All the vulnerabilites related to Schneider Electric - EcoStruxure™ Operator Terminal Expert
cve-2023-1049
Vulnerability from cvelistv5
Published
2023-06-14 07:27
Modified
2024-08-02 05:32
Severity ?
EPSS score ?
Summary
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that
could cause execution of malicious code when an unsuspicious user loads a project file from the
local filesystem into the HMI.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Schneider Electric | EcoStruxure™ Operator Terminal Expert |
Version: 3.3 SP1 and prior |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T05:32:46.335Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-164-01.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EcoStruxure\u2122 Operator Terminal Expert", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "3.3 SP1 and prior" } ] }, { "defaultStatus": "unaffected", "product": "Pro-face BLUE", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "3.3 SP1 and prior" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nA CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that\ncould cause execution of malicious code when an unsuspicious user loads a project file from the\nlocal filesystem into the HMI.\n\n" } ], "value": "\nA CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that\ncould cause execution of malicious code when an unsuspicious user loads a project file from the\nlocal filesystem into the HMI.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-94", "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-14T07:27:59.794Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-164-01.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-1049", "datePublished": "2023-06-14T07:27:59.794Z", "dateReserved": "2023-02-27T08:10:00.738Z", "dateUpdated": "2024-08-02T05:32:46.335Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }