var-201910-1595
Vulnerability from variot
A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET200AL, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels, SIMATIC PN/PN Coupler, SIMATIC PROFINET Driver, SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 PN Control Unit, SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS NET PN/PN Coupler, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. Affected devices improperly handle large amounts of specially crafted UDP packets.
This could allow an unauthenticated remote attacker to trigger a denial of service condition. Several Siemens products are vulnerable to resource exhaustion.Denial of service (DoS) May be in a state. Siemens SIMATIC CFU PA and so on are the products of Germany's Siemens company. Siemens SIMATIC CFU PA is a compact field device. SIMATIC ET 200AL is a distributed I / O system module. SIMATIC ET 200M is a modular I / O system module for control cabinets for high density channel applications. A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), SIMATIC CFU PA (All versions < V1.2.0), SIMATIC ET 200AL (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM 155-5 PN BA (All versions < V4.3.0), SIMATIC ET 200MP IM 155-5 PN HF (All versions), SIMATIC ET 200MP IM 155-5 PN ST (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM 155-6 PN BA (All versions), SIMATIC ET 200SP IM 155-6 PN HA (All versions), SIMATIC ET 200SP IM 155-6 PN HF (All versions < V4.2.2), SIMATIC ET 200SP IM 155-6 PN HS (All versions), SIMATIC ET 200SP IM 155-6 PN ST (All versions), SIMATIC ET 200SP IM 155-6 PN/2 HF (All versions < V4.2.2), SIMATIC ET 200SP IM 155-6 PN/3 HF (All versions < V4.2.1), SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET 200pro (All versions), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels (All versions), SIMATIC PN/PN Coupler (All versions), SIMATIC PROFINET Driver (All versions < V2.1), SIMATIC S7-1200 CPU family (incl. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. SIMATIC S7-1500 is a programmable logic controller. SINUMERIK 840D sl is a set of advanced machine tool numerical control system. The following products and versions are affected: Siemens SIMATIC S7-1500 CPU series (including: related ET200 CPUs and SIPLUS variants); SIMATIC S7-1500 Software Controller; SIMATIC TDC CP51M1; SIMATIC TDC CPU555; SINAMICS DCM, etc
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201910-1595", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic cfu pa", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "1.2.0" }, { "model": "simatic profinet driver", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "2.1" }, { "model": "dk standard ethernet controller", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic et 200al", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic et 200m", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic et 200s", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 1.0, "vendor": "sinumerik 828d", "version": "4.8" }, { "model": "simatic s7-1500t cpu", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "sinamics g150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "simatic s7-410 v8", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.2.2" }, { "model": "sinamics g130", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "simatic winac rtx \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2010" }, { "model": "dk standard ethernet controller", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics dcp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.3" }, { "model": "simatic hmi ktp mobile panels", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et 200sp im 155-6 pn st", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et 200sp im 155-6 pn hs", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic pn\\/pn coupler", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.2.1" }, { "model": "sinamics s150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "simatic s7-300 cpu 314 ifm", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "sinumerik 840d sl", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-300 cpu 318-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "sinamics gl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et 200pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-300 cpu 313", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "sinamics sl150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinumerik 828d", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-400 dp v7", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et 200m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et 200sp im 155-6 pn ha", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-400h v6", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.0.9" }, { "model": "simatic et 200sp im 155-6 pn ba", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics g110m", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic et 200mp im 155-5 pn ba", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3.0" }, { "model": "simatic et 200s", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics gm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics sl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic s7-300 cpu 316-2 dp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "sinamics g120", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic et 200sp im 155-6 pn\\/3 hf", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.2.1" }, { "model": "simatic s7-1500s cpu", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-300 cpu", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "simatic s7-300 cpu 314", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "sinamics gl150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics g110m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "sinumerik 828d", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-400 v6", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.0.9" }, { "model": "simatic et 200mp im 155-5 pn hf", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.4.0" }, { "model": "sinamics g120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic s7-300 cpu 315-2 dp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "simatic et 200al", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-300 cpu 312 ifm", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "simatic s7-300 cpu 315", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "simatic s7-1500 cpu", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics s110", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1500 cpu 1512c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-1200 cpu 1212c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.4.0" }, { "model": "ek-ertec 200p", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.6" }, { "model": "sinamics g150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "sinamics gm150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic et 200ecopn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics dcm", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "1.5" }, { "model": "ek-ertec 200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et 200sp im 155-6 pn\\/2 hf", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.2.2" }, { "model": "ek-ertec 200p", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.6" }, { "model": "sinamics sm120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn v7", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic winac rtx \\", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2010" }, { "model": "simatic s7-1500 cpu 1518", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-1500 cpu 1511c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "sinamics s150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "simatic s7-1200 cpu 1211c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.4.0" }, { "model": "sinamics s120", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "sinamics g130", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "simatic s7-1200 cpu", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.4.0" }, { "model": "simatic et 200mp im 155-5 pn st", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1200 cpu 1214c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.4.0" }, { "model": "sinamics s120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "simatic et 200sp im 155-6 pn hf", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.2.2" }, { "model": "sinamics dcm", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.5" }, { "model": "ek-ertec 200", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "ek-ertec 200p p", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cfu pa", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200mp im 155-5 pn ba", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200mp im 155-5 pn hf", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200mp im 155-5 pn st", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "ek-ertec", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "200" }, { "model": "ek-ertec 200p", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et 200mp im pn ba", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-5\u003c4.2.3" }, { "model": "simatic et 200mp im pn hf", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-5" }, { "model": "simatic et 200mp im pn st", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-5" }, { "model": "simatic et 200sp im pn ba", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-6" }, { "model": "simatic et 200sp im pn ha", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-6" }, { "model": "simatic et 200sp im pn hf", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-6\u003c4.2.2" }, { "model": "simatic et 200sp im pn hs", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-6" }, { "model": "simatic et 200sp im pn st", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-6" }, { "model": "simatic et 200sp im pn/2 hf", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-6\u003c4.2.2" }, { "model": "simatic et 200sp im pn/3 hf", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "155-6\u003c4.2.1" }, { "model": "simatic et 200ecopn", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et 200pro", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort outdoor panels 7\" \u0026 15\"", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort panels 4\" 22\"", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic pn/pn coupler", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-300 cpu family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn/dp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v7" }, { "model": "simatic s7-400 and below", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v6" }, { "model": "simatic s7-400h", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v6\u003c6.0.9" }, { "model": "simatic s7-410", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v8" }, { "model": "simatic winac rtx", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "2010" }, { "model": "sinamics dcm", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics dcp", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics g110m sp10 hf5", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7\u003cv4.7" }, { "model": "sinamics g120 sp10 hf5", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7\u003cv4.7" }, { "model": "sinamics g130", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7" }, { "model": "sinamics g150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics gh150", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7" }, { "model": "sinamics gl150", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7" }, { "model": "sinamics gm150", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7" }, { "model": "sinamics s110", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics s120", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7" }, { "model": "sinamics s150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics sl150", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7" }, { "model": "sinamics sm120", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7" }, { "model": "sinumerik 828d sp5", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v4.8" }, { "model": "sinumerik 840d sl", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "dk standard ethernet controller", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200s", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp im 155 6 pn ba", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp im 155 6 pn ha", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp im 155 6 pn hf", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp im 155 6 pn hs", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp im 155 6 pn st", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp im 155 6 pn 2 hf", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp im 155 6 pn 3 hf", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200ecopn", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200pro", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ek ertec 200", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort outdoor panels 7", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort outdoor panels 15", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort panels 4", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort panels 22", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic pn pn coupler", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic profinet driver", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1200 cpu", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1200 cpu 1211c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1200 cpu 1212c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ek ertec 200p", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1200 cpu 1214c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500 cpu", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500s cpu", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500t cpu", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500 cpu 1518", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500 cpu 1511c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500 cpu 1512c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu 312 ifm", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu 313", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cfu pa", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu 314", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu 314 ifm", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu 315", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu 315 2 dp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu 316 2 dp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300 cpu 318 2", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400 pn v7", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400 dp v7", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400 v6", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400h v6", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200al", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 410 v8", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic winac rtx f 2010", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics dcm", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics dcm", "version": "1.5" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics dcp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g110m", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g120", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g130", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics gl150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics gm150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200m", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s110", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s120", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics sl150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics sm120", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinumerik 828d", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinumerik 840d sl", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200mp im 155 5 pn ba", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200mp im 155 5 pn hf", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200mp im 155 5 pn st", "version": "*" } ], "sources": [ { "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "db": "CNVD", "id": "CNVD-2019-36853" }, { "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "db": "NVD", "id": "CVE-2019-10936" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:4.6:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_ba_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_ba:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_hf_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.4.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_hf:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_st_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_st:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_ba_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_ba:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_ha_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_ha:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_hf_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.2.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_hf:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_hs_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_hs:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_st_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_st:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn\\/2_hf_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.2.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn\\/2_hf:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn\\/3_hf_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.2.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn\\/3_hf:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.2.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_profinet_driver_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.4.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.4.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.4.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.4.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500s_cpu_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500s_cpu:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500t_cpu_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500t_cpu:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.3.17", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.3.17", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.3.17", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.3.17", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.3.17", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.3.17", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.3.17", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.3.17", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.3.17", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_pn_v7_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_pn_v7:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_dp_v7_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_dp_v7:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_v6_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.0.9", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_v6:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.0.9", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.2.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2010", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.5", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.5:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.7", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.7", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g120_firmware:4.7:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "5.2", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:5.2:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "5.2", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:5.2:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.8", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.8", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s110_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "5.2", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "5.2", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.2:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.7", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.7:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sm120_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.8", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp3:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp4:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2019-10936" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported this vulnerability to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-201910-639" } ], "trust": 0.6 }, "cve": "CVE-2019-10936", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.0, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2019-10936", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2019-36853", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "ea2714fa-253a-4380-82d5-35652a5540fb", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-142532", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2019-10936", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2019-10936", "trust": 1.8, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2019-10936", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2019-36853", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201910-639", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-142532", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "db": "CNVD", "id": "CNVD-2019-36853" }, { "db": "VULHUB", "id": "VHN-142532" }, { "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "db": "NVD", "id": "CVE-2019-10936" }, { "db": "NVD", "id": "CVE-2019-10936" }, { "db": "CNNVD", "id": "CNNVD-201910-639" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET200AL, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels, SIMATIC PN/PN Coupler, SIMATIC PROFINET Driver, SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 PN Control Unit, SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS NET PN/PN Coupler, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. Affected devices improperly handle large amounts of specially crafted UDP packets. \r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition. Several Siemens products are vulnerable to resource exhaustion.Denial of service (DoS) May be in a state. Siemens SIMATIC CFU PA and so on are the products of Germany\u0027s Siemens company. Siemens SIMATIC CFU PA is a compact field device. SIMATIC ET 200AL is a distributed I / O system module. SIMATIC ET 200M is a modular I / O system module for control cabinets for high density channel applications. A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), SIMATIC CFU PA (All versions \u003c V1.2.0), SIMATIC ET 200AL (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM 155-5 PN BA (All versions \u003c V4.3.0), SIMATIC ET 200MP IM 155-5 PN HF (All versions), SIMATIC ET 200MP IM 155-5 PN ST (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM 155-6 PN BA (All versions), SIMATIC ET 200SP IM 155-6 PN HA (All versions), SIMATIC ET 200SP IM 155-6 PN HF (All versions \u003c V4.2.2), SIMATIC ET 200SP IM 155-6 PN HS (All versions), SIMATIC ET 200SP IM 155-6 PN ST (All versions), SIMATIC ET 200SP IM 155-6 PN/2 HF (All versions \u003c V4.2.2), SIMATIC ET 200SP IM 155-6 PN/3 HF (All versions \u003c V4.2.1), SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET 200pro (All versions), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions), SIMATIC HMI Comfort Panels 4\" - 22\" (All versions), SIMATIC HMI KTP Mobile Panels (All versions), SIMATIC PN/PN Coupler (All versions), SIMATIC PROFINET Driver (All versions \u003c V2.1), SIMATIC S7-1200 CPU family (incl. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. SIMATIC S7-1500 is a programmable logic controller. SINUMERIK 840D sl is a set of advanced machine tool numerical control system. The following products and versions are affected: Siemens SIMATIC S7-1500 CPU series (including: related ET200 CPUs and SIPLUS variants); SIMATIC S7-1500 Software Controller; SIMATIC TDC CP51M1; SIMATIC TDC CPU555; SINAMICS DCM, etc", "sources": [ { "db": "NVD", "id": "CVE-2019-10936" }, { "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "db": "CNVD", "id": "CNVD-2019-36853" }, { "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "db": "VULHUB", "id": "VHN-142532" } ], "trust": 2.43 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-10936", "trust": 3.3 }, { "db": "SIEMENS", "id": "SSA-473245", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-19-283-02", "trust": 1.4 }, { "db": "CNNVD", "id": "CNNVD-201910-639", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2019-36853", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2019-010605", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2019.3813", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.3813.3", "trust": 0.6 }, { "db": "IVD", "id": "EA2714FA-253A-4380-82D5-35652A5540FB", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-142532", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "db": "CNVD", "id": "CNVD-2019-36853" }, { "db": "VULHUB", "id": "VHN-142532" }, { "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "db": "NVD", "id": "CVE-2019-10936" }, { "db": "CNNVD", "id": "CNNVD-201910-639" } ] }, "id": "VAR-201910-1595", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "db": "CNVD", "id": "CNVD-2019-36853" }, { "db": "VULHUB", "id": "VHN-142532" } ], "trust": 1.633110274222222 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "db": "CNVD", "id": "CNVD-2019-36853" } ] }, "last_update_date": "2023-12-18T13:13:13.201000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-473245", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" }, { "title": "Patch for Multiple Siemens Product Denial of Service Vulnerabilities (CNVD-2019-36853)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/186551" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-36853" }, { "db": "JVNDB", "id": "JVNDB-2019-010605" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-142532" }, { "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "db": "NVD", "id": "CVE-2019-10936" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" }, { "trust": 1.4, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-283-02" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-10936" }, { "trust": 1.2, "url": "https://vigilance.fr/vulnerability/simatic-denial-of-service-via-profinet-udp-packets-30562" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-10936" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.3813/" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-19-283-02" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.3813.3/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-36853" }, { "db": "VULHUB", "id": "VHN-142532" }, { "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "db": "NVD", "id": "CVE-2019-10936" }, { "db": "CNNVD", "id": "CNNVD-201910-639" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "db": "CNVD", "id": "CNVD-2019-36853" }, { "db": "VULHUB", "id": "VHN-142532" }, { "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "db": "NVD", "id": "CVE-2019-10936" }, { "db": "CNNVD", "id": "CNNVD-201910-639" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-10-23T00:00:00", "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "date": "2019-10-23T00:00:00", "db": "CNVD", "id": "CNVD-2019-36853" }, { "date": "2019-10-10T00:00:00", "db": "VULHUB", "id": "VHN-142532" }, { "date": "2019-10-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "date": "2019-10-10T14:15:14.707000", "db": "NVD", "id": "CVE-2019-10936" }, { "date": "2019-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-201910-639" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-10-23T00:00:00", "db": "CNVD", "id": "CNVD-2019-36853" }, { "date": "2023-01-10T00:00:00", "db": "VULHUB", "id": "VHN-142532" }, { "date": "2019-11-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-010605" }, { "date": "2023-05-09T13:15:13.053000", "db": "NVD", "id": "CVE-2019-10936" }, { "date": "2023-05-10T00:00:00", "db": "CNNVD", "id": "CNNVD-201910-639" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201910-639" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Multiple Siemens products vulnerable to resource depletion", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-010605" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Resource management error", "sources": [ { "db": "IVD", "id": "ea2714fa-253a-4380-82d5-35652a5540fb" }, { "db": "CNNVD", "id": "CNNVD-201910-639" } ], "trust": 0.8 } }
var-201712-0703
Vulnerability from variot
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC Compact Field Unit, SIMATIC ET200AL, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-200 SMART, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 H V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SIMOCODE pro V EIP (incl. SIPLUS variants), SIMOCODE pro V PN (incl. SIPLUS variants), SIMOTION C, SIMOTION D (incl. SIPLUS variants), SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants), SIMOTION P V4.4 and V4.5, SIMOTION P V5, SINAMICS DCM w. PN, SINAMICS DCP w. PN, SINAMICS G110M w. PN, SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants), SINAMICS G130 V4.7 w. PN, SINAMICS G130 V4.8 w. PN, SINAMICS G150 V4.7 w. PN, SINAMICS G150 V4.8 w. PN, SINAMICS GH150 V4.7 w. PROFINET, SINAMICS GL150 V4.7 w. PROFINET, SINAMICS GM150 V4.7 w. PROFINET, SINAMICS S110 w. PN, SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants), SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants), SINAMICS S150 V4.7 w. PN, SINAMICS S150 V4.8 w. PN, SINAMICS SL150 V4.7.0 w. PROFINET, SINAMICS SL150 V4.7.4 w. PROFINET, SINAMICS SL150 V4.7.5 w. PROFINET, SINAMICS SM120 V4.7 w. PROFINET, SINAMICS V90 w. PN, SINUMERIK 840D sl, SIRIUS Soft Starter 3RW44 PN. Specially crafted packets sent to port 161/udp could cause a Denial-of-Service condition. The affected devices must be restarted manually. plural Siemens The product contains data processing vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensSIMATICS7-200Smart and others are products of Siemens AG. The Siemens SIMATICS7-200Smart is a programmable logic controller (PLC) for use in small and medium-sized automation systems. SIMATICWinACRTX2010incl is a software controller for automation solutions. A denial of service vulnerability exists in several Siemens products. Attackers can exploit this issue to crash the affected device, denying service to legitimate users. A vulnerability has been identified in SIMATIC S7-200 Smart (All versions < V2.03.01), SIMATIC S7-400 PN V6 (All versions < V6.0.6), SIMATIC S7-400 H V6 (All versions < V6.0.8), SIMATIC S7-400 PN/DP V7 (All versions < V7.0.2), SIMATIC S7-410 V8 (All versions < V8.2.1), SIMATIC S7-300 (All versions < V3.X.16), SIMATIC S7-1200 (All versions < V4.2.3), SIMATIC S7-1500 (All versions < V2.0), SIMATIC S7-1500 Software Controller (All versions < V2.0), SIMATIC WinAC RTX 2010 incl. F (All versions), SIMATIC ET 200AL (All versions), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM155-5 PN BA (All versions < V4.0.2), SIMATIC ET 200MP IM155-5 PN ST (All versions < V4.1), SIMATIC ET 200MP IM155-5 PN HF (All versions < V4.2), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM155-6 PN HF (All versions < V4.2.0), SIMATIC ET 200SP IM155-6 PN HA (All versions < V1.1.0), SIMATIC ET 200SP IM155-6 PN BA (All versions), SIMATIC ET 200SP IM155-6 PN ST (All versions), SIMATIC ET 200SP IM155-6 PN HS (All versions), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5), SIMOTION D (All versions < V5.1 HF1), SIMOTION C (All versions < V5.1 HF1), SIMOTION P V4.4 and V4.5 (All versions < V4.5 HF5), SIMOTION P V5 (All versions < V5.1 HF1), SINAMICS DCM w. PN (All versions < V1.2 HF2), SINAMICS G110M w. PN (All versions < V1.02), SINUMERIK 840D sl (All versions), SIMATIC Compact Field Unit (All versions), SIMATIC PN/PN Coupler (All versions < V4.2.0), SIMOCODE pro V PROFINET (All versions < V2.1.1), SIRIUS Soft Starter 3RW44 PN (All versions), SIMOCODE pro V EIP (All versions < V1.0.2). Siemens SIMATIC S7-1500 CPU, etc. SIMATIC S7-1500 CPU is a CPU (central processing unit) module. SIMATIC S7-1500 is a programmable logic controller. SINUMERIK 840D sl is a set of advanced machine tool numerical control system
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201712-0703", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sinamics s120", "scope": "eq", "trust": 1.9, "vendor": "siemens", "version": null }, { "model": "sinamics s150 v4.8", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "sirius soft starter 3rw44pn", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "sinamics s110pn", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "simatic compact field unit", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "sinamics s150 v4.7", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "sinumerik 840d sl", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "sinamics v90pn", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "simocode pro v profinet", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "simatic pn\\/pn coupler", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-300", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 software controller", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic et 200al", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic et 200ecopn", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic et 200m", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic et 200mp", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic et 200pro", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic et 200s", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "sinamics dcm", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "sinamics dcp", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic et 200sp", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "dk standard ethernet controller", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "sinamics s120", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "sinumerik 840d sl", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic compact field unit", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic pn/pn coupler", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "sirius soft starter 3rw44 pn", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "sinamics g150", "scope": "eq", "trust": 1.3, "vendor": "siemens", "version": null }, { "model": "sinamics g130", "scope": "eq", "trust": 1.3, "vendor": "siemens", "version": null }, { "model": "sinamics dcm", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.03.01" }, { "model": "dk standard ethernet controller", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-400h v6", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.0.8" }, { "model": "simatic et 200sp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic et 200al", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sinamics g110m\\/g120pn", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic s7-1500", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-1500 controller", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic et 200mp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-400pn\\/dp v7", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-400pn v6", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.0.6" }, { "model": "simatic winac rtx f 2010", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic et 200ecopn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic et 200pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "ek-ertec 200pn io", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-300", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simotion p", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "simatic et 200m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sinamics dcp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-410 v8", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "ek-ertec 200p", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.5" }, { "model": "simatic et 200s", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simotion c", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "simotion d", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "ek-ertec 200 pn io", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "ek-ertec 200p p", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-200 smart", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn v6", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn/dp v7", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-400h v6", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-410 v8", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic winac rtx 2010 incl. f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simocode pro v profinet", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simotion c", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simotion d", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simotion p", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics g110m", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics g130", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics g150", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics s110 w. pn", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics s150 v4.7 w. pn", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics s150 v4.8 w. pn", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics v90 w. pn", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-200 smart", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v2.03.01" }, { "model": "simatic s7-400 pn", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v6\u003cv6.0.6" }, { "model": "simatic s7-400 h", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v6" }, { "model": "simatic s7-400 pn/dp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v7" }, { "model": "simatic s7-410", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v8" }, { "model": "simatic winac rtx incl.f", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "2010" }, { "model": "ek-ertec pn io", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "200" }, { "model": "simotion d hf1", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v5.1" }, { "model": "simotion c hf1", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v5.1" }, { "model": "simotion p hf1", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v5.1" }, { "model": "sinamics g110m/g120 w.pn sp9 hf1", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v4.7" }, { "model": "ek-ertec 200p", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v4.5" }, { "model": "sinamics s110 w.pn", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics s150", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.7" }, { "model": "sinamics s150", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v4.8" }, { "model": "sinamics w.pn", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v90" }, { "model": "simocode pro profinet", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v" }, { "model": "sinamics g130 and g150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "softnet profinet io", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sirius soft starter 3rw44 pn", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinumerik 840d sl", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinumerik 840d", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinamics sm150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics sm120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics sl150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7.5" }, { "model": "sinamics sl150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7.4" }, { "model": "sinamics sl150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": null }, { "model": "sinamics s120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinamics gm150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics gl150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics gh150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": null }, { "model": "sinamics dcp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinamics dcm", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simotion", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simocode pro eip", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v1.0.1" }, { "model": "simocode pro eip", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v1.0" }, { "model": "simatic winac rtx", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "20100" }, { "model": "simatic winac rtx f sp2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2010" }, { "model": "simatic winac rtx sp2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2010" }, { "model": "simatic s7-410", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "8" }, { "model": "simatic s7-400 pn", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v60" }, { "model": "simatic s7-400 pn", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-400 h", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v60" }, { "model": "simatic s7-300", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-200", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1.8.3" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1.6" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1.5.0" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-1200", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.1.3" }, { "model": "simatic s7-1200", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.0" }, { "model": "simatic s7-1200", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "3.0.1" }, { "model": "simatic s7-1200", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "3.0.0" }, { "model": "simatic s7-1200", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "3.0" }, { "model": "simatic s7-1200", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2.0.3" }, { "model": "simatic s7-1200", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2.0.2" }, { "model": "simatic et", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2000" }, { "model": "simatic compact field unit", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "profinet io", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1.4.1" }, { "model": "profinet io", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinamics sm120 sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics sl150 sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics gm150 sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics gl150 sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics gh150 sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics g120p", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": null }, { "model": "sinamics g120d", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": null }, { "model": "sinamics g120c", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": null }, { "model": "sinamics g120 update sp9 hf1", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g110m", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simotion p hf1", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "simotion c hf1", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "simocode pro eip", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "v1.0.2" }, { "model": "simatic s7-400 pn", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "v66.0.6" }, { "model": "simatic s7-200 smart", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "2.3.1" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 200", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic winac rtx f 2010", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200al", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200ecopn", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200m", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200mp", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200pro", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200s", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "dk standard ethernet controller", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ek ertec 200p", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400pn v6", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ek ertec 200pn io", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simotion d", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simotion c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simotion p", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics dcm", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics dcp", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g110m g120pn", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g130", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g150", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s110pn", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400h v6", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s120", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s150 v4 7", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s150 v4 8", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics v90pn", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinumerik 840d sl", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic compact field unit", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic pn pn coupler", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simocode pro v profinet", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sirius soft starter 3rw44pn", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400pn dp v7", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 410 v8", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1200", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500 controller", "version": "2.0" } ], "sources": [ { "db": "IVD", "id": "e2df32de-39ab-11e9-b092-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2017-36884" }, { "db": "BID", "id": "101964" }, { "db": "JVNDB", "id": "JVNDB-2017-011798" }, { "db": "NVD", "id": "CVE-2017-12741" }, { "db": "CNNVD", "id": "CNNVD-201711-1105" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.03.01", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400pn_v6_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.0.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400pn_v6:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.0.8", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400pn\\/dp_v7_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400pn\\/dp_v7:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_controller_firmware:2.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_f_2010_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx_f_2010:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.5", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200pn_io_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200pn_io:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simotion_d_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "5.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simotion_d:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simotion_c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "5.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simotion_c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simotion_p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "5.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simotion_p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcp_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m\\/g120pn_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "4.7", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g110m\\/g120pn:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s110pn_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s110pn:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_v4.7_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s150_v4.7:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_v4.8_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s150_v4.8:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_v90pn_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_v90pn:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_compact_field_unit_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_compact_field_unit:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sirius_soft_starter_3rw44pn_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sirius_soft_starter_3rw44pn:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2017-12741" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens ProductCERT reported this vulnerability to NCCIC.", "sources": [ { "db": "CNNVD", "id": "CNNVD-201711-1105" } ], "trust": 0.6 }, "cve": "CVE-2017-12741", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "impactScore": 6.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 7.8, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2017-12741", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2017-36884", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "e2df32de-39ab-11e9-b092-000c29342cb1", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-103294", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2017-12741", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2017-12741", "trust": 1.8, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2017-36884", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201711-1105", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "e2df32de-39ab-11e9-b092-000c29342cb1", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-103294", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "e2df32de-39ab-11e9-b092-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2017-36884" }, { "db": "VULHUB", "id": "VHN-103294" }, { "db": "JVNDB", "id": "JVNDB-2017-011798" }, { "db": "NVD", "id": "CVE-2017-12741" }, { "db": "CNNVD", "id": "CNNVD-201711-1105" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC Compact Field Unit, SIMATIC ET200AL, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-200 SMART, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 H V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SIMOCODE pro V EIP (incl. SIPLUS variants), SIMOCODE pro V PN (incl. SIPLUS variants), SIMOTION C, SIMOTION D (incl. SIPLUS variants), SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants), SIMOTION P V4.4 and V4.5, SIMOTION P V5, SINAMICS DCM w. PN, SINAMICS DCP w. PN, SINAMICS G110M w. PN, SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants), SINAMICS G130 V4.7 w. PN, SINAMICS G130 V4.8 w. PN, SINAMICS G150 V4.7 w. PN, SINAMICS G150 V4.8 w. PN, SINAMICS GH150 V4.7 w. PROFINET, SINAMICS GL150 V4.7 w. PROFINET, SINAMICS GM150 V4.7 w. PROFINET, SINAMICS S110 w. PN, SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants), SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants), SINAMICS S150 V4.7 w. PN, SINAMICS S150 V4.8 w. PN, SINAMICS SL150 V4.7.0 w. PROFINET, SINAMICS SL150 V4.7.4 w. PROFINET, SINAMICS SL150 V4.7.5 w. PROFINET, SINAMICS SM120 V4.7 w. PROFINET, SINAMICS V90 w. PN, SINUMERIK 840D sl, SIRIUS Soft Starter 3RW44 PN. Specially crafted packets sent to port 161/udp could cause a Denial-of-Service condition. The affected devices must be restarted manually. plural Siemens The product contains data processing vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensSIMATICS7-200Smart and others are products of Siemens AG. The Siemens SIMATICS7-200Smart is a programmable logic controller (PLC) for use in small and medium-sized automation systems. SIMATICWinACRTX2010incl is a software controller for automation solutions. A denial of service vulnerability exists in several Siemens products. \nAttackers can exploit this issue to crash the affected device, denying service to legitimate users. A vulnerability has been identified in SIMATIC S7-200 Smart (All versions \u003c V2.03.01), SIMATIC S7-400 PN V6 (All versions \u003c V6.0.6), SIMATIC S7-400 H V6 (All versions \u003c V6.0.8), SIMATIC S7-400 PN/DP V7 (All versions \u003c V7.0.2), SIMATIC S7-410 V8 (All versions \u003c V8.2.1), SIMATIC S7-300 (All versions \u003c V3.X.16), SIMATIC S7-1200 (All versions \u003c V4.2.3), SIMATIC S7-1500 (All versions \u003c V2.0), SIMATIC S7-1500 Software Controller (All versions \u003c V2.0), SIMATIC WinAC RTX 2010 incl. F (All versions), SIMATIC ET 200AL (All versions), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM155-5 PN BA (All versions \u003c V4.0.2), SIMATIC ET 200MP IM155-5 PN ST (All versions \u003c V4.1), SIMATIC ET 200MP IM155-5 PN HF (All versions \u003c V4.2), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM155-6 PN HF (All versions \u003c V4.2.0), SIMATIC ET 200SP IM155-6 PN HA (All versions \u003c V1.1.0), SIMATIC ET 200SP IM155-6 PN BA (All versions), SIMATIC ET 200SP IM155-6 PN ST (All versions), SIMATIC ET 200SP IM155-6 PN HS (All versions), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions \u003c V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions \u003c V4.5), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions \u003c V4.5), SIMOTION D (All versions \u003c V5.1 HF1), SIMOTION C (All versions \u003c V5.1 HF1), SIMOTION P V4.4 and V4.5 (All versions \u003c V4.5 HF5), SIMOTION P V5 (All versions \u003c V5.1 HF1), SINAMICS DCM w. PN (All versions \u003c V1.2 HF2), SINAMICS G110M w. PN (All versions \u003c V1.02), SINUMERIK 840D sl (All versions), SIMATIC Compact Field Unit (All versions), SIMATIC PN/PN Coupler (All versions \u003c V4.2.0), SIMOCODE pro V PROFINET (All versions \u003c V2.1.1), SIRIUS Soft Starter 3RW44 PN (All versions), SIMOCODE pro V EIP (All versions \u003c V1.0.2). Siemens SIMATIC S7-1500 CPU, etc. SIMATIC S7-1500 CPU is a CPU (central processing unit) module. SIMATIC S7-1500 is a programmable logic controller. SINUMERIK 840D sl is a set of advanced machine tool numerical control system", "sources": [ { "db": "NVD", "id": "CVE-2017-12741" }, { "db": "JVNDB", "id": "JVNDB-2017-011798" }, { "db": "CNVD", "id": "CNVD-2017-36884" }, { "db": "BID", "id": "101964" }, { "db": "IVD", "id": "e2df32de-39ab-11e9-b092-000c29342cb1" }, { "db": "VULHUB", "id": "VHN-103294" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2017-12741", "trust": 3.6 }, { "db": "BID", "id": "101964", "trust": 2.6 }, { "db": "ICS CERT", "id": "ICSA-17-339-01", "trust": 2.3 }, { "db": "SIEMENS", "id": "SSA-346262", "trust": 2.0 }, { "db": "SIEMENS", "id": "SSA-546832", "trust": 2.0 }, { "db": "SIEMENS", "id": "SSA-141614", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-18-128-01", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-19-099-01", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-201711-1105", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2017-36884", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2017-011798", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2019.1206", "trust": 0.6 }, { "db": "IVD", "id": "E2DF32DE-39AB-11E9-B092-000C29342CB1", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-103294", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "e2df32de-39ab-11e9-b092-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2017-36884" }, { "db": "VULHUB", "id": "VHN-103294" }, { "db": "BID", "id": "101964" }, { "db": "JVNDB", "id": "JVNDB-2017-011798" }, { "db": "NVD", "id": "CVE-2017-12741" }, { "db": "CNNVD", "id": "CNNVD-201711-1105" } ] }, "id": "VAR-201712-0703", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "e2df32de-39ab-11e9-b092-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2017-36884" }, { "db": "VULHUB", "id": "VHN-103294" } ], "trust": 1.5574432950000001 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 }, { "category": [ "ICS" ], "sub_category": null, "trust": 0.2 } ], "sources": [ { "db": "IVD", "id": "e2df32de-39ab-11e9-b092-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2017-36884" } ] }, "last_update_date": "2023-12-18T12:51:14.227000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-346262", "trust": 0.8, "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-346262.pdf" }, { "title": "Patches for multiple Siemens product denial of service vulnerabilities", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/109849" }, { "title": "Multiple Siemens Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=76771" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-36884" }, { "db": "JVNDB", "id": "JVNDB-2017-011798" }, { "db": "CNNVD", "id": "CNNVD-201711-1105" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.0 }, { "problemtype": "CWE-19", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-103294" }, { "db": "JVNDB", "id": "JVNDB-2017-011798" }, { "db": "NVD", "id": "CVE-2017-12741" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.9, "url": "https://www.securityfocus.com/bid/101964" }, { "trust": 2.3, "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-339-01" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "trust": 1.7, "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-128-01" }, { "trust": 0.9, "url": "http://www.siemens.com/" }, { "trust": 0.9, "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-099-01" }, { "trust": 0.9, "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-346262.pdf" }, { "trust": 0.9, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-546832.txt" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-12741" }, { "trust": 0.8, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-099-01" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-12741" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/78750" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-17-339-01" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-36884" }, { "db": "VULHUB", "id": "VHN-103294" }, { "db": "BID", "id": "101964" }, { "db": "JVNDB", "id": "JVNDB-2017-011798" }, { "db": "NVD", "id": "CVE-2017-12741" }, { "db": "CNNVD", "id": "CNNVD-201711-1105" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "e2df32de-39ab-11e9-b092-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2017-36884" }, { "db": "VULHUB", "id": "VHN-103294" }, { "db": "BID", "id": "101964" }, { "db": "JVNDB", "id": "JVNDB-2017-011798" }, { "db": "NVD", "id": "CVE-2017-12741" }, { "db": "CNNVD", "id": "CNNVD-201711-1105" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2017-12-12T00:00:00", "db": "IVD", "id": "e2df32de-39ab-11e9-b092-000c29342cb1" }, { "date": "2017-12-12T00:00:00", "db": "CNVD", "id": "CNVD-2017-36884" }, { "date": "2017-12-26T00:00:00", "db": "VULHUB", "id": "VHN-103294" }, { "date": "2017-11-23T00:00:00", "db": "BID", "id": "101964" }, { "date": "2018-01-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-011798" }, { "date": "2017-12-26T04:29:13.707000", "db": "NVD", "id": "CVE-2017-12741" }, { "date": "2017-11-28T00:00:00", "db": "CNNVD", "id": "CNNVD-201711-1105" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2017-12-12T00:00:00", "db": "CNVD", "id": "CNVD-2017-36884" }, { "date": "2020-08-14T00:00:00", "db": "VULHUB", "id": "VHN-103294" }, { "date": "2019-04-10T07:00:00", "db": "BID", "id": "101964" }, { "date": "2019-07-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-011798" }, { "date": "2022-02-09T16:15:08.687000", "db": "NVD", "id": "CVE-2017-12741" }, { "date": "2022-02-11T00:00:00", "db": "CNNVD", "id": "CNNVD-201711-1105" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201711-1105" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Siemens Data processing vulnerabilities in products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-011798" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "resource management error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201711-1105" } ], "trust": 0.6 } }
var-202004-0712
Vulnerability from variot
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, KTK ATE530S, SIDOOR ATD430W, SIDOOR ATE530S COATED, SIDOOR ATE531S, SIMATIC ET 200pro IM154-8 PN/DP CPU (6ES7154-8AB01-0AB0), SIMATIC ET 200pro IM154-8F PN/DP CPU (6ES7154-8FB01-0AB0), SIMATIC ET 200pro IM154-8FX PN/DP CPU (6ES7154-8FX00-0AB0), SIMATIC ET 200S IM151-8 PN/DP CPU (6ES7151-8AB01-0AB0), SIMATIC ET 200S IM151-8F PN/DP CPU (6ES7151-8FB01-0AB0), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC ET200AL IM157-1 PN, SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0), SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0), SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0), SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0), SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 MF HF, SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC MICRO-DRIVE PDC, SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0), SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0), SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0), SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0), SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0), SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0), SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0), SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0), SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0), SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0), SIMATIC S7-400 H V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0), SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0), SINAMICS S/G Control Unit w. PROFINET, SIPLUS ET 200S IM151-8 PN/DP CPU (6AG1151-8AB01-7AB0), SIPLUS ET 200S IM151-8F PN/DP CPU (6AG1151-8FB01-2AB0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0), SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0), SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0), SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0), SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0), SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0). The Interniche-based TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service. Several Siemens products contain resource exhaustion vulnerabilities.Service operation interruption (DoS) It may be put into a state. are all products of the German Siemens (Siemens) company. SIMATIC S7-1500 CPU is a CPU (Central Processing Unit) module. SIMATIC S7-1500 is a programmable logic controller. SIMATIC TDC CP51M1 is an industrial Ethernet communication module of the SIMATIC TDC automation system.
Many Siemens products have resource management error vulnerabilities, which can be exploited by attackers to cause denial of service. PROFINET (All versions)
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202004-0712", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": null, "scope": "eq", "trust": 1.6, "vendor": "simatic et200sp im155 6 pn 2 hf", "version": "*" }, { "model": "simatic et 200sp open controller cpu 1515sp pc", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-1500", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "2.0" }, { "model": "simatic et 200sp open controller cpu 1515sp pc2", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "2.0" }, { "model": "ktk ate530s", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "sidoor atd430w", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "sidoor ate530s coated", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "sidoor ate531s", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1517-3 pn\\/dp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-1500 cpu 1511f-1 pn", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic micro-drive pdc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1500 cpu 1518-4 pn\\/dp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic pn\\/pn coupler", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "4.2" }, { "model": "simatic s7-1500 cpu 1513f-1 pn", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-1500 cpu 1517f-3 pn\\/dp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-1500 cpu 1511-1 pn", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic et200sp im155-6 pn\\/2 hf", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "4.2" }, { "model": "simatic et200sp im155-6 pn ha", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1500 cpu 1513-1 pn", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "sidoor ate530s coated", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sidoor ate531s", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sidoor atd430w", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1500 cpu 1516-3 pn\\/dp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "ktk ate530s", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1500 cpu 1515-2 pn", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-1500 cpu 1516f-3 pn\\/dp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic tdc cpu555", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics s\\/g control unit", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et200mp im155-5 pn hf", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "4.2" }, { "model": "simatic s7-1500 cpu 1515f-2 pn", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-1500 cpu 1518f-4 pn\\/dp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic tdc cp51m1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic winac rtx \\ 2010", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et200sp im155-6 mf hf", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-300 cpu", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-400 pn\\/dp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et200sp im155-6 pn hf", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "4.2" }, { "model": "simatic s7-410 cpu", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "ktk ate530s", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic et200sp im155 6 pn hf", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic micro drive pdc", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic pn pn coupler", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic s7 1500 cpu 1511 1 pn", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic s7 1500 cpu 1513 1 pn", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic s7 1500 cpu 1515 2 pn", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic s7 1500 cpu 1516 3 pn dp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic s7 1500 cpu 1517 3 pn dp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "sidoor atd430w", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic s7 1500 cpu 1518 4 pn dp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic s7 1500 cpu 1511f 1 pn", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic s7 1500 cpu 1513f 1 pn", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic s7 1500 cpu 1515f 2 pn", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic s7 1500 cpu 1516f 3 pn dp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic s7 1500 cpu 1517f 3 pn dp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic s7 1500 cpu 1518f 4 pn dp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic s7 1500", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic s7 300 cpu", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic s7 400 pn dp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "sidoor ate530s coated", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic s7 410 cpu", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic tdc cp51m1", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic tdc cpu555", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic winac rtx f 2010", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "sinamics s g control unit", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "sidoor ate531s", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic et 200sp open controller cpu 1515sp pc", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic et 200sp open controller cpu 1515sp pc2", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic et200mp im155 5 pn hf", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic et200sp im155 6 mf hf", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "simatic et200sp im155 6 pn ha", "version": "*" }, { "model": "simatic et 200 sp open controller cpu 1515sp pc", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "2.0" }, { "model": "simatic et 200 sp open controller cpu 1515sp pc2", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "2.0" }, { "model": "simatic et 200mp im 155-5 pn hf", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "4.2" }, { "model": "simatic et200sp im155-6 mf hf", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "4.2" }, { "model": "simatic et200sp im155-6 pn ha", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "4.2" }, { "model": "simatic et200sp im155-6 pn hf", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "4.2" }, { "model": "simatic s7-300", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et200sp im155-6 mf hf", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et200mp im155-5 pn hf", "scope": "gte", "trust": 0.6, "vendor": "siemens", "version": "4.2" }, { "model": "simatic et200sp im155-6 pn hf", "scope": "gte", "trust": 0.6, "vendor": "siemens", "version": "4.2" }, { "model": "simatic pn/pn coupler", "scope": "gte", "trust": 0.6, "vendor": "siemens", "version": "4.2" }, { "model": "simatic s7-1500 software controller", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-410", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic tdc cp51m1", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et200sp im155-6 pn ha", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et200sp im155-6 pn/2 hf", "scope": "gte", "trust": 0.6, "vendor": "siemens", "version": "4.2" }, { "model": "simatic et200sp im155-6 pn/3 hf.simatic micro-drive pdc", "scope": "gte", "trust": 0.6, "vendor": "siemens", "version": "4.2" }, { "model": "simatic micro-drive pdc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn/dp", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic tdc cpu555", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic winac rtx 2010", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics s/g control unit w. profinet", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "IVD", "id": "27a9c9bb-8adf-48d6-b6bd-c1000a913454" }, { "db": "IVD", "id": "53646c4d-c67e-442c-b6e5-e05576895f55" }, { "db": "IVD", "id": "b989cd8a-d784-43d6-b848-6040a850cda1" }, { "db": "IVD", "id": "40b4fa3b-5945-486b-8125-8431896d5661" }, { "db": "CNVD", "id": "CNVD-2020-23035" }, { "db": "JVNDB", "id": "JVNDB-2019-015236" }, { "db": "NVD", "id": "CVE-2019-19300" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ktk_ate530s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ktk_ate530s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sidoor_atd430w_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sidoor_atd430w:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sidoor_ate530s_coated_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sidoor_ate530s_coated:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sidoor_ate531s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sidoor_ate531s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et200mp_im155-5_pn_hf_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "4.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et200mp_im155-5_pn_hf:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et200sp_im155-6_mf_hf_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et200sp_im155-6_mf_hf:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn_ha_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et200sp_im155-6_pn_ha:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn_hf_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "4.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et200sp_im155-6_pn_hf:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn\\/2_hf_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "4.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et200sp_im155-6_pn\\/2_hf:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn\\/2_hf_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "4.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_et200sp_im155-6_pn\\/2_hf:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_micro-drive_pdc_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_micro-drive_pdc:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "4.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_pn_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1_pn:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_pn_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1_pn:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_pn_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2_pn:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_pn_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1_pn:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_pn_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1_pn:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_pn_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2_pn:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:simatic_s7-1500:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp:v7:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-410_cpu_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-410_cpu:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_2010_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s\\/g_control_unit_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s\\/g_control_unit:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2019-19300" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported this vulnerability to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-801" } ], "trust": 0.6 }, "cve": "CVE-2019-19300", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.0, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2019-015236", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2020-23035", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "27a9c9bb-8adf-48d6-b6bd-c1000a913454", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "53646c4d-c67e-442c-b6e5-e05576895f55", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "b989cd8a-d784-43d6-b848-6040a850cda1", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "40b4fa3b-5945-486b-8125-8431896d5661", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" }, { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2019-19300", "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "MEDIUM", "trust": 0.1, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2019-015236", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2019-19300", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2019-19300", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "JVNDB-2019-015236", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2020-23035", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202004-801", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "27a9c9bb-8adf-48d6-b6bd-c1000a913454", "trust": 0.2, "value": "HIGH" }, { "author": "IVD", "id": "53646c4d-c67e-442c-b6e5-e05576895f55", "trust": 0.2, "value": "HIGH" }, { "author": "IVD", "id": "b989cd8a-d784-43d6-b848-6040a850cda1", "trust": 0.2, "value": "HIGH" }, { "author": "IVD", "id": "40b4fa3b-5945-486b-8125-8431896d5661", "trust": 0.2, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2019-19300", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "27a9c9bb-8adf-48d6-b6bd-c1000a913454" }, { "db": "IVD", "id": "53646c4d-c67e-442c-b6e5-e05576895f55" }, { "db": "IVD", "id": "b989cd8a-d784-43d6-b848-6040a850cda1" }, { "db": "IVD", "id": "40b4fa3b-5945-486b-8125-8431896d5661" }, { "db": "CNVD", "id": "CNVD-2020-23035" }, { "db": "VULMON", "id": "CVE-2019-19300" }, { "db": "JVNDB", "id": "JVNDB-2019-015236" }, { "db": "CNNVD", "id": "CNNVD-202004-801" }, { "db": "NVD", "id": "CVE-2019-19300" }, { "db": "NVD", "id": "CVE-2019-19300" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, KTK ATE530S, SIDOOR ATD430W, SIDOOR ATE530S COATED, SIDOOR ATE531S, SIMATIC ET 200pro IM154-8 PN/DP CPU (6ES7154-8AB01-0AB0), SIMATIC ET 200pro IM154-8F PN/DP CPU (6ES7154-8FB01-0AB0), SIMATIC ET 200pro IM154-8FX PN/DP CPU (6ES7154-8FX00-0AB0), SIMATIC ET 200S IM151-8 PN/DP CPU (6ES7151-8AB01-0AB0), SIMATIC ET 200S IM151-8F PN/DP CPU (6ES7151-8FB01-0AB0), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC ET200AL IM157-1 PN, SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0), SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0), SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0), SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0), SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 MF HF, SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC MICRO-DRIVE PDC, SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0), SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0), SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0), SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0), SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0), SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0), SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0), SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0), SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0), SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0), SIMATIC S7-400 H V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0), SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0), SINAMICS S/G Control Unit w. PROFINET, SIPLUS ET 200S IM151-8 PN/DP CPU (6AG1151-8AB01-7AB0), SIPLUS ET 200S IM151-8F PN/DP CPU (6AG1151-8FB01-2AB0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0), SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0), SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0), SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0), SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0), SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0). The Interniche-based TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service. Several Siemens products contain resource exhaustion vulnerabilities.Service operation interruption (DoS) It may be put into a state. are all products of the German Siemens (Siemens) company. SIMATIC S7-1500 CPU is a CPU (Central Processing Unit) module. SIMATIC S7-1500 is a programmable logic controller. SIMATIC TDC CP51M1 is an industrial Ethernet communication module of the SIMATIC TDC automation system. \n\r\n\r\nMany Siemens products have resource management error vulnerabilities, which can be exploited by attackers to cause denial of service. PROFINET (All versions)", "sources": [ { "db": "NVD", "id": "CVE-2019-19300" }, { "db": "JVNDB", "id": "JVNDB-2019-015236" }, { "db": "CNVD", "id": "CNVD-2020-23035" }, { "db": "IVD", "id": "27a9c9bb-8adf-48d6-b6bd-c1000a913454" }, { "db": "IVD", "id": "53646c4d-c67e-442c-b6e5-e05576895f55" }, { "db": "IVD", "id": "b989cd8a-d784-43d6-b848-6040a850cda1" }, { "db": "IVD", "id": "40b4fa3b-5945-486b-8125-8431896d5661" }, { "db": "VULMON", "id": "CVE-2019-19300" } ], "trust": 2.97 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-19300", "trust": 3.9 }, { "db": "ICS CERT", "id": "ICSA-20-105-08", "trust": 2.1 }, { "db": "SIEMENS", "id": "SSA-593272", "trust": 1.7 }, { "db": "CNVD", "id": "CNVD-2020-23035", "trust": 1.4 }, { "db": "CNNVD", "id": "CNNVD-202004-801", "trust": 1.4 }, { "db": "JVN", "id": "JVNVU95499848", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2019-015236", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2020.1345", "trust": 0.6 }, { "db": "IVD", "id": "27A9C9BB-8ADF-48D6-B6BD-C1000A913454", "trust": 0.2 }, { "db": "IVD", "id": "53646C4D-C67E-442C-B6E5-E05576895F55", "trust": 0.2 }, { "db": "IVD", "id": "B989CD8A-D784-43D6-B848-6040A850CDA1", "trust": 0.2 }, { "db": "IVD", "id": "40B4FA3B-5945-486B-8125-8431896D5661", "trust": 0.2 }, { "db": "VULMON", "id": "CVE-2019-19300", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "27a9c9bb-8adf-48d6-b6bd-c1000a913454" }, { "db": "IVD", "id": "53646c4d-c67e-442c-b6e5-e05576895f55" }, { "db": "IVD", "id": "b989cd8a-d784-43d6-b848-6040a850cda1" }, { "db": "IVD", "id": "40b4fa3b-5945-486b-8125-8431896d5661" }, { "db": "CNVD", "id": "CNVD-2020-23035" }, { "db": "VULMON", "id": "CVE-2019-19300" }, { "db": "JVNDB", "id": "JVNDB-2019-015236" }, { "db": "CNNVD", "id": "CNNVD-202004-801" }, { "db": "NVD", "id": "CVE-2019-19300" } ] }, "id": "VAR-202004-0712", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "27a9c9bb-8adf-48d6-b6bd-c1000a913454" }, { "db": "IVD", "id": "53646c4d-c67e-442c-b6e5-e05576895f55" }, { "db": "IVD", "id": "b989cd8a-d784-43d6-b848-6040a850cda1" }, { "db": "IVD", "id": "40b4fa3b-5945-486b-8125-8431896d5661" }, { "db": "CNVD", "id": "CNVD-2020-23035" } ], "trust": 2.112842044347826 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 }, { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "IVD", "id": "27a9c9bb-8adf-48d6-b6bd-c1000a913454" }, { "db": "IVD", "id": "53646c4d-c67e-442c-b6e5-e05576895f55" }, { "db": "IVD", "id": "b989cd8a-d784-43d6-b848-6040a850cda1" }, { "db": "IVD", "id": "40b4fa3b-5945-486b-8125-8431896d5661" }, { "db": "CNVD", "id": "CNVD-2020-23035" } ] }, "last_update_date": "2024-05-14T22:36:22.729000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-593272", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-593272.pdf" }, { "title": "Patch for Multiple Siemens product resource management error vulnerabilities (CNVD-2020-23035)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/214037" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=b6bdf7c5a64c5efcddeb45b5831983cf" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-23035" }, { "db": "VULMON", "id": "CVE-2019-19300" }, { "db": "JVNDB", "id": "JVNDB-2019-015236" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015236" }, { "db": "NVD", "id": "CVE-2019-19300" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.7, "url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-08" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-593272.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-19300" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-593272.html" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-19300" }, { "trust": 0.8, "url": "http://jvn.jp/vu/jvnvu95499848/index.html" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.1345/" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-105-08" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/simatic-denial-of-service-via-interniche-segmentsmack-32022" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/400.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-105-08" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-23035" }, { "db": "VULMON", "id": "CVE-2019-19300" }, { "db": "JVNDB", "id": "JVNDB-2019-015236" }, { "db": "CNNVD", "id": "CNNVD-202004-801" }, { "db": "NVD", "id": "CVE-2019-19300" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "27a9c9bb-8adf-48d6-b6bd-c1000a913454" }, { "db": "IVD", "id": "53646c4d-c67e-442c-b6e5-e05576895f55" }, { "db": "IVD", "id": "b989cd8a-d784-43d6-b848-6040a850cda1" }, { "db": "IVD", "id": "40b4fa3b-5945-486b-8125-8431896d5661" }, { "db": "CNVD", "id": "CNVD-2020-23035" }, { "db": "VULMON", "id": "CVE-2019-19300" }, { "db": "JVNDB", "id": "JVNDB-2019-015236" }, { "db": "CNNVD", "id": "CNNVD-202004-801" }, { "db": "NVD", "id": "CVE-2019-19300" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-04-14T00:00:00", "db": "IVD", "id": "27a9c9bb-8adf-48d6-b6bd-c1000a913454" }, { "date": "2020-04-14T00:00:00", "db": "IVD", "id": "53646c4d-c67e-442c-b6e5-e05576895f55" }, { "date": "2020-04-14T00:00:00", "db": "IVD", "id": "b989cd8a-d784-43d6-b848-6040a850cda1" }, { "date": "2020-04-14T00:00:00", "db": "IVD", "id": "40b4fa3b-5945-486b-8125-8431896d5661" }, { "date": "2020-04-16T00:00:00", "db": "CNVD", "id": "CNVD-2020-23035" }, { "date": "2020-04-14T00:00:00", "db": "VULMON", "id": "CVE-2019-19300" }, { "date": "2020-04-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-015236" }, { "date": "2020-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-801" }, { "date": "2020-04-14T20:15:14.903000", "db": "NVD", "id": "CVE-2019-19300" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-04-16T00:00:00", "db": "CNVD", "id": "CNVD-2020-23035" }, { "date": "2022-06-14T00:00:00", "db": "VULMON", "id": "CVE-2019-19300" }, { "date": "2020-04-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-015236" }, { "date": "2023-02-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-801" }, { "date": "2024-05-14T16:15:16.220000", "db": "NVD", "id": "CVE-2019-19300" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-801" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Variety Siemens Product resource management error vulnerability ( CNVD-2020-23035 )", "sources": [ { "db": "IVD", "id": "27a9c9bb-8adf-48d6-b6bd-c1000a913454" }, { "db": "IVD", "id": "53646c4d-c67e-442c-b6e5-e05576895f55" }, { "db": "IVD", "id": "b989cd8a-d784-43d6-b848-6040a850cda1" }, { "db": "IVD", "id": "40b4fa3b-5945-486b-8125-8431896d5661" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Resource management error", "sources": [ { "db": "IVD", "id": "27a9c9bb-8adf-48d6-b6bd-c1000a913454" }, { "db": "IVD", "id": "53646c4d-c67e-442c-b6e5-e05576895f55" }, { "db": "IVD", "id": "b989cd8a-d784-43d6-b848-6040a850cda1" }, { "db": "IVD", "id": "40b4fa3b-5945-486b-8125-8431896d5661" }, { "db": "CNNVD", "id": "CNNVD-202004-801" } ], "trust": 1.4 } }
cve-2022-25622
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T04:42:50.341Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CFU DIQ", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU PA", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 MF HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/2 HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/3 HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V5.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V5.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V5.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DI 16x24VDC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DI 8x24VDC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.3", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/MF Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= 4.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 412-2 PN V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.10", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V10.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.10", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM", "vendor": "Siemens", "versions": [ { "lessThan": "V1.5 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M", "vendor": "Siemens", "versions": [ { "lessThan": "V4.7.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G115D", "vendor": "Siemens", "versions": [ { "lessThan": "V4.7.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.7 SP14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.3.13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.3.13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2 SP3 HF13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.3.13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S210 (6SL5...)", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2 SP3 HF18", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS V90", "vendor": "Siemens", "versions": [ { "lessThan": "V1.04.04", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS HCS4200 CIM4210", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS HCS4200 CIM4210C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS HCS4300 CIM4310", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= 4.2" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:04:01.924Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-25622", "datePublished": "2022-04-12T00:00:00", "dateReserved": "2022-02-21T00:00:00", "dateUpdated": "2024-08-03T04:42:50.341Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-10936
