CVE-2025-22475 (GCVE-0-2025-22475)

Vulnerability from cvelistv5 – Published: 2025-02-04 02:19 – Updated: 2025-02-04 16:42
VLAI?
Summary
Dell PowerProtect DD, versions prior to DDOS 8.3.0.0, 7.10.1.50, and 7.13.1.10 contains a use of a Cryptographic Primitive with a Risky Implementation vulnerability. A remote attacker could potentially exploit this vulnerability, leading to Information tampering.
CWE
  • CWE-1240 - Use of a Cryptographic Primitive with a Risky Implementation
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.7.1.0 , ≤ 8.1.0.10 (semver)
Affected: 7.13.1.0 , ≤ 7.13.1.10 (semver)
Affected: 7.10.1.0 , ≤ 7.10.1.40 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-22475",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-04T16:42:22.941168Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-04T16:42:52.826Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "8.1.0.10",
              "status": "affected",
              "version": "7.7.1.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13.1.10",
              "status": "affected",
              "version": "7.13.1.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.10.1.40",
              "status": "affected",
              "version": "7.10.1.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-01-31T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to DDOS 8.3.0.0, 7.10.1.50, and 7.13.1.10 contains a use of a Cryptographic Primitive with a Risky Implementation vulnerability. A remote attacker could potentially exploit this vulnerability, leading to Information tampering.\u003cbr\u003e"
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to DDOS 8.3.0.0, 7.10.1.50, and 7.13.1.10 contains a use of a Cryptographic Primitive with a Risky Implementation vulnerability. A remote attacker could potentially exploit this vulnerability, leading to Information tampering."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1240",
              "description": "CWE-1240: Use of a Cryptographic Primitive with a Risky Implementation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-04T02:19:38.433Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000279157/dsa-2025-022-security-update-for-dell-powerprotect-dd-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-22475",
    "datePublished": "2025-02-04T02:19:38.433Z",
    "dateReserved": "2025-01-07T06:04:12.135Z",
    "dateUpdated": "2025-02-04T16:42:52.826Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-53295 (GCVE-0-2024-53295)

Vulnerability from cvelistv5 – Published: 2025-02-01 04:12 – Updated: 2025-02-04 20:55
VLAI?
Summary
Dell PowerProtect DD versions prior to 8.3.0.0, 7.10.1.50, and 7.13.1.20 contain an improper access control vulnerability. A local malicious user with low privileges could potentially exploit this vulnerability leading to escalation of privilege.
CWE
  • CWE-1220 - Insufficient Granularity of Access Control
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.7.1.0 , ≤ 8.1.0.10 (semver)
Affected: 7.13.1.0 , ≤ 7.13.1.10 (semver)
Affected: 7.10.1.0 , ≤ 7.10.1.40 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-53295",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-04T20:54:55.330100Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-04T20:55:08.939Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "8.1.0.10",
              "status": "affected",
              "version": "7.7.1.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13.1.10",
              "status": "affected",
              "version": "7.13.1.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.10.1.40",
              "status": "affected",
              "version": "7.10.1.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-01-30T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD versions prior to 8.3.0.0, 7.10.1.50, and 7.13.1.20 contain an improper access control vulnerability. A local malicious user with low privileges could potentially exploit this vulnerability leading to escalation of privilege.\u003cbr\u003e"
            }
          ],
          "value": "Dell PowerProtect DD versions prior to 8.3.0.0, 7.10.1.50, and 7.13.1.20 contain an improper access control vulnerability. A local malicious user with low privileges could potentially exploit this vulnerability leading to escalation of privilege."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1220",
              "description": "CWE-1220: Insufficient Granularity of Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-01T04:12:10.402Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000279157/dsa-2025-022-security-update-for-dell-powerprotect-dd-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-53295",
    "datePublished": "2025-02-01T04:12:10.402Z",
    "dateReserved": "2024-11-20T06:05:04.567Z",
    "dateUpdated": "2025-02-04T20:55:08.939Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-51534 (GCVE-0-2024-51534)

Vulnerability from cvelistv5 – Published: 2025-02-01 04:02 – Updated: 2025-02-12 20:41
VLAI?
Summary
Dell PowerProtect DD versions prior to DDOS 8.3.0.0, 7.10.1.50, and 7.13.1.20 contain a path traversal vulnerability. A local low privileged could potentially exploit this vulnerability to gain unauthorized overwrite of OS files stored on the server filesystem. Exploitation could lead to denial of service.
CWE
  • CWE-29 - Path Traversal: '\..\filename'
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.7.1.0 , ≤ 8.1.0.10 (semver)
Affected: 7.7.1.0 , ≤ 7.13.1.10 (semver)
Affected: 7.7.1.0 , ≤ 7.10.1.40 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-51534",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-03T15:47:52.328743Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-12T20:41:39.859Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "8.1.0.10",
              "status": "affected",
              "version": "7.7.1.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13.1.10",
              "status": "affected",
              "version": "7.7.1.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.10.1.40",
              "status": "affected",
              "version": "7.7.1.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-01-30T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD versions prior to DDOS 8.3.0.0, 7.10.1.50, and 7.13.1.20 contain a path traversal vulnerability. A local low privileged could potentially exploit this vulnerability to gain unauthorized overwrite of OS files stored on the server filesystem. Exploitation could lead to denial of service.\u003cbr\u003e"
            }
          ],
          "value": "Dell PowerProtect DD versions prior to DDOS 8.3.0.0, 7.10.1.50, and 7.13.1.20 contain a path traversal vulnerability. A local low privileged could potentially exploit this vulnerability to gain unauthorized overwrite of OS files stored on the server filesystem. Exploitation could lead to denial of service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-29",
              "description": "CWE-29: Path Traversal: \u0027\\..\\filename\u0027",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-01T04:02:24.954Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000279157/dsa-2025-022-security-update-for-dell-powerprotect-dd-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-51534",
    "datePublished": "2025-02-01T04:02:24.954Z",
    "dateReserved": "2024-10-29T05:03:58.392Z",
    "dateUpdated": "2025-02-12T20:41:39.859Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-53296 (GCVE-0-2024-53296)

