CVE-2019-3704
Vulnerability from cvelistv5
Published
2019-02-07 19:00
Modified
2024-09-16 17:58
Severity ?
EPSS score ?
Summary
VNX Control Station in Dell EMC VNX2 OE for File versions prior to 8.1.9.236 contains OS command injection vulnerability. Due to inadequate restriction configured in sudores, a local authenticated malicious user could potentially execute arbitrary OS commands as root by exploiting this vulnerability.
References
▼ | URL | Tags | |
---|---|---|---|
security_alert@emc.com | http://www.securityfocus.com/bid/106954 | Third Party Advisory | |
security_alert@emc.com | https://seclists.org/fulldisclosure/2019/Feb/8 | Mailing List, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/106954 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://seclists.org/fulldisclosure/2019/Feb/8 | Mailing List, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Dell EMC | VNX Control Station in Dell EMC VNX2 OE for File |
Version: unspecified < 8.1.9.236 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T19:19:18.184Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "106954", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/106954" }, { "name": "20190204 DSA-2019-010: Dell EMC VNX2 Family OS Command Injection Vulnerability", "tags": [ "mailing-list", "x_refsource_FULLDISC", "x_transferred" ], "url": "https://seclists.org/fulldisclosure/2019/Feb/8" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "VNX Control Station in Dell EMC VNX2 OE for File", "vendor": "Dell EMC", "versions": [ { "lessThan": "8.1.9.236", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2019-02-04T00:00:00", "descriptions": [ { "lang": "en", "value": "VNX Control Station in Dell EMC VNX2 OE for File versions prior to 8.1.9.236 contains OS command injection vulnerability. Due to inadequate restriction configured in sudores, a local authenticated malicious user could potentially execute arbitrary OS commands as root by exploiting this vulnerability." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "OS Command Injection", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-02-11T10:57:01", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "name": "106954", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/106954" }, { "name": "20190204 DSA-2019-010: Dell EMC VNX2 Family OS Command Injection Vulnerability", "tags": [ "mailing-list", "x_refsource_FULLDISC" ], "url": "https://seclists.org/fulldisclosure/2019/Feb/8" } ], "source": { "discovery": "UNKNOWN" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "security_alert@emc.com", "DATE_PUBLIC": "2019-02-04T05:00:00.000Z", "ID": "CVE-2019-3704", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "VNX Control Station in Dell EMC VNX2 OE for File", "version": { "version_data": [ { "affected": "\u003c", "version_affected": "\u003c", "version_value": "8.1.9.236" } ] } } ] }, "vendor_name": "Dell EMC" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "VNX Control Station in Dell EMC VNX2 OE for File versions prior to 8.1.9.236 contains OS command injection vulnerability. Due to inadequate restriction configured in sudores, a local authenticated malicious user could potentially execute arbitrary OS commands as root by exploiting this vulnerability." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "OS Command Injection" } ] } ] }, "references": { "reference_data": [ { "name": "106954", "refsource": "BID", "url": "http://www.securityfocus.com/bid/106954" }, { "name": "20190204 DSA-2019-010: Dell EMC VNX2 Family OS Command Injection Vulnerability", "refsource": "FULLDISC", "url": "https://seclists.org/fulldisclosure/2019/Feb/8" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2019-3704", "datePublished": "2019-02-07T19:00:00Z", "dateReserved": "2019-01-03T00:00:00", "dateUpdated": "2024-09-16T17:58:08.973Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-3704\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2019-02-07T19:29:00.270\",\"lastModified\":\"2024-11-21T04:42:22.113\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"VNX Control Station in Dell EMC VNX2 OE for File versions prior to 8.1.9.236 contains OS command injection vulnerability. Due to inadequate restriction configured in sudores, a local authenticated malicious user could potentially execute arbitrary OS commands as root by exploiting this vulnerability.\"},{\"lang\":\"es\",\"value\":\"VNX Control Station en Dell EMC VNX2 OE for File, en versiones anteriores a la 8.1.9.236, contiene una vulnerabilidad de inyecci\u00f3n de comandos del sistema operativo. Debido a las restricciones inadecuadas configuradas en sudores, un usuario local autenticado malicioso podr\u00eda ejecutar comandos arbitrarios del sistema operativo como root explotando esta vulnerabilidad.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_vnx2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.1.9.217\",\"matchCriteriaId\":\"2818A98E-B31B-4243-B85E-DD236199E4F6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:emc_vnx2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CF905D70-D7F1-460E-ADB4-5CBC545F0852\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/106954\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://seclists.org/fulldisclosure/2019/Feb/8\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/106954\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://seclists.org/fulldisclosure/2019/Feb/8\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.