Search criteria

8 vulnerabilities found for ProGauge MagLink LX 4 by Dover Fueling Solutions

CVE-2025-30519 (GCVE-0-2025-30519)

Vulnerability from cvelistv5 – Published: 2025-09-18 20:46 – Updated: 2025-09-19 13:05
VLAI?
Summary
Dover Fueling Solutions ProGauge MagLink LX4 Devices have default root credentials that cannot be changed through standard administrative means. An attacker with network access to the device can gain administrative access to the system.
CWE
Assigner
Credits
Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30519",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-19T13:05:08.342046Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-19T13:05:20.889Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX 4",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Plus",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Ultimate",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "5.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions ProGauge MagLink LX4 Devices\u0026nbsp;have default root credentials that cannot be changed through standard \nadministrative means. An attacker with network access to the device can \ngain administrative access to the system."
            }
          ],
          "value": "Dover Fueling Solutions ProGauge MagLink LX4 Devices\u00a0have default root credentials that cannot be changed through standard \nadministrative means. An attacker with network access to the device can \ngain administrative access to the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1391",
              "description": "CWE-1391",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-18T20:46:42.642Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-07"
        },
        {
          "url": "https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html\"\u003ewebsite\u003c/a\u003e\u0026nbsp;.\u003cp\u003eFor MagLink LX Ultimate devices, Dover Fueling Solutions recommends users \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html\"\u003eupdate to version 5.20.3\u003c/a\u003e\u0026nbsp;or later.\u003c/p\u003e\n\u003cp\u003eDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions  website https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html \u00a0.For MagLink LX Ultimate devices, Dover Fueling Solutions recommends users  update to version 5.20.3 https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html \u00a0or later.\n\n\nDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks."
        }
      ],
      "source": {
        "advisory": "ICSA-25-261-07",
        "discovery": "EXTERNAL"
      },
      "title": "Dover Fueling Solutions ProGauge MagLink LX4 Devices Use of Weak Credentials",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-30519",
    "datePublished": "2025-09-18T20:46:42.642Z",
    "dateReserved": "2025-08-18T15:32:05.607Z",
    "dateUpdated": "2025-09-19T13:05:20.889Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-54807 (GCVE-0-2025-54807)

Vulnerability from cvelistv5 – Published: 2025-09-18 20:44 – Updated: 2025-09-19 13:06
VLAI?
Summary
The secret used for validating authentication tokens is hardcoded in device firmware for affected versions. An attacker who obtains the signing key can bypass authentication, gaining complete access to the system.
CWE
Assigner
Credits
Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-54807",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-19T13:05:56.641781Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-19T13:06:19.294Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX 4",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Plus",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Ultimate",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "5.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The secret used for validating authentication tokens is hardcoded in \ndevice firmware for affected versions. An attacker who obtains the \nsigning key can bypass authentication, gaining complete access to the \nsystem."
            }
          ],
          "value": "The secret used for validating authentication tokens is hardcoded in \ndevice firmware for affected versions. An attacker who obtains the \nsigning key can bypass authentication, gaining complete access to the \nsystem."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-18T20:44:04.094Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-07"
        },
        {
          "url": "https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html\"\u003ewebsite\u003c/a\u003e\u0026nbsp;.\u003cp\u003eFor MagLink LX Ultimate devices, Dover Fueling Solutions recommends users \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html\"\u003eupdate to version 5.20.3\u003c/a\u003e\u0026nbsp;or later.\u003c/p\u003e\n\u003cp\u003eDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions  website https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html \u00a0.For MagLink LX Ultimate devices, Dover Fueling Solutions recommends users  update to version 5.20.3 https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html \u00a0or later.\n\n\nDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks."
        }
      ],
      "source": {
        "advisory": "ICSA-25-261-07",
        "discovery": "EXTERNAL"
      },
      "title": "Dover Fueling Solutions ProGauge MagLink LX4 Devices Use of Hard-coded Cryptographic Key",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-54807",
    "datePublished": "2025-09-18T20:44:04.094Z",
    "dateReserved": "2025-08-18T15:32:05.596Z",
    "dateUpdated": "2025-09-19T13:06:19.294Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-55068 (GCVE-0-2025-55068)

