12 vulnerabilities found for Server Firmware by IBM
CVE-2026-18848 (GCVE-0-2026-18848)
Vulnerability from nvd – Published: 2026-08-19 18:44 – Updated: 2026-08-20 15:26
VLAI
EPSS
VEX
Title
Power System Cross-Site Request Forgery (CSRF)
Summary
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An attacker who can lure a logged-in ASMI administrator to visit a crafted web page can, under specific conditions, silently perform administrative actions on the FSP on behalf of that administrator, resulting in a confidentiality, integrity, and availability impact to the managed system.
Severity
8.3 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-20 15:18 UTC
CWE
- CWE-352 - Cross-Site Request Forgery (CSRF)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7283897 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Power Systems Firmware |
Affected:
FW1120.00
Affected: FW1110.00 , ≤ FW1110.30 (semver) Affected: FW1060.00 , ≤ FW1060.80 (semver) Affected: FW950.00 , ≤ FW950.H2 (semver) cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-18848",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-20T15:18:19.542093Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-20T15:26:35.167Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
],
"product": "Power Systems Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An attacker who can lure a logged-in ASMI administrator to visit a crafted web page can, under specific conditions, silently perform administrative actions on the FSP on behalf of that administrator, resulting in a confidentiality, integrity, and availability impact to the managed system.\u003c/p\u003e"
}
],
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An attacker who can lure a logged-in ASMI administrator to visit a crafted web page can, under specific conditions, silently perform administrative actions on the FSP on behalf of that administrator, resulting in a confidentiality, integrity, and availability impact to the managed system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352 Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T18:59:38.344Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7283897"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCustomers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"nofollow\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\n\n\n\nPower 9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/"
}
],
"title": "Power System Cross-Site Request Forgery (CSRF)"
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2026-18848",
"datePublished": "2026-08-19T18:44:50.279Z",
"dateReserved": "2026-08-04T15:29:17.255Z",
"dateUpdated": "2026-08-20T15:26:35.167Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-18681 (GCVE-0-2026-18681)
Vulnerability from nvd – Published: 2026-08-19 18:36 – Updated: 2026-08-19 19:59
VLAI
EPSS
VEX
Title
This Power System Buffer Overflow
Summary
IBM Server Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP firmware update process. An attacker with authenticated administrator-level access to the FSP can, under specific conditions, execute arbitrary code, resulting in a confidentiality, integrity, and availability impact.
Severity
6.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-19 19:20 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7283899 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Server Firmware |
Affected:
FW1120.00
Affected: FW1110.00 , ≤ FW1110.30 (semver) Affected: FW1060.00 , ≤ FW1060.80 (semver) Affected: FW950.00 , ≤ FW950.H2 (semver) cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-18681",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-19T19:20:47.264675Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T19:59:43.874Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
],
"product": "Server Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Server Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP firmware update process. An attacker with authenticated administrator-level access to the FSP can, under specific conditions, execute arbitrary code, resulting in a confidentiality, integrity, and availability impact.\u003c/p\u003e"
}
],
"value": "IBM Server Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP firmware update process. An attacker with authenticated administrator-level access to the FSP can, under specific conditions, execute arbitrary code, resulting in a confidentiality, integrity, and availability impact."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T18:36:15.970Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7283899"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCustomers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"nofollow\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\n\n\n\nPower 9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/"
}
],
"title": "This Power System Buffer Overflow",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eProtect administrator access to the FSP.\u00a0 Install firmware images only from trusted sources.\u00a0 Validate the firmware image\u0027s integrity as described in the firmware \"Release Notes\" section \"Firmware Information and Description\" before installing it.\u003c/p\u003e"
}
],
"value": "Protect administrator access to the FSP.\u00a0 Install firmware images only from trusted sources.\u00a0 Validate the firmware image\u0027s integrity as described in the firmware \"Release Notes\" section \"Firmware Information and Description\" before installing it."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2026-18681",
"datePublished": "2026-08-19T18:36:15.970Z",
"dateReserved": "2026-08-03T15:34:34.383Z",
"dateUpdated": "2026-08-19T19:59:43.874Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-16938 (GCVE-0-2026-16938)
Vulnerability from nvd – Published: 2026-08-19 18:48 – Updated: 2026-08-20 15:26
VLAI
EPSS
VEX
Title
Power System Missing Authorization
Summary
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in access controls over privileged system configuration operations on the FSP. An attacker with authenticated administrator-level access to the FSP can place the managed system into a non-production operational mode, allowing certain system components to be disabled. This condition persists across FSP resets and requires explicit operator intervention — clearing the affected configuration — to restore normal operation. Successful exploitation results in an availability impact to the managed system.
Severity
6.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-20 15:18 UTC
CWE
- CWE-862 - Missing Authorization
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7283896 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Power Systems Firmware |
Affected:
FW1120.00
Affected: FW1110.00 , ≤ FW1110.30 (semver) Affected: FW1060.00 , ≤ FW1060.80 (semver) Affected: FW950.00 , ≤ FW950.H2 (semver) cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-16938",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-20T15:18:49.285398Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-20T15:26:35.014Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
],
"product": "Power Systems Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in access controls over privileged system configuration operations on the FSP. An attacker with authenticated administrator-level access to the FSP can place the managed system into a non-production operational mode, allowing certain system components to be disabled. This condition persists across FSP resets and requires explicit operator intervention \u2014 clearing the affected configuration \u2014 to restore normal operation. Successful exploitation results in an availability impact to the managed system.\u003c/p\u003e"
}
],
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in access controls over privileged system configuration operations on the FSP. An attacker with authenticated administrator-level access to the FSP can place the managed system into a non-production operational mode, allowing certain system components to be disabled. This condition persists across FSP resets and requires explicit operator intervention \u2014 clearing the affected configuration \u2014 to restore normal operation. Successful exploitation results in an availability impact to the managed system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862 Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T18:59:17.561Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7283896"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCustomers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW950.H3(950_230), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"nofollow\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134), or newer to remediate this vulnerability.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nCustomers with the products below should install FW950.H3(950_230), or newer to remediate this vulnerability.\n\n\n\nPower9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/"
}
],
"title": "Power System Missing Authorization",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eProtect access to the FSP\u0027s administrative interface.\u003c/p\u003e"
}
],
"value": "Protect access to the FSP\u0027s administrative interface."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2026-16938",
"datePublished": "2026-08-19T18:48:32.835Z",
"dateReserved": "2026-07-24T07:44:31.605Z",
"dateUpdated": "2026-08-20T15:26:35.014Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-16835 (GCVE-0-2026-16835)
Vulnerability from nvd – Published: 2026-08-19 18:52 – Updated: 2026-08-22 03:56
VLAI
EPSS
VEX
Title
Power System Improper Certificate Validation
Summary
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An unauthenticated attacker on the management network can bypass authentication and perform any administrative operation on the managed system, including control of partition power state, configuration, and console access across all hosted partitions, resulting in a confidentiality, integrity, and availability impact to the managed system.
Severity
9.6 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-21 00:00 UTC
CWE
- CWE-295 - Improper Certificate Validation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7283894 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Power Systems Firmware |
Affected:
FW1120.00
Affected: FW1110.00 , ≤ FW1110.30 (semver) Affected: FW1060.00 , ≤ FW1060.80 (semver) Affected: FW950.00 , ≤ FW950.H2 (semver) cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-16835",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-21T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-22T03:56:03.546Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
],
"product": "Power Systems Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An unauthenticated attacker on the management network can bypass authentication and perform any administrative operation on the managed system, including control of partition power state, configuration, and console access across all hosted partitions, resulting in a confidentiality, integrity, and availability impact to the managed system.\u003c/p\u003e"
}
],
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An unauthenticated attacker on the management network can bypass authentication and perform any administrative operation on the managed system, including control of partition power state, configuration, and console access across all hosted partitions, resulting in a confidentiality, integrity, and availability impact to the managed system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-295",
"description": "CWE-295 Improper Certificate Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T18:58:32.634Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7283894"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM strongly recommends customers with the products below install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability as soon as possible.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eIBM strongly recommends customers with the products below install FW1060.81(1060_184) or newer to remediate this vulnerability as soon as possible.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eIBM strongly recommends customers with the products below install FW950.H3(950_230) or newer to remediate this vulnerability as soon as possible.\u003c/p\u003e\u003cp\u003ePower 9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"noopener noreferrer nofollow\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "IBM strongly recommends customers with the products below install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability as soon as possible.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nIBM strongly recommends customers with the products below install FW1060.81(1060_184) or newer to remediate this vulnerability as soon as possible.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nIBM strongly recommends customers with the products below install FW950.H3(950_230) or newer to remediate this vulnerability as soon as possible.\n\n\n\nPower 9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/"
}
],
"title": "Power System Improper Certificate Validation",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eProtect access to the FSP\u0027s network interface.\u003c/p\u003e"
}
],
"value": "Protect access to the FSP\u0027s network interface."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2026-16835",
"datePublished": "2026-08-19T18:52:26.786Z",
"dateReserved": "2026-07-24T02:49:39.986Z",
"dateUpdated": "2026-08-22T03:56:03.546Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-16832 (GCVE-0-2026-16832)
Vulnerability from nvd – Published: 2026-08-19 18:49 – Updated: 2026-08-22 03:56
VLAI
EPSS
VEX
Title
Power System Buffer Overflow
Summary
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An attacker with authenticated HMC administrator access can execute arbitrary code on the service processor, giving full control over the managed system, resulting in a confidentiality, integrity, and availability impact.
Severity
8.4 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-21 00:00 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7283895 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Power Systems Firmware |
Affected:
FW1120.00
Affected: FW1110.00 , ≤ FW1110.30 (semver) Affected: FW1060.00 , ≤ FW1060.80 (semver) Affected: FW950.00 , ≤ FW950.H2 (semver) cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-16832",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-21T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-22T03:56:07.011Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
],
"product": "Power Systems Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An attacker with authenticated HMC administrator access can execute arbitrary code on the service processor, giving full control over the managed system, resulting in a confidentiality, integrity, and availability impact.\u003c/p\u003e"
}
],
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An attacker with authenticated HMC administrator access can execute arbitrary code on the service processor, giving full control over the managed system, resulting in a confidentiality, integrity, and availability impact."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T18:58:53.948Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7283895"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCustomers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW950.H3(950_230), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"nofollow\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134), or newer to remediate this vulnerability.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nCustomers with the products below should install FW950.H3(950_230), or newer to remediate this vulnerability.\n\n\n\nPower9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/"
}
],
"title": "Power System Buffer Overflow",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eProtect access to the FSP\u0027s network interface.\u003c/p\u003e"
}
],
"value": "Protect access to the FSP\u0027s network interface."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2026-16832",
"datePublished": "2026-08-19T18:49:27.791Z",
"dateReserved": "2026-07-24T02:37:40.718Z",
"dateUpdated": "2026-08-22T03:56:07.011Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-16828 (GCVE-0-2026-16828)
Vulnerability from nvd – Published: 2026-08-19 18:43 – Updated: 2026-08-21 16:14
VLAI
EPSS
VEX
Title
Power System Out-of-bounds Read
Summary
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact.
Severity
7.6 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-21 16:08 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7283898 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Power Systems Firmware |
Affected:
FW1120.00
Affected: FW1110.00 , ≤ FW1110.30 (semver) Affected: FW1060.00 , ≤ FW1060.80 (semver) Affected: FW950.00 , ≤ FW950.H2 (semver) cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-16828",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-21T16:08:23.424581Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-21T16:14:39.868Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
],
"product": "Power Systems Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact.\u003c/p\u003e"
}
],
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T18:59:57.704Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7283898"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCustomers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"nofollow\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\n\n\n\nPower 9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/"
}
],
"title": "Power System Out-of-bounds Read",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eProtect access to the FSP\u0027s network interface.\u003c/p\u003e"
}
],
"value": "Protect access to the FSP\u0027s network interface."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2026-16828",
"datePublished": "2026-08-19T18:43:41.541Z",
"dateReserved": "2026-07-24T02:25:57.107Z",
"dateUpdated": "2026-08-21T16:14:39.868Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-16835 (GCVE-0-2026-16835)
Vulnerability from cvelistv5 – Published: 2026-08-19 18:52 – Updated: 2026-08-22 03:56
VLAI
EPSS
VEX
Title
Power System Improper Certificate Validation
Summary
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An unauthenticated attacker on the management network can bypass authentication and perform any administrative operation on the managed system, including control of partition power state, configuration, and console access across all hosted partitions, resulting in a confidentiality, integrity, and availability impact to the managed system.
Severity
9.6 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-21 00:00 UTC
CWE
- CWE-295 - Improper Certificate Validation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7283894 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Power Systems Firmware |
Affected:
FW1120.00
Affected: FW1110.00 , ≤ FW1110.30 (semver) Affected: FW1060.00 , ≤ FW1060.80 (semver) Affected: FW950.00 , ≤ FW950.H2 (semver) cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-16835",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-21T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-22T03:56:03.546Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
],
"product": "Power Systems Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An unauthenticated attacker on the management network can bypass authentication and perform any administrative operation on the managed system, including control of partition power state, configuration, and console access across all hosted partitions, resulting in a confidentiality, integrity, and availability impact to the managed system.\u003c/p\u003e"
}
],
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An unauthenticated attacker on the management network can bypass authentication and perform any administrative operation on the managed system, including control of partition power state, configuration, and console access across all hosted partitions, resulting in a confidentiality, integrity, and availability impact to the managed system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-295",
"description": "CWE-295 Improper Certificate Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T18:58:32.634Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7283894"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM strongly recommends customers with the products below install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability as soon as possible.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eIBM strongly recommends customers with the products below install FW1060.81(1060_184) or newer to remediate this vulnerability as soon as possible.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eIBM strongly recommends customers with the products below install FW950.H3(950_230) or newer to remediate this vulnerability as soon as possible.\u003c/p\u003e\u003cp\u003ePower 9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"noopener noreferrer nofollow\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "IBM strongly recommends customers with the products below install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability as soon as possible.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nIBM strongly recommends customers with the products below install FW1060.81(1060_184) or newer to remediate this vulnerability as soon as possible.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nIBM strongly recommends customers with the products below install FW950.H3(950_230) or newer to remediate this vulnerability as soon as possible.\n\n\n\nPower 9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/"
}
],
"title": "Power System Improper Certificate Validation",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eProtect access to the FSP\u0027s network interface.\u003c/p\u003e"
}
],
"value": "Protect access to the FSP\u0027s network interface."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2026-16835",
"datePublished": "2026-08-19T18:52:26.786Z",
"dateReserved": "2026-07-24T02:49:39.986Z",
"dateUpdated": "2026-08-22T03:56:03.546Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-16832 (GCVE-0-2026-16832)
Vulnerability from cvelistv5 – Published: 2026-08-19 18:49 – Updated: 2026-08-22 03:56
VLAI
EPSS
VEX
Title
Power System Buffer Overflow
Summary
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An attacker with authenticated HMC administrator access can execute arbitrary code on the service processor, giving full control over the managed system, resulting in a confidentiality, integrity, and availability impact.
Severity
8.4 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-21 00:00 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7283895 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Power Systems Firmware |
Affected:
FW1120.00
Affected: FW1110.00 , ≤ FW1110.30 (semver) Affected: FW1060.00 , ≤ FW1060.80 (semver) Affected: FW950.00 , ≤ FW950.H2 (semver) cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-16832",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-21T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-22T03:56:07.011Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
],
"product": "Power Systems Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An attacker with authenticated HMC administrator access can execute arbitrary code on the service processor, giving full control over the managed system, resulting in a confidentiality, integrity, and availability impact.\u003c/p\u003e"
}
],
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An attacker with authenticated HMC administrator access can execute arbitrary code on the service processor, giving full control over the managed system, resulting in a confidentiality, integrity, and availability impact."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T18:58:53.948Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7283895"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCustomers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW950.H3(950_230), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"nofollow\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134), or newer to remediate this vulnerability.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nCustomers with the products below should install FW950.H3(950_230), or newer to remediate this vulnerability.\n\n\n\nPower9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/"
}
],
"title": "Power System Buffer Overflow",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eProtect access to the FSP\u0027s network interface.\u003c/p\u003e"
}
],
"value": "Protect access to the FSP\u0027s network interface."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2026-16832",
"datePublished": "2026-08-19T18:49:27.791Z",
"dateReserved": "2026-07-24T02:37:40.718Z",
"dateUpdated": "2026-08-22T03:56:07.011Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-16938 (GCVE-0-2026-16938)
Vulnerability from cvelistv5 – Published: 2026-08-19 18:48 – Updated: 2026-08-20 15:26
VLAI
EPSS
VEX
Title
Power System Missing Authorization
Summary
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in access controls over privileged system configuration operations on the FSP. An attacker with authenticated administrator-level access to the FSP can place the managed system into a non-production operational mode, allowing certain system components to be disabled. This condition persists across FSP resets and requires explicit operator intervention — clearing the affected configuration — to restore normal operation. Successful exploitation results in an availability impact to the managed system.
Severity
6.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-20 15:18 UTC
CWE
- CWE-862 - Missing Authorization
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7283896 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Power Systems Firmware |
Affected:
FW1120.00
Affected: FW1110.00 , ≤ FW1110.30 (semver) Affected: FW1060.00 , ≤ FW1060.80 (semver) Affected: FW950.00 , ≤ FW950.H2 (semver) cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-16938",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-20T15:18:49.285398Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-20T15:26:35.014Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
],
"product": "Power Systems Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in access controls over privileged system configuration operations on the FSP. An attacker with authenticated administrator-level access to the FSP can place the managed system into a non-production operational mode, allowing certain system components to be disabled. This condition persists across FSP resets and requires explicit operator intervention \u2014 clearing the affected configuration \u2014 to restore normal operation. Successful exploitation results in an availability impact to the managed system.\u003c/p\u003e"
}
],
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in access controls over privileged system configuration operations on the FSP. An attacker with authenticated administrator-level access to the FSP can place the managed system into a non-production operational mode, allowing certain system components to be disabled. This condition persists across FSP resets and requires explicit operator intervention \u2014 clearing the affected configuration \u2014 to restore normal operation. Successful exploitation results in an availability impact to the managed system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862 Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T18:59:17.561Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7283896"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCustomers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW950.H3(950_230), or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"nofollow\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134), or newer to remediate this vulnerability.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nCustomers with the products below should install FW950.H3(950_230), or newer to remediate this vulnerability.\n\n\n\nPower9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/"
}
],
"title": "Power System Missing Authorization",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eProtect access to the FSP\u0027s administrative interface.\u003c/p\u003e"
}
],
"value": "Protect access to the FSP\u0027s administrative interface."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2026-16938",
"datePublished": "2026-08-19T18:48:32.835Z",
"dateReserved": "2026-07-24T07:44:31.605Z",
"dateUpdated": "2026-08-20T15:26:35.014Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-18848 (GCVE-0-2026-18848)
Vulnerability from cvelistv5 – Published: 2026-08-19 18:44 – Updated: 2026-08-20 15:26
VLAI
EPSS
VEX
Title
Power System Cross-Site Request Forgery (CSRF)
Summary
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An attacker who can lure a logged-in ASMI administrator to visit a crafted web page can, under specific conditions, silently perform administrative actions on the FSP on behalf of that administrator, resulting in a confidentiality, integrity, and availability impact to the managed system.
Severity
8.3 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-20 15:18 UTC
CWE
- CWE-352 - Cross-Site Request Forgery (CSRF)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7283897 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Power Systems Firmware |
Affected:
FW1120.00
Affected: FW1110.00 , ≤ FW1110.30 (semver) Affected: FW1060.00 , ≤ FW1060.80 (semver) Affected: FW950.00 , ≤ FW950.H2 (semver) cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-18848",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-20T15:18:19.542093Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-20T15:26:35.167Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
],
"product": "Power Systems Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An attacker who can lure a logged-in ASMI administrator to visit a crafted web page can, under specific conditions, silently perform administrative actions on the FSP on behalf of that administrator, resulting in a confidentiality, integrity, and availability impact to the managed system.\u003c/p\u003e"
}
],
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An attacker who can lure a logged-in ASMI administrator to visit a crafted web page can, under specific conditions, silently perform administrative actions on the FSP on behalf of that administrator, resulting in a confidentiality, integrity, and availability impact to the managed system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352 Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T18:59:38.344Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7283897"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCustomers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"nofollow\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\n\n\n\nPower 9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/"
}
],
"title": "Power System Cross-Site Request Forgery (CSRF)"
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2026-18848",
"datePublished": "2026-08-19T18:44:50.279Z",
"dateReserved": "2026-08-04T15:29:17.255Z",
"dateUpdated": "2026-08-20T15:26:35.167Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-16828 (GCVE-0-2026-16828)
Vulnerability from cvelistv5 – Published: 2026-08-19 18:43 – Updated: 2026-08-21 16:14
VLAI
EPSS
VEX
Title
Power System Out-of-bounds Read
Summary
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact.
Severity
7.6 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-21 16:08 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7283898 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Power Systems Firmware |
Affected:
FW1120.00
Affected: FW1110.00 , ≤ FW1110.30 (semver) Affected: FW1060.00 , ≤ FW1060.80 (semver) Affected: FW950.00 , ≤ FW950.H2 (semver) cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-16828",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-21T16:08:23.424581Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-21T16:14:39.868Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
],
"product": "Power Systems Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact.\u003c/p\u003e"
}
],
"value": "IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T18:59:57.704Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7283898"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCustomers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"nofollow\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\n\n\n\nPower 9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/"
}
],
"title": "Power System Out-of-bounds Read",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eProtect access to the FSP\u0027s network interface.\u003c/p\u003e"
}
],
"value": "Protect access to the FSP\u0027s network interface."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2026-16828",
"datePublished": "2026-08-19T18:43:41.541Z",
"dateReserved": "2026-07-24T02:25:57.107Z",
"dateUpdated": "2026-08-21T16:14:39.868Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-18681 (GCVE-0-2026-18681)
Vulnerability from cvelistv5 – Published: 2026-08-19 18:36 – Updated: 2026-08-19 19:59
VLAI
EPSS
VEX
Title
This Power System Buffer Overflow
Summary
IBM Server Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP firmware update process. An attacker with authenticated administrator-level access to the FSP can, under specific conditions, execute arbitrary code, resulting in a confidentiality, integrity, and availability impact.
Severity
6.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-19 19:20 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7283899 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Server Firmware |
Affected:
FW1120.00
Affected: FW1110.00 , ≤ FW1110.30 (semver) Affected: FW1060.00 , ≤ FW1060.80 (semver) Affected: FW950.00 , ≤ FW950.H2 (semver) cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-18681",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-19T19:20:47.264675Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T19:59:43.874Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*"
],
"product": "Server Firmware",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "FW1120.00"
},
{
"lessThanOrEqual": "FW1110.30",
"status": "affected",
"version": "FW1110.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.80",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW950.H2",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Server Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP firmware update process. An attacker with authenticated administrator-level access to the FSP can, under specific conditions, execute arbitrary code, resulting in a confidentiality, integrity, and availability impact.\u003c/p\u003e"
}
],
"value": "IBM Server Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP firmware update process. An attacker with authenticated administrator-level access to the FSP can, under specific conditions, execute arbitrary code, resulting in a confidentiality, integrity, and availability impact."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-19T18:36:15.970Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7283899"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCustomers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 11\u003cbr/\u003e1) IBM Power System E1180 (9080-HEU)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 10\u003cbr/\u003e1) IBM Power System E1080 (9080-HEX)\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\u003c/p\u003e\u003cp\u003ePower 9\u003cbr/\u003e1) IBM Power System S922 (9009-22G)\u003cbr/\u003e2) IBM Power System H922 (9223-22S)\u003cbr/\u003e3) IBM Power System S914 (9009-41G)\u003cbr/\u003e4) IBM Power System S924 (9009-42G)\u003cbr/\u003e5) IBM Power System H924 (9223-42S)\u003cbr/\u003e6) IBM Power System E950 (9040-MR9)\u003cbr/\u003e7) IBM Power System E980 (9080-M9S)\u003c/p\u003e\u003cp\u003eThe images mentioned above can be located at IBM Fix Central : \u003ca href=\"https://www.ibm.com/support/fixcentral/\" rel=\"nofollow\"\u003ehttps://www.ibm.com/support/fixcentral/\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability.\n\n\n\nPower 11\n1) IBM Power System E1180 (9080-HEU)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability.\n\n\n\nPower 10\n1) IBM Power System E1080 (9080-HEX)\n\n\n\nCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\n\n\n\nPower 9\n1) IBM Power System S922 (9009-22G)\n2) IBM Power System H922 (9223-22S)\n3) IBM Power System S914 (9009-41G)\n4) IBM Power System S924 (9009-42G)\n5) IBM Power System H924 (9223-42S)\n6) IBM Power System E950 (9040-MR9)\n7) IBM Power System E980 (9080-M9S)\n\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/"
}
],
"title": "This Power System Buffer Overflow",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eProtect administrator access to the FSP.\u00a0 Install firmware images only from trusted sources.\u00a0 Validate the firmware image\u0027s integrity as described in the firmware \"Release Notes\" section \"Firmware Information and Description\" before installing it.\u003c/p\u003e"
}
],
"value": "Protect administrator access to the FSP.\u00a0 Install firmware images only from trusted sources.\u00a0 Validate the firmware image\u0027s integrity as described in the firmware \"Release Notes\" section \"Firmware Information and Description\" before installing it."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2026-18681",
"datePublished": "2026-08-19T18:36:15.970Z",
"dateReserved": "2026-08-03T15:34:34.383Z",
"dateUpdated": "2026-08-19T19:59:43.874Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}