Search criteria

74 vulnerabilities found for AC10U by Tenda

CVE-2024-10280 (GCVE-0-2024-10280)

Vulnerability from cvelistv5 – Published: 2024-10-23 13:31 – Updated: 2024-10-23 17:41
VLAI?
Title
Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference
Summary
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CWE
  • CWE-476 - NULL Pointer Dereference
Assigner
References
Credits
minipython (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac6_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.23"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac8_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.34.06"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac8_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.34.09"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.48.23"
              },
              {
                "status": "affected",
                "version": "16.03.48.19"
              },
              {
                "status": "affected",
                "version": "16.03.48.20"
              },
              {
                "status": "affected",
                "version": "16.03.48.13"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.23"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.42"
              },
              {
                "status": "affected",
                "version": "15.03.05.19\\(6318_\\)"
              },
              {
                "status": "affected",
                "version": "15.03.05.14"
              },
              {
                "status": "affected",
                "version": "15.03.2.13"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.05"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.19\\(6318\\)"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "2.0.1.9\\(1307\\)"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.0.16"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.0.14"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.48"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.49"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.44"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.18"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.19"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10280",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T17:28:19.760214Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-23T17:41:57.370Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC6",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC7",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC8",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC15",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC500",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC1206",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "minipython (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 bis 20241022 ausgemacht. Sie wurde als problematisch eingestuft. Davon betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.8,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-23T13:31:07.315Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281555 | Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281555"
        },
        {
          "name": "VDB-281555 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281555"
        },
        {
          "name": "Submit #426417 | Tenda AC8v4 V16.03.34.06 NULL Pointer Dereference",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.426417"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-23T08:07:55.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10280",
    "datePublished": "2024-10-23T13:31:07.315Z",
    "dateReserved": "2024-10-23T06:02:03.363Z",
    "dateUpdated": "2024-10-23T17:41:57.370Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2853 (GCVE-0-2024-2853)

Vulnerability from cvelistv5 – Published: 2024-03-24 05:00 – Updated: 2024-08-01 19:25
VLAI?
Title
Tenda AC10U setsambacfg formSetSambaConf os command injection
Summary
A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-78 - OS Command Injection
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10U Affected: 15.03.06.48
Affected: 15.03.06.49
Create a notification for this product.
Credits
wxhwxhwxh_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
              "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.48_multi_tde01:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tendacn",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.48_multi_tde01"
              },
              {
                "status": "affected",
                "version": "15.03.06.49_multi_tde01"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2853",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-25T14:19:55.063616Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-01T18:29:31.431Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:42.158Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257777 | Tenda AC10U setsambacfg formSetSambaConf os command injection",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257777"
          },
          {
            "name": "VDB-257777 | CTI Indicators (IOB, IOC, TTP, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257777"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetSambaConf.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.48"
            },
            {
              "status": "affected",
              "version": "15.03.06.49"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC10U 15.03.06.48/15.03.06.49 ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion formSetSambaConf der Datei /goform/setsambacfg. Durch die Manipulation des Arguments usbName mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-24T05:00:06.892Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257777 | Tenda AC10U setsambacfg formSetSambaConf os command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257777"
        },
        {
          "name": "VDB-257777 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257777"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetSambaConf.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-23T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-23T06:52:17.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10U setsambacfg formSetSambaConf os command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2853",
    "datePublished": "2024-03-24T05:00:06.892Z",
    "dateReserved": "2024-03-23T05:47:14.178Z",
    "dateUpdated": "2024-08-01T19:25:42.158Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2764 (GCVE-0-2024-2764)

Vulnerability from cvelistv5 – Published: 2024-03-21 20:31 – Updated: 2024-08-02 13:57
VLAI?
Title
Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10U Affected: 15.03.06.48
Create a notification for this product.
Credits
yhryhryhr_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:41.687Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257601 | Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257601"
          },
          {
            "name": "VDB-257601 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257601"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetPPTPServer.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.48_multi_tde01:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tendacn",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.48_multi_tde01"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2764",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-22T14:41:42.917825Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-02T13:57:14.115Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.48"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda AC10U 15.03.06.48 gefunden. Hiervon betroffen ist die Funktion formSetPPTPServer der Datei /goform/SetPptpServerCfg. Durch die Manipulation des Arguments endIP mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-21T20:31:05.130Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257601 | Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257601"
        },
        {
          "name": "VDB-257601 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257601"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetPPTPServer.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-21T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-21T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-21T16:22:56.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2764",
    "datePublished": "2024-03-21T20:31:05.130Z",
    "dateReserved": "2024-03-21T15:17:47.961Z",
    "dateUpdated": "2024-08-02T13:57:14.115Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2763 (GCVE-0-2024-2763)

Vulnerability from cvelistv5 – Published: 2024-03-21 20:31 – Updated: 2024-08-01 19:25
VLAI?
Title
Tenda AC10U setcfm formSetCfm stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10U Affected: 15.03.06.48
Create a notification for this product.
Credits
yhryhryhr_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2763",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-22T17:49:42.492927Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-05T17:21:16.064Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:41.329Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257600 | Tenda AC10U setcfm formSetCfm stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257600"
          },
          {
            "name": "VDB-257600 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257600"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetCfm.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.48"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda AC10U 15.03.06.48 entdeckt. Davon betroffen ist die Funktion formSetCfm der Datei goform/setcfm. Mit der Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-21T20:31:03.792Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257600 | Tenda AC10U setcfm formSetCfm stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257600"
        },
        {
          "name": "VDB-257600 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257600"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetCfm.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-21T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-21T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-21T16:22:54.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10U setcfm formSetCfm stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2763",
    "datePublished": "2024-03-21T20:31:03.792Z",
    "dateReserved": "2024-03-21T15:17:45.636Z",
    "dateUpdated": "2024-08-01T19:25:41.329Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2711 (GCVE-0-2024-2711)

