CWE-121

Stack-based Buffer Overflow

A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).

CVE-2024-8229 (GCVE-0-2024-8229)

Vulnerability from cvelistv5 – Published: 2024-08-28 00:31 – Updated: 2024-08-28 15:54
VLAI
Title
Tenda O6 operateMacFilter frommacFilterModify stack-based overflow
Summary
A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been declared as critical. This vulnerability affects the function frommacFilterModify of the file /goform/operateMacFilter. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.275938 vdb-entrytechnical-description
https://vuldb.com/?ctiid.275938 signaturepermissions-required
https://vuldb.com/?submit.394030 third-party-advisory
https://github.com/abcdefg-png/AHU-IoT-vulnerable… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda O6 Affected: 1.0.0.7(2054)
Create a notification for this product.
tenda o6_firmware Affected: 1.0.0.7\(2054\)
    cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
yhryhryhr_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "o6_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.0.7\\(2054\\)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8229",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-28T15:54:16.386339Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-28T15:54:55.065Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "O6",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.0.7(2054)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been declared as critical. This vulnerability affects the function frommacFilterModify of the file /goform/operateMacFilter. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda O6 1.0.0.7(2054) wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion frommacFilterModify der Datei /goform/operateMacFilter. Durch die Manipulation des Arguments mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-28T00:31:05.407Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-275938 | Tenda O6 operateMacFilter frommacFilterModify stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.275938"
        },
        {
          "name": "VDB-275938 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.275938"
        },
        {
          "name": "Submit #394030 | Tenda O6 V3.0 V1.0.0.7(2054) Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.394030"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/AHU-IoT-vulnerable/blob/main/Tenda/web-bridge/O6V3.0/fromMacFilterModify.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-27T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-27T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-27T15:17:37.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda O6 operateMacFilter frommacFilterModify stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-8229",
    "datePublished": "2024-08-28T00:31:05.407Z",
    "dateReserved": "2024-08-27T13:12:15.785Z",
    "dateUpdated": "2024-08-28T15:54:55.065Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-8230 (GCVE-0-2024-8230)

Vulnerability from cvelistv5 – Published: 2024-08-28 01:00 – Updated: 2024-08-28 15:53
VLAI
Title
Tenda O6 setMacFilterList fromSafeSetMacFilter stack-based overflow
Summary
A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument remark/type/time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.275939 vdb-entrytechnical-description
https://vuldb.com/?ctiid.275939 signaturepermissions-required
https://vuldb.com/?submit.394031 third-party-advisory
https://github.com/abcdefg-png/AHU-IoT-vulnerable… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda O6 Affected: 1.0.0.7(2054)
Create a notification for this product.
tenda o6_firmware Affected: 1.0.0.7\(2054\)
    cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
yhryhryhr_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "o6_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.0.7\\(2054\\)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8230",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-28T15:52:54.234842Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-28T15:53:48.670Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "O6",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.0.7(2054)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument remark/type/time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda O6 1.0.0.7(2054) ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion fromSafeSetMacFilter der Datei /goform/setMacFilterList. Durch Manipulation des Arguments remark/type/time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-28T01:00:07.395Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-275939 | Tenda O6 setMacFilterList fromSafeSetMacFilter stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.275939"
        },
        {
          "name": "VDB-275939 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.275939"
        },
        {
          "name": "Submit #394031 | Tenda O6 V3.0 V1.0.0.7(2054) Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.394031"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/AHU-IoT-vulnerable/blob/main/Tenda/web-bridge/O6V3.0/fromSafeSetMacFilter.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-27T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-27T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-27T15:17:38.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda O6 setMacFilterList fromSafeSetMacFilter stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-8230",
    "datePublished": "2024-08-28T01:00:07.395Z",
    "dateReserved": "2024-08-27T13:12:18.685Z",
    "dateUpdated": "2024-08-28T15:53:48.670Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-8231 (GCVE-0-2024-8231)

Vulnerability from cvelistv5 – Published: 2024-08-28 01:00 – Updated: 2024-08-28 15:52
VLAI
Title
Tenda O6 setPortForward fromVirtualSet stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda O6 1.0.0.7(2054). Affected is the function fromVirtualSet of the file /goform/setPortForward. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.275940 vdb-entrytechnical-description
https://vuldb.com/?ctiid.275940 signaturepermissions-required
https://vuldb.com/?submit.394032 third-party-advisory
https://github.com/abcdefg-png/AHU-IoT-vulnerable… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda O6 Affected: 1.0.0.7(2054)
Create a notification for this product.
tenda o6_firmware Affected: 1.0.0.7\(2054\)
    cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
yhryhryhr_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:o6_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "o6_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.0.7\\(2054\\)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8231",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-28T15:48:19.341160Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-28T15:52:09.155Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "O6",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.0.7(2054)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda O6 1.0.0.7(2054). Affected is the function fromVirtualSet of the file /goform/setPortForward. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda O6 1.0.0.7(2054) entdeckt. Es betrifft die Funktion fromVirtualSet der Datei /goform/setPortForward. Mittels dem Manipulieren des Arguments ip/localPort/publicPort/app mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-28T01:00:09.903Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-275940 | Tenda O6 setPortForward fromVirtualSet stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.275940"
        },
        {
          "name": "VDB-275940 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.275940"
        },
        {
          "name": "Submit #394032 | Tenda O6 V3.0 V1.0.0.7(2054) Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.394032"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/AHU-IoT-vulnerable/blob/main/Tenda/web-bridge/O6V3.0/fromVirtualSet.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-27T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-27T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-27T15:17:39.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda O6 setPortForward fromVirtualSet stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-8231",
    "datePublished": "2024-08-28T01:00:09.903Z",
    "dateReserved": "2024-08-27T13:12:21.701Z",
    "dateUpdated": "2024-08-28T15:52:09.155Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-8408 (GCVE-0-2024-8408)

Vulnerability from cvelistv5 – Published: 2024-09-04 14:00 – Updated: 2024-09-04 14:13
VLAI
Title
Linksys WRT54G POST Parameter apply.cgi validate_services_port stack-based overflow
Summary
A vulnerability was found in Linksys WRT54G 4.21.5. It has been rated as critical. Affected by this issue is the function validate_services_port of the file /apply.cgi of the component POST Parameter Handler. The manipulation of the argument services_array leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.276488 vdb-entrytechnical-description
https://vuldb.com/?ctiid.276488 signaturepermissions-required
https://vuldb.com/?submit.398567 third-party-advisory
https://github.com/BuaaIOTTeam/Iot_Linksys/blob/m… exploit
https://www.linksys.com/ product
Impacted products
Vendor Product Version
Linksys WRT54G Affected: 4.21.5
Create a notification for this product.
linksys wrt54g Affected: 4.21.5
    cpe:2.3:h:linksys:wrt54g:4.21.5:*:*:*:*:*:*:*
Create a notification for this product.
Credits
Buaa1otTeam (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:linksys:wrt54g:4.21.5:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "wrt54g",
            "vendor": "linksys",
            "versions": [
              {
                "status": "affected",
                "version": "4.21.5"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8408",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-04T14:12:34.563714Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-04T14:13:56.158Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "POST Parameter Handler"
          ],
          "product": "WRT54G",
          "vendor": "Linksys",
          "versions": [
            {
              "status": "affected",
              "version": "4.21.5"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Buaa1otTeam (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Linksys WRT54G 4.21.5. It has been rated as critical. Affected by this issue is the function validate_services_port of the file /apply.cgi of the component POST Parameter Handler. The manipulation of the argument services_array leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Linksys WRT54G 4.21.5 ausgemacht. Betroffen davon ist die Funktion validate_services_port der Datei /apply.cgi der Komponente POST Parameter Handler. Durch die Manipulation des Arguments services_array mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-04T14:00:06.823Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-276488 | Linksys WRT54G POST Parameter apply.cgi validate_services_port stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.276488"
        },
        {
          "name": "VDB-276488 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.276488"
        },
        {
          "name": "Submit #398567 | Linksys WRT54G  v4.21.5 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.398567"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/BuaaIOTTeam/Iot_Linksys/blob/main/Linksys_WRT54G_validate_services_port.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.linksys.com/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-09-04T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-09-04T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-09-04T09:06:15.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Linksys WRT54G POST Parameter apply.cgi validate_services_port stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-8408",
    "datePublished": "2024-09-04T14:00:06.823Z",
    "dateReserved": "2024-09-04T07:01:04.112Z",
    "dateUpdated": "2024-09-04T14:13:56.158Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-9043 (GCVE-0-2024-9043)

