    CVE-2026-22268 (GCVE-0-2026-22268)

    Vulnerability from nvd – Published: 2026-02-19 09:12 – Updated: 2026-02-20 16:11
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to denial of service of a Dell Enterprise Support connection.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-266 - Incorrect Privilege Assignment
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.22.0-24 or later (semver)
    Create a notification for this product.
    Date Public
    2026-02-17 18:30
    Credits
    Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting these issues.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22268",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-20T16:11:13.947710Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-20T16:11:27.190Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.22.0-24 or later",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "other",
              "value": "Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting these issues."
            }
          ],
          "datePublic": "2026-02-17T18:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to denial of service of a Dell Enterprise Support connection.\u003cbr\u003e"
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to denial of service of a Dell Enterprise Support connection."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-266",
                  "description": "CWE-266: Incorrect Privilege Assignment",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-19T09:12:08.514Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000429778/dsa-2026-046-security-update-for-dell-powerprotect-data-manager-multiple-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2026-22268",
        "datePublished": "2026-02-19T09:12:08.514Z",
        "dateReserved": "2026-01-07T06:43:46.537Z",
        "dateUpdated": "2026-02-20T16:11:27.190Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-22267 (GCVE-0-2026-22267)

    Vulnerability from nvd – Published: 2026-02-19 09:16 – Updated: 2026-02-26 14:44
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-266 - Incorrect Privilege Assignment
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.22.0-24 or later (semver)
    Create a notification for this product.
    Date Public
    2026-02-17 18:30
    Credits
    Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting these issues.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22267",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-21T04:56:32.486024Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T14:44:14.633Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.22.0-24 or later",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "other",
              "value": "Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting these issues."
            }
          ],
          "datePublic": "2026-02-17T18:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.\u003cbr\u003e"
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-266",
                  "description": "CWE-266: Incorrect Privilege Assignment",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-19T09:16:54.151Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000429778/dsa-2026-046-security-update-for-dell-powerprotect-data-manager-multiple-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2026-22267",
        "datePublished": "2026-02-19T09:16:54.151Z",
        "dateReserved": "2026-01-07T06:43:46.536Z",
        "dateUpdated": "2026-02-26T14:44:14.633Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-22266 (GCVE-0-2026-22266)

    Vulnerability from nvd – Published: 2026-02-19 09:06 – Updated: 2026-02-20 16:10
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Improper Verification of Source of a Communication Channel vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to protection mechanism bypass.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-146 - Improper Neutralization of Expression/Command Delimiters
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.22.0-24 or later (semver)
    Create a notification for this product.
    Date Public
    2026-02-17 18:30
    Credits
    Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting these issues.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22266",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-20T16:10:37.399792Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-20T16:10:51.265Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.22.0-24 or later",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "other",
              "value": "Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting these issues."
            }
          ],
          "datePublic": "2026-02-17T18:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Improper Verification of Source of a Communication Channel vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to protection mechanism bypass.\u003cbr\u003e"
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Improper Verification of Source of a Communication Channel vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to protection mechanism bypass."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-146",
                  "description": "CWE-146: Improper Neutralization of Expression/Command Delimiters",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-19T09:06:21.289Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000429778/dsa-2026-046-security-update-for-dell-powerprotect-data-manager-multiple-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2026-22266",
        "datePublished": "2026-02-19T09:06:21.289Z",
        "dateReserved": "2026-01-07T06:43:46.536Z",
        "dateUpdated": "2026-02-20T16:10:51.265Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-22269 (GCVE-0-2026-22269)

    Vulnerability from nvd – Published: 2026-02-19 09:00 – Updated: 2026-02-20 16:09
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Improper Verification of Source of a Communication Channel vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to protection mechanism bypass.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-940 - Improper Verification of Source of a Communication Channel
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.22.0-24 or later (semver)
    Create a notification for this product.
    Date Public
    2026-02-17 18:30
    Credits
    Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting these issues.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22269",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-20T16:09:11.236982Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-20T16:09:36.834Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.22.0-24 or later",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "other",
              "value": "Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting these issues."
            }
          ],
          "datePublic": "2026-02-17T18:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Improper Verification of Source of a Communication Channel vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to protection mechanism bypass.\u003cbr\u003e"
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Improper Verification of Source of a Communication Channel vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to protection mechanism bypass."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-940",
                  "description": "CWE-940: Improper Verification of Source of a Communication Channel",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-19T09:00:56.035Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000429778/dsa-2026-046-security-update-for-dell-powerprotect-data-manager-multiple-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2026-22269",
        "datePublished": "2026-02-19T09:00:56.035Z",
        "dateReserved": "2026-01-07T06:43:46.537Z",
        "dateUpdated": "2026-02-20T16:09:36.834Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-43886 (GCVE-0-2025-43886)

    Vulnerability from nvd – Published: 2025-09-10 16:08 – Updated: 2025-09-11 13:24
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Path Traversal: '.../...//' vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-35 - Path Traversal: '.../...//'
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
    Create a notification for this product.
    Date Public
    2025-09-09 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43886",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-11T13:24:22.142728Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-11T13:24:30.089Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.21 build 11",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-09-09T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Path Traversal: \u0027.../...//\u0027 vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker."
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Path Traversal: \u0027.../...//\u0027 vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 4.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-35",
                  "description": "CWE-35: Path Traversal: \u0027.../...//\u0027",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-10T16:08:55.075Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-43886",
        "datePublished": "2025-09-10T16:08:55.075Z",
        "dateReserved": "2025-04-18T05:05:05.741Z",
        "dateUpdated": "2025-09-11T13:24:30.089Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-43938 (GCVE-0-2025-43938)

    Vulnerability from nvd – Published: 2025-09-10 16:03 – Updated: 2025-09-10 18:04
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Plaintext Storage of a Password vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to gain unauthorized access with privileges of the compromised account.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-256 - Plaintext Storage of a Password
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
    Create a notification for this product.
    Date Public
    2025-09-09 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43938",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-10T18:04:05.557915Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-10T18:04:13.097Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.21 build 11",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-09-09T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Plaintext Storage of a Password vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to gain unauthorized access with privileges of the compromised account."
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Plaintext Storage of a Password vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to gain unauthorized access with privileges of the compromised account."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-256",
                  "description": "CWE-256: Plaintext Storage of a Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-10T16:03:38.951Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-43938",
        "datePublished": "2025-09-10T16:03:38.951Z",
        "dateReserved": "2025-04-20T05:04:01.415Z",
        "dateUpdated": "2025-09-10T18:04:13.097Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-43887 (GCVE-0-2025-43887)

    Vulnerability from nvd – Published: 2025-09-10 15:59 – Updated: 2026-02-26 17:48
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-276 - Incorrect Default Permissions
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
    Create a notification for this product.
    Date Public
    2025-09-09 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43887",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-11T03:56:28.607021Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:48:43.142Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.21 build 11",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-09-09T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-276",
                  "description": "CWE-276: Incorrect Default Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-10T15:59:56.185Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-43887",
        "datePublished": "2025-09-10T15:59:56.185Z",
        "dateReserved": "2025-04-18T05:05:05.741Z",
        "dateUpdated": "2026-02-26T17:48:43.142Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-43725 (GCVE-0-2025-43725)

    Vulnerability from nvd – Published: 2025-09-10 15:56 – Updated: 2026-02-26 17:48
    VLAI
    Summary
    Dell PowerProtect Data Manager, Generic Application Agent, version(s) 19.19 and 19.20, contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-276 - Incorrect Default Permissions
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
    Create a notification for this product.
    Date Public
    2025-09-09 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43725",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-11T03:56:29.492613Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:48:43.554Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.21 build 11",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-09-09T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, Generic Application Agent, version(s) 19.19 and 19.20, contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution."
                }
              ],
              "value": "Dell PowerProtect Data Manager, Generic Application Agent, version(s) 19.19 and 19.20, contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-276",
                  "description": "CWE-276: Incorrect Default Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-10T15:56:08.961Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-43725",
        "datePublished": "2025-09-10T15:56:08.961Z",
        "dateReserved": "2025-04-17T05:03:55.667Z",
        "dateUpdated": "2026-02-26T17:48:43.554Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-43885 (GCVE-0-2025-43885)

    Vulnerability from nvd – Published: 2025-09-10 15:52 – Updated: 2026-02-26 17:48
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
    Create a notification for this product.
    Date Public
    2025-09-09 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43885",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-11T03:56:24.294455Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:48:43.857Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.21 build 11",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-09-09T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-10T15:52:28.608Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-43885",
        "datePublished": "2025-09-10T15:52:28.608Z",
        "dateReserved": "2025-04-18T05:05:05.741Z",
        "dateUpdated": "2026-02-26T17:48:43.857Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-43884 (GCVE-0-2025-43884)

    Vulnerability from nvd – Published: 2025-09-10 15:47 – Updated: 2026-02-26 17:48
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
    Create a notification for this product.
    Date Public
    2025-09-09 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43884",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-11T03:56:25.200519Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:48:44.165Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.21 build 11",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-09-09T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-10T15:47:40.671Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-43884",
        "datePublished": "2025-09-10T15:47:40.671Z",
        "dateReserved": "2025-04-18T05:05:05.740Z",
        "dateUpdated": "2026-02-26T17:48:44.165Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-43888 (GCVE-0-2025-43888)

    Vulnerability from nvd – Published: 2025-09-10 15:42 – Updated: 2026-02-26 17:48
    VLAI
    Summary
    Dell PowerProtect Data Manager, Hyper-V, version(s) 19.19 and 19.20, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-532 - Insertion of Sensitive Information into Log File
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
    Create a notification for this product.
    Date Public
    2025-09-09 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43888",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-11T03:56:26.040843Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:48:44.642Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.21 build 11",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-09-09T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, Hyper-V, version(s) 19.19 and 19.20, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access."
                }
              ],
              "value": "Dell PowerProtect Data Manager, Hyper-V, version(s) 19.19 and 19.20, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-532",
                  "description": "CWE-532: Insertion of Sensitive Information into Log File",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-10T15:43:08.746Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-43888",
        "datePublished": "2025-09-10T15:42:34.448Z",
        "dateReserved": "2025-04-18T05:05:05.741Z",
        "dateUpdated": "2026-02-26T17:48:44.642Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-30480 (GCVE-0-2025-30480)

    Vulnerability from nvd – Published: 2025-07-30 18:01 – Updated: 2025-07-30 18:21
    VLAI
    Summary
    Dell PowerProtect Data Manager, versions prior to 19.19, contain(s) an Improper Input Validation vulnerability in PowerProtect Data Manager. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.20 (semver)
    Create a notification for this product.
    Date Public
    2025-07-29 17:00
    Credits
    Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-30480",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-30T18:20:42.511595Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-30T18:21:24.665Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.20",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue."
            }
          ],
          "datePublic": "2025-07-29T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect Data Manager, versions prior to 19.19, contain(s) an Improper Input Validation vulnerability in PowerProtect Data Manager. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files.\u003c/span\u003e"
                }
              ],
              "value": "Dell PowerProtect Data Manager, versions prior to 19.19, contain(s) an Improper Input Validation vulnerability in PowerProtect Data Manager. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20: Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-30T18:01:53.920Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000349609/dsa-2025-304-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-30480",
        "datePublished": "2025-07-30T18:01:53.920Z",
        "dateReserved": "2025-03-23T18:45:23.729Z",
        "dateUpdated": "2025-07-30T18:21:24.665Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23377 (GCVE-0-2025-23377)

    Vulnerability from nvd – Published: 2025-04-28 14:38 – Updated: 2025-04-28 14:50
    VLAI
    Summary
    Dell PowerProtect Data Manager Reporting, version(s) 19.17, 19.18 contain(s) an Improper Encoding or Escaping of Output vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability to inject arbitrary web script or html in reporting outputs.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-116 - Improper Encoding or Escaping of Output
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: 19.15.0 , ≤ 19.18.0-23 (semver)
    Create a notification for this product.
    Date Public
    2025-04-24 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23377",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-28T14:50:02.276406Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-28T14:50:15.238Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThanOrEqual": "19.18.0-23",
                  "status": "affected",
                  "version": "19.15.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-04-24T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.17, 19.18 contain(s) an Improper Encoding or Escaping of Output vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability to inject arbitrary web script or html in reporting outputs.\u003cbr\u003e"
                }
              ],
              "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.17, 19.18 contain(s) an Improper Encoding or Escaping of Output vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability to inject arbitrary web script or html in reporting outputs."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 4.2,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-116",
                  "description": "CWE-116: Improper Encoding or Escaping of Output",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-28T14:38:01.852Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000311083/dsa-2025-062-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-23377",
        "datePublished": "2025-04-28T14:38:01.852Z",
        "dateReserved": "2025-01-15T06:04:03.641Z",
        "dateUpdated": "2025-04-28T14:50:15.238Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23375 (GCVE-0-2025-23375)

    Vulnerability from nvd – Published: 2025-04-28 14:28 – Updated: 2026-02-26 18:28
    VLAI
    Summary
    Dell PowerProtect Data Manager Reporting, version(s) 19.17, contain(s) an Incorrect Use of Privileged APIs vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-648 - Incorrect Use of Privileged APIs
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: 19.15.0 , ≤ 19.18.0-23 (semver)
    Create a notification for this product.
    Date Public
    2025-04-24 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23375",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-30T03:56:26.272858Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T18:28:00.559Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThanOrEqual": "19.18.0-23",
                  "status": "affected",
                  "version": "19.15.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-04-24T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.17, contain(s) an Incorrect Use of Privileged APIs vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.\u003cbr\u003e"
                }
              ],
              "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.17, contain(s) an Incorrect Use of Privileged APIs vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-648",
                  "description": "CWE-648: Incorrect Use of Privileged APIs",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-28T14:28:03.669Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000311083/dsa-2025-062-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-23375",
        "datePublished": "2025-04-28T14:28:03.669Z",
        "dateReserved": "2025-01-15T06:04:03.641Z",
        "dateUpdated": "2026-02-26T18:28:00.559Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-25971 (GCVE-0-2024-25971)

    Vulnerability from nvd – Published: 2024-03-28 18:43 – Updated: 2024-08-01 23:52
    VLAI
    Summary
    Dell PowerProtect Data Manager, version 19.15, contains an XML External Entity Injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to information disclosure, denial-of-service.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-611 - Improper Restriction of XML External Entity Reference
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.16 (semver)
    Create a notification for this product.
    Date Public
    2024-03-28 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-25971",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-03-28T19:31:40.256120Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-05T17:21:20.844Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T23:52:06.184Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000223556/dsa-2024-132-security-update-dell-power-protect-data-manager-for-multiple-security-vulnerabilities"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.16",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2024-03-28T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version 19.15, contains an XML External Entity Injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to information disclosure, denial-of-service."
                }
              ],
              "value": "Dell PowerProtect Data Manager, version 19.15, contains an XML External Entity Injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to information disclosure, denial-of-service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611: Improper Restriction of XML External Entity Reference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-28T18:43:06.075Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000223556/dsa-2024-132-security-update-dell-power-protect-data-manager-for-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2024-25971",
        "datePublished": "2024-03-28T18:43:06.075Z",
        "dateReserved": "2024-02-13T05:34:25.249Z",
        "dateUpdated": "2024-08-01T23:52:06.184Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-22267 (GCVE-0-2026-22267)

