CWE-288
Authentication Bypass Using an Alternate Path or Channel
The product requires authentication, but the product has an alternate path or channel that does not require authentication.
CVE-2021-32986 (GCVE-0-2021-32986)
Vulnerability from cvelistv5 – Published: 2022-04-04 19:45 – Updated: 2025-04-16 16:31- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
| URL | Tags |
|---|---|
| https://www.cisa.gov/uscert/ics/advisories/icsa-2… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Automation Direct | CLICK PLC CPU Modules: C0-1x CPUs |
Affected:
unspecified , < 3.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:42:19.029Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-166-02"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-32986",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:56:15.348434Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:31:33.851Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "CLICK PLC CPU Modules: C0-1x CPUs",
"vendor": "Automation Direct",
"versions": [
{
"lessThan": "3.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Irfan Ahmed and Adeen Ayub of Virginia Commonwealth University and Hyunguk Yoo of the University of New Orleans reported these vulnerabilities to Automation Direct."
}
],
"descriptions": [
{
"lang": "en",
"value": "After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming connections are allowed without authorization. The PLC is only relocked by a power cycle, or when the programming software disconnects correctly."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-04T19:45:56.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-166-02"
}
],
"solutions": [
{
"lang": "en",
"value": "Automation Direct reports these vulnerabilities are all mitigated by Version 3.00 and recommends users update software and firmware to the latest version.\n\nAutomation Direct also recommends users follow its security guidelines."
}
],
"source": {
"advisory": "ICSA-21-166-02",
"discovery": "EXTERNAL"
},
"title": "Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-32986",
"STATE": "PUBLIC",
"TITLE": "Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CLICK PLC CPU Modules: C0-1x CPUs",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "3.00"
}
]
}
}
]
},
"vendor_name": "Automation Direct"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Irfan Ahmed and Adeen Ayub of Virginia Commonwealth University and Hyunguk Yoo of the University of New Orleans reported these vulnerabilities to Automation Direct."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming connections are allowed without authorization. The PLC is only relocked by a power cycle, or when the programming software disconnects correctly."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-288: Authentication Bypass Using an Alternate Path or Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-166-02",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-166-02"
}
]
},
"solution": [
{
"lang": "en",
"value": "Automation Direct reports these vulnerabilities are all mitigated by Version 3.00 and recommends users update software and firmware to the latest version.\n\nAutomation Direct also recommends users follow its security guidelines."
}
],
"source": {
"advisory": "ICSA-21-166-02",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-32986",
"datePublished": "2022-04-04T19:45:56.000Z",
"dateReserved": "2021-05-13T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:31:33.851Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-33017 (GCVE-0-2021-33017)
Vulnerability from cvelistv5 – Published: 2021-12-27 18:48 – Updated: 2024-09-16 20:16- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
| URL | Tags |
|---|---|
| https://www.cisa.gov/uscert/ics/advisories/icsma-… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | IntelliBridge EC 40 Hub |
Affected:
unspecified , ≤ C.00.04
(custom)
|
|
| Philips | IntelliBridge EC 80 Hub |
Affected:
unspecified , ≤ C.00.04
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:42:19.092Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "IntelliBridge EC 40 Hub",
"vendor": "Philips",
"versions": [
{
"lessThanOrEqual": "C.00.04",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "IntelliBridge EC 80 Hub",
"vendor": "Philips",
"versions": [
{
"lessThanOrEqual": "C.00.04",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Younes Dragoni, Andrea Palanca and Ivan Speziale of Nozomi Networks"
}
],
"datePublic": "2021-11-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The standard access path of the IntelliBridge EC 40 and 60 Hub (C.00.04 and prior) requires authentication, but the product has an alternate path or channel that does not require authentication."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288 Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-27T18:48:21.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-01"
}
],
"source": {
"advisory": "ICSMA-21-322-01",
"discovery": "UNKNOWN"
},
"title": "Philips IntelliBridge EC 40 and EC 80 Hub Authentication Bypass Using an Alternate Path or Channel",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-11-18T15:34:00.000Z",
"ID": "CVE-2021-33017",
"STATE": "PUBLIC",
"TITLE": "Philips IntelliBridge EC 40 and EC 80 Hub Authentication Bypass Using an Alternate Path or Channel"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IntelliBridge EC 40 Hub",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "C.00.04"
}
]
}
},
{
"product_name": "IntelliBridge EC 80 Hub",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "C.00.04"
}
]
}
}
]
},
"vendor_name": "Philips"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Younes Dragoni, Andrea Palanca and Ivan Speziale of Nozomi Networks"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The standard access path of the IntelliBridge EC 40 and 60 Hub (C.00.04 and prior) requires authentication, but the product has an alternate path or channel that does not require authentication."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-288 Authentication Bypass Using an Alternate Path or Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-01"
}
]
},
"solution": [
{
"lang": "en"
}
],
"source": {
"advisory": "ICSMA-21-322-01",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-33017",
"datePublished": "2021-12-27T18:48:21.413Z",
"dateReserved": "2021-05-13T00:00:00.000Z",
"dateUpdated": "2024-09-16T20:16:50.573Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-33700 (GCVE-0-2021-33700)
Vulnerability from cvelistv5 – Published: 2021-09-15 18:01 – Updated: 2024-08-03 23:58- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
| URL | Tags |
|---|---|
| https://wiki.scn.sap.com/wiki/pages/viewpage.acti… | x_refsource_MISC |
| https://launchpad.support.sap.com/#/notes/3073325 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| SAP SE | SAP Business One |
Affected:
< 10.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:58:22.388Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://wiki.scn.sap.com/wiki/pages/viewpage.action?pageId=582222806"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://launchpad.support.sap.com/#/notes/3073325"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SAP Business One",
"vendor": "SAP SE",
"versions": [
{
"status": "affected",
"version": "\u003c 10.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SAP Business One, version - 10.0, allows a local attacker with access to the victim\u0027s browser under certain circumstances, to login as the victim without knowing his/her password. The attacker could so obtain highly sensitive information which the attacker could use to take substantial control of the vulnerable application."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-15T18:01:51.000Z",
"orgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
"shortName": "sap"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://wiki.scn.sap.com/wiki/pages/viewpage.action?pageId=582222806"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://launchpad.support.sap.com/#/notes/3073325"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cna@sap.com",
"ID": "CVE-2021-33700",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SAP Business One",
"version": {
"version_data": [
{
"version_name": "\u003c",
"version_value": "10.0"
}
]
}
}
]
},
"vendor_name": "SAP SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "SAP Business One, version - 10.0, allows a local attacker with access to the victim\u0027s browser under certain circumstances, to login as the victim without knowing his/her password. The attacker could so obtain highly sensitive information which the attacker could use to take substantial control of the vulnerable application."
}
]
},
"impact": {
"cvss": {
"baseScore": "7.0",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-288: Authentication Bypass Using an Alternate Path or Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://wiki.scn.sap.com/wiki/pages/viewpage.action?pageId=582222806",
"refsource": "MISC",
"url": "https://wiki.scn.sap.com/wiki/pages/viewpage.action?pageId=582222806"
},
{
"name": "https://launchpad.support.sap.com/#/notes/3073325",
"refsource": "MISC",
"url": "https://launchpad.support.sap.com/#/notes/3073325"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
"assignerShortName": "sap",
"cveId": "CVE-2021-33700",
"datePublished": "2021-09-15T18:01:51.000Z",
"dateReserved": "2021-05-28T00:00:00.000Z",
"dateUpdated": "2024-08-03T23:58:22.388Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34977 (GCVE-0-2021-34977)
Vulnerability from cvelistv5 – Published: 2022-01-13 21:44 – Updated: 2024-08-04 00:26- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_refsource_MISC |
| https://kb.netgear.com/000064046/Security-Advisor… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:26:55.730Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1239/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000064046/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-and-DSL-Modem-Routers-PSV-2021-0134"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "R7000",
"vendor": "NETGEAR",
"versions": [
{
"status": "affected",
"version": "1.0.11.116_10.2.100"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Xinan Zhou (the University of California, Riverside and Fudan University)"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of NETGEAR R7000 1.0.11.116_10.2.100 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of SOAP requests. The issue results from the lack of proper authentication verification before performing a password reset. An attacker can leverage this vulnerability to reset the admin password. Was ZDI-CAN-13483."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-13T21:44:31.000Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1239/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000064046/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-and-DSL-Modem-Routers-PSV-2021-0134"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"ID": "CVE-2021-34977",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "R7000",
"version": {
"version_data": [
{
"version_value": "1.0.11.116_10.2.100"
}
]
}
}
]
},
"vendor_name": "NETGEAR"
}
]
}
},
"credit": "Xinan Zhou (the University of California, Riverside and Fudan University)",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of NETGEAR R7000 1.0.11.116_10.2.100 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of SOAP requests. The issue results from the lack of proper authentication verification before performing a password reset. An attacker can leverage this vulnerability to reset the admin password. Was ZDI-CAN-13483."
}
]
},
"impact": {
"cvss": {
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-288: Authentication Bypass Using an Alternate Path or Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-1239/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1239/"
},
{
"name": "https://kb.netgear.com/000064046/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-and-DSL-Modem-Routers-PSV-2021-0134",
"refsource": "MISC",
"url": "https://kb.netgear.com/000064046/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-and-DSL-Modem-Routers-PSV-2021-0134"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2021-34977",
"datePublished": "2022-01-13T21:44:31.000Z",
"dateReserved": "2021-06-17T00:00:00.000Z",
"dateUpdated": "2024-08-04T00:26:55.730Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-35530 (GCVE-0-2021-35530)
Vulnerability from cvelistv5 – Published: 2022-06-07 20:17 – Updated: 2024-09-16 23:26- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
| URL | Tags |
|---|---|
| https://search.abb.com/library/Download.aspx?Docu… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | TXpert Hub CoreTec 4 version |
Affected:
2.0.0
Affected: 2.0.1 Affected: 2.1.0 Affected: 2.1.1 Affected: 2.1.2 Affected: 2.1.3 Affected: 2.2.0 Affected: 2.2.1 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:40:46.698Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000080\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026utm_campaign=\u0026utm_content=2022.04_5763_Cybersecurity%20Advisory%20Update_May_03\u0026utm_medium=email\u0026utm_source=Eloqua"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "TXpert Hub CoreTec 4 version",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "2.0.0"
},
{
"status": "affected",
"version": "2.0.1"
},
{
"status": "affected",
"version": "2.1.0"
},
{
"status": "affected",
"version": "2.1.1"
},
{
"status": "affected",
"version": "2.1.2"
},
{
"status": "affected",
"version": "2.1.3"
},
{
"status": "affected",
"version": "2.2.0"
},
{
"status": "affected",
"version": "2.2.1"
}
]
}
],
"datePublic": "2022-05-10T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the application authentication and authorization mechanism in Hitachi Energy\u0027s TXpert Hub CoreTec 4, that depends on a token validation of the session identifier, allows an unauthorized modified message to be executed in the server enabling an unauthorized actor to change an existing user password, and further gain authorized access into the system via login mechanism. This issue affects: Hitachi Energy TXpert Hub CoreTec 4 version 2.0.0 2.1.0; 2.1.0; 2.1.1; 2.1.2; 2.1.3; 2.2.0; 2.2.1."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288 Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-07T20:17:07.000Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000080\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026utm_campaign=\u0026utm_content=2022.04_5763_Cybersecurity%20Advisory%20Update_May_03\u0026utm_medium=email\u0026utm_source=Eloqua"
}
],
"solutions": [
{
"lang": "en",
"value": "Update the system to TXpert Hub CoreTec 4 version 2.3.0 that fixes the issues."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "User authentication bypass in TXpert Hub CoreTec 4",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@hitachienergy.com",
"DATE_PUBLIC": "2022-05-10T10:00:00.000Z",
"ID": "CVE-2021-35530",
"STATE": "PUBLIC",
"TITLE": "User authentication bypass in TXpert Hub CoreTec 4"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "TXpert Hub CoreTec 4 version",
"version": {
"version_data": [
{
"version_affected": "=",
"version_name": "2.0.0",
"version_value": "2.0.0"
},
{
"version_affected": "=",
"version_name": "2.0.1",
"version_value": "2.0.1"
},
{
"version_affected": "=",
"version_name": "2.1.0",
"version_value": "2.1.0"
},
{
"version_affected": "=",
"version_name": "2.1.1",
"version_value": "2.1.1"
},
{
"version_affected": "=",
"version_name": "2.1.2",
"version_value": "2.1.2"
},
{
"version_affected": "=",
"version_name": "2.1.3",
"version_value": "2.1.3"
},
{
"version_affected": "=",
"version_name": "2.2.0",
"version_value": "2.2.0"
},
{
"version_affected": "=",
"version_name": "2.2.1",
"version_value": "2.2.1"
}
]
}
}
]
},
"vendor_name": "Hitachi Energy"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the application authentication and authorization mechanism in Hitachi Energy\u0027s TXpert Hub CoreTec 4, that depends on a token validation of the session identifier, allows an unauthorized modified message to be executed in the server enabling an unauthorized actor to change an existing user password, and further gain authorized access into the system via login mechanism. This issue affects: Hitachi Energy TXpert Hub CoreTec 4 version 2.0.0 2.1.0; 2.1.0; 2.1.1; 2.1.2; 2.1.3; 2.2.0; 2.2.1."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-288 Authentication Bypass Using an Alternate Path or Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000080\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026utm_campaign=\u0026utm_content=2022.04_5763_Cybersecurity%20Advisory%20Update_May_03\u0026utm_medium=email\u0026utm_source=Eloqua",
"refsource": "CONFIRM",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000080\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026utm_campaign=\u0026utm_content=2022.04_5763_Cybersecurity%20Advisory%20Update_May_03\u0026utm_medium=email\u0026utm_source=Eloqua"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update the system to TXpert Hub CoreTec 4 version 2.3.0 that fixes the issues."
