Search criteria

2 vulnerabilities found for DCS-6010L by D-Link

CVE-2025-8155 (GCVE-0-2025-8155)

Vulnerability from cvelistv5 – Published: 2025-07-25 12:02 – Updated: 2025-07-25 13:24 Unsupported When Assigned
VLAI?
Title
D-Link DCS-6010L Management Application vb.htm cross site scripting
Summary
A vulnerability has been found in D-Link DCS-6010L 1.15.03 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /vb.htm of the component Management Application. The manipulation of the argument paratest leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
CWE
Assigner
References
https://vuldb.com/?id.317569 vdb-entrytechnical-description
https://vuldb.com/?ctiid.317569 signaturepermissions-required
https://vuldb.com/?submit.620531 third-party-advisory
https://www.dlink.com/ product
Impacted products
Vendor Product Version
D-Link DCS-6010L Affected: 1.15.03
Create a notification for this product.
Credits
Fergod (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8155",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-25T13:24:49.835313Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-25T13:24:58.268Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Management Application"
          ],
          "product": "DCS-6010L",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "1.15.03"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Fergod (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in D-Link DCS-6010L 1.15.03 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /vb.htm of the component Management Application. The manipulation of the argument paratest leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer."
        },
        {
          "lang": "de",
          "value": "In D-Link DCS-6010L 1.15.03 wurde eine Schwachstelle gefunden. Sie wurde als problematisch eingestuft. Hierbei betrifft es unbekannten Programmcode der Datei /vb.htm der Komponente Management Application. Durch Beeinflussen des Arguments paratest mit unbekannten Daten kann eine cross site scripting-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 4,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "Cross Site Scripting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "Code Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-25T12:02:05.610Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-317569 | D-Link DCS-6010L Management Application vb.htm cross site scripting",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.317569"
        },
        {
          "name": "VDB-317569 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.317569"
        },
        {
          "name": "Submit #620531 | D-Link DCS-6010L 1.15.03 Cross Site Scripting",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.620531"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.dlink.com/"
        }
      ],
      "tags": [
        "unsupported-when-assigned"
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-07-25T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-07-25T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-07-25T08:48:32.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link DCS-6010L Management Application vb.htm cross site scripting"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-8155",
    "datePublished": "2025-07-25T12:02:05.610Z",
    "dateReserved": "2025-07-25T06:43:19.264Z",
    "dateUpdated": "2025-07-25T13:24:58.268Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-8155 (GCVE-0-2025-8155)

Vulnerability from nvd – Published: 2025-07-25 12:02 – Updated: 2025-07-25 13:24 Unsupported When Assigned
VLAI?
Title
D-Link DCS-6010L Management Application vb.htm cross site scripting
Summary
A vulnerability has been found in D-Link DCS-6010L 1.15.03 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /vb.htm of the component Management Application. The manipulation of the argument paratest leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
CWE
Assigner
References
https://vuldb.com/?id.317569 vdb-entrytechnical-description
https://vuldb.com/?ctiid.317569 signaturepermissions-required
https://vuldb.com/?submit.620531 third-party-advisory
https://www.dlink.com/ product
Impacted products
Vendor Product Version
D-Link DCS-6010L Affected: 1.15.03
Create a notification for this product.
Credits
Fergod (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8155",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-25T13:24:49.835313Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-25T13:24:58.268Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Management Application"
          ],
          "product": "DCS-6010L",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "1.15.03"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Fergod (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in D-Link DCS-6010L 1.15.03 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /vb.htm of the component Management Application. The manipulation of the argument paratest leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer."
        },
        {
          "lang": "de",
          "value": "In D-Link DCS-6010L 1.15.03 wurde eine Schwachstelle gefunden. Sie wurde als problematisch eingestuft. Hierbei betrifft es unbekannten Programmcode der Datei /vb.htm der Komponente Management Application. Durch Beeinflussen des Arguments paratest mit unbekannten Daten kann eine cross site scripting-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 4,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "Cross Site Scripting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "Code Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-25T12:02:05.610Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-317569 | D-Link DCS-6010L Management Application vb.htm cross site scripting",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.317569"
        },
        {
          "name": "VDB-317569 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.317569"
        },
        {
          "name": "Submit #620531 | D-Link DCS-6010L 1.15.03 Cross Site Scripting",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.620531"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.dlink.com/"
        }
      ],
      "tags": [
        "unsupported-when-assigned"
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-07-25T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-07-25T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-07-25T08:48:32.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link DCS-6010L Management Application vb.htm cross site scripting"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-8155",
    "datePublished": "2025-07-25T12:02:05.610Z",
    "dateReserved": "2025-07-25T06:43:19.264Z",
    "dateUpdated": "2025-07-25T13:24:58.268Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}