE-0-2024-2546)
Vulnerability from cvelistv5 – Published: 2024-03-17 01:31 – Updated: 2024-08-01 19:18
VLAI
Title
Tenda AC18 fromSetWirelessRepeat stack-based overflow
Summary
A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.256999 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.256999 | signaturepermissions-required |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC18 |
Affected:
15.13.07.09
|
|
| tenda | ac18_firmware |
Affected:
15.13.07.09
cpe:2.3:o:tenda:ac18_firmware:15.13.07.09:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.13.07.09:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.13.07.09"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2546",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-16T21:06:00.663025Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-16T21:06:58.371Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:47.953Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-256999 | Tenda AC18 fromSetWirelessRepeat stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.256999"
},
{
"name": "VDB-256999 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.256999"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/A18/fromSetWirelessRepeat_a.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.13.07.09"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_backup (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda AC18 15.13.07.09 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Hierbei betrifft es die Funktion fromSetWirelessRepeat. Mittels Manipulieren des Arguments wpapsk_crypto5g mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-17T01:31:04.350Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-256999 | Tenda AC18 fromSetWirelessRepeat stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.256999"
},
{
"name": "VDB-256999 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.256999"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/A18/fromSetWirelessRepeat_a.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-16T08:00:43.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC18 fromSetWirelessRepeat stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2546",
"datePublished": "2024-03-17T01:31:04.350Z",
"dateReserved": "2024-03-15T20:04:21.580Z",
"dateUpdated": "2024-08-01T19:18:47.953Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2547 (GCVE-0-2024-2547)
Vulnerability from cvelistv5 – Published: 2024-03-17 03:31 – Updated: 2024-08-21 15:16
VLAI
Title
Tenda AC18 R7WebsSecurityHandler stack-based overflow
Summary
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.257000 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.257000 | signaturepermissions-required |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC18 |
Affected:
15.03.05.05
|
|
| tenda | ac18_firmware |
Affected:
15.03.05.05
cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.212Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257000 | Tenda AC18 R7WebsSecurityHandler stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257000"
},
{
"name": "VDB-257000 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257000"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/R7WebsSecurityHandler.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2547",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-21T15:14:45.903222Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T15:16:52.674Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_backup (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC18 15.03.05.05 gefunden. Sie wurde als kritisch eingestuft. Davon betroffen ist die Funktion R7WebsSecurityHandler. Durch das Manipulieren des Arguments password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-17T03:31:03.829Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257000 | Tenda AC18 R7WebsSecurityHandler stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257000"
},
{
"name": "VDB-257000 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257000"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/R7WebsSecurityHandler.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-15T21:09:51.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC18 R7WebsSecurityHandler stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2547",
"datePublished": "2024-03-17T03:31:03.829Z",
"dateReserved": "2024-03-15T20:04:28.272Z",
"dateUpdated": "2024-08-21T15:16:52.674Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2558 (GCVE-0-2024-2558)
Vulnerability from cvelistv5 – Published: 2024-03-17 09:00 – Updated: 2024-08-02 17:32
VLAI
Title
Tenda AC18 execCommand formexeCommand stack-based overflow
Summary
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.257057 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.257057 | signaturepermissions-required |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC18 |
Affected:
15.03.05.05
|
|
| tenda | ac18_firmware |
Affected:
15.03.05.05
cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:47.827Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257057 | Tenda AC18 execCommand formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257057"
},
{
"name": "VDB-257057 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257057"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formexeCommand.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2558",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-18T15:37:52.626613Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-02T17:32:11.576Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_backup (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC18 15.03.05.05 ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion formexeCommand der Datei /goform/execCommand. Durch das Beeinflussen des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-17T09:00:07.516Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257057 | Tenda AC18 execCommand formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257057"
},
{
"name": "VDB-257057 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257057"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formexeCommand.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-16T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-16T07:59:36.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC18 execCommand formexeCommand stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2558",
"datePublished": "2024-03-17T09:00:07.516Z",
"dateReserved": "2024-03-16T06:54:24.270Z",
"dateUpdated": "2024-08-02T17:32:11.576Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2581 (GCVE-0-2024-2581)
Vulnerability from cvelistv5 – Published: 2024-03-18 03:00 – Updated: 2024-08-02 15:29
VLAI
Title
Tenda AC10 SetStaticRouteCfg fromSetRouteStatic stack-based overflow
Summary
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.257081 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.257081 | signaturepermissions-required |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC10 |
Affected:
16.03.10.13
|
|
| tenda | ac10_firmware |
Affected:
16.03.10.13
cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.191Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257081 | Tenda AC10 SetStaticRouteCfg fromSetRouteStatic stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257081"
},
{
"name": "VDB-257081 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257081"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10/V16.03.10.13/fromSetRouteStatic.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.03.10.13"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2581",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-02T15:28:30.954053Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-02T15:29:50.674Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "16.03.10.13"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_backup (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC10 16.03.10.13 gefunden. Es geht hierbei um die Funktion fromSetRouteStatic der Datei /goform/SetStaticRouteCfg. Dank der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-18T03:00:06.600Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257081 | Tenda AC10 SetStaticRouteCfg fromSetRouteStatic stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257081"
},
{
"name": "VDB-257081 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257081"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10/V16.03.10.13/fromSetRouteStatic.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-17T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-17T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-17T17:42:14.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10 SetStaticRouteCfg fromSetRouteStatic stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2581",
"datePublished": "2024-03-18T03:00:06.600Z",
"dateReserved": "2024-03-17T16:37:02.849Z",
"dateUpdated": "2024-08-02T15:29:50.674Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-26010 (GCVE-0-2024-26010)
Vulnerability from cvelistv5 – Published: 2024-06-11 14:32 – Updated: 2025-08-27 20:42
VLAI
Summary
A stack-based buffer overflow in Fortinet FortiPAM version 1.2.0, 1.1.0 through 1.1.2, 1.0.0 through 1.0.3, FortiWeb, FortiAuthenticator, FortiSwitchManager version 7.2.0 through 7.2.3, 7.0.1 through 7.0.3, FortiOS version 7.4.0 through 7.4.3, 7.2.0 through 7.2.7, 7.0.0 through 7.0.14, 6.4.0 through 6.4.15, 6.2.0 through 6.2.16, 6.0.0 through 6.0.18, FortiProxy version 7.4.0 through 7.4.2, 7.2.0 through 7.2.9, 7.0.0 through 7.0.15, 2.0.0 through 2.0.13, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7 allows attacker to execute unauthorized code or commands via specially crafted packets.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Execute unauthorized code or commands
Assigner
References
1 reference
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Fortinet | FortiPAM |
Affected:
1.2.0
Affected: 1.1.0 , ≤ 1.1.2 (semver) Affected: 1.0.0 , ≤ 1.0.3 (semver) |
|
| Fortinet | FortiSwitchManager |
Affected:
7.2.0 , ≤ 7.2.3
(semver)
Affected: 7.0.1 , ≤ 7.0.3 (semver) |
|
| Fortinet | FortiOS |
Affected:
7.4.0 , ≤ 7.4.3
(semver)
Affected: 7.2.0 , ≤ 7.2.7 (semver) Affected: 7.0.0 , ≤ 7.0.14 (semver) Affected: 6.4.0 , ≤ 6.4.15 (semver) Affected: 6.2.0 , ≤ 6.2.16 (semver) Affected: 6.0.0 , ≤ 6.0.18 (semver) |
|
| Fortinet | FortiProxy |
Affected:
7.4.0 , ≤ 7.4.2
(semver)
Affected: 7.2.0 , ≤ 7.2.9 (semver) Affected: 7.0.0 , ≤ 7.0.15 (semver) Affected: 2.0.0 , ≤ 2.0.13 (semver) Affected: 1.2.0 , ≤ 1.2.13 (semver) Affected: 1.1.0 , ≤ 1.1.6 (semver) Affected: 1.0.0 , ≤ 1.0.7 (semver) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-26010",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-26T19:13:43.887425Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:53.674Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:59:31.322Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://fortiguard.fortinet.com/psirt/FG-IR-24-036",
"tags": [
"x_transferred"
],
"url": "https://fortiguard.fortinet.com/psirt/FG-IR-24-036"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FortiPAM",
"vendor": "Fortinet",
"versions": [
{
"status": "affected",
"version": "1.2.0"
},
{
"lessThanOrEqual": "1.1.2",
"status": "affected",
"version": "1.1.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "1.0.3",
"status": "affected",
"version": "1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FortiSwitchManager",
"vendor": "Fortinet",
"versions": [
{
"lessThanOrEqual": "7.2.3",
"status": "affected",
"version": "7.2.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "7.0.3",
"status": "affected",
"version": "7.0.1",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FortiOS",
"vendor": "Fortinet",
"versions": [
{
"lessThanOrEqual": "7.4.3",
"status": "affected",
"version": "7.4.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "7.2.7",
"status": "affected",
"version": "7.2.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "7.0.14",
"status": "affected",
"version": "7.0.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "6.4.15",
"status": "affected",
"version": "6.4.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "6.2.16",
"status": "affected",
"version": "6.2.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "6.0.18",
"status": "affected",
"version": "6.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FortiProxy",
"vendor": "Fortinet",
"versions": [
{
"lessThanOrEqual": "7.4.2",
"status": "affected",
"version": "7.4.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "7.2.9",
"status": "affected",
"version": "7.2.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "7.0.15",
"status": "affected",
"version": "7.0.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "2.0.13",
"status": "affected",
"version": "2.0.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "1.2.13",
"status": "affected",
"version": "1.2.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "1.1.6",
"status": "affected",
"version": "1.1.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "1.0.7",
"status": "affected",
"version": "1.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A stack-based buffer overflow in Fortinet FortiPAM version 1.2.0, 1.1.0 through 1.1.2, 1.0.0 through 1.0.3, FortiWeb, FortiAuthenticator, FortiSwitchManager version 7.2.0 through 7.2.3, 7.0.1 through 7.0.3, FortiOS version 7.4.0 through 7.4.3, 7.2.0 through 7.2.7, 7.0.0 through 7.0.14, 6.4.0 through 6.4.15, 6.2.0 through 6.2.16, 6.0.0 through 6.0.18, FortiProxy version 7.4.0 through 7.4.2, 7.2.0 through 7.2.9, 7.0.0 through 7.0.15, 2.0.0 through 2.0.13, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7 allows attacker to execute unauthorized code or commands via specially crafted packets."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:U/RL:W/RC:C",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Execute unauthorized code or commands",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:32:03.697Z",
"orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
"shortName": "fortinet"
},
"references": [
{
"name": "https://fortiguard.fortinet.com/psirt/FG-IR-24-036",
"url": "https://fortiguard.fortinet.com/psirt/FG-IR-24-036"
}
],
"solutions": [
{
"lang": "en",
"value": "Please upgrade to FortiPAM version 1.3.0 or above \nPlease upgrade to FortiAuthenticator version 7.0.0 or above \nPlease upgrade to FortiWeb version 7.6.0 or above \nPlease upgrade to FortiWeb version 7.4.3 or above \nPlease upgrade to FortiVoice version 7.0.2 or above \nPlease upgrade to FortiVoice version 6.4.9 or above \nPlease upgrade to FortiSwitchManager version 7.2.4 or above \nPlease upgrade to FortiSwitchManager version 7.0.4 or above \nPlease upgrade to FortiOS version 7.4.4 or above \nPlease upgrade to FortiOS version 7.2.8 or above \nPlease upgrade to FortiOS version 7.0.15 or above \nPlease upgrade to FortiProxy version 7.4.4 or above \nPlease upgrade to FortiProxy version 7.2.10 or above \n"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
"assignerShortName": "fortinet",
"cveId": "CVE-2024-26010",
"datePublished": "2024-06-11T14:32:03.697Z",
"dateReserved": "2024-02-14T09:18:43.245Z",
"dateUpdated": "2025-08-27T20:42:53.674Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-26180 (GCVE-0-2024-26180)
Vulnerability from cvelistv5 – Published: 2024-04-09 17:00 – Updated: 2025-05-03 00:39
VLAI
Title
