Search
Find a vulnerability
Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
85 vulnerabilities found for PowerProtect Data Domain by Dell
CVE-2026-53478 (GCVE-0-2026-53478)
Vulnerability from nvd – Published: 2026-07-03 14:03 – Updated: 2026-07-03 14:03
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution.
Severity
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , ≤ 8.8.0.0 or later
(semver)
Affected: 0 , ≤ 8.6.1.20 or later (semver) Affected: 0 , ≤ 8.3.1.40 or later (semver) Affected: 0 , ≤ 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
Credits
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThanOrEqual": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThanOrEqual": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThanOrEqual": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank songxiaoyue for reporting this issue."
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T14:03:29.533Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-53478",
"datePublished": "2026-07-03T14:03:29.533Z",
"dateReserved": "2026-06-09T17:04:35.249Z",
"dateUpdated": "2026-07-03T14:03:29.533Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-49815 (GCVE-0-2026-49815)
Vulnerability from nvd – Published: 2026-07-03 14:09 – Updated: 2026-07-03 14:09
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to execution of arbitrary OS commands.
Severity
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to execution of arbitrary OS commands."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to execution of arbitrary OS commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T14:09:19.831Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-49815",
"datePublished": "2026-07-03T14:09:19.831Z",
"dateReserved": "2026-06-01T17:04:30.334Z",
"dateUpdated": "2026-07-03T14:09:19.831Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-49814 (GCVE-0-2026-49814)
Vulnerability from nvd – Published: 2026-07-03 14:13 – Updated: 2026-07-03 14:13
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to arbitrary command execution.
Severity
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to arbitrary command execution."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to arbitrary command execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T14:13:36.579Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-49814",
"datePublished": "2026-07-03T14:13:36.579Z",
"dateReserved": "2026-06-01T17:04:30.334Z",
"dateUpdated": "2026-07-03T14:13:36.579Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-49813 (GCVE-0-2026-49813)
Vulnerability from nvd – Published: 2026-07-03 14:18 – Updated: 2026-07-03 14:18
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution.
Severity
6.7 (Medium)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T14:18:11.239Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-49813",
"datePublished": "2026-07-03T14:18:11.239Z",
"dateReserved": "2026-06-01T17:04:30.334Z",
"dateUpdated": "2026-07-03T14:18:11.239Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46466 (GCVE-0-2026-46466)
Vulnerability from nvd – Published: 2026-07-03 13:10 – Updated: 2026-07-03 13:10
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of less trusted source vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information tampering.
Severity
CWE
- CWE-348 - Use of Less Trusted Source
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of less trusted source vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information tampering."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of less trusted source vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information tampering."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-348",
"description": "CWE-348: Use of Less Trusted Source",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T13:10:01.883Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46466",
"datePublished": "2026-07-03T13:10:01.883Z",
"dateReserved": "2026-05-14T17:05:39.859Z",
"dateUpdated": "2026-07-03T13:10:01.883Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46465 (GCVE-0-2026-46465)
Vulnerability from nvd – Published: 2026-07-03 13:16 – Updated: 2026-07-03 13:16
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of externally-controlled format string vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure and denial of service.
Severity
5.5 (Medium)
CWE
- CWE-134 - Use of Externally-Controlled Format String
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of externally-controlled format string vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure and denial of service."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of externally-controlled format string vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure and denial of service."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-134",
"description": "CWE-134: Use of Externally-Controlled Format String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T13:16:00.714Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46465",
"datePublished": "2026-07-03T13:16:00.714Z",
"dateReserved": "2026-05-14T17:05:39.859Z",
"dateUpdated": "2026-07-03T13:16:00.714Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46464 (GCVE-0-2026-46464)
Vulnerability from nvd – Published: 2026-07-03 13:32 – Updated: 2026-07-03 13:32
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information disclosure.
Severity
4.9 (Medium)
CWE
- CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access (\u0027Link following\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information disclosure."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access (\u0027Link following\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59: Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T13:32:35.091Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46464",
"datePublished": "2026-07-03T13:32:35.091Z",
"dateReserved": "2026-05-14T17:05:39.859Z",
"dateUpdated": "2026-07-03T13:32:35.091Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46463 (GCVE-0-2026-46463)
Vulnerability from nvd – Published: 2026-07-03 13:42 – Updated: 2026-07-03 13:42
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an integer overflow or wraparound vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to denial of service.
Severity
6.5 (Medium)
CWE
- CWE-190 - Integer Overflow or Wraparound
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an integer overflow or wraparound vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to denial of service."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an integer overflow or wraparound vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to denial of service."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-190",
"description": "CWE-190: Integer Overflow or Wraparound",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T13:42:07.171Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46463",
"datePublished": "2026-07-03T13:42:07.171Z",
"dateReserved": "2026-05-14T17:05:39.858Z",
"dateUpdated": "2026-07-03T13:42:07.171Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-56085 (GCVE-0-2026-56085)
Vulnerability from nvd – Published: 2026-07-03 12:46 – Updated: 2026-07-03 12:46
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of uninitialized resource vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.
Severity
CWE
- CWE-908 - Use of Uninitialized Resource
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
Credits
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank kam1tsur3 for reporting this issue."
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of uninitialized resource vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of uninitialized resource vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-908",
"description": "CWE-908: Use of Uninitialized Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T12:46:42.895Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-56085",
"datePublished": "2026-07-03T12:46:42.895Z",
"dateReserved": "2026-06-18T17:04:56.015Z",
"dateUpdated": "2026-07-03T12:46:42.895Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-54483 (GCVE-0-2026-54483)
Vulnerability from nvd – Published: 2026-07-03 12:34 – Updated: 2026-07-03 12:34
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.
Severity
6.7 (Medium)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.7.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
Credits
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.7.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank zzcentury for reporting this issue."
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T12:34:43.239Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-54483",
"datePublished": "2026-07-03T12:34:43.239Z",
"dateReserved": "2026-06-15T17:49:28.560Z",
"dateUpdated": "2026-07-03T12:34:43.239Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46730 (GCVE-0-2026-46730)
Vulnerability from nvd – Published: 2026-07-03 12:54 – Updated: 2026-07-03 12:54
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an incorrect authorization vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized command execution.
Severity
4.2 (Medium)
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an incorrect authorization vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized command execution."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an incorrect authorization vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized command execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863: Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T12:54:00.862Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46730",
"datePublished": "2026-07-03T12:54:00.862Z",
"dateReserved": "2026-05-17T17:04:27.065Z",
"dateUpdated": "2026-07-03T12:54:00.862Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46468 (GCVE-0-2026-46468)
Vulnerability from nvd – Published: 2026-07-03 12:58 – Updated: 2026-07-03 12:58
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.
Severity
4.4 (Medium)
CWE
- CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access (\u0027Link following\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access (\u0027Link following\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59: Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T12:58:46.278Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46468",
"datePublished": "2026-07-03T12:58:46.278Z",
"dateReserved": "2026-05-14T17:05:39.859Z",
"dateUpdated": "2026-07-03T12:58:46.278Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46467 (GCVE-0-2026-46467)
Vulnerability from nvd – Published: 2026-07-03 13:04 – Updated: 2026-07-03 13:04
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an insertion of sensitive information into log file vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.
Severity
5.8 (Medium)
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an insertion of sensitive information into log file vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an insertion of sensitive information into log file vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T13:04:26.935Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46467",
"datePublished": "2026-07-03T13:04:26.935Z",
"dateReserved": "2026-05-14T17:05:39.859Z",
"dateUpdated": "2026-07-03T13:04:26.935Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-44269 (GCVE-0-2026-44269)
Vulnerability from nvd – Published: 2026-07-03 12:09 – Updated: 2026-07-03 12:09
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('link following') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized access.
Severity
4.4 (Medium)
CWE
- CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.7.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.7.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access (\u0027link following\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized access."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access (\u0027link following\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59: Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T12:09:06.006Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-44269",
"datePublished": "2026-07-03T12:09:06.006Z",
"dateReserved": "2026-05-05T17:04:45.713Z",
"dateUpdated": "2026-07-03T12:09:06.006Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-44268 (GCVE-0-2026-44268)
Vulnerability from nvd – Published: 2026-07-03 12:15 – Updated: 2026-07-03 12:15
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an incorrect permission Assignment for critical resource vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized access.
Severity
4.4 (Medium)
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.7.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 12:12
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.7.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T12:12:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an incorrect permission Assignment for critical resource vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized access."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an incorrect permission Assignment for critical resource vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T12:15:22.397Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-44268",
"datePublished": "2026-07-03T12:15:22.397Z",
"dateReserved": "2026-05-05T17:04:45.713Z",
"dateUpdated": "2026-07-03T12:15:22.397Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-41124 (GCVE-0-2026-41124)
Vulnerability from nvd – Published: 2026-07-03 12:19 – Updated: 2026-07-03 12:19
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an Improper limitation of a pathname to a restricted directory ('path traversal') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure.
Severity
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an Improper limitation of a pathname to a restricted directory (\u0027path traversal\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an Improper limitation of a pathname to a restricted directory (\u0027path traversal\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 2.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T12:19:59.524Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-41124",
"datePublished": "2026-07-03T12:19:59.524Z",
"dateReserved": "2026-04-17T05:04:42.886Z",
"dateUpdated": "2026-07-03T12:19:59.524Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-41123 (GCVE-0-2026-41123)
Vulnerability from nvd – Published: 2026-07-03 12:25 – Updated: 2026-07-03 12:25
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper access control vulnerability in the RBAC. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to information tampering.
Severity
4.3 (Medium)
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.7.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
Credits
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.7.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting this issue."
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper access control vulnerability in the RBAC. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to information tampering."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper access control vulnerability in the RBAC. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to information tampering."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T12:25:47.932Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-41123",
"datePublished": "2026-07-03T12:25:47.932Z",
"dateReserved": "2026-04-17T05:04:42.886Z",
"dateUpdated": "2026-07-03T12:25:47.932Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-26355 (GCVE-0-2026-26355)
Vulnerability from nvd – Published: 2026-07-03 12:41 – Updated: 2026-07-03 12:41
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution.
Severity
6.5 (Medium)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
Credits
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank liupeng from Ubisectech Sirius Team for reporting this issue."
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T12:41:34.555Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-26355",
"datePublished": "2026-07-03T12:41:34.555Z",
"dateReserved": "2026-02-13T18:05:27.825Z",
"dateUpdated": "2026-07-03T12:41:34.555Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-49813 (GCVE-0-2026-49813)
Vulnerability from cvelistv5 – Published: 2026-07-03 14:18 – Updated: 2026-07-03 14:18
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution.
Severity
6.7 (Medium)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T14:18:11.239Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-49813",
"datePublished": "2026-07-03T14:18:11.239Z",
"dateReserved": "2026-06-01T17:04:30.334Z",
"dateUpdated": "2026-07-03T14:18:11.239Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-49814 (GCVE-0-2026-49814)
Vulnerability from cvelistv5 – Published: 2026-07-03 14:13 – Updated: 2026-07-03 14:13
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to arbitrary command execution.
Severity
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to arbitrary command execution."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to arbitrary command execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T14:13:36.579Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-49814",
"datePublished": "2026-07-03T14:13:36.579Z",
"dateReserved": "2026-06-01T17:04:30.334Z",
"dateUpdated": "2026-07-03T14:13:36.579Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-49815 (GCVE-0-2026-49815)
Vulnerability from cvelistv5 – Published: 2026-07-03 14:09 – Updated: 2026-07-03 14:09
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to execution of arbitrary OS commands.
Severity
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to execution of arbitrary OS commands."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to execution of arbitrary OS commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T14:09:19.831Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-49815",
"datePublished": "2026-07-03T14:09:19.831Z",
"dateReserved": "2026-06-01T17:04:30.334Z",
"dateUpdated": "2026-07-03T14:09:19.831Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-53478 (GCVE-0-2026-53478)
Vulnerability from cvelistv5 – Published: 2026-07-03 14:03 – Updated: 2026-07-03 14:03
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution.
Severity
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , ≤ 8.8.0.0 or later
(semver)
Affected: 0 , ≤ 8.6.1.20 or later (semver) Affected: 0 , ≤ 8.3.1.40 or later (semver) Affected: 0 , ≤ 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
Credits
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThanOrEqual": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThanOrEqual": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThanOrEqual": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank songxiaoyue for reporting this issue."
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T14:03:29.533Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-53478",
"datePublished": "2026-07-03T14:03:29.533Z",
"dateReserved": "2026-06-09T17:04:35.249Z",
"dateUpdated": "2026-07-03T14:03:29.533Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46463 (GCVE-0-2026-46463)
Vulnerability from cvelistv5 – Published: 2026-07-03 13:42 – Updated: 2026-07-03 13:42
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an integer overflow or wraparound vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to denial of service.
Severity
6.5 (Medium)
CWE
- CWE-190 - Integer Overflow or Wraparound
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an integer overflow or wraparound vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to denial of service."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an integer overflow or wraparound vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to denial of service."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-190",
"description": "CWE-190: Integer Overflow or Wraparound",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T13:42:07.171Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46463",
"datePublished": "2026-07-03T13:42:07.171Z",
"dateReserved": "2026-05-14T17:05:39.858Z",
"dateUpdated": "2026-07-03T13:42:07.171Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46464 (GCVE-0-2026-46464)
Vulnerability from cvelistv5 – Published: 2026-07-03 13:32 – Updated: 2026-07-03 13:32
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information disclosure.
Severity
4.9 (Medium)
CWE
- CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access (\u0027Link following\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information disclosure."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access (\u0027Link following\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59: Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T13:32:35.091Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46464",
"datePublished": "2026-07-03T13:32:35.091Z",
"dateReserved": "2026-05-14T17:05:39.859Z",
"dateUpdated": "2026-07-03T13:32:35.091Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46465 (GCVE-0-2026-46465)
Vulnerability from cvelistv5 – Published: 2026-07-03 13:16 – Updated: 2026-07-03 13:16
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of externally-controlled format string vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure and denial of service.
Severity
5.5 (Medium)
CWE
- CWE-134 - Use of Externally-Controlled Format String
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of externally-controlled format string vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure and denial of service."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of externally-controlled format string vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure and denial of service."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-134",
"description": "CWE-134: Use of Externally-Controlled Format String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T13:16:00.714Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46465",
"datePublished": "2026-07-03T13:16:00.714Z",
"dateReserved": "2026-05-14T17:05:39.859Z",
"dateUpdated": "2026-07-03T13:16:00.714Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46466 (GCVE-0-2026-46466)
Vulnerability from cvelistv5 – Published: 2026-07-03 13:10 – Updated: 2026-07-03 13:10
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of less trusted source vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information tampering.
Severity
CWE
- CWE-348 - Use of Less Trusted Source
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of less trusted source vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information tampering."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of less trusted source vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information tampering."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-348",
"description": "CWE-348: Use of Less Trusted Source",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T13:10:01.883Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46466",
"datePublished": "2026-07-03T13:10:01.883Z",
"dateReserved": "2026-05-14T17:05:39.859Z",
"dateUpdated": "2026-07-03T13:10:01.883Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46467 (GCVE-0-2026-46467)
Vulnerability from cvelistv5 – Published: 2026-07-03 13:04 – Updated: 2026-07-03 13:04
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an insertion of sensitive information into log file vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.
Severity
5.8 (Medium)
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an insertion of sensitive information into log file vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an insertion of sensitive information into log file vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T13:04:26.935Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46467",
"datePublished": "2026-07-03T13:04:26.935Z",
"dateReserved": "2026-05-14T17:05:39.859Z",
"dateUpdated": "2026-07-03T13:04:26.935Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46468 (GCVE-0-2026-46468)
Vulnerability from cvelistv5 – Published: 2026-07-03 12:58 – Updated: 2026-07-03 12:58
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.
Severity
4.4 (Medium)
CWE
- CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access (\u0027Link following\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access (\u0027Link following\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59: Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T12:58:46.278Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46468",
"datePublished": "2026-07-03T12:58:46.278Z",
"dateReserved": "2026-05-14T17:05:39.859Z",
"dateUpdated": "2026-07-03T12:58:46.278Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46730 (GCVE-0-2026-46730)
Vulnerability from cvelistv5 – Published: 2026-07-03 12:54 – Updated: 2026-07-03 12:54
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an incorrect authorization vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized command execution.
Severity
4.2 (Medium)
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an incorrect authorization vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized command execution."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an incorrect authorization vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized command execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863: Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T12:54:00.862Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46730",
"datePublished": "2026-07-03T12:54:00.862Z",
"dateReserved": "2026-05-17T17:04:27.065Z",
"dateUpdated": "2026-07-03T12:54:00.862Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-56085 (GCVE-0-2026-56085)
Vulnerability from cvelistv5 – Published: 2026-07-03 12:46 – Updated: 2026-07-03 12:46
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of uninitialized resource vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure.
Severity
CWE
- CWE-908 - Use of Uninitialized Resource
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
Credits
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank kam1tsur3 for reporting this issue."
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of uninitialized resource vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of uninitialized resource vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-908",
"description": "CWE-908: Use of Uninitialized Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T12:46:42.895Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-56085",
"datePublished": "2026-07-03T12:46:42.895Z",
"dateReserved": "2026-06-18T17:04:56.015Z",
"dateUpdated": "2026-07-03T12:46:42.895Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}