cve-2024-2853
Vulnerability from cvelistv5
Published
2024-03-24 05:00
Modified
2024-08-01 19:25
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
EPSS score ?
Summary
Tenda AC10U setsambacfg formSetSambaConf os command injection
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetSambaConf.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257777 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.257777 | Third Party Advisory |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*", "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.48_multi_tde01:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10u_firmware", "vendor": "tendacn", "versions": [ { "status": "affected", "version": "15.03.06.48_multi_tde01" }, { "status": "affected", "version": "15.03.06.49_multi_tde01" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2853", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-03-25T14:19:55.063616Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-01T18:29:31.431Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.158Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257777 | Tenda AC10U setsambacfg formSetSambaConf os command injection", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257777" }, { "name": "VDB-257777 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257777" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetSambaConf.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC10U", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.48" }, { "status": "affected", "version": "15.03.06.49" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC10U 15.03.06.48/15.03.06.49 ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion formSetSambaConf der Datei /goform/setsambacfg. Durch die Manipulation des Arguments usbName mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.5, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 OS Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-24T05:00:06.892Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257777 | Tenda AC10U setsambacfg formSetSambaConf os command injection", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257777" }, { "name": "VDB-257777 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257777" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetSambaConf.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-23T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-23T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-23T06:52:17.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC10U setsambacfg formSetSambaConf os command injection" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2853", "datePublished": "2024-03-24T05:00:06.892Z", "dateReserved": "2024-03-23T05:47:14.178Z", "dateUpdated": "2024-08-01T19:25:42.158Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-2853\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2024-03-24T05:15:10.517\",\"lastModified\":\"2024-05-17T02:38:34.337\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"},{\"lang\":\"es\",\"value\":\"Se encontr\u00f3 una vulnerabilidad en Tenda AC10U 15.03.06.48/15.03.06.49. Ha sido calificada como cr\u00edtica. Este problema afecta la funci\u00f3n formSetSambaConf del archivo /goform/setsambacfg. La manipulaci\u00f3n del argumento usbName conduce a la inyecci\u00f3n de comandos del sistema operativo. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-257777. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":3.4}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":6.5},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1C2AFD04-833D-4085-BAD6-32A2715FA785\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0F101E88-BEA9-4017-9048-860DF3D1BBBC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tenda:ac10u:1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6D74EB31-E01D-439E-AAEC-BF0D4965A097\"}]}]}],\"references\":[{\"url\":\"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetSambaConf.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.257777\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\"]},{\"url\":\"https://vuldb.com/?id.257777\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.