All the vulnerabilites related to Siemens - Mendix Applications using Mendix 9 (V9.6)
cve-2023-23835
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-02 10:42
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.34), Mendix Applications using Mendix 8 (All versions < V8.18.23), Mendix Applications using Mendix 9 (All versions < V9.22.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.10), Mendix Applications using Mendix 9 (V9.18) (All versions < V9.18.4), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.15). Some of the Mendix runtime API’s allow attackers to bypass XPath constraints and retrieve information using XPath queries that trigger errors.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T10:42:27.044Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-252808.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Mendix Applications using Mendix 7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.23.34" } ] }, { "defaultStatus": "unknown", "product": "Mendix Applications using Mendix 8", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.18.23" } ] }, { "defaultStatus": "unknown", "product": "Mendix Applications using Mendix 9", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.22.0" } ] }, { "defaultStatus": "unknown", "product": "Mendix Applications using Mendix 9 (V9.12)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.12.10" } ] }, { "defaultStatus": "unknown", "product": "Mendix Applications using Mendix 9 (V9.18)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.18.4" } ] }, { "defaultStatus": "unknown", "product": "Mendix Applications using Mendix 9 (V9.6)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.6.15" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.34), Mendix Applications using Mendix 8 (All versions \u003c V8.18.23), Mendix Applications using Mendix 9 (All versions \u003c V9.22.0), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.10), Mendix Applications using Mendix 9 (V9.18) (All versions \u003c V9.18.4), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.15). Some of the Mendix runtime API\u2019s allow attackers to bypass XPath constraints and retrieve information using XPath queries that trigger errors." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284: Improper Access Control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-15T09:24:58.910Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-252808.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-23835", "datePublished": "2023-02-14T10:36:23.615Z", "dateReserved": "2023-01-18T10:28:31.589Z", "dateUpdated": "2024-08-02T10:42:27.044Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-25650
Vulnerability from cvelistv5
Published
2022-04-12 09:07
Modified
2024-08-03 04:42
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.27), Mendix Applications using Mendix 8 (All versions < V8.18.14), Mendix Applications using Mendix 9 (All versions < V9.12.0), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.3). When querying the database, it is possible to sort the results using a protected field. With this an authenticated attacker could extract information about the contents of a protected field.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-870917.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T04:42:50.611Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-870917.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Mendix Applications using Mendix 7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.23.27" } ] }, { "product": "Mendix Applications using Mendix 8", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.18.14" } ] }, { "product": "Mendix Applications using Mendix 9", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.12.0" } ] }, { "product": "Mendix Applications using Mendix 9 (V9.6)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.6.3" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.27), Mendix Applications using Mendix 8 (All versions \u003c V8.18.14), Mendix Applications using Mendix 9 (All versions \u003c V9.12.0), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.3). When querying the database, it is possible to sort the results using a protected field. With this an authenticated attacker could extract information about the contents of a protected field." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284: Improper Access Control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-12T09:07:42", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-870917.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-25650", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Mendix Applications using Mendix 7", "version": { "version_data": [ { "version_value": "All versions \u003c V7.23.27" } ] } }, { "product_name": "Mendix Applications using Mendix 8", "version": { "version_data": [ { "version_value": "All versions \u003c V8.18.14" } ] } }, { "product_name": "Mendix Applications using Mendix 9", "version": { "version_data": [ { "version_value": "All versions \u003c V9.12.0" } ] } }, { "product_name": "Mendix Applications using Mendix 9 (V9.6)", "version": { "version_data": [ { "version_value": "All versions \u003c V9.6.3" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.27), Mendix Applications using Mendix 8 (All versions \u003c V8.18.14), Mendix Applications using Mendix 9 (All versions \u003c V9.12.0), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.3). When querying the database, it is possible to sort the results using a protected field. With this an authenticated attacker could extract information about the contents of a protected field." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-284: Improper Access Control" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-870917.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-870917.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-25650", "datePublished": "2022-04-12T09:07:42", "dateReserved": "2022-02-22T00:00:00", "dateUpdated": "2024-08-03T04:42:50.611Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-27241
Vulnerability from cvelistv5
Published
2022-04-12 09:08
Modified
2024-08-03 05:25
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T05:25:32.284Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Mendix Applications using Mendix 7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.23.31" } ] }, { "product": "Mendix Applications using Mendix 8", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.18.18" } ] }, { "product": "Mendix Applications using Mendix 9", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.11" } ] }, { "product": "Mendix Applications using Mendix 9 (V9.6)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.6.12" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-07-12T10:06:37", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-27241", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Mendix Applications using Mendix 7", "version": { "version_data": [ { "version_value": "All versions \u003c V7.23.31" } ] } }, { "product_name": "Mendix Applications using Mendix 8", "version": { "version_data": [ { "version_value": "All versions \u003c V8.18.18" } ] } }, { "product_name": "Mendix Applications using Mendix 9", "version": { "version_data": [ { "version_value": "All versions \u003c V9.11" } ] } }, { "product_name": "Mendix Applications using Mendix 9 (V9.6)", "version": { "version_data": [ { "version_value": "All versions \u003c V9.6.12" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-27241", "datePublished": "2022-04-12T09:08:00", "dateReserved": "2022-03-18T00:00:00", "dateUpdated": "2024-08-03T05:25:32.284Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-31257
Vulnerability from cvelistv5
Published
2022-07-12 10:06
Modified
2024-08-03 07:11
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). In case of access to an active user session in an application that is built with an affected version, it’s possible to change that user’s password bypassing password validations within a Mendix application. This could allow to set weak passwords.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:11:39.898Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Mendix Applications using Mendix 7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.23.31" } ] }, { "product": "Mendix Applications using Mendix 8", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.18.18" } ] }, { "product": "Mendix Applications using Mendix 9", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.14.0" } ] }, { "product": "Mendix Applications using Mendix 9 (V9.12)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.12.2" } ] }, { "product": "Mendix Applications using Mendix 9 (V9.6)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.6.12" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). In case of access to an active user session in an application that is built with an affected version, it\u2019s possible to change that user\u2019s password bypassing password validations within a Mendix application. This could allow to set weak passwords." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284: Improper Access Control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-07-12T10:06:42", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-31257", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Mendix Applications using Mendix 7", "version": { "version_data": [ { "version_value": "All versions \u003c V7.23.31" } ] } }, { "product_name": "Mendix Applications using Mendix 8", "version": { "version_data": [ { "version_value": "All versions \u003c V8.18.18" } ] } }, { "product_name": "Mendix Applications using Mendix 9", "version": { "version_data": [ { "version_value": "All versions \u003c V9.14.0" } ] } }, { "product_name": "Mendix Applications using Mendix 9 (V9.12)", "version": { "version_data": [ { "version_value": "All versions \u003c V9.12.2" } ] } }, { "product_name": "Mendix Applications using Mendix 9 (V9.6)", "version": { "version_data": [ { "version_value": "All versions \u003c V9.6.12" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). In case of access to an active user session in an application that is built with an affected version, it\u2019s possible to change that user\u2019s password bypassing password validations within a Mendix application. This could allow to set weak passwords." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-284: Improper Access Control" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-31257", "datePublished": "2022-07-12T10:06:43", "dateReserved": "2022-05-20T00:00:00", "dateUpdated": "2024-08-03T07:11:39.898Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }