All the vulnerabilites related to Dell EMC - VNX Control Station in Dell EMC VNX2 OE for File
cve-2019-3704
Vulnerability from cvelistv5
Published
2019-02-07 19:00
Modified
2024-09-16 17:58
Summary
VNX Control Station in Dell EMC VNX2 OE for File versions prior to 8.1.9.236 contains OS command injection vulnerability. Due to inadequate restriction configured in sudores, a local authenticated malicious user could potentially execute arbitrary OS commands as root by exploiting this vulnerability.
References
http://www.securityfocus.com/bid/106954vdb-entry, x_refsource_BID
https://seclists.org/fulldisclosure/2019/Feb/8mailing-list, x_refsource_FULLDISC
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:19:18.184Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "106954",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/106954"
          },
          {
            "name": "20190204 DSA-2019-010: Dell EMC VNX2 Family OS Command Injection Vulnerability",
            "tags": [
              "mailing-list",
              "x_refsource_FULLDISC",
              "x_transferred"
            ],
            "url": "https://seclists.org/fulldisclosure/2019/Feb/8"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VNX Control Station in Dell EMC VNX2 OE for File",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThan": "8.1.9.236",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-02-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "VNX Control Station in Dell EMC VNX2 OE for File versions prior to 8.1.9.236 contains OS command injection vulnerability. Due to inadequate restriction configured in sudores, a local authenticated malicious user could potentially execute arbitrary OS commands as root by exploiting this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "OS Command Injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-02-11T10:57:01",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "name": "106954",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/106954"
        },
        {
          "name": "20190204 DSA-2019-010: Dell EMC VNX2 Family OS Command Injection Vulnerability",
          "tags": [
            "mailing-list",
            "x_refsource_FULLDISC"
          ],
          "url": "https://seclists.org/fulldisclosure/2019/Feb/8"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security_alert@emc.com",
          "DATE_PUBLIC": "2019-02-04T05:00:00.000Z",
          "ID": "CVE-2019-3704",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VNX Control Station in Dell EMC VNX2 OE for File",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_value": "8.1.9.236"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell EMC"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "VNX Control Station in Dell EMC VNX2 OE for File versions prior to 8.1.9.236 contains OS command injection vulnerability. Due to inadequate restriction configured in sudores, a local authenticated malicious user could potentially execute arbitrary OS commands as root by exploiting this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OS Command Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "106954",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/106954"
            },
            {
              "name": "20190204 DSA-2019-010: Dell EMC VNX2 Family OS Command Injection Vulnerability",
              "refsource": "FULLDISC",
              "url": "https://seclists.org/fulldisclosure/2019/Feb/8"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2019-3704",
    "datePublished": "2019-02-07T19:00:00Z",
    "dateReserved": "2019-01-03T00:00:00",
    "dateUpdated": "2024-09-16T17:58:08.973Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",