Search criteria

2 vulnerabilities found for PowerProtect Data Manager Reporting by Dell

CVE-2025-23376 (GCVE-0-2025-23376)

Vulnerability from cvelistv5 – Published: 2025-04-28 14:34 – Updated: 2025-04-28 17:31
VLAI?
Summary
Dell PowerProtect Data Manager Reporting, version(s) 19.16, 19.17, 19.18, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure.
CWE
  • CWE-1336 - Improper Neutralization of Special Elements Used in a Template Engine
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Reporting Affected: 19.15.0 , ≤ 19.18.0-23 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-23376",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-28T17:30:57.741219Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-28T17:31:27.959Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager Reporting",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "19.18.0-23",
              "status": "affected",
              "version": "19.15.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-04-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.16, 19.17, 19.18, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure.\u003cbr\u003e"
            }
          ],
          "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.16, 19.17, 19.18, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 2.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1336",
              "description": "CWE-1336: Improper Neutralization of Special Elements Used in a Template Engine",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-28T14:34:13.504Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000311083/dsa-2025-062-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-23376",
    "datePublished": "2025-04-28T14:34:13.504Z",
    "dateReserved": "2025-01-15T06:04:03.641Z",
    "dateUpdated": "2025-04-28T17:31:27.959Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-23376 (GCVE-0-2025-23376)

Vulnerability from nvd – Published: 2025-04-28 14:34 – Updated: 2025-04-28 17:31
VLAI?
Summary
Dell PowerProtect Data Manager Reporting, version(s) 19.16, 19.17, 19.18, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure.
CWE
  • CWE-1336 - Improper Neutralization of Special Elements Used in a Template Engine
Assigner
References
Impacted products
Vendor Product Version
Dell PowerProtect Data Manager Reporting Affected: 19.15.0 , ≤ 19.18.0-23 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-23376",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-28T17:30:57.741219Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-28T17:31:27.959Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect Data Manager Reporting",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "19.18.0-23",
              "status": "affected",
              "version": "19.15.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-04-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.16, 19.17, 19.18, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure.\u003cbr\u003e"
            }
          ],
          "value": "Dell PowerProtect Data Manager Reporting, version(s) 19.16, 19.17, 19.18, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 2.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1336",
              "description": "CWE-1336: Improper Neutralization of Special Elements Used in a Template Engine",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-28T14:34:13.504Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000311083/dsa-2025-062-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-23376",
    "datePublished": "2025-04-28T14:34:13.504Z",
    "dateReserved": "2025-01-15T06:04:03.641Z",
    "dateUpdated": "2025-04-28T17:31:27.959Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}