14 vulnerabilities found for Sage 1430 by Schneider Electric

CVE-2024-37040 (GCVE-0-2024-37040)

Vulnerability from cvelistv5 – Published: 2024-06-12 16:56 – Updated: 2024-08-02 03:43
VLAI?
Summary
CWE-120: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’) vulnerability exists that could allow a user with access to the device’s web interface to cause a fault on the device when sending a malformed HTTP request.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
Impacted products
Vendor Product Version
Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_4400",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37040",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T18:27:09.666436Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T18:34:05.093Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:43:50.968Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1410",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1430",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1450",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 2400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 3030 Magnum",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 4400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\n\n\n\n\n\n\n\n\n\nCWE-120: Buffer Copy without Checking Size of Input (\u2018Classic Buffer Overflow\u2019) vulnerability\nexists that could allow a user with access to the device\u2019s web interface to cause a fault on the\ndevice when sending a malformed HTTP request.\n\n\n\n\n\n\n\n\n\n\n\n"
            }
          ],
          "value": "CWE-120: Buffer Copy without Checking Size of Input (\u2018Classic Buffer Overflow\u2019) vulnerability\nexists that could allow a user with access to the device\u2019s web interface to cause a fault on the\ndevice when sending a malformed HTTP request."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T16:56:06.117Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-37040",
    "datePublished": "2024-06-12T16:56:06.117Z",
    "dateReserved": "2024-05-31T06:52:05.762Z",
    "dateUpdated": "2024-08-02T03:43:50.968Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37039 (GCVE-0-2024-37039)

Vulnerability from cvelistv5 – Published: 2024-06-12 16:54 – Updated: 2024-08-02 03:43
VLAI?
Summary
CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request.
CWE
Assigner
Impacted products
Vendor Product Version
Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_4400",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37039",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T18:24:08.466465Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T18:33:50.964Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:43:50.886Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1410",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1430",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1450",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 2400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 3030 Magnum",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 4400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\n\n\n\n\n\n\n\nCWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the\ndevice when an attacker sends a specially crafted HTTP request.\n\n\n\n\n\n\n\n\n\n"
            }
          ],
          "value": "CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the\ndevice when an attacker sends a specially crafted HTTP request."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-252",
              "description": "CWE-252 Unchecked Return Value",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T16:54:23.117Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-37039",
    "datePublished": "2024-06-12T16:54:23.117Z",
    "dateReserved": "2024-05-31T06:52:05.762Z",
    "dateUpdated": "2024-08-02T03:43:50.886Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37038 (GCVE-0-2024-37038)

Vulnerability from cvelistv5 – Published: 2024-06-12 16:51 – Updated: 2024-08-02 03:43
VLAI?
Summary
CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests.
CWE
  • CWE-276 - Incorrect Default Permissions
Assigner
Impacted products
Vendor Product Version
Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:schneider_electric:sage_4400:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_4400",
            "vendor": "schneider_electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:schneider_electric:sage_1430:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_1430",
            "vendor": "schneider_electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:schneider_electric:sage_2400:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_2400",
            "vendor": "schneider_electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:schneider_electric:sage_3030m:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_3030m",
            "vendor": "schneider_electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:schneider_electric:sage_1410:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_1410",
            "vendor": "schneider_electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:schneider_electric:sage_1450:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_1450",
            "vendor": "schneider_electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37038",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T17:44:53.062764Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T17:54:11.618Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:43:50.738Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1410",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1430",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1450",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 2400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 3030 Magnum",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 4400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\n\n\n\n\n\nCWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated\nuser with access to the device\u2019s web interface to perform unauthorized file and firmware\nuploads when crafting custom web requests.\n\n\n\n\n\n\n\n"
            }
          ],
          "value": "CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated\nuser with access to the device\u2019s web interface to perform unauthorized file and firmware\nuploads when crafting custom web requests."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276 Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T16:51:55.800Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-37038",
    "datePublished": "2024-06-12T16:51:55.800Z",
    "dateReserved": "2024-05-31T06:52:05.762Z",
    "dateUpdated": "2024-08-02T03:43:50.738Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37037 (GCVE-0-2024-37037)

Vulnerability from cvelistv5 – Published: 2024-06-12 16:50 – Updated: 2024-08-02 03:43
VLAI?
Summary
CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’) vulnerability exists that could allow an authenticated user with access to the device’s web interface to corrupt files and impact device functionality when sending a crafted HTTP request.
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
Impacted products
Vendor Product Version
Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_4400",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37037",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T18:28:51.967522Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T18:33:38.098Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:43:50.902Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1410",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1430",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1450",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 2400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 3030 Magnum",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 4400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\n\n\n\nCWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u2018Path\nTraversal\u2019) vulnerability exists that could allow an authenticated user with access to the device\u2019s\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\nrequest.\n\n\n\n\n\n"
            }
          ],
          "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u2018Path\nTraversal\u2019) vulnerability exists that could allow an authenticated user with access to the device\u2019s\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\nrequest."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T16:50:09.159Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-37037",
    "datePublished": "2024-06-12T16:50:09.159Z",
    "dateReserved": "2024-05-31T06:52:05.762Z",
    "dateUpdated": "2024-08-02T03:43:50.902Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37036 (GCVE-0-2024-37036)

Vulnerability from cvelistv5 – Published: 2024-06-12 16:48 – Updated: 2024-08-02 03:43
VLAI?
Summary
CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set.
CWE
Assigner
Impacted products
Vendor Product Version
Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:schneider_electric:sage_1410_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:schneider_electric:sage_1430_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:schneider_electric:sage_1450_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:schneider_electric:sage_2400_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:schneider_electric:sage_3030_magnum_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:schneider_electric:sage_4400_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sage_4400_firmware",
            "vendor": "schneider_electric",
            "versions": [
              {
                "lessThanOrEqual": "C3414-500-S02K5_P8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37036",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T17:43:17.841310Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T17:57:45.916Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:43:50.996Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1410",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1430",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1450",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 2400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 3030 Magnum",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 4400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\n\nCWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass\nwhen sending a malformed POST request and particular configuration parameters are set.\n\n\n\n"
            }
          ],
          "value": "CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass\nwhen sending a malformed POST request and particular configuration parameters are set."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T16:48:09.163Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-37036",
    "datePublished": "2024-06-12T16:48:09.163Z",
    "dateReserved": "2024-05-31T06:52:05.762Z",
    "dateUpdated": "2024-08-02T03:43:50.996Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-5560 (GCVE-0-2024-5560)

Vulnerability from cvelistv5 – Published: 2024-06-12 16:45 – Updated: 2024-08-01 21:18
VLAI?
Summary
CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the device’s web interface when an attacker sends a specially crafted HTTP request.
CWE
Assigner
Impacted products
Vendor Product Version
Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_4400",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5560",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T18:30:24.462387Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T18:32:10.472Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:18:06.538Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1410",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1430",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1450",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 2400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 3030 Magnum",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 4400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nCWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\ndevice\u2019s web interface when an attacker sends a specially crafted HTTP request.\n\n"
            }
          ],
          "value": "CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\ndevice\u2019s web interface when an attacker sends a specially crafted HTTP request."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T16:45:56.256Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-5560",
    "datePublished": "2024-06-12T16:45:56.256Z",
    "dateReserved": "2024-05-31T06:58:55.638Z",
    "dateUpdated": "2024-08-01T21:18:06.538Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37040 (GCVE-0-2024-37040)

Vulnerability from nvd – Published: 2024-06-12 16:56 – Updated: 2024-08-02 03:43
VLAI?
Summary
CWE-120: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’) vulnerability exists that could allow a user with access to the device’s web interface to cause a fault on the device when sending a malformed HTTP request.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
Impacted products
Vendor Product Version
Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_4400",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37040",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T18:27:09.666436Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T18:34:05.093Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:43:50.968Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1410",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1430",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1450",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 2400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 3030 Magnum",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 4400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\n\n\n\n\n\n\n\n\n\nCWE-120: Buffer Copy without Checking Size of Input (\u2018Classic Buffer Overflow\u2019) vulnerability\nexists that could allow a user with access to the device\u2019s web interface to cause a fault on the\ndevice when sending a malformed HTTP request.\n\n\n\n\n\n\n\n\n\n\n\n"
            }
          ],
          "value": "CWE-120: Buffer Copy without Checking Size of Input (\u2018Classic Buffer Overflow\u2019) vulnerability\nexists that could allow a user with access to the device\u2019s web interface to cause a fault on the\ndevice when sending a malformed HTTP request."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T16:56:06.117Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-37040",
    "datePublished": "2024-06-12T16:56:06.117Z",
    "dateReserved": "2024-05-31T06:52:05.762Z",
    "dateUpdated": "2024-08-02T03:43:50.968Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37039 (GCVE-0-2024-37039)

Vulnerability from nvd – Published: 2024-06-12 16:54 – Updated: 2024-08-02 03:43
VLAI?
Summary
CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request.
CWE
Assigner
Impacted products
Vendor Product Version
Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_4400",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37039",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T18:24:08.466465Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T18:33:50.964Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:43:50.886Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1410",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1430",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1450",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 2400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 3030 Magnum",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 4400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\n\n\n\n\n\n\n\nCWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the\ndevice when an attacker sends a specially crafted HTTP request.\n\n\n\n\n\n\n\n\n\n"
            }
          ],
          "value": "CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the\ndevice when an attacker sends a specially crafted HTTP request."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-252",
              "description": "CWE-252 Unchecked Return Value",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T16:54:23.117Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-37039",
    "datePublished": "2024-06-12T16:54:23.117Z",
    "dateReserved": "2024-05-31T06:52:05.762Z",
    "dateUpdated": "2024-08-02T03:43:50.886Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37038 (GCVE-0-2024-37038)

Vulnerability from nvd – Published: 2024-06-12 16:51 – Updated: 2024-08-02 03:43
VLAI?
Summary
CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests.
CWE
  • CWE-276 - Incorrect Default Permissions
Assigner
Impacted products
Vendor Product Version
Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:schneider_electric:sage_4400:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_4400",
            "vendor": "schneider_electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:schneider_electric:sage_1430:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_1430",
            "vendor": "schneider_electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:schneider_electric:sage_2400:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_2400",
            "vendor": "schneider_electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:schneider_electric:sage_3030m:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_3030m",
            "vendor": "schneider_electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:schneider_electric:sage_1410:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_1410",
            "vendor": "schneider_electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:schneider_electric:sage_1450:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_1450",
            "vendor": "schneider_electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37038",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T17:44:53.062764Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T17:54:11.618Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:43:50.738Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1410",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1430",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1450",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 2400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 3030 Magnum",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 4400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\n\n\n\n\n\nCWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated\nuser with access to the device\u2019s web interface to perform unauthorized file and firmware\nuploads when crafting custom web requests.\n\n\n\n\n\n\n\n"
            }
          ],
          "value": "CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated\nuser with access to the device\u2019s web interface to perform unauthorized file and firmware\nuploads when crafting custom web requests."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276 Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T16:51:55.800Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-37038",
    "datePublished": "2024-06-12T16:51:55.800Z",
    "dateReserved": "2024-05-31T06:52:05.762Z",
    "dateUpdated": "2024-08-02T03:43:50.738Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37037 (GCVE-0-2024-37037)

Vulnerability from nvd – Published: 2024-06-12 16:50 – Updated: 2024-08-02 03:43
VLAI?
Summary
CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’) vulnerability exists that could allow an authenticated user with access to the device’s web interface to corrupt files and impact device functionality when sending a crafted HTTP request.
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
Impacted products
Vendor Product Version
Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_4400",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37037",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T18:28:51.967522Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T18:33:38.098Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:43:50.902Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1410",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1430",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1450",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 2400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 3030 Magnum",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 4400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\n\n\n\nCWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u2018Path\nTraversal\u2019) vulnerability exists that could allow an authenticated user with access to the device\u2019s\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\nrequest.\n\n\n\n\n\n"
            }
          ],
          "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u2018Path\nTraversal\u2019) vulnerability exists that could allow an authenticated user with access to the device\u2019s\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\nrequest."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T16:50:09.159Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-37037",
    "datePublished": "2024-06-12T16:50:09.159Z",
    "dateReserved": "2024-05-31T06:52:05.762Z",
    "dateUpdated": "2024-08-02T03:43:50.902Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-37036 (GCVE-0-2024-37036)

Vulnerability from nvd – Published: 2024-06-12 16:48 – Updated: 2024-08-02 03:43
VLAI?
Summary
CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set.
CWE
Assigner
Impacted products
Vendor Product Version
Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:schneider_electric:sage_1410_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:schneider_electric:sage_1430_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:schneider_electric:sage_1450_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:schneider_electric:sage_2400_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:schneider_electric:sage_3030_magnum_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:schneider_electric:sage_4400_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sage_4400_firmware",
            "vendor": "schneider_electric",
            "versions": [
              {
                "lessThanOrEqual": "C3414-500-S02K5_P8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37036",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T17:43:17.841310Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T17:57:45.916Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:43:50.996Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1410",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1430",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1450",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 2400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 3030 Magnum",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 4400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\n\nCWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass\nwhen sending a malformed POST request and particular configuration parameters are set.\n\n\n\n"
            }
          ],
          "value": "CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass\nwhen sending a malformed POST request and particular configuration parameters are set."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T16:48:09.163Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-37036",
    "datePublished": "2024-06-12T16:48:09.163Z",
    "dateReserved": "2024-05-31T06:52:05.762Z",
    "dateUpdated": "2024-08-02T03:43:50.996Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-5560 (GCVE-0-2024-5560)

Vulnerability from nvd – Published: 2024-06-12 16:45 – Updated: 2024-08-01 21:18
VLAI?
Summary
CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the device’s web interface when an attacker sends a specially crafted HTTP request.
CWE
Assigner
Impacted products
Vendor Product Version
Schneider Electric Sage 1410 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1430 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 1450 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 2400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 3030 Magnum Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
    Schneider Electric Sage 4400 Affected: Versions C3414-500-S02K5_P8 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
              "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "sage_4400",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "c3414-500-s02k5_p8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5560",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T18:30:24.462387Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T18:32:10.472Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:18:06.538Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1410",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1430",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 1450",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 2400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 3030 Magnum",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Sage 4400",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nCWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\ndevice\u2019s web interface when an attacker sends a specially crafted HTTP request.\n\n"
            }
          ],
          "value": "CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the\ndevice\u2019s web interface when an attacker sends a specially crafted HTTP request."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T16:45:56.256Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-5560",
    "datePublished": "2024-06-12T16:45:56.256Z",
    "dateReserved": "2024-05-31T06:58:55.638Z",
    "dateUpdated": "2024-08-01T21:18:06.538Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CERTFR-2024-AVI-0476

Vulnerability from certfr_avis - Published: - Updated:

De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une élévation de privilèges, un déni de service à distance et une atteinte à la confidentialité des données.

Solutions

Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).

Impacted products
Vendor Product Description
Schneider Electric Sage 2400 Sage 2400 avec un microgiciel antérieur à C3414-500-S02K5_P9
Schneider Electric Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 toutes versions
Schneider Electric Sage 1450 Sage 1450 avec un microgiciel antérieur à C3414-500-S02K5_P9
Schneider Electric Sage 1430 Sage 1430 avec un microgiciel antérieur à C3414-500-S02K5_P9
Schneider Electric Sage 3030 Magnum Sage 3030 Magnum avec un microgiciel antérieur à C3414-500-S02K5_P9
Schneider Electric Sage 1410 Sage 1410 avec un microgiciel antérieur à C3414-500-S02K5_P9
Schneider Electric EVlink Home Smart EVlink Home Smart versions 2.0.4.1.2_131 et 2.0.3.8.2_128 antérieures à 2.0.5.0.0_134
Schneider Electric Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110
Schneider Electric Modicon M340 Modicon M340 toutes versions
Schneider Electric PowerLogic P5 PowerLogic P5 versions antérieures à 02.501.101
Schneider Electric Sage 4400 Sage 4400 avec un microgiciel antérieur à C3414-500-S02K5_P9
Schneider Electric N/A SpaceLogic AS-P et SpaceLogic AS-B versions antérieures à 6.0.1 ou versions 5.0.3 et 4.0.5 sans le dernier correctif de sécurité
Schneider Electric Network module, Modicon M340, Modbus/TCP BMXNOE0100 Network module, Modicon M340 et Modbus/TCP BMXNOE0100 toutes versions

Show details on source website

{
  "$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
  "affected_systems": [
    {
      "description": "Sage 2400 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
      "product": {
        "name": "Sage 2400",
        "vendor": {
          "name": "Schneider Electric",
          "scada": true
        }
      }
    },
    {
      "description": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110 toutes versions",
      "product": {
        "name": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110",
        "vendor": {
          "name": "Schneider Electric",
          "scada": true
        }
      }
    },
    {
      "description": "Sage 1450 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
      "product": {
        "name": "Sage 1450",
        "vendor": {
          "name": "Schneider Electric",
          "scada": true
        }
      }
    },
    {
      "description": "Sage 1430 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
      "product": {
        "name": "Sage 1430",
        "vendor": {
          "name": "Schneider Electric",
          "scada": true
        }
      }
    },
    {
      "description": "Sage 3030 Magnum avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
      "product": {
        "name": "Sage 3030 Magnum",
        "vendor": {
          "name": "Schneider Electric",
          "scada": true
        }
      }
    },
    {
      "description": "Sage 1410 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
      "product": {
        "name": "Sage 1410",
        "vendor": {
          "name": "Schneider Electric",
          "scada": true
        }
      }
    },
    {
      "description": "EVlink Home Smart versions 2.0.4.1.2_131 et 2.0.3.8.2_128 ant\u00e9rieures \u00e0 2.0.5.0.0_134",
      "product": {
        "name": "EVlink Home Smart",
        "vendor": {
          "name": "Schneider Electric",
          "scada": true
        }
      }
    },
    {
      "description": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110",
      "product": {
        "name": "Network module, Modicon M340 et Ethernet TCP/IP BMXNOE0110",
        "vendor": {
          "name": "Schneider Electric",
          "scada": true
        }
      }
    },
    {
      "description": "Modicon M340 toutes versions",
      "product": {
        "name": "Modicon M340",
        "vendor": {
          "name": "Schneider Electric",
          "scada": true
        }
      }
    },
    {
      "description": "PowerLogic P5 versions ant\u00e9rieures \u00e0 02.501.101",
      "product": {
        "name": "PowerLogic P5",
        "vendor": {
          "name": "Schneider Electric",
          "scada": true
        }
      }
    },
    {
      "description": "Sage 4400 avec un microgiciel ant\u00e9rieur \u00e0 C3414-500-S02K5_P9",
      "product": {
        "name": "Sage 4400",
        "vendor": {
          "name": "Schneider Electric",
          "scada": true
        }
      }
    },
    {
      "description": "SpaceLogic AS-P et SpaceLogic AS-B versions ant\u00e9rieures \u00e0 6.0.1 ou versions 5.0.3 et 4.0.5 sans le dernier correctif de s\u00e9curit\u00e9",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Schneider Electric",
          "scada": true
        }
      }
    },
    {
      "description": "Network module, Modicon M340 et Modbus/TCP BMXNOE0100 toutes versions",
      "product": {
        "name": "Network module, Modicon M340, Modbus/TCP BMXNOE0100",
        "vendor": {
          "name": "Schneider Electric",
          "scada": true
        }
      }
    }
  ],
  "affected_systems_content": "",
  "content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
  "cves": [
    {
      "name": "CVE-2024-5557",
      "url": "https://www.cve.org/CVERecord?id=CVE-2024-5557"
    },
    {
      "name": "CVE-2024-37039",
      "url": "https://www.cve.org/CVERecord?id=CVE-2024-37039"
    },
    {
      "name": "CVE-2024-5558",
      "url": "https://www.cve.org/CVERecord?id=CVE-2024-5558"
    },
    {
      "name": "CVE-2024-5056",
      "url": "https://www.cve.org/CVERecord?id=CVE-2024-5056"
    },
    {
      "name": "CVE-2024-37037",
      "url": "https://www.cve.org/CVERecord?id=CVE-2024-37037"
    },
    {
      "name": "CVE-2024-5559",
      "url": "https://www.cve.org/CVERecord?id=CVE-2024-5559"
    },
    {
      "name": "CVE-2024-5313",
      "url": "https://www.cve.org/CVERecord?id=CVE-2024-5313"
    },
    {
      "name": "CVE-2024-37038",
      "url": "https://www.cve.org/CVERecord?id=CVE-2024-37038"
    },
    {
      "name": "CVE-2024-37040",
      "url": "https://www.cve.org/CVERecord?id=CVE-2024-37040"
    },
    {
      "name": "CVE-2024-5560",
      "url": "https://www.cve.org/CVERecord?id=CVE-2024-5560"
    },
    {
      "name": "CVE-2024-37036",
      "url": "https://www.cve.org/CVERecord?id=CVE-2024-37036"
    }
  ],
  "links": [],
  "reference": "CERTFR-2024-AVI-0476",
  "revisions": [
    {
      "description": "Version initiale",
      "revision_date": "2024-06-11T00:00:00.000000"
    },
    {
      "description": "Ajout des identifiants CVE.",
      "revision_date": "2024-06-14T00:00:00.000000"
    }
  ],
  "risks": [
    {
      "description": "D\u00e9ni de service \u00e0 distance"
    },
    {
      "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
    },
    {
      "description": "Contournement de la politique de s\u00e9curit\u00e9"
    },
    {
      "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
    },
    {
      "description": "\u00c9l\u00e9vation de privil\u00e8ges"
    }
  ],
  "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Schneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une \u00e9l\u00e9vation de privil\u00e8ges, un d\u00e9ni de service \u00e0 distance et une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.",
  "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
  "vendor_advisories": [
    {
      "published_at": "2024-06-11",
      "title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-02",
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-02.pdf"
    },
    {
      "published_at": "2024-06-11",
      "title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-01",
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-01.pdf"
    },
    {
      "published_at": "2024-06-11",
      "title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-03",
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
    },
    {
      "published_at": "2024-06-11",
      "title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-05",
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-05.pdf"
    },
    {
      "published_at": "2024-06-11",
      "title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-163-04",
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
    }
  ]
}