Vulnerability from cvelistv5 – Published: 2024-09-20 10:14 – Updated: 2024-09-20 13:53
VLAI
Title
Cellopoint Secure Email Gateway - Buffer Overflow
Summary
Secure Email Gateway from Cellopoint has Buffer Overflow Vulnerability in authentication process. Remote unauthenticated attackers can send crafted packets to crash the process, thereby bypassing authentication and obtaining system administrator privileges.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Cellopoint Secure Email Gateway Affected: 4.2.1 , ≤ 4.5.0 (custom)
Create a notification for this product.
cellopoint secure_email_gateway Affected: 4.2.1 , ≤ 4.5.0 (custom)
    cpe:2.3:a:cellopoint:secure_email_gateway:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-09-20 10:11
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:cellopoint:secure_email_gateway:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "secure_email_gateway",
            "vendor": "cellopoint",
            "versions": [
              {
                "lessThanOrEqual": "4.5.0",
                "status": "affected",
                "version": "4.2.1",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-9043",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-20T13:50:33.676008Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-20T13:53:46.836Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Secure Email Gateway",
          "vendor": "Cellopoint",
          "versions": [
            {
              "lessThanOrEqual": "4.5.0",
              "status": "affected",
              "version": "4.2.1",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2024-09-20T10:11:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Secure Email Gateway from Cellopoint has Buffer Overflow Vulnerability in authentication process. Remote unauthenticated attackers can send crafted packets to crash the process, thereby bypassing authentication and obtaining system administrator privileges."
            }
          ],
          "value": "Secure Email Gateway from Cellopoint has Buffer Overflow Vulnerability in authentication process. Remote unauthenticated attackers can send crafted packets to crash the process, thereby bypassing authentication and obtaining system administrator privileges."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-20T10:14:02.578Z",
        "orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
        "shortName": "twcert"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.twcert.org.tw/tw/cp-132-8102-b94a9-1.html"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.twcert.org.tw/en/cp-139-8103-b0568-2.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Install patch\u0026nbsp;Build_20240712 or later."
            }
          ],
          "value": "Install patch\u00a0Build_20240712 or later."
        }
      ],
      "source": {
        "advisory": "TVN-202409027",
        "discovery": "INTERNAL"
      },
      "title": "Cellopoint Secure Email Gateway - Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
    "assignerShortName": "twcert",
    "cveId": "CVE-2024-9043",
    "datePublished": "2024-09-20T10:14:02.578Z",
    "dateReserved": "2024-09-20T10:05:05.810Z",
    "dateUpdated": "2024-09-20T13:53:46.836Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-9261 (GCVE-0-2024-9261)

Vulnerability from cvelistv5 – Published: 2024-11-22 21:11 – Updated: 2024-11-25 16:05
VLAI
Title
IrfanView SID File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability
Summary
IrfanView SID File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of IrfanView. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of SID files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-23283.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
zdi
References
Impacted products
Vendor Product Version
IrfanView IrfanView Affected: 4.66 64bit
Create a notification for this product.
irfanview irfanview Affected: 4.66 , < 4.67 (custom)
    cpe:2.3:a:irfanview:irfanview:-:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-10-11 22:06
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:irfanview:irfanview:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "irfanview",
            "vendor": "irfanview",
            "versions": [
              {
                "lessThan": "4.67",
                "status": "affected",
                "version": "4.66",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-9261",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-25T16:05:45.844952Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-25T16:05:51.570Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "IrfanView",
          "vendor": "IrfanView",
          "versions": [
            {
              "status": "affected",
              "version": "4.66 64bit"
            }
          ]
        }
      ],
      "dateAssigned": "2024-09-26T19:41:58.007Z",
      "datePublic": "2024-10-11T22:06:30.262Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "IrfanView SID File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of IrfanView. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of SID files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-23283."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-22T21:11:25.466Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1374",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1374/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "Anonymous"
      },
      "title": "IrfanView SID File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-9261",
    "datePublished": "2024-11-22T21:11:25.466Z",
    "dateReserved": "2024-09-26T19:41:57.983Z",
    "dateUpdated": "2024-11-25T16:05:51.570Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-9284 (GCVE-0-2024-9284)

Vulnerability from cvelistv5 – Published: 2024-09-27 16:31 – Updated: 2024-09-27 18:38
VLAI
Title
TP-LINK TL-WR841ND popupSiteSurveyRpm.htm stack-based overflow
Summary
A vulnerability was found in TP-LINK TL-WR841ND up to 20240920. It has been rated as critical. Affected by this issue is some unknown functionality of the file /userRpm/popupSiteSurveyRpm.htm. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.278684 vdb-entrytechnical-description
https://vuldb.com/?ctiid.278684 signaturepermissions-required
https://vuldb.com/?submit.411526 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
https://www.tp-link.com/ product
Impacted products
Vendor Product Version
TP-LINK TL-WR841ND Affected: 20240920
Create a notification for this product.
tp-link tl-wr841nd_\(11.0\)_firmware Affected: 0 , < 20240920 (custom)
    cpe:2.3:o:tp-link:tl-wr841nd_\(11.0\)_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tp-link:tl-wr841nd_\\(11.0\\)_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "tl-wr841nd_\\(11.0\\)_firmware",
            "vendor": "tp-link",
            "versions": [
              {
                "lessThan": "20240920",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-9284",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-27T18:29:56.798651Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-27T18:38:13.225Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TL-WR841ND",
          "vendor": "TP-LINK",
          "versions": [
            {
              "status": "affected",
              "version": "20240920"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in TP-LINK TL-WR841ND up to 20240920. It has been rated as critical. Affected by this issue is some unknown functionality of the file /userRpm/popupSiteSurveyRpm.htm. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in TP-LINK TL-WR841ND bis 20240920 ausgemacht. Hierbei geht es um eine nicht exakt ausgemachte Funktion der Datei /userRpm/popupSiteSurveyRpm.htm. Durch Beeinflussen des Arguments ssid mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.8,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-27T16:31:04.406Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-278684 | TP-LINK TL-WR841ND popupSiteSurveyRpm.htm stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.278684"
        },
        {
          "name": "VDB-278684 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.278684"
        },
        {
          "name": "Submit #411526 | TP-LINK TL-WR841ND V11 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.411526"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TP-LINK/WR-841ND/popupSiteSurveyRpm.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tp-link.com/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-09-27T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-09-27T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-09-27T13:38:32.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TP-LINK TL-WR841ND popupSiteSurveyRpm.htm stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-9284",
    "datePublished": "2024-09-27T16:31:04.406Z",
    "dateReserved": "2024-09-27T11:32:46.720Z",
    "dateUpdated": "2024-09-27T18:38:13.225Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-9726 (GCVE-0-2024-9726)

