GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration
Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    10 vulnerabilities found for System Monitoring by Acer

    CVE-2026-50610 (GCVE-0-2026-50610)

    Vulnerability from nvd – Published: 2026-09-17 08:26 – Updated: 2026-09-17 12:18
    VLAI
    Title
    Improper Access control Vulnerability in NitroSense and PredatorSense Software
    Summary
    A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense due to insufficient access controls in a privileged service. An authenticated local user may be able to access the service and perform unauthorized registry modifications, potentially resulting in local privilege escalation.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-17 12:16 UTC
    CWE
    • CWE-284 - Improper Access Control
    References
    Impacted products
    Vendor Product Version
    Acer System Monitoring Affected: * , ≤ 1.0.19.2 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50610",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-17T12:16:15.601033Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-17T12:18:12.672Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "System Monitoring",
              "vendor": "Acer",
              "versions": [
                {
                  "lessThanOrEqual": "1.0.19.2",
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Cassius GARAT"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense due to insufficient access controls in a privileged service. An authenticated local user may be able to access the service and perform unauthorized registry modifications, potentially resulting in local privilege escalation."
                }
              ],
              "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense due to insufficient access controls in a privileged service. An authenticated local user may be able to access the service and perform unauthorized registry modifications, potentially resulting in local privilege escalation."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233: Privilege Escalation"
                }
              ]
            },
            {
              "capecId": "CAPEC-180",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-180: Exploiting Incorrectly Configured Access Control Security Levels"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-17T08:26:21.362Z",
            "orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
            "shortName": "Acer"
          },
          "references": [
            {
              "url": "https://community.acer.com/en/kb/articles/19877"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "Update to one of the following versions or later:\n\n  *  NitroSense v5.2.84\n  *  PredatorSense v5.2.109"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Improper Access control Vulnerability in NitroSense and PredatorSense Software",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
        "assignerShortName": "Acer",
        "cveId": "CVE-2026-50610",
        "datePublished": "2026-09-17T08:26:21.362Z",
        "dateReserved": "2026-06-05T07:22:32.054Z",
        "dateUpdated": "2026-09-17T12:18:12.672Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50609 (GCVE-0-2026-50609)

    Vulnerability from nvd – Published: 2026-09-17 08:21 – Updated: 2026-09-17 12:24
    VLAI
    Title
    Unauthorized Registry Modification Vulnerability in NitroSense and PredatorSense Software
    Summary
    A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-17 12:23 UTC
    CWE
    • CWE-284 - Improper Access Control
    References
    Impacted products
    Vendor Product Version
    Acer System Monitoring Affected: * , ≤ 1.0.19.2 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50609",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-17T12:23:07.250428Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-17T12:24:11.273Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "System Monitoring",
              "vendor": "Acer",
              "versions": [
                {
                  "lessThanOrEqual": "1.0.19.2",
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Cassius GARAT"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system."
                }
              ],
              "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-180",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels"
                }
              ]
            },
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-17T08:21:29.786Z",
            "orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
            "shortName": "Acer"
          },
          "references": [
            {
              "url": "https://community.acer.com/en/kb/articles/19876"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "Update to one of the following versions or later:\n\n  *  NitroSense v5.2.84\n  *  PredatorSense v5.2.109"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unauthorized Registry Modification Vulnerability in NitroSense and PredatorSense Software",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
        "assignerShortName": "Acer",
        "cveId": "CVE-2026-50609",
        "datePublished": "2026-09-17T08:21:29.786Z",
        "dateReserved": "2026-06-05T07:22:32.054Z",
        "dateUpdated": "2026-09-17T12:24:11.273Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50608 (GCVE-0-2026-50608)

    Vulnerability from nvd – Published: 2026-09-17 08:15 – Updated: 2026-09-17 12:25
    VLAI
    Title
    Authentication Vulnerability in NitroSense and PredatorSense Software
    Summary
    A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The WebSocket handshake process does not properly require authentication before allowing connections to the service. Under certain circumstances, unauthorized access to service functionality may be possible.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-17 12:25 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    References
    Impacted products
    Vendor Product Version
    Acer System Monitoring Affected: * , ≤ 1.0.19.2 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50608",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-17T12:25:32.773472Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-17T12:25:51.670Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "System Monitoring",
              "vendor": "Acer",
              "versions": [
                {
                  "lessThanOrEqual": "1.0.19.2",
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Ayush Choudhary"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The WebSocket handshake process does not properly require authentication before allowing connections to the service. Under certain circumstances, unauthorized access to service functionality may be possible."
                }
              ],
              "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The WebSocket handshake process does not properly require authentication before allowing connections to the service. Under certain circumstances, unauthorized access to service functionality may be possible."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 1.2,
                "baseSeverity": "LOW",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:U",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-17T08:15:17.327Z",
            "orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
            "shortName": "Acer"
          },
          "references": [
            {
              "url": "https://community.acer.com/en/kb/articles/19875"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "Update to one of the following versions or later:\n\n  *  NitroSense v5.2.84\n  *  PredatorSense v5.2.109"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Authentication Vulnerability in NitroSense and PredatorSense Software",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
        "assignerShortName": "Acer",
        "cveId": "CVE-2026-50608",
        "datePublished": "2026-09-17T08:15:17.327Z",
        "dateReserved": "2026-06-05T07:22:32.054Z",
        "dateUpdated": "2026-09-17T12:25:51.670Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50607 (GCVE-0-2026-50607)

    Vulnerability from nvd – Published: 2026-09-17 08:05 – Updated: 2026-09-17 12:26
    VLAI
    Title
    WebSocket Exposure Vulnerability in NitroSense and PredatorSense Software
    Summary
    A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. A WebSocket service was configured to listen on all network interfaces, which may expose the service to unintended network access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-17 12:26 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Acer System Monitoring Affected: * , ≤ 1.0.19.2 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50607",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-17T12:26:05.665465Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-17T12:26:18.604Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "System Monitoring",
              "vendor": "Acer",
              "versions": [
                {
                  "lessThanOrEqual": "1.0.19.2",
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Tolga Cohce"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. A WebSocket service was configured to listen on all network interfaces, which may expose the service to unintended network access."
                }
              ],
              "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. A WebSocket service was configured to listen on all network interfaces, which may expose the service to unintended network access."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-118",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-118: Collect and Analyze Information"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:U",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-668",
                  "description": "CWE-668 All-Interface Binding",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-17T08:22:19.514Z",
            "orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
            "shortName": "Acer"
          },
          "references": [
            {
              "url": "https://community.acer.com/en/kb/articles/19879"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "WebSocket Exposure Vulnerability in NitroSense and PredatorSense Software",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
        "assignerShortName": "Acer",
        "cveId": "CVE-2026-50607",
        "datePublished": "2026-09-17T08:05:44.472Z",
        "dateReserved": "2026-06-05T07:22:32.054Z",
        "dateUpdated": "2026-09-17T12:26:18.604Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50606 (GCVE-0-2026-50606)

    Vulnerability from nvd – Published: 2026-09-17 07:59 – Updated: 2026-09-17 12:30
    VLAI
    Title
    Hard-coded Encryption Key Vulnerability in Acer System Monitoring for NitroSense and PredatorSense Software
    Summary
    A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-17 12:26 UTC
    CWE
    • CWE-321 - Hardcoded AES-128-ECB Key
    References
    Impacted products
    Vendor Product Version
    Acer System Monitoring Affected: * , ≤ 1.0.19.2 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50606",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-17T12:26:30.763323Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-17T12:30:03.105Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "System Monitoring",
              "vendor": "Acer",
              "versions": [
                {
                  "lessThanOrEqual": "1.0.19.2",
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Tolga Cohce"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions."
                }
              ],
              "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Leveraging Hard-coded Credentials"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 1.2,
                "baseSeverity": "LOW",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:U",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "CWE-321 Hardcoded AES-128-ECB Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-17T08:01:19.643Z",
            "orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
            "shortName": "Acer"
          },
          "references": [
            {
              "url": "https://community.acer.com/en/kb/articles/19873"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "Update to one of the following versions or later:\n\n  *  NitroSense v5.2.84\n  *  PredatorSense v5.2.109"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Hard-coded Encryption Key Vulnerability in Acer System Monitoring for NitroSense and PredatorSense Software",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
        "assignerShortName": "Acer",
        "cveId": "CVE-2026-50606",
        "datePublished": "2026-09-17T07:59:52.258Z",
        "dateReserved": "2026-06-05T07:22:32.054Z",
        "dateUpdated": "2026-09-17T12:30:03.105Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50610 (GCVE-0-2026-50610)

    Vulnerability from cvelistv5 – Published: 2026-09-17 08:26 – Updated: 2026-09-17 12:18
    VLAI
    Title
    Improper Access control Vulnerability in NitroSense and PredatorSense Software
    Summary
    A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense due to insufficient access controls in a privileged service. An authenticated local user may be able to access the service and perform unauthorized registry modifications, potentially resulting in local privilege escalation.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-17 12:16 UTC
    CWE
    • CWE-284 - Improper Access Control
    References
    Impacted products
    Vendor Product Version
    Acer System Monitoring Affected: * , ≤ 1.0.19.2 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50610",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-17T12:16:15.601033Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-17T12:18:12.672Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "System Monitoring",
              "vendor": "Acer",
              "versions": [
                {
                  "lessThanOrEqual": "1.0.19.2",
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Cassius GARAT"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense due to insufficient access controls in a privileged service. An authenticated local user may be able to access the service and perform unauthorized registry modifications, potentially resulting in local privilege escalation."
                }
              ],
              "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense due to insufficient access controls in a privileged service. An authenticated local user may be able to access the service and perform unauthorized registry modifications, potentially resulting in local privilege escalation."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233: Privilege Escalation"
                }
              ]
            },
            {
              "capecId": "CAPEC-180",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-180: Exploiting Incorrectly Configured Access Control Security Levels"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-17T08:26:21.362Z",
            "orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
            "shortName": "Acer"
          },
          "references": [
            {
              "url": "https://community.acer.com/en/kb/articles/19877"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "Update to one of the following versions or later:\n\n  *  NitroSense v5.2.84\n  *  PredatorSense v5.2.109"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Improper Access control Vulnerability in NitroSense and PredatorSense Software",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
        "assignerShortName": "Acer",
        "cveId": "CVE-2026-50610",
        "datePublished": "2026-09-17T08:26:21.362Z",
        "dateReserved": "2026-06-05T07:22:32.054Z",
        "dateUpdated": "2026-09-17T12:18:12.672Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50609 (GCVE-0-2026-50609)

    Vulnerability from cvelistv5 – Published: 2026-09-17 08:21 – Updated: 2026-09-17 12:24
    VLAI
    Title
    Unauthorized Registry Modification Vulnerability in NitroSense and PredatorSense Software
    Summary
    A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-17 12:23 UTC
    CWE
    • CWE-284 - Improper Access Control
    References
    Impacted products
    Vendor Product Version
    Acer System Monitoring Affected: * , ≤ 1.0.19.2 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50609",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-17T12:23:07.250428Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-17T12:24:11.273Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "System Monitoring",
              "vendor": "Acer",
              "versions": [
                {
                  "lessThanOrEqual": "1.0.19.2",
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Cassius GARAT"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system."
                }
              ],
              "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-180",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels"
                }
              ]
            },
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-17T08:21:29.786Z",
            "orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
            "shortName": "Acer"
          },
          "references": [
            {
              "url": "https://community.acer.com/en/kb/articles/19876"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "Update to one of the following versions or later:\n\n  *  NitroSense v5.2.84\n  *  PredatorSense v5.2.109"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unauthorized Registry Modification Vulnerability in NitroSense and PredatorSense Software",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
        "assignerShortName": "Acer",
        "cveId": "CVE-2026-50609",
        "datePublished": "2026-09-17T08:21:29.786Z",
        "dateReserved": "2026-06-05T07:22:32.054Z",
        "dateUpdated": "2026-09-17T12:24:11.273Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50608 (GCVE-0-2026-50608)

    Vulnerability from cvelistv5 – Published: 2026-09-17 08:15 – Updated: 2026-09-17 12:25
    VLAI
    Title
    Authentication Vulnerability in NitroSense and PredatorSense Software
    Summary
    A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The WebSocket handshake process does not properly require authentication before allowing connections to the service. Under certain circumstances, unauthorized access to service functionality may be possible.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-17 12:25 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    References
    Impacted products
    Vendor Product Version
    Acer System Monitoring Affected: * , ≤ 1.0.19.2 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50608",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-17T12:25:32.773472Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-17T12:25:51.670Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "System Monitoring",
              "vendor": "Acer",
              "versions": [
                {
                  "lessThanOrEqual": "1.0.19.2",
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Ayush Choudhary"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The WebSocket handshake process does not properly require authentication before allowing connections to the service. Under certain circumstances, unauthorized access to service functionality may be possible."
                }
              ],
              "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The WebSocket handshake process does not properly require authentication before allowing connections to the service. Under certain circumstances, unauthorized access to service functionality may be possible."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 1.2,
                "baseSeverity": "LOW",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:U",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-17T08:15:17.327Z",
            "orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
            "shortName": "Acer"
          },
          "references": [
            {
              "url": "https://community.acer.com/en/kb/articles/19875"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "Update to one of the following versions or later:\n\n  *  NitroSense v5.2.84\n  *  PredatorSense v5.2.109"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Authentication Vulnerability in NitroSense and PredatorSense Software",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
        "assignerShortName": "Acer",
        "cveId": "CVE-2026-50608",
        "datePublished": "2026-09-17T08:15:17.327Z",
        "dateReserved": "2026-06-05T07:22:32.054Z",
        "dateUpdated": "2026-09-17T12:25:51.670Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50607 (GCVE-0-2026-50607)

    Vulnerability from cvelistv5 – Published: 2026-09-17 08:05 – Updated: 2026-09-17 12:26
    VLAI
    Title
    WebSocket Exposure Vulnerability in NitroSense and PredatorSense Software
    Summary
    A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. A WebSocket service was configured to listen on all network interfaces, which may expose the service to unintended network access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-17 12:26 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Acer System Monitoring Affected: * , ≤ 1.0.19.2 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50607",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-17T12:26:05.665465Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-17T12:26:18.604Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "System Monitoring",
              "vendor": "Acer",
              "versions": [
                {
                  "lessThanOrEqual": "1.0.19.2",
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Tolga Cohce"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. A WebSocket service was configured to listen on all network interfaces, which may expose the service to unintended network access."
                }
              ],
              "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. A WebSocket service was configured to listen on all network interfaces, which may expose the service to unintended network access."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-118",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-118: Collect and Analyze Information"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:U",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-668",
                  "description": "CWE-668 All-Interface Binding",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-17T08:22:19.514Z",
            "orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
            "shortName": "Acer"
          },
          "references": [
            {
              "url": "https://community.acer.com/en/kb/articles/19879"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "WebSocket Exposure Vulnerability in NitroSense and PredatorSense Software",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
        "assignerShortName": "Acer",
        "cveId": "CVE-2026-50607",
        "datePublished": "2026-09-17T08:05:44.472Z",
        "dateReserved": "2026-06-05T07:22:32.054Z",
        "dateUpdated": "2026-09-17T12:26:18.604Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50606 (GCVE-0-2026-50606)

    Vulnerability from cvelistv5 – Published: 2026-09-17 07:59 – Updated: 2026-09-17 12:30
    VLAI
    Title
    Hard-coded Encryption Key Vulnerability in Acer System Monitoring for NitroSense and PredatorSense Software
    Summary
    A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-17 12:26 UTC
    CWE
    • CWE-321 - Hardcoded AES-128-ECB Key
    References
    Impacted products
    Vendor Product Version
    Acer System Monitoring Affected: * , ≤ 1.0.19.2 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50606",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-17T12:26:30.763323Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-17T12:30:03.105Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "System Monitoring",
              "vendor": "Acer",
              "versions": [
                {
                  "lessThanOrEqual": "1.0.19.2",
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Tolga Cohce"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions."
                }
              ],
              "value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Leveraging Hard-coded Credentials"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 1.2,
                "baseSeverity": "LOW",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:U",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "CWE-321 Hardcoded AES-128-ECB Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-17T08:01:19.643Z",
            "orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
            "shortName": "Acer"
          },
          "references": [
            {
              "url": "https://community.acer.com/en/kb/articles/19873"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "Update to one of the following versions or later:\n\n  *  NitroSense v5.2.84\n  *  PredatorSense v5.2.109"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Hard-coded Encryption Key Vulnerability in Acer System Monitoring for NitroSense and PredatorSense Software",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
        "assignerShortName": "Acer",
        "cveId": "CVE-2026-50606",
        "datePublished": "2026-09-17T07:59:52.258Z",
        "dateReserved": "2026-06-05T07:22:32.054Z",
        "dateUpdated": "2026-09-17T12:30:03.105Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }