All the vulnerabilites related to Schneider Electric - Legacy Modicon Quantum (140CPU65*)
cve-2023-25619
Vulnerability from cvelistv5
Published
2023-04-19 07:53
Modified
2024-08-02 11:25
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when communicating over the Modbus TCP protocol.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T11:25:19.427Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Modicon M340 CPU (part numbers BMXP34*) ",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "prior to SV3.51"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "prior to V4.10"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All "
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Modicon Momentum Unity M1E Processor (171CBU*)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Modicon MC80 (BMKC80)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Legacy Modicon Quantum (140CPU65*)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Legacy Modicon Premium CPUs (TSXP57*)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        }
      ],
      "datePublic": "2023-04-10T18:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when communicating over the Modbus TCP\nprotocol. \n\n"
            }
          ],
          "value": "\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when communicating over the Modbus TCP\nprotocol. \n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-12T03:15:17.732918Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2023-25619",
    "datePublished": "2023-04-19T07:53:15.405Z",
    "dateReserved": "2023-02-09T13:42:27.387Z",
    "dateUpdated": "2024-08-02T11:25:19.427Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-25620
Vulnerability from cvelistv5
Published
2023-04-19 08:17
Modified
2024-08-02 11:25
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when a malicious project file is loaded onto the controller by an authenticated user.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T11:25:19.224Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Modicon M340 CPU (part numbers BMXP34*) ",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "prior to SV3.51"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "prior to V4.10"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All "
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Modicon Momentum Unity M1E Processor (171CBU*)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Modicon MC80 (BMKC80)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Legacy Modicon Quantum (140CPU65*)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Legacy Modicon Premium CPUs (TSXP57*)",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        }
      ],
      "datePublic": "2023-04-10T18:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\n\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when a malicious project file is loaded onto the\ncontroller by an authenticated user. \n\n \n\n"
            }
          ],
          "value": "\n\n\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when a malicious project file is loaded onto the\ncontroller by an authenticated user. \n\n \n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-12T03:15:17.732918Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2023-25620",
    "datePublished": "2023-04-19T08:17:57.240Z",
    "dateReserved": "2023-02-09T13:42:27.387Z",
    "dateUpdated": "2024-08-02T11:25:19.224Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}