Vulnerability from cvelistv5 – Published: 2024-11-22 20:51 – Updated: 2024-12-04 21:39
VLAI
Title
Trimble SketchUp Viewer SKP File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability
Summary
Trimble SketchUp Viewer SKP File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Trimble SketchUp Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of SKP files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24110.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
zdi
References
Impacted products
Vendor Product Version
Trimble SketchUp Viewer Affected: 22.0.316.0
Create a notification for this product.
trimble sketchup_viewer Affected: 22.0.316.0
    cpe:2.3:a:trimble:sketchup_viewer:22.0.316.0:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-11-12 22:21
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:trimble:sketchup_viewer:22.0.316.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sketchup_viewer",
            "vendor": "trimble",
            "versions": [
              {
                "status": "affected",
                "version": "22.0.316.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-9726",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-26T15:15:37.006231Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-04T21:39:12.190Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SketchUp Viewer",
          "vendor": "Trimble",
          "versions": [
            {
              "status": "affected",
              "version": "22.0.316.0"
            }
          ]
        }
      ],
      "dateAssigned": "2024-10-09T19:38:55.440Z",
      "datePublic": "2024-11-12T22:21:28.840Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Trimble SketchUp Viewer SKP File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Trimble SketchUp Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of SKP files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24110."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-22T20:51:57.381Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1475",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1475/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "Mat Powell of Trend Micro Zero Day Initiative"
      },
      "title": "Trimble SketchUp Viewer SKP File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-9726",
    "datePublished": "2024-11-22T20:51:57.381Z",
    "dateReserved": "2024-10-09T19:38:55.419Z",
    "dateUpdated": "2024-12-04T21:39:12.190Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-9745 (GCVE-0-2024-9745)

Vulnerability from cvelistv5 – Published: 2024-11-22 21:01 – Updated: 2024-11-25 16:05
VLAI
Title
Tungsten Automation Power PDF TIF File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability
Summary
Tungsten Automation Power PDF TIF File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Tungsten Automation Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of TIF files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24461.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
zdi
References
Impacted products
Vendor Product Version
Tungsten Automation Power PDF Affected: 5.0.0.10.0.23307
Create a notification for this product.
tungstenautomation power_pdf Affected: 5.0.0.10.0.23307 , < 5.1 (custom)
    cpe:2.3:a:tungstenautomation:power_pdf:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-10-11 21:57
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:tungstenautomation:power_pdf:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "power_pdf",
            "vendor": "tungstenautomation",
            "versions": [
              {
                "lessThan": "5.1",
                "status": "affected",
                "version": "5.0.0.10.0.23307",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-9745",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-25T15:58:27.753956Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-25T16:05:42.202Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Power PDF",
          "vendor": "Tungsten Automation",
          "versions": [
            {
              "status": "affected",
              "version": "5.0.0.10.0.23307"
            }
          ]
        }
      ],
      "dateAssigned": "2024-10-09T19:43:15.930Z",
      "datePublic": "2024-10-11T21:57:44.565Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Tungsten Automation Power PDF TIF File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Tungsten Automation Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of TIF files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24461."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-22T21:01:21.447Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1347",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1347/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "Mat Powell of Trend Micro Zero Day Initiative"
      },
      "title": "Tungsten Automation Power PDF TIF File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-9745",
    "datePublished": "2024-11-22T21:01:21.447Z",
    "dateReserved": "2024-10-09T19:43:15.899Z",
    "dateUpdated": "2024-11-25T16:05:42.202Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-0282 (GCVE-0-2025-0282)

Vulnerability from cvelistv5 – Published: 2025-01-08 22:15 – Updated: 2025-10-21 22:55
VLAI
Summary
A stack-based buffer overflow in Ivanti Connect Secure before version 22.7R2.5, Ivanti Policy Secure before version 22.7R1.2, and Ivanti Neurons for ZTA gateways before version 22.7R2.3 allows a remote unauthenticated attacker to achieve remote code execution.
SSVC
Exploitation: active Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
Ivanti Connect Secure Affected: 22.7R2 , ≤ 22.7R2.4 (custom)
Unaffected: 22.7R2.5 (custom)
Create a notification for this product.
Ivanti Policy Secure Affected: 22.7R1 , ≤ 22.7R1.2 (custom)
Create a notification for this product.
Ivanti Neurons for ZTA gateways Affected: 22.7R2 , ≤ 22.7R2.3 (custom)
Unaffected: 22.7R2.5 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "dateAdded": "2025-01-08",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2025-0282"
              },
              "type": "kev"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-0282",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-28T17:00:49.115686Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-21T22:55:33.039Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "third-party-advisory"
            ],
            "url": "https://labs.watchtowr.com/exploitation-walkthrough-and-techniques-ivanti-connect-secure-rce-cve-2025-0282/"
          },
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?search_api_fulltext=CVE-2025-0282"
          },
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/sfewer-r7/CVE-2025-0282"
          },
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2025-0282"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2025-01-08T00:00:00.000Z",
            "value": "CVE-2025-0282 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-01-09T21:45:22.375Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://www.cisa.gov/cisa-mitigation-instructions-cve-2025-0282"
          },
          {
            "url": "https://cloud.google.com/blog/topics/threat-intelligence/ivanti-connect-secure-vpn-zero-day"
          }
        ],
        "title": "CVE Program Container",
        "x_generator": {
          "engine": "ADPogram 0.0.1"
        }
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Connect Secure",
          "vendor": "Ivanti",
          "versions": [
            {
              "lessThanOrEqual": "22.7R2.4",
              "status": "affected",
              "version": "22.7R2",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "22.7R2.5",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Policy Secure",
          "vendor": "Ivanti",
          "versions": [
            {
              "lessThanOrEqual": "22.7R1.2",
              "status": "affected",
              "version": "22.7R1",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Neurons for ZTA gateways",
          "vendor": "Ivanti",
          "versions": [
            {
              "lessThanOrEqual": "22.7R2.3",
              "status": "affected",
              "version": "22.7R2",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "22.7R2.5",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA stack-based buffer overflow in Ivanti Connect Secure before version 22.7R2.5, Ivanti Policy Secure before version 22.7R1.2, and Ivanti Neurons for ZTA gateways before version 22.7R2.3 allows a remote unauthenticated attacker to achieve remote code execution.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "A stack-based buffer overflow in Ivanti Connect Secure before version 22.7R2.5, Ivanti Policy Secure before version 22.7R1.2, and Ivanti Neurons for ZTA gateways before version 22.7R2.3 allows a remote unauthenticated attacker to achieve remote code execution."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-08T22:15:09.386Z",
        "orgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "shortName": "ivanti"
      },
      "references": [
        {
          "url": "https://forums.ivanti.com/s/article/Security-Advisory-Ivanti-Connect-Secure-Policy-Secure-ZTA-Gateways-CVE-2025-0282-CVE-2025-0283"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
    "assignerShortName": "ivanti",
    "cveId": "CVE-2025-0282",
    "datePublished": "2025-01-08T22:15:09.386Z",
    "dateReserved": "2025-01-06T16:53:11.204Z",
    "dateUpdated": "2025-10-21T22:55:33.039Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation ID: MIT-10

Phases: Operation, Build and Compilation

Strategy: Environment Hardening

Description:

  • Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
  • D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation

Phase: Architecture and Design

Description:

  • Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation

Phase: Implementation

Description:

  • Implement and perform bounds checking on input.
Mitigation

Phase: Implementation

Description:

  • Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.
Mitigation ID: MIT-11

Phases: Operation, Build and Compilation

Strategy: Environment Hardening

Description:

  • Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
  • Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
  • For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].

No CAPEC attack patterns related to this CWE.

Back to CWE stats page