CWE-1263

Improper Physical Access Control

The product is designed with access restricted to certain information, but it does not sufficiently protect against an unauthorized actor with physical access to these areas.

CVE-2022-3728 (GCVE-0-2022-3728)

Vulnerability from cvelistv5 – Published: 2023-10-09 20:48 – Updated: 2024-09-19 13:50
VLAI?
Summary
A vulnerability was reported in ThinkPad T14s Gen 3 and X13 Gen3 that could cause the BIOS tamper detection mechanism to not trigger under specific circumstances which could allow unauthorized access.
CWE
  • CWE-1263 - Improper Physical Access Control
Assigner
Impacted products
Vendor Product Version
Lenovo ThinkPad T14s Gen 3 BIOS Affected: , < 1.30 (R22ET60W) (custom)
Create a notification for this product.
    Lenovo ThinkPad X13 Gen3 BIOS Affected: , < 1.30 (R22ET60W) (semver)
Create a notification for this product.
Credits
Lenovo thanks Zoltan Harmath for reporting this vulnerability.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:20:57.786Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.lenovo.com/us/en/product_security/LEN-106014"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-3728",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-19T13:15:00.566836Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-19T13:50:29.916Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "ThinkPad T14s Gen 3 BIOS",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "1.30 (R22ET60W)",
              "status": "affected",
              "version": " ",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "ThinkPad X13 Gen3 BIOS",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "1.30 (R22ET60W)",
              "status": "affected",
              "version": " ",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Lenovo thanks Zoltan Harmath for reporting this vulnerability."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA vulnerability was reported in ThinkPad T14s Gen 3 and X13 Gen3 that could cause the BIOS tamper detection mechanism to not trigger under specific circumstances which could allow unauthorized access. \u003c/span\u003e\n\n"
            }
          ],
          "value": "\nA vulnerability was reported in ThinkPad T14s Gen 3 and X13 Gen3 that could cause the BIOS tamper detection mechanism to not trigger under specific circumstances which could allow unauthorized access. \n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1263",
              "description": "CWE-1263: Improper Physical Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-09T20:48:31.533Z",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "url": "https://support.lenovo.com/us/en/product_security/LEN-106014"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpdate system firmware to the version\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e1.30 (R22ET60W)\u003c/span\u003e\nor newer.\u003c/span\u003e\u0026nbsp;"
            }
          ],
          "value": "\nUpdate system firmware to the version\u00a01.30 (R22ET60W)\nor newer.\u00a0"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2022-3728",
    "datePublished": "2023-10-09T20:48:31.533Z",
    "dateReserved": "2022-10-27T19:37:24.477Z",
    "dateUpdated": "2024-09-19T13:50:29.916Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-48182 (GCVE-0-2022-48182)

Vulnerability from cvelistv5 – Published: 2023-10-09 20:55 – Updated: 2024-09-19 13:18
VLAI?
Summary
A vulnerability was reported in ThinkPad T14s Gen 3 and X13 Gen3 that could cause the BIOS tamper detection mechanism to not trigger under specific circumstances which could allow unauthorized access.
CWE
  • CWE-1263 - Improper Physical Access Control
Assigner
Impacted products
Credits
Lenovo thanks Zoltan Harmath for reporting this vulnerability.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T15:02:36.729Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.lenovo.com/us/en/product_security/LEN-106014"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-48182",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-19T13:09:57.719833Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-19T13:18:03.342Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "ThinkPad T14s X13 Gen3 BIOS - Windows",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "1.30 (R22ET60W)",
              "status": "affected",
              "version": " ",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "ThinkPad X13 Gen3 BIOS - Windows",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "1.30 (R22ET60W)",
              "status": "affected",
              "version": " ",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "ThinkPad T14s Gen 3 BIOS - Linux",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "1.35 (N3CET54W) ",
              "status": "affected",
              "version": " ",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "ThinkPad X13 Gen3 BIOS - Linux",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "1.35 (N3CET54W) ",
              "status": "affected",
              "version": " ",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Lenovo thanks Zoltan Harmath for reporting this vulnerability."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA vulnerability was reported in ThinkPad T14s Gen 3 and X13 Gen3 that could cause the BIOS tamper detection mechanism to not trigger under specific circumstances which could allow unauthorized access. \u003c/span\u003e\n\n"
            }
          ],
          "value": "\nA vulnerability was reported in ThinkPad T14s Gen 3 and X13 Gen3 that could cause the BIOS tamper detection mechanism to not trigger under specific circumstances which could allow unauthorized access. \n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1263",
              "description": "CWE-1263: Improper Physical Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-09T20:55:55.993Z",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "url": "https://support.lenovo.com/us/en/product_security/LEN-106014"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpdate system firmware to the version\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e1.30 (R22ET60W)\u003c/span\u003e\nor newer.\u003c/span\u003e\u0026nbsp;"
            }
          ],
          "value": "\nUpdate system firmware to the version\u00a01.30 (R22ET60W)\nor newer.\u00a0"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2022-48182",
    "datePublished": "2023-10-09T20:55:55.993Z",
    "dateReserved": "2022-12-29T17:29:25.495Z",
    "dateUpdated": "2024-09-19T13:18:03.342Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-48183 (GCVE-0-2022-48183)

Vulnerability from cvelistv5 – Published: 2023-10-09 20:56 – Updated: 2024-09-19 13:17
VLAI?
Summary
A vulnerability was reported in ThinkPad T14s Gen 3 and X13 Gen3 that could cause the BIOS tamper detection mechanism to not trigger under specific circumstances which could allow unauthorized access.
CWE
  • CWE-1263 - Improper Physical Access Control
Assigner
Impacted products
Credits
Lenovo thanks Zoltan Harmath for reporting this vulnerability.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T15:02:36.783Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.lenovo.com/us/en/product_security/LEN-106014"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-48183",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-19T13:09:49.494974Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-19T13:17:42.466Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "ThinkPad T14s X13 Gen3 BIOS - Windows",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "1.30 (R22ET60W)",
              "status": "affected",
              "version": " ",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "ThinkPad X13 Gen3 BIOS - Windows",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "1.30 (R22ET60W)",
              "status": "affected",
              "version": " ",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "ThinkPad T14s Gen 3 BIOS - Linux",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "1.35 (N3CET54W) ",
              "status": "affected",
              "version": " ",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "ThinkPad X13 Gen3 BIOS - Linux",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "1.35 (N3CET54W) ",
              "status": "affected",
              "version": " ",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Lenovo thanks Zoltan Harmath for reporting this vulnerability."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA vulnerability was reported in ThinkPad T14s Gen 3 and X13 Gen3 that could cause the BIOS tamper detection mechanism to not trigger under specific circumstances which could allow unauthorized access. \u003c/span\u003e\n\n"
            }
          ],
          "value": "\nA vulnerability was reported in ThinkPad T14s Gen 3 and X13 Gen3 that could cause the BIOS tamper detection mechanism to not trigger under specific circumstances which could allow unauthorized access. \n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1263",
              "description": "CWE-1263: Improper Physical Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-09T20:56:44.367Z",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "url": "https://support.lenovo.com/us/en/product_security/LEN-106014"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpdate system firmware to the version\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e1.30 (R22ET60W)\u003c/span\u003e\nor newer.\u003c/span\u003e\u0026nbsp;"
            }
          ],
          "value": "\nUpdate system firmware to the version\u00a01.30 (R22ET60W)\nor newer.\u00a0"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2022-48183",
    "datePublished": "2023-10-09T20:56:44.367Z",
    "dateReserved": "2022-12-29T17:29:25.495Z",
    "dateUpdated": "2024-09-19T13:17:42.466Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-39512 (GCVE-0-2024-39512)

Vulnerability from cvelistv5 – Published: 2024-07-10 23:02 – Updated: 2024-08-02 04:26
VLAI?
Summary
An Improper Physical Access Control vulnerability in the console port control of Juniper Networks Junos OS Evolved allows an attacker with physical access to the device to get access to a user account. When the console cable is disconnected, the logged in user is not logged out. This allows a malicious attacker with physical access to the console to resume a previous session and possibly gain administrative privileges. This issue affects Junos OS Evolved: * from 23.2R2-EVO before 23.2R2-S1-EVO,  * from 23.4R1-EVO before 23.4R2-EVO.
CWE
  • CWE-1263 - Improper Physical Access Control
Assigner
References
Impacted products
Vendor Product Version
Juniper Networks Junos OS Evolved Affected: 23.2R2-EVO , < 23.2R2-S1-EVO (semver)
Affected: 23.4R1-EVO , < 23.4R2-EVO (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:juniper:junos_evolved:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "junos_evolved",
            "vendor": "juniper",
            "versions": [
              {
                "lessThan": "23.2R2-S1-EVO",
                "status": "affected",
                "version": "23.2R2-EVO",
                "versionType": "semver"
              },
              {
                "lessThan": "23.4R2-EVO",
                "status": "affected",
                "version": "23.4R1-EVO",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-39512",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-12T15:12:54.866035Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-12T16:25:36.401Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T04:26:15.874Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://supportportal.juniper.net/JSA82977"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Junos OS Evolved",
          "vendor": "Juniper Networks",
          "versions": [
            {
              "lessThan": "23.2R2-S1-EVO",
              "status": "affected",
              "version": "23.2R2-EVO",
              "versionType": "semver"
            },
            {
              "lessThan": "23.4R2-EVO",
              "status": "affected",
              "version": "23.4R1-EVO",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-07-10T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Improper Physical Access Control vulnerability in the console port control of Juniper Networks Junos OS Evolved allows an attacker with physical access to the device to get access to a user account.\u003cbr\u003e\u003cbr\u003eWhen the console cable is disconnected, the logged in user is not logged out.\u0026nbsp;This allows a malicious attacker with physical access to the console to resume a previous session and possibly gain administrative privileges.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eThis issue affects Junos OS Evolved: \u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003efrom 23.2R2-EVO before 23.2R2-S1-EVO,\u0026nbsp;\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003efrom 23.4R1-EVO before 23.4R2-EVO.\u003c/span\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/span\u003e"
            }
          ],
          "value": "An Improper Physical Access Control vulnerability in the console port control of Juniper Networks Junos OS Evolved allows an attacker with physical access to the device to get access to a user account.\n\nWhen the console cable is disconnected, the logged in user is not logged out.\u00a0This allows a malicious attacker with physical access to the console to resume a previous session and possibly gain administrative privileges.\n\nThis issue affects Junos OS Evolved: \n  *  from 23.2R2-EVO before 23.2R2-S1-EVO,\u00a0\n  *  from 23.4R1-EVO before 23.4R2-EVO."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
            }
          ],
          "value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "PHYSICAL",
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1263",
              "description": "CWE-1263 Improper Physical Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-10T23:02:05.458Z",
        "orgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
        "shortName": "juniper"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://supportportal.juniper.net/JSA82977"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The following software releases have been updated to resolve this specific issue: 23.2R2-S1-EVO, 23.4R2-EVO, 24.2R1-EVO, and all subsequent releases."
            }
          ],
          "value": "The following software releases have been updated to resolve this specific issue: 23.2R2-S1-EVO, 23.4R2-EVO, 24.2R1-EVO, and all subsequent releases."
        }
      ],
      "source": {
        "advisory": "JSA82977",
        "defect": [
          "1802653"
        ],
        "discovery": "INTERNAL"
      },
      "title": "Junos OS Evolved: User is not logged out when the console cable is disconnected",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "There are no known workarounds for this issue."
            }
          ],
          "value": "There are no known workarounds for this issue."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
    "assignerShortName": "juniper",
    "cveId": "CVE-2024-39512",
    "datePublished": "2024-07-10T23:02:05.458Z",
    "dateReserved": "2024-06-25T15:12:53.237Z",
    "dateUpdated": "2024-08-02T04:26:15.874Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-48973 (GCVE-0-2024-48973)

Vulnerability from cvelistv5 – Published: 2024-11-14 21:24 – Updated: 2024-11-18 15:33
VLAI?
Summary
The debug port on the ventilator's serial interface is enabled by default. This could allow an attacker to send and receive messages over the debug port (which are unencrypted; see 3.2.1) that result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance.
CWE
  • CWE-1263 - Improper Physical Access Control
Assigner
Impacted products
Vendor Product Version
Baxter Life2000 Ventilation System Affected: 06.08.00.00 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:baxter:life2000_ventilator_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "life2000_ventilator_firmware",
            "vendor": "baxter",
            "versions": [
              {
                "lessThanOrEqual": "06.08.00.00",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-48973",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-18T15:33:07.996857Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-18T15:33:44.924Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Life2000 Ventilation System",
          "vendor": "Baxter",
          "versions": [
            {
              "status": "affected",
              "version": "06.08.00.00 and prior"
            }
          ]
        }
      ],
      "datePublic": "2024-11-14T21:21:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The debug port on the ventilator\u0027s serial interface is enabled by default. This could allow an attacker to send and receive messages over the debug port (which are unencrypted; see 3.2.1) that result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance.\u003cbr\u003e"
            }
          ],
          "value": "The debug port on the ventilator\u0027s serial interface is enabled by default. This could allow an attacker to send and receive messages over the debug port (which are unencrypted; see 3.2.1) that result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-117",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-117 Interception"
            }
          ]
        },
        {
          "capecId": "CAPEC-441",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-441 Malicious Logic Insertion"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1263",
              "description": "CWE-1263 Improper Physical Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-14T21:49:44.756Z",
        "orgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
        "shortName": "Baxter"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-319-01"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Debug port on Life2000 Ventilator serial interface is enabled by default",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
    "assignerShortName": "Baxter",
    "cveId": "CVE-2024-48973",
    "datePublished": "2024-11-14T21:24:14.099Z",
    "dateReserved": "2024-10-10T19:24:41.495Z",
    "dateUpdated": "2024-11-18T15:33:44.924Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-6785 (GCVE-0-2025-6785)

Vulnerability from cvelistv5 – Published: 2025-09-04 14:13 – Updated: 2025-09-11 10:54
VLAI?
Summary
Securing externally available CAN wires can easily allow physical access to the CAN bus, allowing possible injection of specially formed CAN messages to control remote start functions of the vehicle.  Testing completed on Tesla Model 3 vehicles with software version v11.1 (2023.20.9 ee6de92ddac5). This issue affects Model 3: With software versions from 2023.Xx before 2023.44.
CWE
  • CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
  • CWE-1263 - Improper Physical Access Control
Assigner
References
Impacted products
Vendor Product Version
Tesla Model 3 Affected: 2023.xx , < 2023.44 (custom)
Create a notification for this product.
Credits
Netanel Saka (Plaxidityx)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-6785",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-04T14:23:41.236074Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-04T14:23:47.393Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Model 3",
          "vendor": "Tesla",
          "versions": [
            {
              "lessThan": "2023.44",
              "status": "affected",
              "version": "2023.xx",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Netanel Saka (Plaxidityx)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Securing externally available CAN wires can easily allow physical access to the CAN bus, allowing possible injection of specially formed CAN messages to control remote start functions of the vehicle.\u0026nbsp; Testing completed on\u0026nbsp;Tesla Model 3 vehicles with software version v11.1 (2023.20.9 ee6de92ddac5).\u0026nbsp;\u003cp\u003eThis issue affects Model 3: With software versions from 2023.Xx before 2023.44.\u003c/p\u003e"
            }
          ],
          "value": "Securing externally available CAN wires can easily allow physical access to the CAN bus, allowing possible injection of specially formed CAN messages to control remote start functions of the vehicle.\u00a0 Testing completed on\u00a0Tesla Model 3 vehicles with software version v11.1 (2023.20.9 ee6de92ddac5).\u00a0This issue affects Model 3: With software versions from 2023.Xx before 2023.44."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-401",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-401 Physically Hacking Hardware"
            }
          ]
        },
        {
          "capecId": "CAPEC-6",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-6 Argument Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "YES",
            "Recovery": "AUTOMATIC",
            "Safety": "NEGLIGIBLE",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "PHYSICAL",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "AMBER",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "DIFFUSE",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:H/SI:H/SA:H/S:N/AU:Y/R:A/V:D/RE:L/U:Amber",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "LOW"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-1263",
              "description": "CWE-1263 Improper Physical Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-11T10:54:40.950Z",
        "orgId": "c15abc07-96a9-4d11-a503-5d621bfe42ba",
        "shortName": "ASRG"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://asrg.io/security-advisories/cve-2025-6785/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Tesla Model 3 Physical CAN Bus Injection",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c15abc07-96a9-4d11-a503-5d621bfe42ba",
    "assignerShortName": "ASRG",
    "cveId": "CVE-2025-6785",
    "datePublished": "2025-09-04T14:13:22.348Z",
    "dateReserved": "2025-06-27T12:29:05.458Z",
    "dateUpdated": "2025-09-11T10:54:40.950Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-8762 (GCVE-0-2025-8762)

Vulnerability from cvelistv5 – Published: 2025-08-13 06:14 – Updated: 2025-08-13 13:30
VLAI?
Summary
A vulnerability was found in INSTAR 2K+ and 4K 3.11.1 Build 1124. This issue affects some unknown processing of the component UART Interface. The manipulation leads to improper physical access control. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used.
CWE
  • CWE-1263 - Improper Physical Access Control
  • CWE-284 - Improper Access Controls
Assigner
Impacted products
Vendor Product Version
INSTAR 2K+ Affected: 3.11.1 Build 1124
Create a notification for this product.
    INSTAR 4K Affected: 3.11.1 Build 1124
Create a notification for this product.
Credits
Michael Imfeld (modzero AG)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8762",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-13T13:30:16.418304Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-13T13:30:21.695Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "UART Interface"
          ],
          "product": "2K+",
          "vendor": "INSTAR",
          "versions": [
            {
              "status": "affected",
              "version": "3.11.1 Build 1124"
            }
          ]
        },
        {
          "modules": [
            "UART Interface"
          ],
          "product": "4K",
          "vendor": "INSTAR",
          "versions": [
            {
              "status": "affected",
              "version": "3.11.1 Build 1124"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Michael Imfeld (modzero AG)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in INSTAR 2K+ and 4K 3.11.1 Build 1124. This issue affects some unknown processing of the component UART Interface. The manipulation leads to improper physical access control. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Davon betroffen ist unbekannter Code der Komponente UART Interface. Durch das Manipulieren mit unbekannten Daten kann eine improper physical access control-Schwachstelle ausgenutzt werden. Ein Angriff setzt physischen Zugriff auf dem Zielobjekt voraus. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 7.2,
            "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1263",
              "description": "Improper Physical Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "Improper Access Controls",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-13T06:14:04.487Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-319865 | INSTAR 2K+/4K UART improper physical access control",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.319865"
        },
        {
          "name": "VDB-319865 | CTI Indicators (IOB, IOC)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.319865"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://modzero.com/static/MZ-25-03_modzero_INSTAR.pdf"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-08-13T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-08-13T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-08-13T08:18:26.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "INSTAR 2K+/4K UART improper physical access control"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-8762",
    "datePublished": "2025-08-13T06:14:04.487Z",
    "dateReserved": "2025-08-08T15:37:37.719Z",
    "dateUpdated": "2025-08-13T13:30:21.695Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}




Mitigation

Phase: Architecture and Design

Description:

  • Specific protection requirements depend strongly on contextual factors including the level of acceptable risk associated with compromise to the product's protection mechanism. Designers could incorporate anti-tampering measures that protect against or detect when the product has been tampered with.
Mitigation

Phase: Testing

Description:

  • The testing phase of the lifecycle should establish a method for determining whether the protection mechanism is sufficient to prevent unauthorized access.
Mitigation

Phase: Manufacturing

Description:

  • Ensure that all protection mechanisms are fully activated at the time of manufacturing and distribution.
CAPEC-401: Physically Hacking Hardware

An adversary exploits a weakness in access control to gain access to currently installed hardware and precedes to implement changes or secretly replace a hardware component which undermines the system's integrity for the purpose of carrying out an attack.

Back to CWE stats page