Vulnerability from cvelistv5 – Published: 2025-09-18 20:42 – Updated: 2025-09-19 13:06
VLAI?
Summary
Dover Fueling Solutions ProGauge MagLink LX4 Devices fail to handle Unix time values beyond a certain point. An attacker can manually change the system time to exploit this limitation, potentially causing errors in authentication and leading to a denial-of-service condition.
CWE
Assigner
Credits
Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-55068",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-19T13:06:34.220442Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-19T13:06:42.627Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX 4",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Plus",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Ultimate",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "5.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions ProGauge MagLink LX4 Devices fail to handle Unix time values beyond a certain point.\n An attacker can manually change the system time to exploit this \nlimitation, potentially causing errors in authentication and leading to a\n denial-of-service condition."
            }
          ],
          "value": "Dover Fueling Solutions ProGauge MagLink LX4 Devices fail to handle Unix time values beyond a certain point.\n An attacker can manually change the system time to exploit this \nlimitation, potentially causing errors in authentication and leading to a\n denial-of-service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-190",
              "description": "CWE-190",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-18T20:42:29.547Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-07"
        },
        {
          "url": "https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html\"\u003ewebsite\u003c/a\u003e\u0026nbsp;.\u003cp\u003eFor MagLink LX Ultimate devices, Dover Fueling Solutions recommends users \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html\"\u003eupdate to version 5.20.3\u003c/a\u003e\u0026nbsp;or later.\u003c/p\u003e\n\u003cp\u003eDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions  website https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html \u00a0.For MagLink LX Ultimate devices, Dover Fueling Solutions recommends users  update to version 5.20.3 https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html \u00a0or later.\n\n\nDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks."
        }
      ],
      "source": {
        "advisory": "ICSA-25-261-07",
        "discovery": "EXTERNAL"
      },
      "title": "Dover Fueling Solutions ProGauge MagLink LX4 Devices Integer Overflow or Wraparound",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-55068",
    "datePublished": "2025-09-18T20:42:29.547Z",
    "dateReserved": "2025-08-18T15:32:05.574Z",
    "dateUpdated": "2025-09-19T13:06:42.627Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-5310 (GCVE-0-2025-5310)

Vulnerability from cvelistv5 – Published: 2025-06-27 17:22 – Updated: 2025-06-27 17:41
VLAI?
Summary
Dover Fueling Solutions ProGauge MagLink LX Consoles expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution.
CWE
Assigner
Credits
Souvik Kandar of Microsec reported this vulnerability to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-5310",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-27T17:41:36.119969Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-27T17:41:45.800Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX 4",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Plus",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Ultimate",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "5.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Souvik Kandar of Microsec reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions ProGauge MagLink LX Consoles\u0026nbsp;expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution."
            }
          ],
          "value": "Dover Fueling Solutions ProGauge MagLink LX Consoles\u00a0expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-27T17:22:02.680Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-168-05"
        },
        {
          "url": "https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx?OR=Teams%2DHL\u0026CT=1736953471669\u0026id=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017%2FVU%23285756%20%2D%20Dover%20Fueling%20Solutions%20ProGauge%20MAGLINK%20%2D%20Notice%20%28Draft%29%2Ehtml\u0026viewid=243fd1ea%2Da122%2D4cc0%2Dbe91%2Dd0714ca46b87\u0026parent=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx?OR=Teams%2DHL\u0026amp;CT=1736953471669\u0026amp;id=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017%2FVU%23285756%20%2D%20Dover%20Fueling%20Solutions%20ProGauge%20MAGLINK%20%2D%20Notice%20%28Draft%29%2Ehtml\u0026amp;viewid=243fd1ea%2Da122%2D4cc0%2Dbe91%2Dd0714ca46b87\u0026amp;parent=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017\"\u003ewebsite\u003c/a\u003e.\u003cp\u003eFor MagLink LX Ultimate devices, Dover Fueling Solutions recommends users \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx?OR=Teams%2DHL\u0026amp;CT=1736953471669\u0026amp;id=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017%2FVU%23285756%20%2D%20Dover%20Fueling%20Solutions%20ProGauge%20MAGLINK%20%2D%20Notice%20%28Draft%29%2Ehtml\u0026amp;viewid=243fd1ea%2Da122%2D4cc0%2Dbe91%2Dd0714ca46b87\u0026amp;parent=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017\"\u003eupdate to version 5.20.3\u003c/a\u003e\u0026nbsp;or later.\n\n\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions  website https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx .For MagLink LX Ultimate devices, Dover Fueling Solutions recommends users  update to version 5.20.3 https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx \u00a0or later."
        }
      ],
      "source": {
        "advisory": "ICSA-25-168-05",
        "discovery": "EXTERNAL"
      },
      "title": "Dover Fueling Solutions ProGauge MagLink LX Consoles Missing Authentication for Critical Function",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-5310",
    "datePublished": "2025-06-27T17:22:02.680Z",
    "dateReserved": "2025-05-28T21:03:37.200Z",
    "dateUpdated": "2025-06-27T17:41:45.800Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-30519 (GCVE-0-2025-30519)

Vulnerability from nvd – Published: 2025-09-18 20:46 – Updated: 2025-09-19 13:05
VLAI?
Summary
Dover Fueling Solutions ProGauge MagLink LX4 Devices have default root credentials that cannot be changed through standard administrative means. An attacker with network access to the device can gain administrative access to the system.
CWE
Assigner
Credits
Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30519",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-19T13:05:08.342046Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-19T13:05:20.889Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX 4",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Plus",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Ultimate",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "5.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions ProGauge MagLink LX4 Devices\u0026nbsp;have default root credentials that cannot be changed through standard \nadministrative means. An attacker with network access to the device can \ngain administrative access to the system."
            }
          ],
          "value": "Dover Fueling Solutions ProGauge MagLink LX4 Devices\u00a0have default root credentials that cannot be changed through standard \nadministrative means. An attacker with network access to the device can \ngain administrative access to the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1391",
              "description": "CWE-1391",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-18T20:46:42.642Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-07"
        },
        {
          "url": "https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html\"\u003ewebsite\u003c/a\u003e\u0026nbsp;.\u003cp\u003eFor MagLink LX Ultimate devices, Dover Fueling Solutions recommends users \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html\"\u003eupdate to version 5.20.3\u003c/a\u003e\u0026nbsp;or later.\u003c/p\u003e\n\u003cp\u003eDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions  website https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html \u00a0.For MagLink LX Ultimate devices, Dover Fueling Solutions recommends users  update to version 5.20.3 https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html \u00a0or later.\n\n\nDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks."
        }
      ],
      "source": {
        "advisory": "ICSA-25-261-07",
        "discovery": "EXTERNAL"
      },
      "title": "Dover Fueling Solutions ProGauge MagLink LX4 Devices Use of Weak Credentials",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-30519",
    "datePublished": "2025-09-18T20:46:42.642Z",
    "dateReserved": "2025-08-18T15:32:05.607Z",
    "dateUpdated": "2025-09-19T13:05:20.889Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-54807 (GCVE-0-2025-54807)

Vulnerability from nvd – Published: 2025-09-18 20:44 – Updated: 2025-09-19 13:06
VLAI?
Summary
The secret used for validating authentication tokens is hardcoded in device firmware for affected versions. An attacker who obtains the signing key can bypass authentication, gaining complete access to the system.
CWE
Assigner
Credits
Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-54807",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-19T13:05:56.641781Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-19T13:06:19.294Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX 4",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Plus",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Ultimate",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "5.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The secret used for validating authentication tokens is hardcoded in \ndevice firmware for affected versions. An attacker who obtains the \nsigning key can bypass authentication, gaining complete access to the \nsystem."
            }
          ],
          "value": "The secret used for validating authentication tokens is hardcoded in \ndevice firmware for affected versions. An attacker who obtains the \nsigning key can bypass authentication, gaining complete access to the \nsystem."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-18T20:44:04.094Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-07"
        },
        {
          "url": "https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html\"\u003ewebsite\u003c/a\u003e\u0026nbsp;.\u003cp\u003eFor MagLink LX Ultimate devices, Dover Fueling Solutions recommends users \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html\"\u003eupdate to version 5.20.3\u003c/a\u003e\u0026nbsp;or later.\u003c/p\u003e\n\u003cp\u003eDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions  website https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html \u00a0.For MagLink LX Ultimate devices, Dover Fueling Solutions recommends users  update to version 5.20.3 https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html \u00a0or later.\n\n\nDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks."
        }
      ],
      "source": {
        "advisory": "ICSA-25-261-07",
        "discovery": "EXTERNAL"
      },
      "title": "Dover Fueling Solutions ProGauge MagLink LX4 Devices Use of Hard-coded Cryptographic Key",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-54807",
    "datePublished": "2025-09-18T20:44:04.094Z",
    "dateReserved": "2025-08-18T15:32:05.596Z",
    "dateUpdated": "2025-09-19T13:06:19.294Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-55068 (GCVE-0-2025-55068)

Vulnerability from nvd – Published: 2025-09-18 20:42 – Updated: 2025-09-19 13:06
VLAI?
Summary
Dover Fueling Solutions ProGauge MagLink LX4 Devices fail to handle Unix time values beyond a certain point. An attacker can manually change the system time to exploit this limitation, potentially causing errors in authentication and leading to a denial-of-service condition.
CWE
Assigner
Credits
Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-55068",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-19T13:06:34.220442Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-19T13:06:42.627Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX 4",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Plus",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Ultimate",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "5.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions ProGauge MagLink LX4 Devices fail to handle Unix time values beyond a certain point.\n An attacker can manually change the system time to exploit this \nlimitation, potentially causing errors in authentication and leading to a\n denial-of-service condition."
            }
          ],
          "value": "Dover Fueling Solutions ProGauge MagLink LX4 Devices fail to handle Unix time values beyond a certain point.\n An attacker can manually change the system time to exploit this \nlimitation, potentially causing errors in authentication and leading to a\n denial-of-service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-190",
              "description": "CWE-190",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-18T20:42:29.547Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-07"
        },
        {
          "url": "https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html\"\u003ewebsite\u003c/a\u003e\u0026nbsp;.\u003cp\u003eFor MagLink LX Ultimate devices, Dover Fueling Solutions recommends users \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html\"\u003eupdate to version 5.20.3\u003c/a\u003e\u0026nbsp;or later.\u003c/p\u003e\n\u003cp\u003eDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions  website https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html \u00a0.For MagLink LX Ultimate devices, Dover Fueling Solutions recommends users  update to version 5.20.3 https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html \u00a0or later.\n\n\nDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks."
        }
      ],
      "source": {
        "advisory": "ICSA-25-261-07",
        "discovery": "EXTERNAL"
      },
      "title": "Dover Fueling Solutions ProGauge MagLink LX4 Devices Integer Overflow or Wraparound",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-55068",
    "datePublished": "2025-09-18T20:42:29.547Z",
    "dateReserved": "2025-08-18T15:32:05.574Z",
    "dateUpdated": "2025-09-19T13:06:42.627Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-5310 (GCVE-0-2025-5310)

Vulnerability from nvd – Published: 2025-06-27 17:22 – Updated: 2025-06-27 17:41
VLAI?
Summary
Dover Fueling Solutions ProGauge MagLink LX Consoles expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution.
CWE
Assigner
Credits
Souvik Kandar of Microsec reported this vulnerability to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-5310",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-27T17:41:36.119969Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-27T17:41:45.800Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX 4",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Plus",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Ultimate",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "5.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Souvik Kandar of Microsec reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions ProGauge MagLink LX Consoles\u0026nbsp;expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution."
            }
          ],
          "value": "Dover Fueling Solutions ProGauge MagLink LX Consoles\u00a0expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-27T17:22:02.680Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-168-05"
        },
        {
          "url": "https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx?OR=Teams%2DHL\u0026CT=1736953471669\u0026id=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017%2FVU%23285756%20%2D%20Dover%20Fueling%20Solutions%20ProGauge%20MAGLINK%20%2D%20Notice%20%28Draft%29%2Ehtml\u0026viewid=243fd1ea%2Da122%2D4cc0%2Dbe91%2Dd0714ca46b87\u0026parent=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx?OR=Teams%2DHL\u0026amp;CT=1736953471669\u0026amp;id=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017%2FVU%23285756%20%2D%20Dover%20Fueling%20Solutions%20ProGauge%20MAGLINK%20%2D%20Notice%20%28Draft%29%2Ehtml\u0026amp;viewid=243fd1ea%2Da122%2D4cc0%2Dbe91%2Dd0714ca46b87\u0026amp;parent=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017\"\u003ewebsite\u003c/a\u003e.\u003cp\u003eFor MagLink LX Ultimate devices, Dover Fueling Solutions recommends users \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx?OR=Teams%2DHL\u0026amp;CT=1736953471669\u0026amp;id=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017%2FVU%23285756%20%2D%20Dover%20Fueling%20Solutions%20ProGauge%20MAGLINK%20%2D%20Notice%20%28Draft%29%2Ehtml\u0026amp;viewid=243fd1ea%2Da122%2D4cc0%2Dbe91%2Dd0714ca46b87\u0026amp;parent=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017\"\u003eupdate to version 5.20.3\u003c/a\u003e\u0026nbsp;or later.\n\n\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions  website https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx .For MagLink LX Ultimate devices, Dover Fueling Solutions recommends users  update to version 5.20.3 https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx \u00a0or later."
        }
      ],
      "source": {
        "advisory": "ICSA-25-168-05",
        "discovery": "EXTERNAL"
      },
      "title": "Dover Fueling Solutions ProGauge MagLink LX Consoles Missing Authentication for Critical Function",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-5310",
    "datePublished": "2025-06-27T17:22:02.680Z",
    "dateReserved": "2025-05-28T21:03:37.200Z",
    "dateUpdated": "2025-06-27T17:41:45.800Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}