Vulnerability from cvelistv5 – Published: 2024-03-20 18:00 – Updated: 2024-08-21 22:56
VLAI?
Title
Tenda AC10U addWifiMacFilter stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10U Affected: 15.03.06.48
Create a notification for this product.
Credits
yhryhryhr_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:18:48.437Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257462 | Tenda AC10U addWifiMacFilter stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257462"
          },
          {
            "name": "VDB-257462 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257462"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/addWifiMacFilter_deviceMac.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.48"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2711",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-20T19:33:40.489082Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-21T22:56:23.392Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.48"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda AC10U 15.03.06.48 ausgemacht. Dies betrifft die Funktion addWifiMacFilter der Datei /goform/addWifiMacFilter. Durch das Manipulieren des Arguments deviceMac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-20T18:00:08.616Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257462 | Tenda AC10U addWifiMacFilter stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257462"
        },
        {
          "name": "VDB-257462 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257462"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/addWifiMacFilter_deviceMac.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-20T10:56:35.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10U addWifiMacFilter stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2711",
    "datePublished": "2024-03-20T18:00:08.616Z",
    "dateReserved": "2024-03-20T09:51:32.403Z",
    "dateUpdated": "2024-08-21T22:56:23.392Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2710 (GCVE-0-2024-2710)

Vulnerability from cvelistv5 – Published: 2024-03-20 18:00 – Updated: 2024-08-21 22:59
VLAI?
Title
Tenda AC10U openSchedWifi setSchedWifi stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10U Affected: 15.03.06.49
Create a notification for this product.
Credits
yhryhryhr_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:18:48.443Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257461 | Tenda AC10U openSchedWifi setSchedWifi stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257461"
          },
          {
            "name": "VDB-257461 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257461"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/setSchedWifi_start.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.49"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2710",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-28T19:06:25.531035Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-21T22:59:44.809Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.49"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC10U 15.03.06.49 wurde eine kritische Schwachstelle ausgemacht. Das betrifft die Funktion setSchedWifi der Datei /goform/openSchedWifi. Mittels Manipulieren des Arguments schedStartTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-20T18:00:07.175Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257461 | Tenda AC10U openSchedWifi setSchedWifi stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257461"
        },
        {
          "name": "VDB-257461 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257461"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/setSchedWifi_start.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-20T10:56:20.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10U openSchedWifi setSchedWifi stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2710",
    "datePublished": "2024-03-20T18:00:07.175Z",
    "dateReserved": "2024-03-20T09:51:17.589Z",
    "dateUpdated": "2024-08-21T22:59:44.809Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2709 (GCVE-0-2024-2709)

Vulnerability from cvelistv5 – Published: 2024-03-20 17:31 – Updated: 2024-08-01 19:18
VLAI?
Title
Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10U Affected: 15.03.06.49
Create a notification for this product.
Credits
yhryhryhr_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.49"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2709",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-20T19:56:11.140465Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-30T15:13:58.664Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:18:48.324Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257460 | Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257460"
          },
          {
            "name": "VDB-257460 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257460"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/fromSetRouteStatic.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.49"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda AC10U 15.03.06.49 ausgemacht. Es betrifft die Funktion fromSetRouteStatic der Datei /goform/SetStaticRouteCfg. Mittels dem Manipulieren des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-20T17:31:05.924Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257460 | Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257460"
        },
        {
          "name": "VDB-257460 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257460"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/fromSetRouteStatic.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-20T10:56:06.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2709",
    "datePublished": "2024-03-20T17:31:05.924Z",
    "dateReserved": "2024-03-20T09:51:03.150Z",
    "dateUpdated": "2024-08-01T19:18:48.324Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2708 (GCVE-0-2024-2708)

Vulnerability from cvelistv5 – Published: 2024-03-20 17:31 – Updated: 2024-08-21 23:00
VLAI?
Title
Tenda AC10U execCommand formexeCommand stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10U Affected: 15.03.06.49
Create a notification for this product.
Credits
yhryhryhr_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:18:48.444Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257459 | Tenda AC10U execCommand formexeCommand stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257459"
          },
          {
            "name": "VDB-257459 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257459"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formexeCommand.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.49"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2708",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-21T18:03:42.141392Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-21T23:00:05.639Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.49"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda AC10U 15.03.06.49 gefunden. Hierbei geht es um die Funktion formexeCommand der Datei /goform/execCommand. Durch Manipulation des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-20T17:31:04.520Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257459 | Tenda AC10U execCommand formexeCommand stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257459"
        },
        {
          "name": "VDB-257459 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257459"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formexeCommand.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-20T10:55:55.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10U execCommand formexeCommand stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2708",
    "datePublished": "2024-03-20T17:31:04.520Z",
    "dateReserved": "2024-03-20T09:50:52.265Z",
    "dateUpdated": "2024-08-21T23:00:05.639Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10280 (GCVE-0-2024-10280)

Vulnerability from nvd – Published: 2024-10-23 13:31 – Updated: 2024-10-23 17:41
VLAI?
Title
Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference
Summary
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CWE
  • CWE-476 - NULL Pointer Dereference
Assigner
References
Credits
minipython (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac6_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.23"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac8_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.34.06"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac8_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.34.09"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.48.23"
              },
              {
                "status": "affected",
                "version": "16.03.48.19"
              },
              {
                "status": "affected",
                "version": "16.03.48.20"
              },
              {
                "status": "affected",
                "version": "16.03.48.13"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.23"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.42"
              },
              {
                "status": "affected",
                "version": "15.03.05.19\\(6318_\\)"
              },
              {
                "status": "affected",
                "version": "15.03.05.14"
              },
              {
                "status": "affected",
                "version": "15.03.2.13"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.05"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.19\\(6318\\)"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "2.0.1.9\\(1307\\)"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.0.16"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.0.14"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.48"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.49"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.44"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.18"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.19"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10280",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T17:28:19.760214Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-23T17:41:57.370Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC6",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC7",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC8",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC15",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC500",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC1206",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "minipython (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 bis 20241022 ausgemacht. Sie wurde als problematisch eingestuft. Davon betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.8,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-23T13:31:07.315Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281555 | Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281555"
        },
        {
          "name": "VDB-281555 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281555"
        },
        {
          "name": "Submit #426417 | Tenda AC8v4 V16.03.34.06 NULL Pointer Dereference",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.426417"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-23T08:07:55.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10280",
    "datePublished": "2024-10-23T13:31:07.315Z",
    "dateReserved": "2024-10-23T06:02:03.363Z",
    "dateUpdated": "2024-10-23T17:41:57.370Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2853 (GCVE-0-2024-2853)

Vulnerability from nvd – Published: 2024-03-24 05:00 – Updated: 2024-08-01 19:25
VLAI?
Title
Tenda AC10U setsambacfg formSetSambaConf os command injection
Summary
A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-78 - OS Command Injection
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10U Affected: 15.03.06.48
Affected: 15.03.06.49
Create a notification for this product.
Credits
wxhwxhwxh_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
              "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.48_multi_tde01:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tendacn",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.48_multi_tde01"
              },
              {
                "status": "affected",
                "version": "15.03.06.49_multi_tde01"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2853",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-25T14:19:55.063616Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-01T18:29:31.431Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:42.158Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257777 | Tenda AC10U setsambacfg formSetSambaConf os command injection",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257777"
          },
          {
            "name": "VDB-257777 | CTI Indicators (IOB, IOC, TTP, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257777"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetSambaConf.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.48"
            },
            {
              "status": "affected",
              "version": "15.03.06.49"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC10U 15.03.06.48/15.03.06.49 ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion formSetSambaConf der Datei /goform/setsambacfg. Durch die Manipulation des Arguments usbName mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-24T05:00:06.892Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257777 | Tenda AC10U setsambacfg formSetSambaConf os command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257777"
        },
        {
          "name": "VDB-257777 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257777"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetSambaConf.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-23T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-23T06:52:17.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10U setsambacfg formSetSambaConf os command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2853",
    "datePublished": "2024-03-24T05:00:06.892Z",
    "dateReserved": "2024-03-23T05:47:14.178Z",
    "dateUpdated": "2024-08-01T19:25:42.158Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2764 (GCVE-0-2024-2764)

Vulnerability from nvd – Published: 2024-03-21 20:31 – Updated: 2024-08-02 13:57
VLAI?
Title
Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10U Affected: 15.03.06.48
Create a notification for this product.
Credits
yhryhryhr_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:41.687Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257601 | Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257601"
          },
          {
            "name": "VDB-257601 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257601"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetPPTPServer.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.48_multi_tde01:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tendacn",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.48_multi_tde01"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2764",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-22T14:41:42.917825Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-02T13:57:14.115Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.48"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda AC10U 15.03.06.48 gefunden. Hiervon betroffen ist die Funktion formSetPPTPServer der Datei /goform/SetPptpServerCfg. Durch die Manipulation des Arguments endIP mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-21T20:31:05.130Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257601 | Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257601"
        },
        {
          "name": "VDB-257601 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257601"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetPPTPServer.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-21T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-21T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-21T16:22:56.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2764",
    "datePublished": "2024-03-21T20:31:05.130Z",
    "dateReserved": "2024-03-21T15:17:47.961Z",
    "dateUpdated": "2024-08-02T13:57:14.115Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2763 (GCVE-0-2024-2763)

Vulnerability from nvd – Published: 2024-03-21 20:31 – Updated: 2024-08-01 19:25
VLAI?
Title
Tenda AC10U setcfm formSetCfm stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10U Affected: 15.03.06.48
Create a notification for this product.
Credits
yhryhryhr_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2763",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-22T17:49:42.492927Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-05T17:21:16.064Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:41.329Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257600 | Tenda AC10U setcfm formSetCfm stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257600"
          },
          {
            "name": "VDB-257600 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257600"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetCfm.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.48"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda AC10U 15.03.06.48 entdeckt. Davon betroffen ist die Funktion formSetCfm der Datei goform/setcfm. Mit der Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-21T20:31:03.792Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257600 | Tenda AC10U setcfm formSetCfm stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257600"
        },
        {
          "name": "VDB-257600 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257600"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetCfm.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-21T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-21T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-21T16:22:54.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10U setcfm formSetCfm stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2763",
    "datePublished": "2024-03-21T20:31:03.792Z",
    "dateReserved": "2024-03-21T15:17:45.636Z",
    "dateUpdated": "2024-08-01T19:25:41.329Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2711 (GCVE-0-2024-2711)

Vulnerability from nvd – Published: 2024-03-20 18:00 – Updated: 2024-08-21 22:56
VLAI?
Title
Tenda AC10U addWifiMacFilter stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10U Affected: 15.03.06.48
Create a notification for this product.
Credits
yhryhryhr_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:18:48.437Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257462 | Tenda AC10U addWifiMacFilter stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257462"
          },
          {
            "name": "VDB-257462 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257462"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/addWifiMacFilter_deviceMac.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.48"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2711",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-20T19:33:40.489082Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-21T22:56:23.392Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.48"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda AC10U 15.03.06.48 ausgemacht. Dies betrifft die Funktion addWifiMacFilter der Datei /goform/addWifiMacFilter. Durch das Manipulieren des Arguments deviceMac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-20T18:00:08.616Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257462 | Tenda AC10U addWifiMacFilter stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257462"
        },
        {
          "name": "VDB-257462 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257462"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/addWifiMacFilter_deviceMac.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-20T10:56:35.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10U addWifiMacFilter stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2711",
    "datePublished": "2024-03-20T18:00:08.616Z",
    "dateReserved": "2024-03-20T09:51:32.403Z",
    "dateUpdated": "2024-08-21T22:56:23.392Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2710 (GCVE-0-2024-2710)

Vulnerability from nvd – Published: 2024-03-20 18:00 – Updated: 2024-08-21 22:59
VLAI?
Title
Tenda AC10U openSchedWifi setSchedWifi stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10U Affected: 15.03.06.49
Create a notification for this product.
Credits
yhryhryhr_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:18:48.443Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257461 | Tenda AC10U openSchedWifi setSchedWifi stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257461"
          },
          {
            "name": "VDB-257461 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257461"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/setSchedWifi_start.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.49"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2710",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-28T19:06:25.531035Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-21T22:59:44.809Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.49"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC10U 15.03.06.49 wurde eine kritische Schwachstelle ausgemacht. Das betrifft die Funktion setSchedWifi der Datei /goform/openSchedWifi. Mittels Manipulieren des Arguments schedStartTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-20T18:00:07.175Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257461 | Tenda AC10U openSchedWifi setSchedWifi stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257461"
        },
        {
          "name": "VDB-257461 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257461"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/setSchedWifi_start.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-20T10:56:20.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10U openSchedWifi setSchedWifi stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2710",
    "datePublished": "2024-03-20T18:00:07.175Z",
    "dateReserved": "2024-03-20T09:51:17.589Z",
    "dateUpdated": "2024-08-21T22:59:44.809Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2709 (GCVE-0-2024-2709)