Secure Boot Security Feature Bypass Vulnerability
Summary
Secure Boot Security Feature Bypass Vulnerability
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://msrc.microsoft.com/update-guide/vulnerabi… | vendor-advisory |
Impacted products
20 products
| Vendor | Product | Version | |
|---|---|---|---|
| Microsoft | Windows 10 Version 1809 |
Affected:
10.0.17763.0 , < 10.0.17763.5696
(custom)
|
|
| Microsoft | Windows 10 Version 1809 |
Affected:
10.0.0 , < 10.0.17763.5696
(custom)
|
|
| Microsoft | Windows Server 2019 |
Affected:
10.0.17763.0 , < 10.0.17763.5696
(custom)
|
|
| Microsoft | Windows Server 2019 (Server Core installation) |
Affected:
10.0.17763.0 , < 10.0.17763.5696
(custom)
|
|
| Microsoft | Windows Server 2022 |
Affected:
10.0.20348.0 , < 10.0.20348.2402
(custom)
|
|
| Microsoft | Windows 11 version 21H2 |
Affected:
10.0.0 , < 10.0.22000.2899
(custom)
|
|
| Microsoft | Windows 10 Version 21H2 |
Affected:
10.0.19043.0 , < 10.0.19044.4291
(custom)
|
|
| Microsoft | Windows 11 version 22H2 |
Affected:
10.0.22621.0 , < 10.0.22621.3447
(custom)
|
|
| Microsoft | Windows 10 Version 22H2 |
Affected:
10.0.19045.0 , < 10.0.19045.4291
(custom)
|
|
| Microsoft | Windows 11 version 22H3 |
Affected:
10.0.22631.0 , < 10.0.22631.3447
(custom)
|
|
| Microsoft | Windows 11 Version 23H2 |
Affected:
10.0.22631.0 , < 10.0.22631.3447
(custom)
|
|
| Microsoft | Windows Server 2022, 23H2 Edition (Server Core installation) |
Affected:
10.0.25398.0 , < 10.0.25398.830
(custom)
|
|
| Microsoft | Windows 10 Version 1507 |
Affected:
10.0.10240.0 , < 10.0.10240.20596
(custom)
|
|
| Microsoft | Windows 10 Version 1607 |
Affected:
10.0.14393.0 , < 10.0.14393.6897
(custom)
|
|
| Microsoft | Windows Server 2016 |
Affected:
10.0.14393.0 , < 10.0.14393.6897
(custom)
|
|
| Microsoft | Windows Server 2016 (Server Core installation) |
Affected:
10.0.14393.0 , < 10.0.14393.6897
(custom)
|
|
| Microsoft | Windows Server 2012 |
Affected:
6.2.9200.0 , < 6.2.9200.24821
(custom)
|
|
| Microsoft | Windows Server 2012 (Server Core installation) |
Affected:
6.2.9200.0 , < 6.2.9200.24821
(custom)
|
|
| Microsoft | Windows Server 2012 R2 |
Affected:
6.3.9600.0 , < 6.3.9600.21924
(custom)
|
|
| Microsoft | Windows Server 2012 R2 (Server Core installation) |
Affected:
6.3.9600.0 , < 6.3.9600.21924
(custom)
|
Date Public
2024-04-09 07:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-26180",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-28T14:09:48.714547Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-28T14:09:53.962Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:59:32.623Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "Secure Boot Security Feature Bypass Vulnerability",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2024-26180"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"platforms": [
"32-bit Systems",
"x64-based Systems"
],
"product": "Windows 10 Version 1809",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.17763.5696",
"status": "affected",
"version": "10.0.17763.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"ARM64-based Systems"
],
"product": "Windows 10 Version 1809",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.17763.5696",
"status": "affected",
"version": "10.0.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2019",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.17763.5696",
"status": "affected",
"version": "10.0.17763.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2019 (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.17763.5696",
"status": "affected",
"version": "10.0.17763.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2022",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.20348.2402",
"status": "affected",
"version": "10.0.20348.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems",
"ARM64-based Systems"
],
"product": "Windows 11 version 21H2",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.22000.2899",
"status": "affected",
"version": "10.0.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"32-bit Systems",
"ARM64-based Systems",
"x64-based Systems"
],
"product": "Windows 10 Version 21H2",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.19044.4291",
"status": "affected",
"version": "10.0.19043.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"ARM64-based Systems",
"x64-based Systems"
],
"product": "Windows 11 version 22H2",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.22621.3447",
"status": "affected",
"version": "10.0.22621.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems",
"ARM64-based Systems",
"32-bit Systems"
],
"product": "Windows 10 Version 22H2",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.19045.4291",
"status": "affected",
"version": "10.0.19045.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"ARM64-based Systems"
],
"product": "Windows 11 version 22H3",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.22631.3447",
"status": "affected",
"version": "10.0.22631.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows 11 Version 23H2",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.22631.3447",
"status": "affected",
"version": "10.0.22631.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2022, 23H2 Edition (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.25398.830",
"status": "affected",
"version": "10.0.25398.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"32-bit Systems",
"x64-based Systems"
],
"product": "Windows 10 Version 1507",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.10240.20596",
"status": "affected",
"version": "10.0.10240.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"32-bit Systems",
"x64-based Systems"
],
"product": "Windows 10 Version 1607",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.14393.6897",
"status": "affected",
"version": "10.0.14393.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2016",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.14393.6897",
"status": "affected",
"version": "10.0.14393.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2016 (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.14393.6897",
"status": "affected",
"version": "10.0.14393.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2012",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "6.2.9200.24821",
"status": "affected",
"version": "6.2.9200.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2012 (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "6.2.9200.24821",
"status": "affected",
"version": "6.2.9200.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2012 R2",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "6.3.9600.21924",
"status": "affected",
"version": "6.3.9600.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2012 R2 (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "6.3.9600.21924",
"status": "affected",
"version": "6.3.9600.0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows_10_1809:*:*:*:*:*:*:x86:*",
"versionEndExcluding": "10.0.17763.5696",
"versionStartIncluding": "10.0.17763.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_10_1809:*:*:*:*:*:*:arm64:*",
"versionEndExcluding": "10.0.17763.5696",
"versionStartIncluding": "10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.17763.5696",
"versionStartIncluding": "10.0.17763.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.17763.5696",
"versionStartIncluding": "10.0.17763.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2022:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.20348.2402",
"versionStartIncluding": "10.0.20348.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_11_21H2:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "10.0.22000.2899",
"versionStartIncluding": "10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_10_21H2:*:*:*:*:*:*:x86:*",
"versionEndExcluding": "10.0.19044.4291",
"versionStartIncluding": "10.0.19043.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_11_22H2:*:*:*:*:*:*:arm64:*",
"versionEndExcluding": "10.0.22621.3447",
"versionStartIncluding": "10.0.22621.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_10_22H2:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "10.0.19045.4291",
"versionStartIncluding": "10.0.19045.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_11_23H2:*:*:*:*:*:*:arm64:*",
"versionEndExcluding": "10.0.22631.3447",
"versionStartIncluding": "10.0.22631.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_11_23H2:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "10.0.22631.3447",
"versionStartIncluding": "10.0.22631.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_23h2:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.25398.830",
"versionStartIncluding": "10.0.25398.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_10_1507:*:*:*:*:*:*:x86:*",
"versionEndExcluding": "10.0.10240.20596",
"versionStartIncluding": "10.0.10240.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_10_1607:*:*:*:*:*:*:x86:*",
"versionEndExcluding": "10.0.14393.6897",
"versionStartIncluding": "10.0.14393.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.14393.6897",
"versionStartIncluding": "10.0.14393.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.14393.6897",
"versionStartIncluding": "10.0.14393.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2012:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "6.2.9200.24821",
"versionStartIncluding": "6.2.9200.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2012:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "6.2.9200.24821",
"versionStartIncluding": "6.2.9200.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2012_R2:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "6.3.9600.21924",
"versionStartIncluding": "6.3.9600.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2012_R2:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "6.3.9600.21924",
"versionStartIncluding": "6.3.9600.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"datePublic": "2024-04-09T07:00:00.000Z",
"descriptions": [
{
"lang": "en-US",
"value": "Secure Boot Security Feature Bypass Vulnerability"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-03T00:39:42.157Z",
"orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
"shortName": "microsoft"
},
"references": [
{
"name": "Secure Boot Security Feature Bypass Vulnerability",
"tags": [
"vendor-advisory"
],
"url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2024-26180"
}
],
"title": "Secure Boot Security Feature Bypass Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
"assignerShortName": "microsoft",
"cveId": "CVE-2024-26180",
"datePublished": "2024-04-09T17:00:43.282Z",
"dateReserved": "2024-02-14T22:23:54.098Z",
"dateUpdated": "2025-05-03T00:39:42.157Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2703 (GCVE-0-2024-2703)
Vulnerability from cvelistv5 – Published: 2024-03-20 16:00 – Updated: 2024-08-21 23:00
VLAI
Title
Tenda AC10U SetOnlineDevName formSetDeviceName stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49. Affected is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257454 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.257454 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.257454 | signaturepermissions-required |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC10U |
Affected:
15.03.06.49
|
|
| tenda | ac10u_firmware |
Affected:
15.03.06.49
cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2703",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-16T21:07:16.955935Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T23:00:23.349Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.260Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257454 | Tenda AC10U SetOnlineDevName formSetDeviceName stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257454"
},
{
"name": "VDB-257454 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257454"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formSetDeviceName_mac.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49. Affected is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257454 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda AC10U 15.03.06.49 entdeckt. Betroffen hiervon ist die Funktion formSetDeviceName der Datei /goform/SetOnlineDevName. Durch Beeinflussen des Arguments mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T16:00:06.080Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257454 | Tenda AC10U SetOnlineDevName formSetDeviceName stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257454"
},
{
"name": "VDB-257454 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257454"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formSetDeviceName_mac.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:54:28.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U SetOnlineDevName formSetDeviceName stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2703",
"datePublished": "2024-03-20T16:00:06.080Z",
"dateReserved": "2024-03-20T09:49:23.341Z",
"dateUpdated": "2024-08-21T23:00:23.349Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2704 (GCVE-0-2024-2704)
Vulnerability from cvelistv5 – Published: 2024-03-20 16:00 – Updated: 2024-08-12 18:06
VLAI
Title
Tenda AC10U SetFirewallCfg formSetFirewallCfg stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49. Affected by this vulnerability is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257455. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.257455 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.257455 | signaturepermissions-required |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC10U |
Affected:
15.03.06.49
|
|
| tenda | ac10u_firmware |
Affected:
15.03.06.49
cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.302Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257455 | Tenda AC10U SetFirewallCfg formSetFirewallCfg stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257455"
},
{
"name": "VDB-257455 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257455"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formSetFirewallCfg.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2704",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-12T15:19:20.302733Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-12T18:06:34.407Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49. Affected by this vulnerability is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257455. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda AC10U 15.03.06.49 wurde eine kritische Schwachstelle entdeckt. Es geht um die Funktion formSetFirewallCfg der Datei /goform/SetFirewallCfg. Dank der Manipulation des Arguments firewallEn mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T16:00:07.684Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257455 | Tenda AC10U SetFirewallCfg formSetFirewallCfg stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257455"
},
{
"name": "VDB-257455 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257455"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formSetFirewallCfg.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:54:43.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U SetFirewallCfg formSetFirewallCfg stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2704",
"datePublished": "2024-03-20T16:00:07.684Z",
"dateReserved": "2024-03-20T09:49:39.887Z",
"dateUpdated": "2024-08-12T18:06:34.407Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2705 (GCVE-0-2024-2705)
Vulnerability from cvelistv5 – Published: 2024-03-20 16:31 – Updated: 2024-08-01 19:18
VLAI
Title
Tenda AC10U SetNetControlList formSetQosBand stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.257456 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.257456 | signaturepermissions-required |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:ac10u:1.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2705",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-20T20:07:24.389193Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-18T20:06:01.280Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.341Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257456 | Tenda AC10U SetNetControlList formSetQosBand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257456"
},
{
"name": "VDB-257456 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257456"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formSetQosBand.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0"
},
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC10U 1.0/15.03.06.49 entdeckt. Es geht hierbei um die Funktion formSetQosBand der Datei /goform/SetNetControlList. Dank Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T16:31:04.186Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257456 | Tenda AC10U SetNetControlList formSetQosBand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257456"
},
{
"name": "VDB-257456 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257456"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formSetQosBand.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:54:58.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U SetNetControlList formSetQosBand stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2705",
"datePublished": "2024-03-20T16:31:04.186Z",
"dateReserved": "2024-03-20T09:49:55.324Z",
"dateUpdated": "2024-08-01T19:18:48.341Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2706 (GCVE-0-2024-2706)
Vulnerability from cvelistv5 – Published: 2024-03-20 16:31 – Updated: 2024-08-21 22:59
VLAI
Title
Tenda AC10U WifiWpsStart formWifiWpsStart stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49. This affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257457 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.257457 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.257457 | signaturepermissions-required |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC10U |
Affected:
15.03.06.49
|
|
| tenda | ac10u_firmware |
Affected:
15.03.06.49
cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.271Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257457 | Tenda AC10U WifiWpsStart formWifiWpsStart stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257457"
},
{
"name": "VDB-257457 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257457"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formWifiWpsStart.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2706",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-28T19:02:04.566682Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T22:59:20.274Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49. This affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257457 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda AC10U 15.03.06.49 gefunden. Es geht dabei um die Funktion formWifiWpsStart der Datei /goform/WifiWpsStart. Mit der Manipulation des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T16:31:05.842Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257457 | Tenda AC10U WifiWpsStart formWifiWpsStart stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257457"
},
{
"name": "VDB-257457 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257457"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formWifiWpsStart.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:55:14.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U WifiWpsStart formWifiWpsStart stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2706",
"datePublished": "2024-03-20T16:31:05.842Z",
"dateReserved": "2024-03-20T09:50:11.514Z",
"dateUpdated": "2024-08-21T22:59:20.274Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation ID: MIT-10
Phases: Operation, Build and Compilation
Strategy: Environment Hardening
Description:
- Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
- D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation
Phase: Architecture and Design
Description:
- Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation
Phase: Implementation
Description:
- Implement and perform bounds checking on input.
Mitigation
Phase: Implementation
Description:
- Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.
Mitigation ID: MIT-11
Phases: Operation, Build and Compilation
Strategy: Environment Hardening
Description:
- Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
- Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
- For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].
No CAPEC attack patterns related to this CWE.