}
],
"source": {
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2021-35530",
"datePublished": "2022-06-07T20:17:07.848Z",
"dateReserved": "2021-06-28T00:00:00.000Z",
"dateUpdated": "2024-09-16T23:26:19.387Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-36308 (GCVE-0-2021-36308)
Vulnerability from cvelistv5 – Published: 2021-11-20 01:40 – Updated: 2024-09-16 18:55- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/000193076 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Networking OS |
Affected:
unspecified , < OS10 10.4.3.8,OS10 10.5.0.6C3,OS10 10.5.0.10,OS10 10.5.1.10,OS10 10.5.2.8,OS10 10.5.3.0P1,OS10 10.5.2.3kcc
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:54:51.392Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000193076"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Networking OS",
"vendor": "Dell",
"versions": [
{
"lessThan": "OS10 10.4.3.8,OS10 10.5.0.6C3,OS10 10.5.0.10,OS10 10.5.1.10,OS10 10.5.2.8,OS10 10.5.3.0P1,OS10 10.5.2.3kcc",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-11-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Networking OS10, versions prior to October 2021 with Smart Fabric Services enabled, contains an authentication bypass vulnerability. A remote unauthenticated attacker could exploit this vulnerability to gain access and perform actions on the affected system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-20T01:40:20.000Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000193076"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-11-01",
"ID": "CVE-2021-36308",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Networking OS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "OS10 10.4.3.8,OS10 10.5.0.6C3,OS10 10.5.0.10,OS10 10.5.1.10,OS10 10.5.2.8,OS10 10.5.3.0P1,OS10 10.5.2.3kcc"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Networking OS10, versions prior to October 2021 with Smart Fabric Services enabled, contains an authentication bypass vulnerability. A remote unauthenticated attacker could exploit this vulnerability to gain access and perform actions on the affected system."
}
]
},
"impact": {
"cvss": {
"baseScore": 5.9,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-288: Authentication Bypass Using an Alternate Path or Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/en-us/000193076",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/en-us/000193076"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-36308",
"datePublished": "2021-11-20T01:40:20.366Z",
"dateReserved": "2021-07-08T00:00:00.000Z",
"dateUpdated": "2024-09-16T18:55:12.374Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-3849 (GCVE-0-2021-3849)
Vulnerability from cvelistv5 – Published: 2022-04-22 21:10 – Updated: 2024-08-03 17:09- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/product_security… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | Fan Power Controller2 (FPC2) |
Affected:
various
|
|
| Lenovo | Lenovo System Management Module (SMM) |
Affected:
various
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:09:09.602Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-72615"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Fan Power Controller2 (FPC2)",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
},
{
"product": "Lenovo System Management Module (SMM)",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An authentication bypass vulnerability was discovered in the web interface of the Lenovo Fan Power Controller2 (FPC2) and Lenovo System Management Module (SMM) firmware that could allow an unauthenticated attacker to execute commands on the SMM and FPC2. SMM2 is not affected."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288 Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-22T21:10:11.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-72615"
}
],
"solutions": [
{
"lang": "en",
"value": "Upgrade to the firmware version (or newer) indicated for your model in the Product Impact section in LEN-72615."
}
],
"source": {
"advisory": "LEN-72615",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"ID": "CVE-2021-3849",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Fan Power Controller2 (FPC2)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "various"
}
]
}
},
{
"product_name": "Lenovo System Management Module (SMM)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "various"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An authentication bypass vulnerability was discovered in the web interface of the Lenovo Fan Power Controller2 (FPC2) and Lenovo System Management Module (SMM) firmware that could allow an unauthenticated attacker to execute commands on the SMM and FPC2. SMM2 is not affected."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-288 Authentication Bypass Using an Alternate Path or Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-72615",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-72615"
}
]
},
"solution": [
{
"lang": "en",
"value": "Upgrade to the firmware version (or newer) indicated for your model in the Product Impact section in LEN-72615."
}
],
"source": {
"advisory": "LEN-72615",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2021-3849",
"datePublished": "2022-04-22T21:10:11.000Z",
"dateReserved": "2021-10-01T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:09:09.602Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-3897 (GCVE-0-2021-3897)
Vulnerability from cvelistv5 – Published: 2022-04-22 21:10 – Updated: 2024-08-03 17:09- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/product_security… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Lenovo | Fan Power Controller2 (FPC2) |
Affected:
various
|
|
| Lenovo | Lenovo System Management Module (SMM) |
Affected:
various
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:09:09.641Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-72615"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Fan Power Controller2 (FPC2)",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
},
{
"product": "Lenovo System Management Module (SMM)",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An authentication bypass vulnerability was discovered in an internal service of the Lenovo Fan Power Controller2 (FPC2) and Lenovo System Management Module (SMM) firmware during an that could allow an unauthenticated attacker to execute commands on the SMM and FPC2. SMM2 is not affected."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288 Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-22T21:10:13.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-72615"
}
],
"solutions": [
{
"lang": "en",
"value": "Upgrade to the firmware version (or newer) indicated for your model in the Product Impact section in LEN-72615."
}
],
"source": {
"advisory": "LEN-72615",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"ID": "CVE-2021-3897",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Fan Power Controller2 (FPC2)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "various"
}
]
}
},
{
"product_name": "Lenovo System Management Module (SMM)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "various"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An authentication bypass vulnerability was discovered in an internal service of the Lenovo Fan Power Controller2 (FPC2) and Lenovo System Management Module (SMM) firmware during an that could allow an unauthenticated attacker to execute commands on the SMM and FPC2. SMM2 is not affected."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-288 Authentication Bypass Using an Alternate Path or Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-72615",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-72615"
}
]
},
"solution": [
{
"lang": "en",
"value": "Upgrade to the firmware version (or newer) indicated for your model in the Product Impact section in LEN-72615."
}
],
"source": {
"advisory": "LEN-72615",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2021-3897",
"datePublished": "2022-04-22T21:10:13.000Z",
"dateReserved": "2021-10-22T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:09:09.641Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-41292 (GCVE-0-2021-41292)
Vulnerability from cvelistv5 – Published: 2021-09-30 10:40 – Updated: 2024-09-17 03:32- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
| URL | Tags |
|---|---|
| https://www.twcert.org.tw/tw/cp-132-5128-b075a-1.html | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| ECOA | ECS Router Controller ECS (FLASH) |
Unknown:
next of 0 , < unspecified
(custom)
|
|
| ECOA | RiskBuster Terminator E6L45 |
Unknown:
next of 0 , < unspecified
(custom)
|
|
| ECOA | RiskBuster System RB 3.0.0 |
Unknown:
next of 0 , < unspecified
(custom)
|
|
| ECOA | RiskBuster System TRANE 1.0 |
Unknown:
next of 0 , < unspecified
(custom)
|
|
| ECOA | Graphic Control Software |
Unknown:
next of 0 , < unspecified
(custom)
|
|
| ECOA | SmartHome II E9246 |
Unknown:
next of 0 , < unspecified
(custom)
|
|
| ECOA | RiskTerminator |
Unknown:
next of 0 , < unspecified
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T03:08:31.993Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.twcert.org.tw/tw/cp-132-5128-b075a-1.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "ECS Router Controller ECS (FLASH)",
"vendor": "ECOA",
"versions": [
{
"lessThan": "unspecified",
"status": "unknown",
"version": "next of 0",
"versionType": "custom"
}
]
},
{
"product": "RiskBuster Terminator E6L45",
"vendor": "ECOA",
"versions": [
{
"lessThan": "unspecified",
"status": "unknown",
"version": "next of 0",
"versionType": "custom"
}
]
},
{
"product": "RiskBuster System RB 3.0.0",
"vendor": "ECOA",
"versions": [
{
"lessThan": "unspecified",
"status": "unknown",
"version": "next of 0",
"versionType": "custom"
}
]
},
{
"product": "RiskBuster System TRANE 1.0",
"vendor": "ECOA",
"versions": [
{
"lessThan": "unspecified",
"status": "unknown",
"version": "next of 0",
"versionType": "custom"
}
]
},
{
"product": "Graphic Control Software",
"vendor": "ECOA",
"versions": [
{
"lessThan": "unspecified",
"status": "unknown",
"version": "next of 0",
"versionType": "custom"
}
]
},
{
"product": "SmartHome II E9246",
"vendor": "ECOA",
"versions": [
{
"lessThan": "unspecified",
"status": "unknown",
"version": "next of 0",
"versionType": "custom"
}
]
},
{
"product": "RiskTerminator",
"vendor": "ECOA",
"versions": [
{
"lessThan": "unspecified",
"status": "unknown",
"version": "next of 0",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-09-30T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "ECOA BAS controller suffers from an authentication bypass vulnerability. An unauthenticated attacker through cookie poisoning can remotely bypass authentication and disclose sensitive information and circumvent physical access controls in smart homes and buildings and manipulate HVAC."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288 Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-30T10:40:52.000Z",
"orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"shortName": "twcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.twcert.org.tw/tw/cp-132-5128-b075a-1.html"
}
],
"solutions": [
{
"lang": "en",
"value": "Contact tech support from ECOA."
}
],
"source": {
"advisory": "TVN-202109008",
"discovery": "EXTERNAL"
},
"title": "ECOA BAS controller - Broken Authentication",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"AKA": "TWCERT/CC",
"ASSIGNER": "cve@cert.org.tw",
"DATE_PUBLIC": "2021-09-30T10:13:00.000Z",
"ID": "CVE-2021-41292",
"STATE": "PUBLIC",
"TITLE": "ECOA BAS controller - Broken Authentication"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ECS Router Controller ECS (FLASH)",
"version": {
"version_data": [
{
"version_affected": "?\u003e",
"version_value": "0"
}
]
}
},
{
"product_name": "RiskBuster Terminator E6L45",
"version": {
"version_data": [
{
"version_affected": "?\u003e",
"version_value": "0"
}
]
}
},
{
"product_name": "RiskBuster System RB 3.0.0",
"version": {
"version_data": [
{
"version_affected": "?\u003e",
"version_value": "0"
}
]
}
},
{
"product_name": "RiskBuster System TRANE 1.0",
"version": {
"version_data": [
{
"version_affected": "?\u003e",
"version_value": "0"
}
]
}
},
{
"product_name": "Graphic Control Software",
"version": {
"version_data": [
{
"version_affected": "?\u003e",
"version_value": "0"
}
]
}
},
{
"product_name": "SmartHome II E9246",
"version": {
"version_data": [
{
"version_affected": "?\u003e",
"version_value": "0"
}
]
}
},
{
"product_name": "RiskTerminator",
"version": {
"version_data": [
{
"version_affected": "?\u003e",
"version_value": "0"
}
]
}
}
]
},
"vendor_name": "ECOA"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "ECOA BAS controller suffers from an authentication bypass vulnerability. An unauthenticated attacker through cookie poisoning can remotely bypass authentication and disclose sensitive information and circumvent physical access controls in smart homes and buildings and manipulate HVAC."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-288 Authentication Bypass Using an Alternate Path or Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.twcert.org.tw/tw/cp-132-5128-b075a-1.html",
"refsource": "MISC",
"url": "https://www.twcert.org.tw/tw/cp-132-5128-b075a-1.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "Contact tech support from ECOA."
}
],
"source": {
"advisory": "TVN-202109008",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"assignerShortName": "twcert",
"cveId": "CVE-2021-41292",
"datePublished": "2021-09-30T10:40:52.625Z",
"dateReserved": "2021-09-15T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:32:30.239Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-41992 (GCVE-0-2021-41992)
Vulnerability from cvelistv5 – Published: 2022-04-30 21:15 – Updated: 2024-08-04 03:22| URL | Tags |
|---|---|
| https://www.pingidentity.com/en/resources/downloa… | x_refsource_MISC |
| https://docs.pingidentity.com/bundle/pingid/page/… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Ping Identity | PingID Windows Login |
Affected:
unspecified , < 2.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T03:22:25.674Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.pingidentity.com/en/resources/downloads/pingid.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://docs.pingidentity.com/bundle/pingid/page/klc1641469599716.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"platforms": [
"Windows"
],
"product": "PingID Windows Login",
"vendor": "Ping Identity",
"versions": [
{
"lessThan": "2.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Ping Identity credits The Commonwealth Bank of Australia for the discovery of this vulnerability."
}
],
"descriptions": [
{
"lang": "en",
"value": "A misconfiguration of RSA in PingID Windows Login prior to 2.7 is vulnerable to pre-computed dictionary attacks, leading to an offline MFA bypass."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-310",
"description": "CWE-310 Cryptographic Issues",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288 Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-30T21:15:19.000Z",
"orgId": "5998a2e9-ae88-42cd-b6e0-7564fd979f9e",
"shortName": "Ping Identity"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.pingidentity.com/en/resources/downloads/pingid.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://docs.pingidentity.com/bundle/pingid/page/klc1641469599716.html"
}
],
"source": {
"advisory": "SECADV030",
"discovery": "EXTERNAL"
},
"title": "PingID Windows Login RSA cryptographic weakness with possible offline MFA bypass",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "responsible-disclosure@pingidentity.com",
"ID": "CVE-2021-41992",
"STATE": "PUBLIC",
"TITLE": "PingID Windows Login RSA cryptographic weakness with possible offline MFA bypass"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PingID Windows Login",
"version": {
"version_data": [
{
"platform": "Windows",
"version_affected": "\u003c",
"version_value": "2.7"
}
]
}
}
]
},
"vendor_name": "Ping Identity"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Ping Identity credits The Commonwealth Bank of Australia for the discovery of this vulnerability."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A misconfiguration of RSA in PingID Windows Login prior to 2.7 is vulnerable to pre-computed dictionary attacks, leading to an offline MFA bypass."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-310 Cryptographic Issues"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-288 Authentication Bypass Using an Alternate Path or Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.pingidentity.com/en/resources/downloads/pingid.html",
"refsource": "MISC",
"url": "https://www.pingidentity.com/en/resources/downloads/pingid.html"
},
{
"name": "https://docs.pingidentity.com/bundle/pingid/page/klc1641469599716.html",
"refsource": "MISC",
"url": "https://docs.pingidentity.com/bundle/pingid/page/klc1641469599716.html"
}
]
},
"source": {
"advisory": "SECADV030",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5998a2e9-ae88-42cd-b6e0-7564fd979f9e",
"assignerShortName": "Ping Identity",
"cveId": "CVE-2021-41992",
"datePublished": "2022-04-30T21:15:19.000Z",
"dateReserved": "2021-10-04T00:00:00.000Z",
"dateUpdated": "2024-08-04T03:22:25.674Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
Phase: Architecture and Design
Description:
- Funnel all access through a single choke point to simplify how users can access a resource. For every access, perform a check to determine if the user has permissions to access the resource.
CAPEC-127: Directory Indexing
An adversary crafts a request to a target that results in the target listing/indexing the content of a directory as output. One common method of triggering directory contents as output is to construct a request containing a path that terminates in a directory name rather than a file name since many applications are configured to provide a list of the directory's contents when such a request is received. An adversary can use this to explore the directory tree on a target as well as learn the names of files. This can often end up revealing test files, backup files, temporary files, hidden files, configuration files, user accounts, script contents, as well as naming conventions, all of which can be used by an attacker to mount additional attacks.
CAPEC-665: Exploitation of Thunderbolt Protection Flaws
An adversary leverages a firmware weakness within the Thunderbolt protocol, on a computing device to manipulate Thunderbolt controller firmware in order to exploit vulnerabilities in the implementation of authorization and verification schemes within Thunderbolt protection mechanisms. Upon gaining physical access to a target device, the adversary conducts high-level firmware manipulation of the victim Thunderbolt controller SPI (Serial Peripheral Interface) flash, through the use of a SPI Programing device and an external Thunderbolt device, typically as the target device is booting up. If successful, this allows the adversary to modify memory, subvert authentication mechanisms, spoof identities and content, and extract data and memory from the target device. Currently 7 major vulnerabilities exist within Thunderbolt protocol with 9 attack vectors as noted in the Execution Flow.