Vulnerability from cvelistv5 – Published: 2025-02-01 03:56 – Updated: 2025-02-12 20:51
VLAI?
Summary
Dell PowerProtect DD versions prior to 7.10.1.50 and 7.13.1.20 contain a Stack-based Buffer Overflow vulnerability in the RestAPI. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.13.1.0 , ≤ 7.13.1.10 (semver)
Affected: 7.10.1.0 , ≤ 7.10.1.40 (semver)
Create a notification for this product.
Credits
Dell would like to thank zzcentury for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-53296",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-03T15:48:35.858892Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-12T20:51:22.499Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13.1.10",
              "status": "affected",
              "version": "7.13.1.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.10.1.40",
              "status": "affected",
              "version": "7.10.1.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank zzcentury for reporting this issue."
        }
      ],
      "datePublic": "2025-01-30T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD versions prior to 7.10.1.50 and 7.13.1.20 contain a Stack-based Buffer Overflow vulnerability in the RestAPI. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service.\u003cbr\u003e"
            }
          ],
          "value": "Dell PowerProtect DD versions prior to 7.10.1.50 and 7.13.1.20 contain a Stack-based Buffer Overflow vulnerability in the RestAPI. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 2.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-01T03:56:38.147Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000279157/dsa-2025-022-security-update-for-dell-powerprotect-dd-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-53296",
    "datePublished": "2025-02-01T03:56:38.147Z",
    "dateReserved": "2024-11-20T06:05:04.568Z",
    "dateUpdated": "2025-02-12T20:51:22.499Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-48010 (GCVE-0-2024-48010)

Vulnerability from cvelistv5 – Published: 2024-11-08 03:01 – Updated: 2024-11-08 15:56
VLAI?
Summary
Dell PowerProtect DD, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an access control vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to escalation of privilege on the application.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.7.1 , ≤ 8.0.0.0 (semver)
Affected: N/A , < 7.13.1.10 (semver)
Affected: N/A , < 7.10.1.40 (semver)
Affected: N/A , < 7.7.5.50 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:dell:emc_data_domain_os:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:dell:apex_protection_storage:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:dell:powerprotect_data_domain:-:*:*:*:virtual:*:*:*",
              "cpe:2.3:a:dell:powerprotect_data_domain:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:dell:powerprotect_data_domain_management_center:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "powerprotect_data_domain_management_center",
            "vendor": "dell",
            "versions": [
              {
                "lessThan": "7.13.1.10",
                "status": "affected",
                "version": "7.13",
                "versionType": "semver"
              },
              {
                "lessThan": "7.10.1.40",
                "status": "affected",
                "version": "7.10",
                "versionType": "semver"
              },
              {
                "lessThan": "7.7.5.50",
                "status": "affected",
                "version": "7.7",
                "versionType": "semver"
              },
              {
                "lessThanOrEqual": "8.0.0.0",
                "status": "affected",
                "version": "7.7.1",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-48010",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-08T14:39:27.260279Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-08T15:56:27.836Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "8.0.0.0",
              "status": "affected",
              "version": "7.7.1",
              "versionType": "semver"
            },
            {
              "lessThan": "7.13.1.10",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "7.10.1.40",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "7.7.5.50",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-11-06T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an access control vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to escalation of privilege on the application."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an access control vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to escalation of privilege on the application."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-08T03:01:01.903Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000245360/dsa-2024-424-security-update-for-dell-pdsa-2024-424-security-update-for-dell-powerprotect-dd-vulnerabilityowerprotect-dd-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-48010",
    "datePublished": "2024-11-08T03:01:01.903Z",
    "dateReserved": "2024-10-08T05:40:53.868Z",
    "dateUpdated": "2024-11-08T15:56:27.836Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-45759 (GCVE-0-2024-45759)

Vulnerability from cvelistv5 – Published: 2024-11-08 02:48 – Updated: 2024-11-08 15:56
VLAI?
Summary
Dell PowerProtect Data Domain, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an escalation of privilege vulnerability. A local low privileged attacker could potentially exploit this vulnerability, leading to unauthorized execution of certain commands to overwrite system config of the application. Exploitation may lead to denial of service of system.
CWE
  • CWE-266 - Incorrect Privilege Assignment
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.7.1 , ≤ 8.0.0.0 (semver)
Affected: N/A , < 7.13.1.10 (semver)
Affected: N/A , < 7.10.1.40 (semver)
Affected: N/A , < 7.7.5.50 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-45759",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-08T15:56:43.217523Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-08T15:56:51.934Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "8.0.0.0",
              "status": "affected",
              "version": "7.7.1",
              "versionType": "semver"
            },
            {
              "lessThan": "7.13.1.10",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "7.10.1.40",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "7.7.5.50",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-11-06T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Domain, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an escalation of privilege vulnerability. A local low privileged attacker could potentially exploit this vulnerability, leading to unauthorized execution of certain commands to overwrite system config of the application. Exploitation may lead to denial of service of system."
            }
          ],
          "value": "Dell PowerProtect Data Domain, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an escalation of privilege vulnerability. A local low privileged attacker could potentially exploit this vulnerability, leading to unauthorized execution of certain commands to overwrite system config of the application. Exploitation may lead to denial of service of system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-266",
              "description": "CWE-266: Incorrect Privilege Assignment",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-08T02:49:40.726Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000245360/dsa-2024-424-security-update-for-dell-pdsa-2024-424-security-update-for-dell-powerprotect-dd-vulnerabilityowerprotect-dd-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-45759",
    "datePublished": "2024-11-08T02:48:42.259Z",
    "dateReserved": "2024-09-06T06:30:30.480Z",
    "dateUpdated": "2024-11-08T15:56:51.934Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-48011 (GCVE-0-2024-48011)

Vulnerability from cvelistv5 – Published: 2024-11-08 02:30 – Updated: 2024-11-08 15:57
VLAI?
Summary
Dell PowerProtect DD, versions prior to 7.7.5.50, contains an Exposure of Sensitive Information to an Unauthorized Actor vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.
CWE
  • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: N/A , < 7.7.5.50 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-48011",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-08T15:57:03.582740Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-08T15:57:13.659Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "7.7.5.50",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-11-06T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 7.7.5.50, contains an Exposure of Sensitive Information to an Unauthorized Actor vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 7.7.5.50, contains an Exposure of Sensitive Information to an Unauthorized Actor vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.1,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-08T02:30:27.068Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000245360/dsa-2024-424-security-update-for-dell-pdsa-2024-424-security-update-for-dell-powerprotect-dd-vulnerabilityowerprotect-dd-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-48011",
    "datePublished": "2024-11-08T02:30:27.068Z",
    "dateReserved": "2024-10-08T05:40:53.868Z",
    "dateUpdated": "2024-11-08T15:57:13.659Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37141 (GCVE-0-2024-37141)

Vulnerability from cvelistv5 – Published: 2024-06-26 04:00 – Updated: 2024-08-02 03:50
VLAI?
Summary
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an open redirect vulnerability. A remote low privileged attacker could potentially exploit this vulnerability, leading to information disclosure.
CWE
  • CWE-601 - URL Redirection to Untrusted Site ('Open Redirect')
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.0 , ≤ 7.13 (semver)
Affected: N/A , < 2.7.7 (semver)
Affected: N/A , < 5.16.0.0 (semver)
Affected: 7.8 , ≤ 7.13 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37141",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T13:51:27.416210Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T13:51:36.659Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:50:54.576Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            },
            {
              "lessThan": "2.7.7",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "5.16.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.8",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an open redirect vulnerability. A remote low privileged attacker could potentially exploit this vulnerability, leading to information disclosure."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an open redirect vulnerability. A remote low privileged attacker could potentially exploit this vulnerability, leading to information disclosure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-601",
              "description": "CWE-601: URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T04:00:34.863Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-37141",
    "datePublished": "2024-06-26T04:00:34.863Z",
    "dateReserved": "2024-06-03T12:10:32.206Z",
    "dateUpdated": "2024-08-02T03:50:54.576Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37140 (GCVE-0-2024-37140)

Vulnerability from cvelistv5 – Published: 2024-06-26 03:54 – Updated: 2024-08-02 03:50
VLAI?
Summary
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an OS command injection vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the system application's underlying OS with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.0 , ≤ 7.13 (semver)
Affected: N/A , < 2.7.7 (semver)
Affected: N/A , < 5.16.0.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:dell:powerprotect_dd:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "powerprotect_dd",
            "vendor": "dell",
            "versions": [
              {
                "lessThanOrEqual": "7.13",
                "status": "affected",
                "version": "7.0",
                "versionType": "semver"
              },
              {
                "lessThan": "2.7.7",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              },
              {
                "lessThan": "5.16.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37140",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T14:38:33.257609Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T14:49:39.900Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:50:54.530Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            },
            {
              "lessThan": "2.7.7",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "5.16.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an OS command injection vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the system application\u0027s underlying OS with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an OS command injection vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the system application\u0027s underlying OS with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T03:54:38.461Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-37140",
    "datePublished": "2024-06-26T03:54:38.461Z",
    "dateReserved": "2024-06-03T12:10:32.206Z",
    "dateUpdated": "2024-08-02T03:50:54.530Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37139 (GCVE-0-2024-37139)

Vulnerability from cvelistv5 – Published: 2024-06-26 03:38 – Updated: 2024-08-02 03:50
VLAI?
Summary
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an Improper Control of a Resource Through its Lifetime vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to temporary resource constraint of system application. Exploitation may lead to denial of service of the application.
CWE
  • CWE-664 - Improper Control of a Resource Through its Lifetime
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: N/A , < 5.16.0.0 (semver)
Affected: N/A , < 2.7.7 (semver)
Affected: 7.0 , ≤ 7.13 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37139",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T13:19:16.878748Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T13:19:29.262Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:50:55.487Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.16.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.7.7",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an Improper Control of a Resource Through its Lifetime vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to temporary resource constraint of system application. Exploitation may lead to denial of service of the application."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an Improper Control of a Resource Through its Lifetime vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to temporary resource constraint of system application. Exploitation may lead to denial of service of the application."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-664",
              "description": "CWE-664: Improper Control of a Resource Through its Lifetime",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T03:38:45.473Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-37139",
    "datePublished": "2024-06-26T03:38:45.473Z",
    "dateReserved": "2024-06-03T12:10:32.206Z",
    "dateUpdated": "2024-08-02T03:50:55.487Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37138 (GCVE-0-2024-37138)

Vulnerability from cvelistv5 – Published: 2024-06-26 03:24 – Updated: 2024-08-02 03:50
VLAI?
Summary
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 on DDMC contain a relative path traversal vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the application sending over an unauthorized file to the managed system.
CWE
  • CWE-23 - Relative Path Traversal
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.0 , ≤ 7.13 (semver)
Affected: 7.8 , ≤ 7.13 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37138",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T17:35:32.470798Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T17:42:52.419Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:50:55.311Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.8",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 on DDMC contain a relative path traversal vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the application sending over an unauthorized file to the managed system."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 on DDMC contain a relative path traversal vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the application sending over an unauthorized file to the managed system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-23",
              "description": "CWE-23: Relative Path Traversal",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T03:24:40.504Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-37138",
    "datePublished": "2024-06-26T03:24:40.504Z",
    "dateReserved": "2024-06-03T12:10:32.206Z",
    "dateUpdated": "2024-08-02T03:50:55.311Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-29175 (GCVE-0-2024-29175)

Vulnerability from cvelistv5 – Published: 2024-06-26 03:03 – Updated: 2024-08-02 01:10
VLAI?
Summary
Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information.
CWE
  • CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.0 , ≤ 7.13 (semver)
Affected: N/A , < 2.7.7 (semver)
Affected: N/A , < 5.16.0.0 (semver)
Affected: 7.8 , ≤ 7.13 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:dell:powerprotect_dd:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "powerprotect_dd",
            "vendor": "dell",
            "versions": [
              {
                "lessThanOrEqual": "7.13",
                "status": "affected",
                "version": "7.0",
                "versionType": "semver"
              },
              {
                "lessThan": "2.7.7",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              },
              {
                "lessThan": "5.16.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              },
              {
                "lessThanOrEqual": "7.13",
                "status": "affected",
                "version": "7.8",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29175",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-11T15:11:41.076013Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-11T15:17:48.750Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:10:54.627Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            },
            {
              "lessThan": "2.7.7",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "5.16.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.8",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information."
            }
          ],
          "value": "Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-327",
              "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T03:03:06.155Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-29175",
    "datePublished": "2024-06-26T03:03:06.155Z",
    "dateReserved": "2024-03-18T08:44:18.923Z",
    "dateUpdated": "2024-08-02T01:10:54.627Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-29174 (GCVE-0-2024-29174)

Vulnerability from cvelistv5 – Published: 2024-06-26 02:57 – Updated: 2024-08-02 01:10
VLAI?
Summary
Dell Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.30, LTS 7.10.1.20 contain an SQL Injection vulnerability. A local low privileged attacker could potentially exploit this vulnerability, leading to the execution of certain SQL commands on the application's backend database causing unauthorized access to application data.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.0 , ≤ 7.13 (semver)
Affected: 7.8 , ≤ 7.13 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29174",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T13:31:50.817888Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T13:31:57.460Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:10:54.083Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.8",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.30, LTS 7.10.1.20 contain an SQL Injection vulnerability. A local low privileged attacker could potentially exploit this vulnerability, leading to the execution of certain SQL commands on the application\u0027s backend database causing unauthorized access to application data."
            }
          ],
          "value": "Dell Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.30, LTS 7.10.1.20 contain an SQL Injection vulnerability. A local low privileged attacker could potentially exploit this vulnerability, leading to the execution of certain SQL commands on the application\u0027s backend database causing unauthorized access to application data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T02:57:41.758Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-29174",
    "datePublished": "2024-06-26T02:57:41.758Z",
    "dateReserved": "2024-03-18T08:44:18.923Z",
    "dateUpdated": "2024-08-02T01:10:54.083Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-29173 (GCVE-0-2024-29173)

Vulnerability from cvelistv5 – Published: 2024-06-26 02:51 – Updated: 2024-08-02 01:10
VLAI?
Summary
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a Server-Side Request Forgery (SSRF) vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to disclosure of information on the application or remote client.
CWE
  • CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.0 , ≤ 7.13 (semver)
Affected: N/A , < 2.7.7 (semver)
Affected: N/A , < 5.16.0.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29173",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T13:51:50.695281Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T13:51:57.600Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:10:54.471Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            },
            {
              "lessThan": "2.7.7",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "5.16.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a Server-Side Request Forgery (SSRF) vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to disclosure of information on the application or remote client."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a Server-Side Request Forgery (SSRF) vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to disclosure of information on the application or remote client."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-918",
              "description": "CWE-918: Server-Side Request Forgery (SSRF)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T02:51:56.989Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-29173",
    "datePublished": "2024-06-26T02:51:56.989Z",
    "dateReserved": "2024-03-18T08:44:18.923Z",
    "dateUpdated": "2024-08-02T01:10:54.471Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-29177 (GCVE-0-2024-29177)

Vulnerability from cvelistv5 – Published: 2024-06-26 02:46 – Updated: 2024-08-02 01:10
VLAI?
Summary
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report.
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.0 , ≤ 7.13 (semver)
Affected: N/A , < 2.7.7 (semver)
Affected: N/A , < 5.16.0.0 (semver)
Affected: 7.8 , ≤ 7.13 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29177",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T19:05:17.020326Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T19:05:23.225Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:10:54.086Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            },
            {
              "lessThan": "2.7.7",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "5.16.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.8",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 2.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T02:46:55.073Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-29177",
    "datePublished": "2024-06-26T02:46:55.073Z",
    "dateReserved": "2024-03-18T08:44:18.924Z",
    "dateUpdated": "2024-08-02T01:10:54.086Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-22475 (GCVE-0-2025-22475)