Vulnerability from nvd – Published: 2024-03-20 17:31 – Updated: 2024-08-01 19:18
VLAI?
Title
Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10U Affected: 15.03.06.49
Create a notification for this product.
Credits
yhryhryhr_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.49"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2709",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-20T19:56:11.140465Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-30T15:13:58.664Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:18:48.324Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257460 | Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257460"
          },
          {
            "name": "VDB-257460 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257460"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/fromSetRouteStatic.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.49"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda AC10U 15.03.06.49 ausgemacht. Es betrifft die Funktion fromSetRouteStatic der Datei /goform/SetStaticRouteCfg. Mittels dem Manipulieren des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-20T17:31:05.924Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257460 | Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257460"
        },
        {
          "name": "VDB-257460 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257460"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/fromSetRouteStatic.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-20T10:56:06.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2709",
    "datePublished": "2024-03-20T17:31:05.924Z",
    "dateReserved": "2024-03-20T09:51:03.150Z",
    "dateUpdated": "2024-08-01T19:18:48.324Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2708 (GCVE-0-2024-2708)

Vulnerability from nvd – Published: 2024-03-20 17:31 – Updated: 2024-08-21 23:00
VLAI?
Title
Tenda AC10U execCommand formexeCommand stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda AC10U Affected: 15.03.06.49
Create a notification for this product.
Credits
yhryhryhr_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:18:48.444Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257459 | Tenda AC10U execCommand formexeCommand stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257459"
          },
          {
            "name": "VDB-257459 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257459"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formexeCommand.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.49"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2708",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-21T18:03:42.141392Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-21T23:00:05.639Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.49"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda AC10U 15.03.06.49 gefunden. Hierbei geht es um die Funktion formexeCommand der Datei /goform/execCommand. Durch Manipulation des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-20T17:31:04.520Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257459 | Tenda AC10U execCommand formexeCommand stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257459"
        },
        {
          "name": "VDB-257459 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257459"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formexeCommand.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-20T10:55:55.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10U execCommand formexeCommand stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2708",
    "datePublished": "2024-03-20T17:31:04.520Z",
    "dateReserved": "2024-03-20T09:50:52.265Z",
    "dateUpdated": "2024-08-21T23:00:05.639Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

VAR-202403-0931

Vulnerability from variot - Updated: 2024-06-07 23:02

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda AC10U is a wireless router from China's Tenda company. The vulnerability is caused by the parameter funcpara1 of the function formSetCfm in the file goform/setcfm failing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0931",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.06.48"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-26325"
      }
    ]
  },
  "cve": "CVE-2024-2763",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2024-26325",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-2763",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-26325",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-26325"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2763"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda AC10U is a wireless router from China\u0027s Tenda company. The vulnerability is caused by the parameter funcpara1 of the function formSetCfm in the file goform/setcfm failing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-2763"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-26325"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-2763",
        "trust": 1.6
      },
      {
        "db": "VULDB",
        "id": "257600",
        "trust": 1.0
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-26325",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-26325"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2763"
      }
    ]
  },
  "id": "VAR-202403-0931",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-26325"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-26325"
      }
    ]
  },
  "last_update_date": "2024-06-07T23:02:52.327000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-2763"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.0,
        "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac10u/v1.v15.03.06.48/more/formsetcfm.md"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.257600"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?id.257600"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2763"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-26325"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2763"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-26325"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2763"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-06-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-26325"
      },
      {
        "date": "2024-03-21T21:15:10.790000",
        "db": "NVD",
        "id": "CVE-2024-2763"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-06-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-26325"
      },
      {
        "date": "2024-05-17T02:38:28.787000",
        "db": "NVD",
        "id": "CVE-2024-2763"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC10U formSetCfm function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-26325"
      }
    ],
    "trust": 0.6
  }
}

VAR-202401-1150

Vulnerability from variot - Updated: 2024-05-17 23:12

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been declared as critical. Affected by this vulnerability is the function fromDhcpListClient. The manipulation of the argument page/listN leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the page/listN parameter of the fromDhcpListClient function failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to overflow the buffer and execute arbitrary code on the system

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1150",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.49_multi_tde01"
      },
      {
        "model": "ac10u",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac10u  firmware  15.03.06.49 multi tde01"
      },
      {
        "model": "ac10u 15.03.06.49 multi tde01",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-16942"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001964"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0928"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0928"
      }
    ]
  },
  "cve": "CVE-2024-0928",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.4,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.4,
            "id": "CNVD-2024-16942",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.2,
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-0928",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2024-0928",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-0928",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-16942",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-16942"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001964"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0928"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0928"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been declared as critical. Affected by this vulnerability is the function fromDhcpListClient. The manipulation of the argument page/listN leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the page/listN parameter of the fromDhcpListClient function failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to overflow the buffer and execute arbitrary code on the system",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0928"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001964"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-16942"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-0928",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "252133",
        "trust": 1.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001964",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-16942",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-16942"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001964"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0928"
      }
    ]
  },
  "id": "VAR-202401-1150",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-16942"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-16942"
      }
    ]
  },
  "last_update_date": "2024-05-17T23:12:03.997000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001964"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0928"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/yaoyue123/iot/blob/main/tenda/ac10u/fromdhcplistclient_1.md"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-0928"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.252133"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?id.252133"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-16942"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001964"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0928"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-16942"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001964"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0928"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-04-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-16942"
      },
      {
        "date": "2024-02-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001964"
      },
      {
        "date": "2024-01-26T16:15:21.707000",
        "db": "NVD",
        "id": "CVE-2024-0928"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-04-08T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-16942"
      },
      {
        "date": "2024-02-07T03:07:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001964"
      },
      {
        "date": "2024-05-17T02:35:04.107000",
        "db": "NVD",
        "id": "CVE-2024-0928"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC10U\u00a0 Stack-based buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001964"
      }
    ],
    "trust": 0.8
  }
}

VAR-202401-1091

Vulnerability from variot - Updated: 2024-05-17 23:09

A vulnerability has been found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. This vulnerability affects the function formSetVirtualSer. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-252130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10 is a wireless router made by China Tenda Company

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1091",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.49_multi_tde01"
      },
      {
        "model": "ac10u",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac10u  firmware  15.03.06.49 multi tde01"
      },
      {
        "model": "ac10u 15.03.06.49 multi tde01",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10427"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002001"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0925"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0925"
      }
    ]
  },
  "cve": "CVE-2024-0925",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.4,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2024-10427",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.2,
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-0925",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2024-0925",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-0925",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-10427",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10427"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002001"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0925"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0925"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. This vulnerability affects the function formSetVirtualSer. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-252130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10 is a wireless router made by China Tenda Company",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0925"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002001"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-10427"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-0925",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "252130",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002001",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-10427",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10427"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002001"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0925"
      }
    ]
  },
  "id": "VAR-202401-1091",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10427"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10427"
      }
    ]
  },
  "last_update_date": "2024-05-17T23:09:38.559000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002001"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0925"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/yaoyue123/iot/blob/main/tenda/ac10u/formsetvirtualser.md"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.252130"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-0925"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.252130"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10427"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002001"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0925"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10427"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002001"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0925"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-02-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-10427"
      },
      {
        "date": "2024-02-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-002001"
      },
      {
        "date": "2024-01-26T15:15:08.770000",
        "db": "NVD",
        "id": "CVE-2024-0925"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-02-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-10427"
      },
      {
        "date": "2024-02-07T04:38:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-002001"
      },
      {
        "date": "2024-05-17T02:35:03.683000",
        "db": "NVD",
        "id": "CVE-2024-0925"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC10U\u00a0 Stack-based buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002001"
      }
    ],
    "trust": 0.8
  }
}

VAR-202401-1133

Vulnerability from variot - Updated: 2024-05-17 23:09

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. Affected by this issue is the function formSetDeviceName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252128. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10U is a wireless router made by the Chinese company Tenda

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1133",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.49_multi_tde01"
      },
      {
        "model": "ac10u",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac10u  firmware  15.03.06.49 multi tde01"
      },
      {
        "model": "ac10u 15.03.06.49 multi tde01",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10426"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001995"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0923"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0923"
      }
    ]
  },
  "cve": "CVE-2024-0923",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.4,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2024-10426",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.2,
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-0923",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2024-0923",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-0923",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-10426",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10426"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001995"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0923"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0923"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. Affected by this issue is the function formSetDeviceName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252128. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10U is a wireless router made by the Chinese company Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0923"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001995"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-10426"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-0923",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "252128",
        "trust": 1.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001995",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-10426",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10426"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001995"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0923"
      }
    ]
  },
  "id": "VAR-202401-1133",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10426"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10426"
      }
    ]
  },
  "last_update_date": "2024-05-17T23:09:38.537000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001995"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0923"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/yaoyue123/iot/blob/main/tenda/ac10u/formsetdevicename.md"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-0923"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.252128"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?id.252128"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10426"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001995"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0923"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10426"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001995"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0923"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-02-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-10426"
      },
      {
        "date": "2024-02-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001995"
      },
      {
        "date": "2024-01-26T14:15:50.747000",
        "db": "NVD",
        "id": "CVE-2024-0923"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-02-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-10426"
      },
      {
        "date": "2024-02-07T04:37:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001995"
      },
      {
        "date": "2024-05-17T02:35:03.467000",
        "db": "NVD",
        "id": "CVE-2024-0923"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC10U\u00a0 Stack-based buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001995"
      }
    ],
    "trust": 0.8
  }
}

VAR-202401-1090

Vulnerability from variot - Updated: 2024-05-17 23:03

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been classified as critical. Affected is the function fromAddressNat. The manipulation of the argument entrys/mitInterface/page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the Entrys/mitInterface/page parameter of the fromAddressNat function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to overflow the buffer and execute arbitrary code on the system

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1090",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.49_multi_tde01"
      },
      {
        "model": "ac10u",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac10u  firmware  15.03.06.49 multi tde01"
      },
      {
        "model": "ac10u 15.03.06.49 multi tde01",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-16941"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001999"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0927"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0927"
      }
    ]
  },
  "cve": "CVE-2024-0927",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.4,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.4,
            "id": "CNVD-2024-16941",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.2,
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-0927",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2024-0927",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-0927",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-16941",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-16941"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001999"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0927"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0927"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been classified as critical. Affected is the function fromAddressNat. The manipulation of the argument entrys/mitInterface/page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the Entrys/mitInterface/page parameter of the fromAddressNat function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to overflow the buffer and execute arbitrary code on the system",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0927"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001999"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-16941"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-0927",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "252132",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001999",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-16941",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-16941"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001999"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0927"
      }
    ]
  },
  "id": "VAR-202401-1090",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-16941"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-16941"
      }
    ]
  },
  "last_update_date": "2024-05-17T23:03:14.477000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001999"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0927"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/yaoyue123/iot/blob/main/tenda/ac10u/fromaddressnat_1.md"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.252132"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-0927"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.252132"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-16941"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001999"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0927"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-16941"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001999"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0927"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-04-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-16941"
      },
      {
        "date": "2024-02-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001999"
      },
      {
        "date": "2024-01-26T15:15:09.217000",
        "db": "NVD",
        "id": "CVE-2024-0927"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-04-08T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-16941"
      },
      {
        "date": "2024-02-07T04:38:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001999"
      },
      {
        "date": "2024-05-17T02:35:03.993000",
        "db": "NVD",
        "id": "CVE-2024-0927"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC10U\u00a0 Stack-based buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001999"
      }
    ],
    "trust": 0.8
  }
}

VAR-202401-1132

Vulnerability from variot - Updated: 2024-05-17 23:03

A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function formSetPPTPServer. The manipulation of the argument startIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of ac10u A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the startIp parameter of the formSetPPTPServer function failing to correctly verify the length of the input data. An attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1132",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.49_multi_tde01"
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac10u  firmware  15.03.06.49 multi tde01"
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u 15.03.06.49 multi tde01",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13798"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002002"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0924"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tenda:ac10u:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0924"
      }
    ]
  },
  "cve": "CVE-2024-0924",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.4,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2024-13798",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.2,
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-0924",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2024-0924",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-0924",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-13798",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13798"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002002"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0924"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0924"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function formSetPPTPServer. The manipulation of the argument startIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of ac10u A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the startIp parameter of the formSetPPTPServer function failing to correctly verify the length of the input data. An attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0924"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002002"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-13798"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-0924",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "252129",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002002",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-13798",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13798"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002002"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0924"
      }
    ]
  },
  "id": "VAR-202401-1132",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13798"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13798"
      }
    ]
  },
  "last_update_date": "2024-05-17T23:03:14.454000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002002"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0924"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/yaoyue123/iot/blob/main/tenda/ac10u/formsetpptpserver.md"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.252129"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-0924"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.252129"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13798"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002002"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0924"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13798"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002002"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0924"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-13798"
      },
      {
        "date": "2024-02-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-002002"
      },
      {
        "date": "2024-01-26T15:15:08.537000",
        "db": "NVD",
        "id": "CVE-2024-0924"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-13798"
      },
      {
        "date": "2024-02-07T04:38:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-002002"
      },
      {
        "date": "2024-05-17T02:35:03.573000",
        "db": "NVD",
        "id": "CVE-2024-0924"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac10u\u00a0 Stack-based buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002002"
      }
    ],
    "trust": 0.8
  }
}

VAR-202401-1144

Vulnerability from variot - Updated: 2024-05-17 23:02

A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. Affected by this vulnerability is the function formQuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10U is a wireless router made by the Chinese company Tenda. A remote attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1144",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.49_multi_tde01"
      },
      {
        "model": "ac10u",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac10u  firmware  15.03.06.49 multi tde01"
      },
      {
        "model": "ac10u 15.03.06.49 multi tde01",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10425"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001996"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0922"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0922"
      }
    ]
  },
  "cve": "CVE-2024-0922",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.4,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2024-10425",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.2,
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-0922",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2024-0922",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-0922",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-10425",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10425"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001996"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0922"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0922"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. Affected by this vulnerability is the function formQuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10U is a wireless router made by the Chinese company Tenda. A remote attacker could exploit this vulnerability to overflow a buffer and execute arbitrary code on the system",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0922"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001996"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-10425"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-0922",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "252127",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001996",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-10425",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10425"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001996"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0922"
      }
    ]
  },
  "id": "VAR-202401-1144",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10425"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10425"
      }
    ]
  },
  "last_update_date": "2024-05-17T23:02:33.298000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001996"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0922"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/yaoyue123/iot/blob/main/tenda/ac10u/formquickindex.md"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.252127"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-0922"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.252127"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10425"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001996"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0922"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-10425"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001996"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0922"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-02-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-10425"
      },
      {
        "date": "2024-02-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001996"
      },
      {
        "date": "2024-01-26T14:15:50.527000",
        "db": "NVD",
        "id": "CVE-2024-0922"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-02-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-10425"
      },
      {
        "date": "2024-02-07T04:37:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001996"
      },
      {
        "date": "2024-05-17T02:35:03.363000",
        "db": "NVD",
        "id": "CVE-2024-0922"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC10U\u00a0 Stack-based buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001996"
      }
    ],
    "trust": 0.8
  }
}

VAR-202401-1039

Vulnerability from variot - Updated: 2024-05-17 23:02

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. This issue affects the function formWifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10U is a wireless router made by China Tenda Company. The vulnerability is caused by the index parameter of the formWifiWpsOOB function failing to correctly verify the length of the input data. An attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1039",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.49_multi_tde01"
      },
      {
        "model": "ac10u",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac10u  firmware  15.03.06.49 multi tde01"
      },
      {
        "model": "ac10u 15.03.06.49 multi tde01",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13799"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002000"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0926"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0926"
      }
    ]
  },
  "cve": "CVE-2024-0926",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.4,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2024-13799",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.2,
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-0926",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2024-0926",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-0926",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-13799",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13799"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002000"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0926"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0926"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. This issue affects the function formWifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10U is a wireless router made by China Tenda Company. The vulnerability is caused by the index parameter of the formWifiWpsOOB function failing to correctly verify the length of the input data. An attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0926"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002000"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-13799"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-0926",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "252131",
        "trust": 1.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002000",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-13799",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13799"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002000"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0926"
      }
    ]
  },
  "id": "VAR-202401-1039",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13799"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13799"
      }
    ]
  },
  "last_update_date": "2024-05-17T23:02:33.337000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002000"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0926"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/yaoyue123/iot/blob/main/tenda/ac10u/formwifiwpsoob.md"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-0926"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.252131"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?id.252131"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13799"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002000"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0926"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13799"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002000"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0926"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-13799"
      },
      {
        "date": "2024-02-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-002000"
      },
      {
        "date": "2024-01-26T15:15:08.983000",
        "db": "NVD",
        "id": "CVE-2024-0926"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-13799"
      },
      {
        "date": "2024-02-07T04:38:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-002000"
      },
      {
        "date": "2024-05-17T02:35:03.880000",
        "db": "NVD",
        "id": "CVE-2024-0926"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC10U\u00a0 Stack-based buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002000"
      }
    ],
    "trust": 0.8
  }
}

VAR-202401-1105

Vulnerability from variot - Updated: 2024-05-17 22:57

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This issue affects the function setSmartPowerManagement. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10U is a wireless router from China's Tenda company. The vulnerability is caused by the setSmartPowerManagement function failing to properly check the boundaries. An attacker can exploit this vulnerability to overflow the buffer and execute arbitrary code on the system

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1105",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.49_multi_tde01"
      },
      {
        "model": "ac10u",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac10u  firmware  15.03.06.49 multi tde01"
      },
      {
        "model": "ac10u 15.03.06.49 multi tde01",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-21489"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001949"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0932"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0932"
      }
    ]
  },
  "cve": "CVE-2024-0932",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.4,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "HIGH",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "CNVD-2024-21489",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:H/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.2,
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-0932",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2024-0932",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-0932",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-21489",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-21489"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001949"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0932"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0932"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This issue affects the function setSmartPowerManagement. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10U is a wireless router from China\u0027s Tenda company. The vulnerability is caused by the setSmartPowerManagement function failing to properly check the boundaries. An attacker can exploit this vulnerability to overflow the buffer and execute arbitrary code on the system",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0932"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001949"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-21489"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-0932",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "252137",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001949",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-21489",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-21489"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001949"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0932"
      }
    ]
  },
  "id": "VAR-202401-1105",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-21489"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-21489"
      }
    ]
  },
  "last_update_date": "2024-05-17T22:57:33.329000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001949"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0932"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/yaoyue123/iot/blob/main/tenda/ac10u/setsmartpowermanagement.md"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.252137"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-0932"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.252137"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-21489"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001949"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0932"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-21489"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001949"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0932"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-05-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-21489"
      },
      {
        "date": "2024-02-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001949"
      },
      {
        "date": "2024-01-26T17:15:11.050000",
        "db": "NVD",
        "id": "CVE-2024-0932"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-05-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-21489"
      },
      {
        "date": "2024-02-07T03:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001949"
      },
      {
        "date": "2024-05-17T02:35:04.547000",
        "db": "NVD",
        "id": "CVE-2024-0932"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC10U\u00a0 Stack-based buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001949"
      }
    ],
    "trust": 0.8
  }
}

VAR-202403-0882

Vulnerability from variot - Updated: 2024-05-17 22:57

A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of ac10u The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

There is an operating system command injection vulnerability in the Tenda AC10U 15.03.06.48 version. The vulnerability is caused by the usbName parameter in the formSetSambaConf method of the /goform/setsambacfg page failing to properly filter special characters and commands in the constructed command. Attackers can exploit this vulnerability to cause arbitrary command execution

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0882",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.49"
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.48"
      },
      {
        "model": "ac10u",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac10u  firmware  15.03.06.48"
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac10u  firmware  15.03.06.49"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "15.03.06.48"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-20300"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003027"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2853"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tenda:ac10u:1.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-2853"
      }
    ]
  },
  "cve": "CVE-2024-2853",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2024-20300",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 2.8,
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-2853",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2024-2853",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-2853",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-20300",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-20300"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003027"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2853"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2853"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of ac10u The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nThere is an operating system command injection vulnerability in the Tenda AC10U 15.03.06.48 version. The vulnerability is caused by the usbName parameter in the formSetSambaConf method of the /goform/setsambacfg page failing to properly filter special characters and commands in the constructed command. Attackers can exploit this vulnerability to cause arbitrary command execution",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-2853"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003027"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-20300"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-2853",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "257777",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003027",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-20300",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-20300"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003027"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2853"
      }
    ]
  },
  "id": "VAR-202403-0882",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-20300"
      }
    ],
    "trust": 0.86649562
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-20300"
      }
    ]
  },
  "last_update_date": "2024-05-17T22:57:32.841000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC10 operating system command injection vulnerability (CNVD-2024-20300)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/541136"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-20300"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.0
      },
      {
        "problemtype": "OS Command injection (CWE-78) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003027"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2853"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac10u/v1.v15.03.06.48/more/formsetsambaconf.md"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.257777"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2853"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.257777"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-20300"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003027"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2853"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-20300"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003027"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2853"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-04-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-20300"
      },
      {
        "date": "2024-03-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-003027"
      },
      {
        "date": "2024-03-24T05:15:10.517000",
        "db": "NVD",
        "id": "CVE-2024-2853"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-04-25T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-20300"
      },
      {
        "date": "2024-03-28T00:47:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-003027"
      },
      {
        "date": "2024-05-17T02:38:34.337000",
        "db": "NVD",
        "id": "CVE-2024-2853"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac10u\u00a0 in the firmware \u00a0OS\u00a0 Command injection vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-003027"
      }
    ],
    "trust": 0.8
  }
}

VAR-202401-1131

Vulnerability from variot - Updated: 2024-05-17 22:55

A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10U is a wireless router made by the Chinese company Tenda. This vulnerability is caused by the wpapsk_crypto parameter of the fromSetWirelessRepeat function failing to correctly verify the length of the input data. An attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1131",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.49_multi_tde01"
      },
      {
        "model": "ac10u",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac10u  firmware  15.03.06.49 multi tde01"
      },
      {
        "model": "ac10u 15.03.06.49 multi tde01",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13800"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001951"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0930"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0930"
      }
    ]
  },
  "cve": "CVE-2024-0930",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.4,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2024-13800",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.2,
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-0930",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2024-0930",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-0930",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-13800",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13800"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001951"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0930"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0930"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10U is a wireless router made by the Chinese company Tenda. This vulnerability is caused by the wpapsk_crypto parameter of the fromSetWirelessRepeat function failing to correctly verify the length of the input data. An attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0930"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001951"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-13800"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-0930",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "252135",
        "trust": 1.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001951",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-13800",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13800"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001951"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0930"
      }
    ]
  },
  "id": "VAR-202401-1131",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13800"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13800"
      }
    ]
  },
  "last_update_date": "2024-05-17T22:55:38.410000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001951"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0930"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/yaoyue123/iot/blob/main/tenda/ac10u/fromsetwirelessrepeat.md"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-0930"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.252135"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?id.252135"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13800"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001951"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0930"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13800"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001951"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0930"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-13800"
      },
      {
        "date": "2024-02-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001951"
      },
      {
        "date": "2024-01-26T16:15:22.287000",
        "db": "NVD",
        "id": "CVE-2024-0930"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-13800"
      },
      {
        "date": "2024-02-07T03:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001951"
      },
      {
        "date": "2024-05-17T02:35:04.320000",
        "db": "NVD",
        "id": "CVE-2024-0930"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC10U\u00a0 Stack-based buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001951"
      }
    ],
    "trust": 0.8
  }
}

VAR-202309-1942

Vulnerability from variot - Updated: 2024-04-28 22:47

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the timeZone parameter in the fromSetSysTime function. Tenda of AC10U A buffer error vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10U is a router product running Tenda AC10U firmware. This product provides remote access, multiple network interfaces, high-speed transmission and other functions.

Tenda AC10U has a stack overflow vulnerability. An attacker can exploit this vulnerability to launch a remote attack, obtain sensitive information or execute arbitrary code, thereby causing a denial of service to the system

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202309-1942",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.49_multi_tde01"
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac10u  firmware  15.03.06.49 multi tde01"
      },
      {
        "model": "ac10u",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u us ac10uv1.0rtl v15.03.06.49 multi tde01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-20281"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-013142"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44017"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-44017"
      }
    ]
  },
  "cve": "CVE-2023-44017",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2024-20281",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-44017",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2023-44017",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-20281",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-20281"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-013142"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44017"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the timeZone parameter in the fromSetSysTime function. Tenda of AC10U A buffer error vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC10U is a router product running Tenda AC10U firmware. This product provides remote access, multiple network interfaces, high-speed transmission and other functions. \n\nTenda AC10U has a stack overflow vulnerability. An attacker can exploit this vulnerability to launch a remote attack, obtain sensitive information or execute arbitrary code, thereby causing a denial of service to the system",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-44017"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-013142"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-20281"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-44017",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-013142",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-20281",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-20281"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-013142"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44017"
      }
    ]
  },
  "id": "VAR-202309-1942",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-20281"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-20281"
      }
    ]
  },
  "last_update_date": "2024-04-28T22:47:11.583000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC10U stack overflow vulnerability (CNVD-2024-20281)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/541161"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-20281"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.0
      },
      {
        "problemtype": "Buffer error (CWE-119) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-013142"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44017"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/aixiao0621/tenda/blob/main/ac10u/6/0.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-44017"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-20281"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-013142"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44017"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-20281"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-013142"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-44017"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-04-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-20281"
      },
      {
        "date": "2023-12-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-013142"
      },
      {
        "date": "2023-09-27T15:19:35.097000",
        "db": "NVD",
        "id": "CVE-2023-44017"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-04-25T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-20281"
      },
      {
        "date": "2023-12-20T03:10:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-013142"
      },
      {
        "date": "2023-09-27T18:45:25.770000",
        "db": "NVD",
        "id": "CVE-2023-44017"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC10U\u00a0 Buffer error vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-013142"
      }
    ],
    "trust": 0.8
  }
}

VAR-202401-1038

Vulnerability from variot - Updated: 2024-03-22 23:09

A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. This vulnerability affects the function saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1038",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.49_multi_tde01"
      },
      {
        "model": "ac10u",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac10u  firmware  15.03.06.49 multi tde01"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001950"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0931"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0931"
      }
    ]
  },
  "cve": "CVE-2024-0931",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.4,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.2,
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-0931",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2024-0931",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-0931",
            "trust": 1.0,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001950"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0931"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0931"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. This vulnerability affects the function saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0931"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001950"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-0931",
        "trust": 2.6
      },
      {
        "db": "VULDB",
        "id": "252136",
        "trust": 1.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001950",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001950"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0931"
      }
    ]
  },
  "id": "VAR-202401-1038",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.75
  },
  "last_update_date": "2024-03-22T23:09:17.973000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001950"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0931"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/yaoyue123/iot/blob/main/tenda/ac10u/saveparentcontrolinfo_1.md"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.252136"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?id.252136"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-0931"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001950"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0931"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001950"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0931"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-02-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001950"
      },
      {
        "date": "2024-01-26T17:15:10.617000",
        "db": "NVD",
        "id": "CVE-2024-0931"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-02-07T03:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001950"
      },
      {
        "date": "2024-03-21T02:51:28.027000",
        "db": "NVD",
        "id": "CVE-2024-0931"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC10U\u00a0 Stack-based buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001950"
      }
    ],
    "trust": 0.8
  }
}

VAR-202401-1162

Vulnerability from variot - Updated: 2024-03-22 23:08

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been rated as critical. Affected by this issue is the function fromNatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-252134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1162",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.49_multi_tde01"
      },
      {
        "model": "ac10u",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac10u  firmware  15.03.06.49 multi tde01"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001963"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0929"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0929"
      }
    ]
  },
  "cve": "CVE-2024-0929",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.4,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "LOW",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.2,
            "impactScore": 3.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-0929",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2024-0929",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-0929",
            "trust": 1.0,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001963"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0929"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0929"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been rated as critical. Affected by this issue is the function fromNatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-252134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda of AC10U A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-0929"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001963"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-0929",
        "trust": 2.6
      },
      {
        "db": "VULDB",
        "id": "252134",
        "trust": 1.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001963",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001963"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0929"
      }
    ]
  },
  "id": "VAR-202401-1162",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.75
  },
  "last_update_date": "2024-03-22T23:08:06.008000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001963"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0929"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/yaoyue123/iot/blob/main/tenda/ac10u/fromnatstaticsetting.md"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.252134"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?id.252134"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-0929"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001963"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0929"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001963"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-0929"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-02-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001963"
      },
      {
        "date": "2024-01-26T16:15:22.020000",
        "db": "NVD",
        "id": "CVE-2024-0929"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-02-07T03:07:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-001963"
      },
      {
        "date": "2024-03-21T02:51:27.843000",
        "db": "NVD",
        "id": "CVE-2024-0929"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC10U\u00a0 Stack-based buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-001963"
      }
    ],
    "trust": 0.8
  }
}