CVE-2024-29175 (GCVE-0-2024-29175)
Vulnerability from cvelistv5 – Published: 2024-06-26 03:03 – Updated: 2024-08-02 01:10
VLAI?
Summary
Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information.
Severity ?
5.9 (Medium)
CWE
- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerProtect DD |
Affected:
7.0 , ≤ 7.13
(semver)
Affected: N/A , < 2.7.7 (semver) Affected: N/A , < 5.16.0.0 (semver) Affected: 7.8 , ≤ 7.13 (semver) |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:dell:powerprotect_dd:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "powerprotect_dd",
"vendor": "dell",
"versions": [
{
"lessThanOrEqual": "7.13",
"status": "affected",
"version": "7.0",
"versionType": "semver"
},
{
"lessThan": "2.7.7",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "5.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThanOrEqual": "7.13",
"status": "affected",
"version": "7.8",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-29175",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-11T15:11:41.076013Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-11T15:17:48.750Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:10:54.627Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "7.13",
"status": "affected",
"version": "7.0",
"versionType": "semver"
},
{
"lessThan": "2.7.7",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "5.16.0.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThanOrEqual": "7.13",
"status": "affected",
"version": "7.8",
"versionType": "semver"
}
]
}
],
"datePublic": "2024-06-24T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information."
}
],
"value": "Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-26T03:03:06.155Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-29175",
"datePublished": "2024-06-26T03:03:06.155Z",
"dateReserved": "2024-03-18T08:44:18.923Z",
"dateUpdated": "2024-08-02T01:10:54.627Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"7.7.5.40\", \"matchCriteriaId\": \"C6A0B6C8-491A-46F2-A330-15000DE501BA\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.8.0.0\", \"versionEndExcluding\": \"7.10.1.30\", \"matchCriteriaId\": \"28F4339F-F4B0-479A-B300-ADB987171B31\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.11.0.0\", \"versionEndExcluding\": \"7.13.1.0\", \"matchCriteriaId\": \"8EF3066F-F378-4AA6-B50C-B33C22C57492\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information.\"}, {\"lang\": \"es\", \"value\": \"Dell PowerProtect Data Domain, versiones anteriores a 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contienen una vulnerabilidad de algoritmo criptogr\\u00e1fico d\\u00e9bil. Un atacante remoto no autenticado podr\\u00eda explotar esta vulnerabilidad, lo que provocar\\u00eda un ataque de intermediario que exponga informaci\\u00f3n confidencial de la sesi\\u00f3n.\"}]",
"id": "CVE-2024-29175",
"lastModified": "2024-11-21T09:07:43.653",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 5.9, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.2, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 5.9, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.2, \"impactScore\": 3.6}]}",
"published": "2024-06-26T03:15:10.303",
"references": "[{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\", \"source\": \"security_alert@emc.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-327\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-327\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-29175\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2024-06-26T03:15:10.303\",\"lastModified\":\"2024-11-21T09:07:43.653\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information.\"},{\"lang\":\"es\",\"value\":\"Dell PowerProtect Data Domain, versiones anteriores a 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contienen una vulnerabilidad de algoritmo criptogr\u00e1fico d\u00e9bil. Un atacante remoto no autenticado podr\u00eda explotar esta vulnerabilidad, lo que provocar\u00eda un ataque de intermediario que exponga informaci\u00f3n confidencial de la sesi\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-327\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-327\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.7.5.40\",\"matchCriteriaId\":\"C6A0B6C8-491A-46F2-A330-15000DE501BA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.8.0.0\",\"versionEndExcluding\":\"7.10.1.30\",\"matchCriteriaId\":\"28F4339F-F4B0-479A-B300-ADB987171B31\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.11.0.0\",\"versionEndExcluding\":\"7.13.1.0\",\"matchCriteriaId\":\"8EF3066F-F378-4AA6-B50C-B33C22C57492\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T01:10:54.627Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-29175\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-07-11T15:11:41.076013Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:h:dell:powerprotect_dd:*:*:*:*:*:*:*:*\"], \"vendor\": \"dell\", \"product\": \"powerprotect_dd\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.13\"}, {\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.7.7\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"5.16.0.0\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"7.8\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.13\"}], \"defaultStatus\": \"unaffected\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-11T15:15:13.896Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.9, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"PowerProtect DD\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.13\"}, {\"status\": \"affected\", \"version\": \"N/A\", \"lessThan\": \"2.7.7\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"N/A\", \"lessThan\": \"5.16.0.0\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"7.8\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.13\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2024-06-24T06:30:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-327\", \"description\": \"CWE-327: Use of a Broken or Risky Cryptographic Algorithm\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2024-06-26T03:03:06.155Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-29175\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-02T01:10:54.627Z\", \"dateReserved\": \"2024-03-18T08:44:18.923Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2024-06-26T03:03:06.155Z\", \"assignerShortName\": \"dell\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…