Vulnerability from nvd – Published: 2025-02-04 02:19 – Updated: 2025-02-04 16:42
VLAI?
Summary
Dell PowerProtect DD, versions prior to DDOS 8.3.0.0, 7.10.1.50, and 7.13.1.10 contains a use of a Cryptographic Primitive with a Risky Implementation vulnerability. A remote attacker could potentially exploit this vulnerability, leading to Information tampering.
CWE
  • CWE-1240 - Use of a Cryptographic Primitive with a Risky Implementation
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.7.1.0 , ≤ 8.1.0.10 (semver)
Affected: 7.13.1.0 , ≤ 7.13.1.10 (semver)
Affected: 7.10.1.0 , ≤ 7.10.1.40 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-22475",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-04T16:42:22.941168Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-04T16:42:52.826Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "8.1.0.10",
              "status": "affected",
              "version": "7.7.1.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13.1.10",
              "status": "affected",
              "version": "7.13.1.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.10.1.40",
              "status": "affected",
              "version": "7.10.1.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-01-31T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to DDOS 8.3.0.0, 7.10.1.50, and 7.13.1.10 contains a use of a Cryptographic Primitive with a Risky Implementation vulnerability. A remote attacker could potentially exploit this vulnerability, leading to Information tampering.\u003cbr\u003e"
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to DDOS 8.3.0.0, 7.10.1.50, and 7.13.1.10 contains a use of a Cryptographic Primitive with a Risky Implementation vulnerability. A remote attacker could potentially exploit this vulnerability, leading to Information tampering."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1240",
              "description": "CWE-1240: Use of a Cryptographic Primitive with a Risky Implementation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-04T02:19:38.433Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000279157/dsa-2025-022-security-update-for-dell-powerprotect-dd-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-22475",
    "datePublished": "2025-02-04T02:19:38.433Z",
    "dateReserved": "2025-01-07T06:04:12.135Z",
    "dateUpdated": "2025-02-04T16:42:52.826Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-53295 (GCVE-0-2024-53295)

Vulnerability from nvd – Published: 2025-02-01 04:12 – Updated: 2025-02-04 20:55
VLAI?
Summary
Dell PowerProtect DD versions prior to 8.3.0.0, 7.10.1.50, and 7.13.1.20 contain an improper access control vulnerability. A local malicious user with low privileges could potentially exploit this vulnerability leading to escalation of privilege.
CWE
  • CWE-1220 - Insufficient Granularity of Access Control
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.7.1.0 , ≤ 8.1.0.10 (semver)
Affected: 7.13.1.0 , ≤ 7.13.1.10 (semver)
Affected: 7.10.1.0 , ≤ 7.10.1.40 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-53295",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-04T20:54:55.330100Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-04T20:55:08.939Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "8.1.0.10",
              "status": "affected",
              "version": "7.7.1.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13.1.10",
              "status": "affected",
              "version": "7.13.1.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.10.1.40",
              "status": "affected",
              "version": "7.10.1.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-01-30T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD versions prior to 8.3.0.0, 7.10.1.50, and 7.13.1.20 contain an improper access control vulnerability. A local malicious user with low privileges could potentially exploit this vulnerability leading to escalation of privilege.\u003cbr\u003e"
            }
          ],
          "value": "Dell PowerProtect DD versions prior to 8.3.0.0, 7.10.1.50, and 7.13.1.20 contain an improper access control vulnerability. A local malicious user with low privileges could potentially exploit this vulnerability leading to escalation of privilege."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1220",
              "description": "CWE-1220: Insufficient Granularity of Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-01T04:12:10.402Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000279157/dsa-2025-022-security-update-for-dell-powerprotect-dd-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-53295",
    "datePublished": "2025-02-01T04:12:10.402Z",
    "dateReserved": "2024-11-20T06:05:04.567Z",
    "dateUpdated": "2025-02-04T20:55:08.939Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-51534 (GCVE-0-2024-51534)

Vulnerability from nvd – Published: 2025-02-01 04:02 – Updated: 2025-02-12 20:41
VLAI?
Summary
Dell PowerProtect DD versions prior to DDOS 8.3.0.0, 7.10.1.50, and 7.13.1.20 contain a path traversal vulnerability. A local low privileged could potentially exploit this vulnerability to gain unauthorized overwrite of OS files stored on the server filesystem. Exploitation could lead to denial of service.
CWE
  • CWE-29 - Path Traversal: '\..\filename'
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.7.1.0 , ≤ 8.1.0.10 (semver)
Affected: 7.7.1.0 , ≤ 7.13.1.10 (semver)
Affected: 7.7.1.0 , ≤ 7.10.1.40 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-51534",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-03T15:47:52.328743Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-12T20:41:39.859Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "8.1.0.10",
              "status": "affected",
              "version": "7.7.1.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13.1.10",
              "status": "affected",
              "version": "7.7.1.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.10.1.40",
              "status": "affected",
              "version": "7.7.1.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-01-30T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD versions prior to DDOS 8.3.0.0, 7.10.1.50, and 7.13.1.20 contain a path traversal vulnerability. A local low privileged could potentially exploit this vulnerability to gain unauthorized overwrite of OS files stored on the server filesystem. Exploitation could lead to denial of service.\u003cbr\u003e"
            }
          ],
          "value": "Dell PowerProtect DD versions prior to DDOS 8.3.0.0, 7.10.1.50, and 7.13.1.20 contain a path traversal vulnerability. A local low privileged could potentially exploit this vulnerability to gain unauthorized overwrite of OS files stored on the server filesystem. Exploitation could lead to denial of service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-29",
              "description": "CWE-29: Path Traversal: \u0027\\..\\filename\u0027",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-01T04:02:24.954Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000279157/dsa-2025-022-security-update-for-dell-powerprotect-dd-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-51534",
    "datePublished": "2025-02-01T04:02:24.954Z",
    "dateReserved": "2024-10-29T05:03:58.392Z",
    "dateUpdated": "2025-02-12T20:41:39.859Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-53296 (GCVE-0-2024-53296)

Vulnerability from nvd – Published: 2025-02-01 03:56 – Updated: 2025-02-12 20:51
VLAI?
Summary
Dell PowerProtect DD versions prior to 7.10.1.50 and 7.13.1.20 contain a Stack-based Buffer Overflow vulnerability in the RestAPI. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.13.1.0 , ≤ 7.13.1.10 (semver)
Affected: 7.10.1.0 , ≤ 7.10.1.40 (semver)
Create a notification for this product.
Credits
Dell would like to thank zzcentury for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-53296",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-03T15:48:35.858892Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-12T20:51:22.499Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13.1.10",
              "status": "affected",
              "version": "7.13.1.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.10.1.40",
              "status": "affected",
              "version": "7.10.1.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank zzcentury for reporting this issue."
        }
      ],
      "datePublic": "2025-01-30T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD versions prior to 7.10.1.50 and 7.13.1.20 contain a Stack-based Buffer Overflow vulnerability in the RestAPI. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service.\u003cbr\u003e"
            }
          ],
          "value": "Dell PowerProtect DD versions prior to 7.10.1.50 and 7.13.1.20 contain a Stack-based Buffer Overflow vulnerability in the RestAPI. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 2.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-01T03:56:38.147Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000279157/dsa-2025-022-security-update-for-dell-powerprotect-dd-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-53296",
    "datePublished": "2025-02-01T03:56:38.147Z",
    "dateReserved": "2024-11-20T06:05:04.568Z",
    "dateUpdated": "2025-02-12T20:51:22.499Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-48010 (GCVE-0-2024-48010)

Vulnerability from nvd – Published: 2024-11-08 03:01 – Updated: 2024-11-08 15:56
VLAI?
Summary
Dell PowerProtect DD, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an access control vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to escalation of privilege on the application.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.7.1 , ≤ 8.0.0.0 (semver)
Affected: N/A , < 7.13.1.10 (semver)
Affected: N/A , < 7.10.1.40 (semver)
Affected: N/A , < 7.7.5.50 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:dell:emc_data_domain_os:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:dell:apex_protection_storage:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:dell:powerprotect_data_domain:-:*:*:*:virtual:*:*:*",
              "cpe:2.3:a:dell:powerprotect_data_domain:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:dell:powerprotect_data_domain_management_center:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "powerprotect_data_domain_management_center",
            "vendor": "dell",
            "versions": [
              {
                "lessThan": "7.13.1.10",
                "status": "affected",
                "version": "7.13",
                "versionType": "semver"
              },
              {
                "lessThan": "7.10.1.40",
                "status": "affected",
                "version": "7.10",
                "versionType": "semver"
              },
              {
                "lessThan": "7.7.5.50",
                "status": "affected",
                "version": "7.7",
                "versionType": "semver"
              },
              {
                "lessThanOrEqual": "8.0.0.0",
                "status": "affected",
                "version": "7.7.1",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-48010",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-08T14:39:27.260279Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-08T15:56:27.836Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "8.0.0.0",
              "status": "affected",
              "version": "7.7.1",
              "versionType": "semver"
            },
            {
              "lessThan": "7.13.1.10",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "7.10.1.40",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "7.7.5.50",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-11-06T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an access control vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to escalation of privilege on the application."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an access control vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to escalation of privilege on the application."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-08T03:01:01.903Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000245360/dsa-2024-424-security-update-for-dell-pdsa-2024-424-security-update-for-dell-powerprotect-dd-vulnerabilityowerprotect-dd-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-48010",
    "datePublished": "2024-11-08T03:01:01.903Z",
    "dateReserved": "2024-10-08T05:40:53.868Z",
    "dateUpdated": "2024-11-08T15:56:27.836Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-45759 (GCVE-0-2024-45759)

Vulnerability from nvd – Published: 2024-11-08 02:48 – Updated: 2024-11-08 15:56
VLAI?
Summary
Dell PowerProtect Data Domain, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an escalation of privilege vulnerability. A local low privileged attacker could potentially exploit this vulnerability, leading to unauthorized execution of certain commands to overwrite system config of the application. Exploitation may lead to denial of service of system.
CWE
  • CWE-266 - Incorrect Privilege Assignment
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.7.1 , ≤ 8.0.0.0 (semver)
Affected: N/A , < 7.13.1.10 (semver)
Affected: N/A , < 7.10.1.40 (semver)
Affected: N/A , < 7.7.5.50 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-45759",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-08T15:56:43.217523Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-08T15:56:51.934Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "8.0.0.0",
              "status": "affected",
              "version": "7.7.1",
              "versionType": "semver"
            },
            {
              "lessThan": "7.13.1.10",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "7.10.1.40",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "7.7.5.50",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-11-06T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Domain, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an escalation of privilege vulnerability. A local low privileged attacker could potentially exploit this vulnerability, leading to unauthorized execution of certain commands to overwrite system config of the application. Exploitation may lead to denial of service of system."
            }
          ],
          "value": "Dell PowerProtect Data Domain, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an escalation of privilege vulnerability. A local low privileged attacker could potentially exploit this vulnerability, leading to unauthorized execution of certain commands to overwrite system config of the application. Exploitation may lead to denial of service of system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-266",
              "description": "CWE-266: Incorrect Privilege Assignment",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-08T02:49:40.726Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000245360/dsa-2024-424-security-update-for-dell-pdsa-2024-424-security-update-for-dell-powerprotect-dd-vulnerabilityowerprotect-dd-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-45759",
    "datePublished": "2024-11-08T02:48:42.259Z",
    "dateReserved": "2024-09-06T06:30:30.480Z",
    "dateUpdated": "2024-11-08T15:56:51.934Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-48011 (GCVE-0-2024-48011)

Vulnerability from nvd – Published: 2024-11-08 02:30 – Updated: 2024-11-08 15:57
VLAI?
Summary
Dell PowerProtect DD, versions prior to 7.7.5.50, contains an Exposure of Sensitive Information to an Unauthorized Actor vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.
CWE
  • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: N/A , < 7.7.5.50 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-48011",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-08T15:57:03.582740Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-08T15:57:13.659Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "7.7.5.50",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-11-06T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 7.7.5.50, contains an Exposure of Sensitive Information to an Unauthorized Actor vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 7.7.5.50, contains an Exposure of Sensitive Information to an Unauthorized Actor vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.1,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-08T02:30:27.068Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000245360/dsa-2024-424-security-update-for-dell-pdsa-2024-424-security-update-for-dell-powerprotect-dd-vulnerabilityowerprotect-dd-vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-48011",
    "datePublished": "2024-11-08T02:30:27.068Z",
    "dateReserved": "2024-10-08T05:40:53.868Z",
    "dateUpdated": "2024-11-08T15:57:13.659Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37141 (GCVE-0-2024-37141)

Vulnerability from nvd – Published: 2024-06-26 04:00 – Updated: 2024-08-02 03:50
VLAI?
Summary
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an open redirect vulnerability. A remote low privileged attacker could potentially exploit this vulnerability, leading to information disclosure.
CWE
  • CWE-601 - URL Redirection to Untrusted Site ('Open Redirect')
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.0 , ≤ 7.13 (semver)
Affected: N/A , < 2.7.7 (semver)
Affected: N/A , < 5.16.0.0 (semver)
Affected: 7.8 , ≤ 7.13 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37141",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T13:51:27.416210Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T13:51:36.659Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:50:54.576Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            },
            {
              "lessThan": "2.7.7",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "5.16.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.8",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an open redirect vulnerability. A remote low privileged attacker could potentially exploit this vulnerability, leading to information disclosure."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an open redirect vulnerability. A remote low privileged attacker could potentially exploit this vulnerability, leading to information disclosure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-601",
              "description": "CWE-601: URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T04:00:34.863Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-37141",
    "datePublished": "2024-06-26T04:00:34.863Z",
    "dateReserved": "2024-06-03T12:10:32.206Z",
    "dateUpdated": "2024-08-02T03:50:54.576Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37140 (GCVE-0-2024-37140)

Vulnerability from nvd – Published: 2024-06-26 03:54 – Updated: 2024-08-02 03:50
VLAI?
Summary
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an OS command injection vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the system application's underlying OS with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.0 , ≤ 7.13 (semver)
Affected: N/A , < 2.7.7 (semver)
Affected: N/A , < 5.16.0.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:dell:powerprotect_dd:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "powerprotect_dd",
            "vendor": "dell",
            "versions": [
              {
                "lessThanOrEqual": "7.13",
                "status": "affected",
                "version": "7.0",
                "versionType": "semver"
              },
              {
                "lessThan": "2.7.7",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              },
              {
                "lessThan": "5.16.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37140",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T14:38:33.257609Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T14:49:39.900Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:50:54.530Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            },
            {
              "lessThan": "2.7.7",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "5.16.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an OS command injection vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the system application\u0027s underlying OS with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an OS command injection vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the system application\u0027s underlying OS with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T03:54:38.461Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-37140",
    "datePublished": "2024-06-26T03:54:38.461Z",
    "dateReserved": "2024-06-03T12:10:32.206Z",
    "dateUpdated": "2024-08-02T03:50:54.530Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37139 (GCVE-0-2024-37139)

Vulnerability from nvd – Published: 2024-06-26 03:38 – Updated: 2024-08-02 03:50
VLAI?
Summary
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an Improper Control of a Resource Through its Lifetime vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to temporary resource constraint of system application. Exploitation may lead to denial of service of the application.
CWE
  • CWE-664 - Improper Control of a Resource Through its Lifetime
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: N/A , < 5.16.0.0 (semver)
Affected: N/A , < 2.7.7 (semver)
Affected: 7.0 , ≤ 7.13 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37139",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T13:19:16.878748Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T13:19:29.262Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:50:55.487Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.16.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.7.7",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an Improper Control of a Resource Through its Lifetime vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to temporary resource constraint of system application. Exploitation may lead to denial of service of the application."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an Improper Control of a Resource Through its Lifetime vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to temporary resource constraint of system application. Exploitation may lead to denial of service of the application."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-664",
              "description": "CWE-664: Improper Control of a Resource Through its Lifetime",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T03:38:45.473Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-37139",
    "datePublished": "2024-06-26T03:38:45.473Z",
    "dateReserved": "2024-06-03T12:10:32.206Z",
    "dateUpdated": "2024-08-02T03:50:55.487Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37138 (GCVE-0-2024-37138)

Vulnerability from nvd – Published: 2024-06-26 03:24 – Updated: 2024-08-02 03:50
VLAI?
Summary
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 on DDMC contain a relative path traversal vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the application sending over an unauthorized file to the managed system.
CWE
  • CWE-23 - Relative Path Traversal
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.0 , ≤ 7.13 (semver)
Affected: 7.8 , ≤ 7.13 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37138",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T17:35:32.470798Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T17:42:52.419Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:50:55.311Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.8",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 on DDMC contain a relative path traversal vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the application sending over an unauthorized file to the managed system."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 on DDMC contain a relative path traversal vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the application sending over an unauthorized file to the managed system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-23",
              "description": "CWE-23: Relative Path Traversal",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T03:24:40.504Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-37138",
    "datePublished": "2024-06-26T03:24:40.504Z",
    "dateReserved": "2024-06-03T12:10:32.206Z",
    "dateUpdated": "2024-08-02T03:50:55.311Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-29175 (GCVE-0-2024-29175)

Vulnerability from nvd – Published: 2024-06-26 03:03 – Updated: 2024-08-02 01:10
VLAI?
Summary
Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information.
CWE
  • CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.0 , ≤ 7.13 (semver)
Affected: N/A , < 2.7.7 (semver)
Affected: N/A , < 5.16.0.0 (semver)
Affected: 7.8 , ≤ 7.13 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:dell:powerprotect_dd:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "powerprotect_dd",
            "vendor": "dell",
            "versions": [
              {
                "lessThanOrEqual": "7.13",
                "status": "affected",
                "version": "7.0",
                "versionType": "semver"
              },
              {
                "lessThan": "2.7.7",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              },
              {
                "lessThan": "5.16.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              },
              {
                "lessThanOrEqual": "7.13",
                "status": "affected",
                "version": "7.8",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29175",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-11T15:11:41.076013Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-11T15:17:48.750Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:10:54.627Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            },
            {
              "lessThan": "2.7.7",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "5.16.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.8",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information."
            }
          ],
          "value": "Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-327",
              "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T03:03:06.155Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-29175",
    "datePublished": "2024-06-26T03:03:06.155Z",
    "dateReserved": "2024-03-18T08:44:18.923Z",
    "dateUpdated": "2024-08-02T01:10:54.627Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-29174 (GCVE-0-2024-29174)

Vulnerability from nvd – Published: 2024-06-26 02:57 – Updated: 2024-08-02 01:10
VLAI?
Summary
Dell Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.30, LTS 7.10.1.20 contain an SQL Injection vulnerability. A local low privileged attacker could potentially exploit this vulnerability, leading to the execution of certain SQL commands on the application's backend database causing unauthorized access to application data.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.0 , ≤ 7.13 (semver)
Affected: 7.8 , ≤ 7.13 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29174",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T13:31:50.817888Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T13:31:57.460Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:10:54.083Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.8",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.30, LTS 7.10.1.20 contain an SQL Injection vulnerability. A local low privileged attacker could potentially exploit this vulnerability, leading to the execution of certain SQL commands on the application\u0027s backend database causing unauthorized access to application data."
            }
          ],
          "value": "Dell Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.30, LTS 7.10.1.20 contain an SQL Injection vulnerability. A local low privileged attacker could potentially exploit this vulnerability, leading to the execution of certain SQL commands on the application\u0027s backend database causing unauthorized access to application data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T02:57:41.758Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-29174",
    "datePublished": "2024-06-26T02:57:41.758Z",
    "dateReserved": "2024-03-18T08:44:18.923Z",
    "dateUpdated": "2024-08-02T01:10:54.083Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-29173 (GCVE-0-2024-29173)

Vulnerability from nvd – Published: 2024-06-26 02:51 – Updated: 2024-08-02 01:10
VLAI?
Summary
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a Server-Side Request Forgery (SSRF) vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to disclosure of information on the application or remote client.
CWE
  • CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.0 , ≤ 7.13 (semver)
Affected: N/A , < 2.7.7 (semver)
Affected: N/A , < 5.16.0.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29173",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T13:51:50.695281Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T13:51:57.600Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:10:54.471Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            },
            {
              "lessThan": "2.7.7",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "5.16.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a Server-Side Request Forgery (SSRF) vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to disclosure of information on the application or remote client."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a Server-Side Request Forgery (SSRF) vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to disclosure of information on the application or remote client."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-918",
              "description": "CWE-918: Server-Side Request Forgery (SSRF)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T02:51:56.989Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-29173",
    "datePublished": "2024-06-26T02:51:56.989Z",
    "dateReserved": "2024-03-18T08:44:18.923Z",
    "dateUpdated": "2024-08-02T01:10:54.471Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-29177 (GCVE-0-2024-29177)

Vulnerability from nvd – Published: 2024-06-26 02:46 – Updated: 2024-08-02 01:10
VLAI?
Summary
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report.
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect DD Affected: 7.0 , ≤ 7.13 (semver)
Affected: N/A , < 2.7.7 (semver)
Affected: N/A , < 5.16.0.0 (semver)
Affected: 7.8 , ≤ 7.13 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29177",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T19:05:17.020326Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T19:05:23.225Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:10:54.086Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            },
            {
              "lessThan": "2.7.7",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "5.16.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.8",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report."
            }
          ],
          "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 2.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T02:46:55.073Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-29177",
    "datePublished": "2024-06-26T02:46:55.073Z",
    "dateReserved": "2024-03-18T08:44:18.924Z",
    "dateUpdated": "2024-08-02T01:10:54.086Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}