All the vulnerabilites related to CODESYS - CODESYS Embedded Target Visu Toolkit
cve-2022-30792
Vulnerability from cvelistv5
Published
2022-07-11 10:40
Modified
2024-09-16 23:05
Summary
CODESYS: CmpChannelServer, CmpChannelServerEmbedded allow unauthenticated attackers to block all their available communication channels
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:03:38.599Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Gateway",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Windows",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Development System V3",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.10",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Runtime System Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Beckhoff CX9020 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Linux",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-07-08T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400 Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-11T10:40:43",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download="
        }
      ],
      "source": {
        "defect": [
          "CERT@VDE#",
          "64130"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "CODESYS: CmpChannelServer, CmpChannelServerEmbedded allow unauthenticated attackers to block all their available communication channels",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-07-08T06:00:00.000Z",
          "ID": "CVE-2022-30792",
          "STATE": "PUBLIC",
          "TITLE": "CODESYS: CmpChannelServer, CmpChannelServerEmbedded allow unauthenticated attackers to block all their available communication channels"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CODESYS Control RTE (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Win (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Windows",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS HMI (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Development System V3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.10"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Runtime System Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Embedded Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Remote Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for BeagleBone SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for IOT2000 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Linux SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC100 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC200 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PLCnext SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Raspberry Pi SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Linux",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CODESYS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400 Uncontrolled Resource Consumption"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=",
              "refsource": "CONFIRM",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download="
            }
          ]
        },
        "source": {
          "defect": [
            "CERT@VDE#",
            "64130"
          ],
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-30792",
    "datePublished": "2022-07-11T10:40:43.935648Z",
    "dateReserved": "2022-05-16T00:00:00",
    "dateUpdated": "2024-09-16T23:05:31.037Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-22514
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-17 03:03
Summary
Untrusted Pointer Dereference in multiple CODESYS products can lead to a DoS.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.446Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Gateway",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Windows",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Development System V3",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Runtime System Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Beckhoff CX9020 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Linux",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-04-06T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-822",
              "description": "CWE-822: Untrusted Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-27T05:55:11",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download="
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Untrusted Pointer Dereference in multiple CODESYS products can lead to a DoS.",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-04-06T10:00:00.000Z",
          "ID": "CVE-2022-22514",
          "STATE": "PUBLIC",
          "TITLE": "Untrusted Pointer Dereference in multiple CODESYS products can lead to a DoS."
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CODESYS Control RTE (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Win (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Windows",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS HMI (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Development System V3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Runtime System Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Embedded Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Remote Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for BeagleBone SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for IOT2000 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Linux SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC100 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC200 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PLCnext SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Raspberry Pi SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Linux",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CODESYS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-822: Untrusted Pointer Dereference"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download=",
              "refsource": "MISC",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download="
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-22514",
    "datePublished": "2022-04-07T18:21:14.309072Z",
    "dateReserved": "2022-01-03T00:00:00",
    "dateUpdated": "2024-09-17T03:03:50.086Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-22513
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-17 04:29
Summary
Null Pointer Dereference in multiple CODESYS products can lead to a DoS.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.460Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Gateway",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Windows",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Development System V3",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Runtime System Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Beckhoff CX9020 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Linux",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-04-06T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "CWE-476 NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-27T05:55:10",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download="
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Null Pointer Dereference in multiple CODESYS products can lead to a DoS.",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-04-06T10:00:00.000Z",
          "ID": "CVE-2022-22513",
          "STATE": "PUBLIC",
          "TITLE": "Null Pointer Dereference in multiple CODESYS products can lead to a DoS."
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CODESYS Control RTE (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Win (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Windows",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS HMI (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Development System V3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Runtime System Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Embedded Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Remote Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for BeagleBone SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for IOT2000 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Linux SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC100 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC200 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PLCnext SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Raspberry Pi SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Linux",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CODESYS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-476 NULL Pointer Dereference"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download=",
              "refsource": "MISC",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download="
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-22513",
    "datePublished": "2022-04-07T18:21:12.792321Z",
    "dateReserved": "2022-01-03T00:00:00",
    "dateUpdated": "2024-09-17T04:29:14.122Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-22517
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-16 22:16
Summary
Communication Components in multiple CODESYS products vulnerable to communication channel disruption
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.454Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Gateway",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Windows",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Development System V3",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Runtime System Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Beckhoff CX9020 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Linux",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS OPC DA Server SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS PLCHandler",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-04-06T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-334",
              "description": "CWE-334 Small Space of Random Values",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-07T18:21:19",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download="
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Communication Components in multiple CODESYS products vulnerable to communication channel disruption",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-04-06T10:00:00.000Z",
          "ID": "CVE-2022-22517",
          "STATE": "PUBLIC",
          "TITLE": "Communication Components in multiple CODESYS products vulnerable to communication channel disruption"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CODESYS Control RTE (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Win (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Windows",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS HMI (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Development System V3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Runtime System Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Embedded Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Remote Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for BeagleBone SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for IOT2000 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Linux SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC100 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC200 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PLCnext SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Raspberry Pi SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Linux",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS OPC DA Server SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS PLCHandler",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CODESYS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-334 Small Space of Random Values"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download=",
              "refsource": "MISC",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download="
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-22517",
    "datePublished": "2022-04-07T18:21:20.091353Z",
    "dateReserved": "2022-01-03T00:00:00",
    "dateUpdated": "2024-09-16T22:16:04.923Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-22519
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-17 03:22
Summary
Special HTTP(s) Requests can cause a buffer-read causing a crash of the webserver and the runtime system.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.378Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17094\u0026token=2fb188e2213c74194e81ba61ff99f1c68602ba4d\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Runtime System Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Beckhoff CX9020 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-04-06T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-126",
              "description": "CWE-126 Buffer Over-read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-27T05:55:13",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17094\u0026token=2fb188e2213c74194e81ba61ff99f1c68602ba4d\u0026download="
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Special HTTP(s) Requests can cause a buffer-read causing a crash of the webserver and the runtime system.",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-04-06T10:00:00.000Z",
          "ID": "CVE-2022-22519",
          "STATE": "PUBLIC",
          "TITLE": "Special HTTP(s) Requests can cause a buffer-read causing a crash of the webserver and the runtime system."
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CODESYS Control RTE (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Win (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS HMI (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Runtime System Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Embedded Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Remote Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for BeagleBone SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for IOT2000 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Linux SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC100 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC200 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PLCnext SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Raspberry Pi SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CODESYS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-126 Buffer Over-read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17094\u0026token=2fb188e2213c74194e81ba61ff99f1c68602ba4d\u0026download=",
              "refsource": "MISC",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17094\u0026token=2fb188e2213c74194e81ba61ff99f1c68602ba4d\u0026download="
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-22519",
    "datePublished": "2022-04-07T18:21:23.764420Z",
    "dateReserved": "2022-01-03T00:00:00",
    "dateUpdated": "2024-09-17T03:22:45.345Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-30791
Vulnerability from cvelistv5
Published
2022-07-11 10:40
Modified
2024-09-16 16:48
Summary
CODESYS V3: CmpBlkDrvTcp allows unauthenticated attackers to block all its available TCP connections
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:03:38.611Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Gateway",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Windows",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Development System V3",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.10",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Runtime System Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Beckhoff CX9020 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Linux",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-07-08T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400 Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-11T10:40:38",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download="
        }
      ],
      "source": {
        "defect": [
          "CERT@VDE#",
          "64129"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "CODESYS V3: CmpBlkDrvTcp allows unauthenticated attackers to block all its available TCP connections",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-07-08T06:00:00.000Z",
          "ID": "CVE-2022-30791",
          "STATE": "PUBLIC",
          "TITLE": "CODESYS V3: CmpBlkDrvTcp allows unauthenticated attackers to block all its available TCP connections"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CODESYS Control RTE (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Win (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Windows",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS HMI (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Development System V3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.10"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Runtime System Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Embedded Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Remote Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for BeagleBone SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for IOT2000 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Linux SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC100 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC200 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PLCnext SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Raspberry Pi SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Linux",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CODESYS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400 Uncontrolled Resource Consumption"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=",
              "refsource": "CONFIRM",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download="
            }
          ]
        },
        "source": {
          "defect": [
            "CERT@VDE#",
            "64129"
          ],
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-30791",
    "datePublished": "2022-07-11T10:40:38.913416Z",
    "dateReserved": "2022-05-16T00:00:00",
    "dateUpdated": "2024-09-16T16:48:31.565Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-8175
Vulnerability from cvelistv5
Published
2024-09-25 08:04
Modified
2024-09-25 14:02
Summary
CODESYS: web server vulnerable to DoS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "runtime_toolkit",
            "vendor": "codesys",
            "versions": [
              {
                "lessThan": "4.14.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "control_rte_\\(for_beckhoff_cx\\)_sl",
            "vendor": "codesys",
            "versions": [
              {
                "lessThan": "3.5.20.30",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:codesys:virtual_control_sl:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "virtual_control_sl",
            "vendor": "codesys",
            "versions": [
              {
                "lessThan": "4.14.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "runtime_toolkit",
            "vendor": "codesys",
            "versions": [
              {
                "lessThan": "3.5.20.30",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8175",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-25T13:44:03.391474Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-25T14:02:28.368Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for Linux ARM SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "3.5.20.30",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "3.5.20.30",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "3.5.20.30",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "3.5.20.30",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "3.5.20.30",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "3.5.20.30",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Runtime Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "3.5.20.30",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Virtual Control SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "ABB"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An unauthenticated remote attacker can\u0026nbsp;causes the CODESYS web server to access invalid memory which results in a DoS."
            }
          ],
          "value": "An unauthenticated remote attacker can\u00a0causes the CODESYS web server to access invalid memory which results in a DoS."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-25T13:33:10.408Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-057"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download="
        }
      ],
      "source": {
        "advisory": "VDE-2024-057",
        "defect": [
          "CERT@VDE#641681"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "CODESYS: web server vulnerable to DoS",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2024-8175",
    "datePublished": "2024-09-25T08:04:23.196Z",
    "dateReserved": "2024-08-26T09:58:34.794Z",
    "dateUpdated": "2024-09-25T14:02:28.368Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-22515
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-16 17:59
Summary
A component of the CODESYS Control runtime system allows read and write access to configuration files
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.437Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Development System V3",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Runtime System Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Beckhoff CX9020 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-06-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-668",
              "description": "CWE-668 Exposure of Resource to Wrong Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-12T07:45:29",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download="
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A component of the CODESYS Control runtime system allows read and write access to configuration files",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-06-01T10:00:00.000Z",
          "ID": "CVE-2022-22515",
          "STATE": "PUBLIC",
          "TITLE": "A component of the CODESYS Control runtime system allows read and write access to configuration files"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CODESYS Control RTE (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Win (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS HMI (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Development System V3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Runtime System Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Embedded Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Remote Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for BeagleBone SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for IOT2000 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Linux SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC100 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC200 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PLCnext SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Raspberry Pi SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CODESYS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-668 Exposure of Resource to Wrong Sphere"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download=",
              "refsource": "CONFIRM",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download="
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-22515",
    "datePublished": "2022-04-07T18:21:16.280553Z",
    "dateReserved": "2022-01-03T00:00:00",
    "dateUpdated": "2024-09-16T17:59:22.215Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}