var-202401-1132
Vulnerability from variot
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function formSetPPTPServer. The manipulation of the argument startIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of ac10u A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the startIp parameter of the formSetPPTPServer function failing to correctly verify the length of the input data. An attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1132", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac10u", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.49_multi_tde01" }, { "model": "ac10u", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac10u firmware 15.03.06.49 multi tde01" }, { "model": "ac10u", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10u", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10u 15.03.06.49 multi tde01", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-13798" }, { "db": "JVNDB", "id": "JVNDB-2024-002002" }, { "db": "NVD", "id": "CVE-2024-0924" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:ac10u:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2024-0924" } ] }, "cve": "CVE-2024-0924", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "MULTIPLE", "author": "cna@vuldb.com", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.4, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2024-13798", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "LOW", "baseScore": 4.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.2, "impactScore": 3.4, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2024-0924", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2024-0924", "trust": 1.8, "value": "CRITICAL" }, { "author": "cna@vuldb.com", "id": "CVE-2024-0924", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNVD", "id": "CNVD-2024-13798", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-13798" }, { "db": "JVNDB", "id": "JVNDB-2024-002002" }, { "db": "NVD", "id": "CVE-2024-0924" }, { "db": "NVD", "id": "CVE-2024-0924" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function formSetPPTPServer. The manipulation of the argument startIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of ac10u A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the startIp parameter of the formSetPPTPServer function failing to correctly verify the length of the input data. An attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack", "sources": [ { "db": "NVD", "id": "CVE-2024-0924" }, { "db": "JVNDB", "id": "JVNDB-2024-002002" }, { "db": "CNVD", "id": "CNVD-2024-13798" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-0924", "trust": 3.2 }, { "db": "VULDB", "id": "252129", "trust": 1.8 }, { "db": "JVNDB", "id": "JVNDB-2024-002002", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2024-13798", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-13798" }, { "db": "JVNDB", "id": "JVNDB-2024-002002" }, { "db": "NVD", "id": "CVE-2024-0924" } ] }, "id": "VAR-202401-1132", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-13798" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-13798" } ] }, "last_update_date": "2024-05-17T23:03:14.454000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 }, { "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-002002" }, { "db": "NVD", "id": "CVE-2024-0924" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/yaoyue123/iot/blob/main/tenda/ac10u/formsetpptpserver.md" }, { "trust": 1.8, "url": "https://vuldb.com/?id.252129" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-0924" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.252129" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-13798" }, { "db": "JVNDB", "id": "JVNDB-2024-002002" }, { "db": "NVD", "id": "CVE-2024-0924" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-13798" }, { "db": "JVNDB", "id": "JVNDB-2024-002002" }, { "db": "NVD", "id": "CVE-2024-0924" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-03-18T00:00:00", "db": "CNVD", "id": "CNVD-2024-13798" }, { "date": "2024-02-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2024-002002" }, { "date": "2024-01-26T15:15:08.537000", "db": "NVD", "id": "CVE-2024-0924" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-03-18T00:00:00", "db": "CNVD", "id": "CNVD-2024-13798" }, { "date": "2024-02-07T04:38:00", "db": "JVNDB", "id": "JVNDB-2024-002002" }, { "date": "2024-05-17T02:35:03.573000", "db": "NVD", "id": "CVE-2024-0924" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac10u\u00a0 Stack-based buffer overflow vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-002002" } ], "trust": 0.8 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.