    Vulnerability from cvelistv5 – Published: 2026-02-19 09:16 – Updated: 2026-02-26 14:44
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-266 - Incorrect Privilege Assignment
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.22.0-24 or later (semver)
    Create a notification for this product.
    Date Public
    2026-02-17 18:30
    Credits
    Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting these issues.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22267",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-21T04:56:32.486024Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T14:44:14.633Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.22.0-24 or later",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "other",
              "value": "Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting these issues."
            }
          ],
          "datePublic": "2026-02-17T18:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.\u003cbr\u003e"
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-266",
                  "description": "CWE-266: Incorrect Privilege Assignment",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-19T09:16:54.151Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000429778/dsa-2026-046-security-update-for-dell-powerprotect-data-manager-multiple-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2026-22267",
        "datePublished": "2026-02-19T09:16:54.151Z",
        "dateReserved": "2026-01-07T06:43:46.536Z",
        "dateUpdated": "2026-02-26T14:44:14.633Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-22268 (GCVE-0-2026-22268)

    Vulnerability from cvelistv5 – Published: 2026-02-19 09:12 – Updated: 2026-02-20 16:11
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to denial of service of a Dell Enterprise Support connection.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-266 - Incorrect Privilege Assignment
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.22.0-24 or later (semver)
    Create a notification for this product.
    Date Public
    2026-02-17 18:30
    Credits
    Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting these issues.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22268",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-20T16:11:13.947710Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-20T16:11:27.190Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.22.0-24 or later",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "other",
              "value": "Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting these issues."
            }
          ],
          "datePublic": "2026-02-17T18:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to denial of service of a Dell Enterprise Support connection.\u003cbr\u003e"
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to denial of service of a Dell Enterprise Support connection."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-266",
                  "description": "CWE-266: Incorrect Privilege Assignment",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-19T09:12:08.514Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000429778/dsa-2026-046-security-update-for-dell-powerprotect-data-manager-multiple-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2026-22268",
        "datePublished": "2026-02-19T09:12:08.514Z",
        "dateReserved": "2026-01-07T06:43:46.537Z",
        "dateUpdated": "2026-02-20T16:11:27.190Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-22266 (GCVE-0-2026-22266)

    Vulnerability from cvelistv5 – Published: 2026-02-19 09:06 – Updated: 2026-02-20 16:10
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Improper Verification of Source of a Communication Channel vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to protection mechanism bypass.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-146 - Improper Neutralization of Expression/Command Delimiters
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.22.0-24 or later (semver)
    Create a notification for this product.
    Date Public
    2026-02-17 18:30
    Credits
    Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting these issues.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22266",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-20T16:10:37.399792Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-20T16:10:51.265Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.22.0-24 or later",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "other",
              "value": "Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting these issues."
            }
          ],
          "datePublic": "2026-02-17T18:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Improper Verification of Source of a Communication Channel vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to protection mechanism bypass.\u003cbr\u003e"
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Improper Verification of Source of a Communication Channel vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to protection mechanism bypass."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-146",
                  "description": "CWE-146: Improper Neutralization of Expression/Command Delimiters",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-19T09:06:21.289Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000429778/dsa-2026-046-security-update-for-dell-powerprotect-data-manager-multiple-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2026-22266",
        "datePublished": "2026-02-19T09:06:21.289Z",
        "dateReserved": "2026-01-07T06:43:46.536Z",
        "dateUpdated": "2026-02-20T16:10:51.265Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-22269 (GCVE-0-2026-22269)

    Vulnerability from cvelistv5 – Published: 2026-02-19 09:00 – Updated: 2026-02-20 16:09
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Improper Verification of Source of a Communication Channel vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to protection mechanism bypass.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-940 - Improper Verification of Source of a Communication Channel
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.22.0-24 or later (semver)
    Create a notification for this product.
    Date Public
    2026-02-17 18:30
    Credits
    Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting these issues.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22269",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-20T16:09:11.236982Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-20T16:09:36.834Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.22.0-24 or later",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "other",
              "value": "Dell would like to thank brocked200 (Nguyen Quoc Khanh) for reporting these issues."
            }
          ],
          "datePublic": "2026-02-17T18:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Improper Verification of Source of a Communication Channel vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to protection mechanism bypass.\u003cbr\u003e"
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Improper Verification of Source of a Communication Channel vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to protection mechanism bypass."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-940",
                  "description": "CWE-940: Improper Verification of Source of a Communication Channel",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-19T09:00:56.035Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000429778/dsa-2026-046-security-update-for-dell-powerprotect-data-manager-multiple-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2026-22269",
        "datePublished": "2026-02-19T09:00:56.035Z",
        "dateReserved": "2026-01-07T06:43:46.537Z",
        "dateUpdated": "2026-02-20T16:09:36.834Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-43886 (GCVE-0-2025-43886)

    Vulnerability from cvelistv5 – Published: 2025-09-10 16:08 – Updated: 2025-09-11 13:24
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Path Traversal: '.../...//' vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-35 - Path Traversal: '.../...//'
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
    Create a notification for this product.
    Date Public
    2025-09-09 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43886",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-11T13:24:22.142728Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-11T13:24:30.089Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.21 build 11",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-09-09T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Path Traversal: \u0027.../...//\u0027 vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker."
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Path Traversal: \u0027.../...//\u0027 vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 4.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-35",
                  "description": "CWE-35: Path Traversal: \u0027.../...//\u0027",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-10T16:08:55.075Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-43886",
        "datePublished": "2025-09-10T16:08:55.075Z",
        "dateReserved": "2025-04-18T05:05:05.741Z",
        "dateUpdated": "2025-09-11T13:24:30.089Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-43938 (GCVE-0-2025-43938)

    Vulnerability from cvelistv5 – Published: 2025-09-10 16:03 – Updated: 2025-09-10 18:04
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Plaintext Storage of a Password vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to gain unauthorized access with privileges of the compromised account.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-256 - Plaintext Storage of a Password
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
    Create a notification for this product.
    Date Public
    2025-09-09 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43938",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-10T18:04:05.557915Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-10T18:04:13.097Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.21 build 11",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-09-09T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Plaintext Storage of a Password vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to gain unauthorized access with privileges of the compromised account."
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) a Plaintext Storage of a Password vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to gain unauthorized access with privileges of the compromised account."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-256",
                  "description": "CWE-256: Plaintext Storage of a Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-10T16:03:38.951Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-43938",
        "datePublished": "2025-09-10T16:03:38.951Z",
        "dateReserved": "2025-04-20T05:04:01.415Z",
        "dateUpdated": "2025-09-10T18:04:13.097Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-43887 (GCVE-0-2025-43887)

    Vulnerability from cvelistv5 – Published: 2025-09-10 15:59 – Updated: 2026-02-26 17:48
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-276 - Incorrect Default Permissions
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
    Create a notification for this product.
    Date Public
    2025-09-09 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43887",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-11T03:56:28.607021Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:48:43.142Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.21 build 11",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-09-09T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-276",
                  "description": "CWE-276: Incorrect Default Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-10T15:59:56.185Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-43887",
        "datePublished": "2025-09-10T15:59:56.185Z",
        "dateReserved": "2025-04-18T05:05:05.741Z",
        "dateUpdated": "2026-02-26T17:48:43.142Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-43725 (GCVE-0-2025-43725)

    Vulnerability from cvelistv5 – Published: 2025-09-10 15:56 – Updated: 2026-02-26 17:48
    VLAI
    Summary
    Dell PowerProtect Data Manager, Generic Application Agent, version(s) 19.19 and 19.20, contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-276 - Incorrect Default Permissions
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
    Create a notification for this product.
    Date Public
    2025-09-09 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43725",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-11T03:56:29.492613Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:48:43.554Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.21 build 11",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-09-09T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, Generic Application Agent, version(s) 19.19 and 19.20, contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution."
                }
              ],
              "value": "Dell PowerProtect Data Manager, Generic Application Agent, version(s) 19.19 and 19.20, contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-276",
                  "description": "CWE-276: Incorrect Default Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-10T15:56:08.961Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-43725",
        "datePublished": "2025-09-10T15:56:08.961Z",
        "dateReserved": "2025-04-17T05:03:55.667Z",
        "dateUpdated": "2026-02-26T17:48:43.554Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-43885 (GCVE-0-2025-43885)

    Vulnerability from cvelistv5 – Published: 2025-09-10 15:52 – Updated: 2026-02-26 17:48
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
    Create a notification for this product.
    Date Public
    2025-09-09 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43885",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-11T03:56:24.294455Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:48:43.857Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.21 build 11",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-09-09T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-10T15:52:28.608Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-43885",
        "datePublished": "2025-09-10T15:52:28.608Z",
        "dateReserved": "2025-04-18T05:05:05.741Z",
        "dateUpdated": "2026-02-26T17:48:43.857Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-43884 (GCVE-0-2025-43884)

    Vulnerability from cvelistv5 – Published: 2025-09-10 15:47 – Updated: 2026-02-26 17:48
    VLAI
    Summary
    Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
    Create a notification for this product.
    Date Public
    2025-09-09 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43884",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-11T03:56:25.200519Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:48:44.165Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.21 build 11",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-09-09T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
                }
              ],
              "value": "Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-10T15:47:40.671Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-43884",
        "datePublished": "2025-09-10T15:47:40.671Z",
        "dateReserved": "2025-04-18T05:05:05.740Z",
        "dateUpdated": "2026-02-26T17:48:44.165Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-43888 (GCVE-0-2025-43888)

    Vulnerability from cvelistv5 – Published: 2025-09-10 15:42 – Updated: 2026-02-26 17:48
    VLAI
    Summary
    Dell PowerProtect Data Manager, Hyper-V, version(s) 19.19 and 19.20, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-532 - Insertion of Sensitive Information into Log File
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.21 build 11 (semver)
    Create a notification for this product.
    Date Public
    2025-09-09 17:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43888",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-11T03:56:26.040843Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T17:48:44.642Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.21 build 11",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-09-09T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, Hyper-V, version(s) 19.19 and 19.20, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access."
                }
              ],
              "value": "Dell PowerProtect Data Manager, Hyper-V, version(s) 19.19 and 19.20, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-532",
                  "description": "CWE-532: Insertion of Sensitive Information into Log File",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-10T15:43:08.746Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000367456/dsa-2025-326-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-43888",
        "datePublished": "2025-09-10T15:42:34.448Z",
        "dateReserved": "2025-04-18T05:05:05.741Z",
        "dateUpdated": "2026-02-26T17:48:44.642Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-30480 (GCVE-0-2025-30480)

    Vulnerability from cvelistv5 – Published: 2025-07-30 18:01 – Updated: 2025-07-30 18:21
    VLAI
    Summary
    Dell PowerProtect Data Manager, versions prior to 19.19, contain(s) an Improper Input Validation vulnerability in PowerProtect Data Manager. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.20 (semver)
    Create a notification for this product.
    Date Public
    2025-07-29 17:00
    Credits
    Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-30480",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-30T18:20:42.511595Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-30T18:21:24.665Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.20",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell would like to thank zzcentury from Ubisectech Sirius Team for reporting this issue."
            }
          ],
          "datePublic": "2025-07-29T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect Data Manager, versions prior to 19.19, contain(s) an Improper Input Validation vulnerability in PowerProtect Data Manager. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files.\u003c/span\u003e"
                }
              ],
              "value": "Dell PowerProtect Data Manager, versions prior to 19.19, contain(s) an Improper Input Validation vulnerability in PowerProtect Data Manager. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20: Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-30T18:01:53.920Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000349609/dsa-2025-304-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-30480",
        "datePublished": "2025-07-30T18:01:53.920Z",
        "dateReserved": "2025-03-23T18:45:23.729Z",
        "dateUpdated": "2025-07-30T18:21:24.665Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23377 (GCVE-0-2025-23377)

    Vulnerability from cvelistv5 – Published: 2025-04-28 14:38 – Updated: 2025-04-28 14:50
    VLAI
    Summary
    Dell PowerProtect Data Manager Reporting, version(s) 19.17, 19.18 contain(s) an Improper Encoding or Escaping of Output vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability to inject arbitrary web script or html in reporting outputs.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-116 - Improper Encoding or Escaping of Output
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: 19.15.0 , ≤ 19.18.0-23 (semver)
    Create a notification for this product.
    Date Public
    2025-04-24 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23377",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-28T14:50:02.276406Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-28T14:50:15.238Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThanOrEqual": "19.18.0-23",
                  "status": "affected",
                  "version": "19.15.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-04-24T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.17, 19.18 contain(s) an Improper Encoding or Escaping of Output vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability to inject arbitrary web script or html in reporting outputs.\u003cbr\u003e"
                }
              ],
              "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.17, 19.18 contain(s) an Improper Encoding or Escaping of Output vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability to inject arbitrary web script or html in reporting outputs."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 4.2,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-116",
                  "description": "CWE-116: Improper Encoding or Escaping of Output",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-28T14:38:01.852Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000311083/dsa-2025-062-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-23377",
        "datePublished": "2025-04-28T14:38:01.852Z",
        "dateReserved": "2025-01-15T06:04:03.641Z",
        "dateUpdated": "2025-04-28T14:50:15.238Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-23375 (GCVE-0-2025-23375)

    Vulnerability from cvelistv5 – Published: 2025-04-28 14:28 – Updated: 2026-02-26 18:28
    VLAI
    Summary
    Dell PowerProtect Data Manager Reporting, version(s) 19.17, contain(s) an Incorrect Use of Privileged APIs vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-648 - Incorrect Use of Privileged APIs
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: 19.15.0 , ≤ 19.18.0-23 (semver)
    Create a notification for this product.
    Date Public
    2025-04-24 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-23375",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-30T03:56:26.272858Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T18:28:00.559Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThanOrEqual": "19.18.0-23",
                  "status": "affected",
                  "version": "19.15.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2025-04-24T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.17, contain(s) an Incorrect Use of Privileged APIs vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.\u003cbr\u003e"
                }
              ],
              "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.17, contain(s) an Incorrect Use of Privileged APIs vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-648",
                  "description": "CWE-648: Incorrect Use of Privileged APIs",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-28T14:28:03.669Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000311083/dsa-2025-062-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2025-23375",
        "datePublished": "2025-04-28T14:28:03.669Z",
        "dateReserved": "2025-01-15T06:04:03.641Z",
        "dateUpdated": "2026-02-26T18:28:00.559Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-25971 (GCVE-0-2024-25971)

    Vulnerability from cvelistv5 – Published: 2024-03-28 18:43 – Updated: 2024-08-01 23:52
    VLAI
    Summary
    Dell PowerProtect Data Manager, version 19.15, contains an XML External Entity Injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to information disclosure, denial-of-service.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-611 - Improper Restriction of XML External Entity Reference
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerProtect Data Manager Affected: N/A , < 19.16 (semver)
    Create a notification for this product.
    Date Public
    2024-03-28 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-25971",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-03-28T19:31:40.256120Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-05T17:21:20.844Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T23:52:06.184Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000223556/dsa-2024-132-security-update-dell-power-protect-data-manager-for-multiple-security-vulnerabilities"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerProtect Data Manager",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "19.16",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "datePublic": "2024-03-28T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell PowerProtect Data Manager, version 19.15, contains an XML External Entity Injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to information disclosure, denial-of-service."
                }
              ],
              "value": "Dell PowerProtect Data Manager, version 19.15, contains an XML External Entity Injection vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to information disclosure, denial-of-service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611: Improper Restriction of XML External Entity Reference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-28T18:43:06.075Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000223556/dsa-2024-132-security-update-dell-power-protect-data-manager-for-multiple-security-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2024-25971",
        "datePublished": "2024-03-28T18:43:06.075Z",
        "dateReserved": "2024-02-13T05:34:25.249Z",
        "dateUpdated": "2024-08-01T23:52:06.184Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }