CVE-2025-30519 (GCVE-0-2025-30519)

Vulnerability from cvelistv5 – Published: 2025-09-18 20:46 – Updated: 2025-09-19 13:05
VLAI?
Summary
Dover Fueling Solutions ProGauge MagLink LX4 Devices have default root credentials that cannot be changed through standard administrative means. An attacker with network access to the device can gain administrative access to the system.
CWE
Assigner
Credits
Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30519",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-19T13:05:08.342046Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-19T13:05:20.889Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX 4",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Plus",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Ultimate",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "5.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions ProGauge MagLink LX4 Devices\u0026nbsp;have default root credentials that cannot be changed through standard \nadministrative means. An attacker with network access to the device can \ngain administrative access to the system."
            }
          ],
          "value": "Dover Fueling Solutions ProGauge MagLink LX4 Devices\u00a0have default root credentials that cannot be changed through standard \nadministrative means. An attacker with network access to the device can \ngain administrative access to the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1391",
              "description": "CWE-1391",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-18T20:46:42.642Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-07"
        },
        {
          "url": "https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html\"\u003ewebsite\u003c/a\u003e\u0026nbsp;.\u003cp\u003eFor MagLink LX Ultimate devices, Dover Fueling Solutions recommends users \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html\"\u003eupdate to version 5.20.3\u003c/a\u003e\u0026nbsp;or later.\u003c/p\u003e\n\u003cp\u003eDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions  website https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html \u00a0.For MagLink LX Ultimate devices, Dover Fueling Solutions recommends users  update to version 5.20.3 https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html \u00a0or later.\n\n\nDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks."
        }
      ],
      "source": {
        "advisory": "ICSA-25-261-07",
        "discovery": "EXTERNAL"
      },
      "title": "Dover Fueling Solutions ProGauge MagLink LX4 Devices Use of Weak Credentials",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-30519",
    "datePublished": "2025-09-18T20:46:42.642Z",
    "dateReserved": "2025-08-18T15:32:05.607Z",
    "dateUpdated": "2025-09-19T13:05:20.889Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-30519\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2025-09-18T21:15:47.553\",\"lastModified\":\"2025-09-19T16:00:27.847\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dover Fueling Solutions ProGauge MagLink LX4 Devices\u00a0have default root credentials that cannot be changed through standard \\nadministrative means. An attacker with network access to the device can \\ngain administrative access to the system.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":9.3,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1391\"}]}],\"references\":[{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-07\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html\",\"source\":\"ics-cert@hq.dhs.gov\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-30519\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-09-19T13:05:08.342046Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-09-19T13:05:13.315Z\"}}], \"cna\": {\"title\": \"Dover Fueling Solutions ProGauge MagLink LX4 Devices Use of Weak Credentials\", \"source\": {\"advisory\": \"ICSA-25-261-07\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 9.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dover Fueling Solutions\", \"product\": \"ProGauge MagLink LX 4\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.20.3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Dover Fueling Solutions\", \"product\": \"ProGauge MagLink LX Plus\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.20.3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Dover Fueling Solutions\", \"product\": \"ProGauge MagLink LX Ultimate\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"5.20.3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Dover Fueling Solutions recommends users update their ProGauge MagLink \\ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \\nmodels. The upgrade can be downloaded from the Dover Fueling Solutions  website https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html \\u00a0.For MagLink LX Ultimate devices, Dover Fueling Solutions recommends users  update to version 5.20.3 https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html \\u00a0or later.\\n\\n\\nDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dover Fueling Solutions recommends users update their ProGauge MagLink \\ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \\nmodels. The upgrade can be downloaded from the Dover Fueling Solutions \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html\\\"\u003ewebsite\u003c/a\u003e\u0026nbsp;.\u003cp\u003eFor MagLink LX Ultimate devices, Dover Fueling Solutions recommends users \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html\\\"\u003eupdate to version 5.20.3\u003c/a\u003e\u0026nbsp;or later.\u003c/p\u003e\\n\u003cp\u003eDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks.\u003c/p\u003e\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-07\"}, {\"url\": \"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dover Fueling Solutions ProGauge MagLink LX4 Devices\\u00a0have default root credentials that cannot be changed through standard \\nadministrative means. An attacker with network access to the device can \\ngain administrative access to the system.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dover Fueling Solutions ProGauge MagLink LX4 Devices\u0026nbsp;have default root credentials that cannot be changed through standard \\nadministrative means. An attacker with network access to the device can \\ngain administrative access to the system.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1391\", \"description\": \"CWE-1391\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2025-09-18T20:46:42.642Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-30519\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-09-19T13:05:20.889Z\", \"dateReserved\": \"2025-08-18T15:32:05.607Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2025-09-18T20:46:42.642Z\", \"assignerShortName\": \"icscert\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…