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "dk_standard_ethernet_controller_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:ek-ertec_200_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ek-ertec_200_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:ek-ertec_200p_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ek-ertec_200p_firmware", "vendor": "siemens", "versions": [ { "lessThan": "4.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cfu_pa", "vendor": "siemens", "versions": [ { "lessThan": "v1.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et200ecopn_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et200ecopn_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et200s_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et200s_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200al_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200m_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200mp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v4.3.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200pro_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200s_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200sp_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_hmi_comfort_outdoor_panels", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0", "vendor": "siemens", "versions": [ { "lessThan": "v4.2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_profinet_driver", "vendor": "siemens", "versions": [ { "lessThan": "v2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_314_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_315-2_dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_315f-2_dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_315f-2_dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_317-2_dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_pn\\/dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_317-2_pn\\/dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_319-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_319-3_pn\\/dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_cpu_412-2_pn", "vendor": "siemens", "versions": [ { "lessThan": "v7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\/dp:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_cpu_414-3_pn\\/dp", "vendor": "siemens", "versions": [ { "lessThan": "v7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\/dp:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_cpu_416-3_pn\\/dp", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "v7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-400_h_v6_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_h_v6_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "v6.0.9", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v6_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_pn\\/dp_v6_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-410_cpu_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-410_cpu_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v8.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-1200_cpu", "vendor": "siemens", "versions": [ { "lessThan": "v4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-1500_cpu", "vendor": "siemens", "versions": [ { "lessThan": "v2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-1500_controller", "vendor": "siemens", "versions": [ { "lessThan": "v2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_tdc_cp51m1_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_tdc_cpu555_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_winac_rtx_2010", "vendor": "siemens", "versions": [ { "lessThan": "v2010_sp3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_winac_rtx_\\(f\\)_2010", "vendor": "siemens", "versions": [ { "lessThan": "v2010_sp3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_dcm", "vendor": "siemens", "versions": [ { "lessThan": "v1.5_hf1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_dcp", "vendor": "siemens", "versions": [ { "lessThan": "v1.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_g110m", "vendor": "siemens", "versions": [ { "lessThan": "v4.7_sp10_hf5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_g120", "vendor": "siemens", "versions": [ { "lessThan": "v4.7_sp10_hf5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_g130", "vendor": "siemens", "versions": [ { "lessThan": "v4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_g150", "vendor": "siemens", "versions": [ { "lessThan": "v4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_gh150", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_gl150", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_gm150", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_s110", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_s120", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_sl150", "vendor": "siemens", "versions": [ { "lessThan": "v4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_sl150", "vendor": "siemens", "versions": [ { "lessThan": "v4.7_hf33", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_sm120", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinumerik_828d", "vendor": "siemens", "versions": [ { "lessThan": "v4.8_sp5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinumerik_840d_sl", "vendor": "siemens", "versions": [ { "lessThan": "v4.8_sp6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:siplus_s7-300_cpu_314:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "siplus_s7-300_cpu_314", "vendor": "siemens", "versions": [ { "lessThan": "v3.3.17", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2019-10936", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-09T14:36:59.481395Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-09T15:59:12.602Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-04T22:40:15.253Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.6 Patch 01" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU PA", "vendor": "Siemens", "versions": [ { "lessThan": "V1.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/2 HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/3 HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Outdoor Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI KTP Mobile Panels", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PROFINET Driver", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 412-2 PN V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.9", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.5 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M V4.7 PN Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP10 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP10 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 4.8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 4.8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110 Control Unit", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 4.8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF33" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP5" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP6" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices improperly handle large amounts of specially crafted UDP packets.\r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:03:55.957Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-10936", "datePublished": "2019-10-10T00:00:00", "dateReserved": "2019-04-08T00:00:00", "dateUpdated": "2024-08-04T22:40:15.253Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-19300
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:16:46.943Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-593272.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-593272.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "KTK ATE530S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIDOOR ATD430W", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIDOOR ATE530S COATED", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIDOOR ATE531S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 MF HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/2 HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/3 HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V5.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V5.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V5.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DI 16x24VDC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DI 8x24VDC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.3", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MICRO-DRIVE PDC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/MF Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V4.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6\u00a0and below\u00a0CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S/G Control Unit w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V4.2" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, KTK ATE530S, SIDOOR ATD430W, SIDOOR ATE530S COATED, SIDOOR ATE531S, SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0), SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0), SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0), SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0), SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0), SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants), SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0), SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0), SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0), SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0), SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0), SIMATIC MICRO-DRIVE PDC, SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0), SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0), SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0), SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0), SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0), SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0), SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0), SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0), SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0), SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0), SIMATIC S7-400 H V6\u00a0and below\u00a0CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0), SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0), SINAMICS S/G Control Unit w. PROFINET, SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0), SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0), SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0), SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0), SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0), SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0), SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0), SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0). The Interniche-based TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:03:59.957Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-593272.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-593272.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-19300", "datePublished": "2020-04-14T00:00:00", "dateReserved": "2019-11-26T00:00:00", "dateUpdated": "2024-08-05T02:16:46.943Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }