CVE-2019-3704 (GCVE-0-2019-3704)
Vulnerability from cvelistv5 – Published: 2019-02-07 19:00 – Updated: 2024-09-16 17:58
VLAI?
Summary
VNX Control Station in Dell EMC VNX2 OE for File versions prior to 8.1.9.236 contains OS command injection vulnerability. Due to inadequate restriction configured in sudores, a local authenticated malicious user could potentially execute arbitrary OS commands as root by exploiting this vulnerability.
Severity ?
7.8 (High)
CWE
- OS Command Injection
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell EMC | VNX Control Station in Dell EMC VNX2 OE for File |
Affected:
unspecified , < 8.1.9.236
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:19:18.184Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "106954",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/106954"
},
{
"name": "20190204 DSA-2019-010: Dell EMC VNX2 Family OS Command Injection Vulnerability",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "https://seclists.org/fulldisclosure/2019/Feb/8"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "VNX Control Station in Dell EMC VNX2 OE for File",
"vendor": "Dell EMC",
"versions": [
{
"lessThan": "8.1.9.236",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-02-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "VNX Control Station in Dell EMC VNX2 OE for File versions prior to 8.1.9.236 contains OS command injection vulnerability. Due to inadequate restriction configured in sudores, a local authenticated malicious user could potentially execute arbitrary OS commands as root by exploiting this vulnerability."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "OS Command Injection",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-02-11T10:57:01",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"name": "106954",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/106954"
},
{
"name": "20190204 DSA-2019-010: Dell EMC VNX2 Family OS Command Injection Vulnerability",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "https://seclists.org/fulldisclosure/2019/Feb/8"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security_alert@emc.com",
"DATE_PUBLIC": "2019-02-04T05:00:00.000Z",
"ID": "CVE-2019-3704",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "VNX Control Station in Dell EMC VNX2 OE for File",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_value": "8.1.9.236"
}
]
}
}
]
},
"vendor_name": "Dell EMC"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "VNX Control Station in Dell EMC VNX2 OE for File versions prior to 8.1.9.236 contains OS command injection vulnerability. Due to inadequate restriction configured in sudores, a local authenticated malicious user could potentially execute arbitrary OS commands as root by exploiting this vulnerability."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "OS Command Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "106954",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/106954"
},
{
"name": "20190204 DSA-2019-010: Dell EMC VNX2 Family OS Command Injection Vulnerability",
"refsource": "FULLDISC",
"url": "https://seclists.org/fulldisclosure/2019/Feb/8"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2019-3704",
"datePublished": "2019-02-07T19:00:00Z",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-09-16T17:58:08.973Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:emc_vnx2_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"8.1.9.217\", \"matchCriteriaId\": \"2818A98E-B31B-4243-B85E-DD236199E4F6\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:emc_vnx2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CF905D70-D7F1-460E-ADB4-5CBC545F0852\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"VNX Control Station in Dell EMC VNX2 OE for File versions prior to 8.1.9.236 contains OS command injection vulnerability. Due to inadequate restriction configured in sudores, a local authenticated malicious user could potentially execute arbitrary OS commands as root by exploiting this vulnerability.\"}, {\"lang\": \"es\", \"value\": \"VNX Control Station en Dell EMC VNX2 OE for File, en versiones anteriores a la 8.1.9.236, contiene una vulnerabilidad de inyecci\\u00f3n de comandos del sistema operativo. Debido a las restricciones inadecuadas configuradas en sudores, un usuario local autenticado malicioso podr\\u00eda ejecutar comandos arbitrarios del sistema operativo como root explotando esta vulnerabilidad.\"}]",
"id": "CVE-2019-3704",
"lastModified": "2024-11-21T04:42:22.113",
"metrics": "{\"cvssMetricV30\": [{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 7.2, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 3.9, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2019-02-07T19:29:00.270",
"references": "[{\"url\": \"http://www.securityfocus.com/bid/106954\", \"source\": \"security_alert@emc.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://seclists.org/fulldisclosure/2019/Feb/8\", \"source\": \"security_alert@emc.com\", \"tags\": [\"Mailing List\", \"Third Party Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/106954\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://seclists.org/fulldisclosure/2019/Feb/8\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mailing List\", \"Third Party Advisory\"]}]",
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-78\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-3704\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2019-02-07T19:29:00.270\",\"lastModified\":\"2024-11-21T04:42:22.113\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"VNX Control Station in Dell EMC VNX2 OE for File versions prior to 8.1.9.236 contains OS command injection vulnerability. Due to inadequate restriction configured in sudores, a local authenticated malicious user could potentially execute arbitrary OS commands as root by exploiting this vulnerability.\"},{\"lang\":\"es\",\"value\":\"VNX Control Station en Dell EMC VNX2 OE for File, en versiones anteriores a la 8.1.9.236, contiene una vulnerabilidad de inyecci\u00f3n de comandos del sistema operativo. Debido a las restricciones inadecuadas configuradas en sudores, un usuario local autenticado malicioso podr\u00eda ejecutar comandos arbitrarios del sistema operativo como root explotando esta vulnerabilidad.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_vnx2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.1.9.217\",\"matchCriteriaId\":\"2818A98E-B31B-4243-B85E-DD236199E4F6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:emc_vnx2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CF905D70-D7F1-460E-ADB4-5CBC545F0852\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/106954\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://seclists.org/fulldisclosure/2019/Feb/8\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/106954\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://seclists.org/fulldisclosure/2019/Feb/8\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…