Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    10 vulnerabilities found for WinBox by MikroTik

    VAR-202002-1046

    Vulnerability from variot - Updated: 2023-12-18 14:04

    MikroTik WinBox before 3.21 is vulnerable to a path traversal vulnerability that allows creation of arbitrary files wherevere WinBox has write permissions. WinBox is vulnerable to this attack if it connects to a malicious endpoint or if an attacker mounts a man in the middle attack. MikroTik WinBox Exists in a past traversal vulnerability.Information may be tampered with

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202002-1046",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "winbox",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "mikrotik",
            "version": "3.21"
          },
          {
            "model": "winbox",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "mikrotik",
            "version": "3.21"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-001747"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5720"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mikrotik:winbox:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.21",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-5720"
          }
        ]
      },
      "cve": "CVE-2020-5720",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 8.6,
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Medium",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 4.3,
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-001747",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.2,
                "impactScore": 3.6,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "High",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 5.9,
                "baseSeverity": "Medium",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-001747",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2020-5720",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "JVNDB-2020-001747",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202002-172",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-001747"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5720"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202002-172"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "MikroTik WinBox before 3.21 is vulnerable to a path traversal vulnerability that allows creation of arbitrary files wherevere WinBox has write permissions. WinBox is vulnerable to this attack if it connects to a malicious endpoint or if an attacker mounts a man in the middle attack. MikroTik WinBox Exists in a past traversal vulnerability.Information may be tampered with",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-5720"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-001747"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "TENABLE",
            "id": "TRA-2020-07",
            "trust": 2.4
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5720",
            "trust": 2.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-001747",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202002-172",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-001747"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5720"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202002-172"
          }
        ]
      },
      "id": "VAR-202002-1046",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.3125
      },
      "last_update_date": "2023-12-18T14:04:50.870000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://mikrotik.com/"
          },
          {
            "title": "MikroTik WinBox Repair measures for path traversal vulnerabilities",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=109373"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-001747"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202002-172"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-22",
            "trust": 1.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-001747"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5720"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://www.tenable.com/security/research/tra-2020-07"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-5720"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5720"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-001747"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5720"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202002-172"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-001747"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5720"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202002-172"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-02-25T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-001747"
          },
          {
            "date": "2020-02-06T17:15:14.020000",
            "db": "NVD",
            "id": "CVE-2020-5720"
          },
          {
            "date": "2020-02-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202002-172"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-02-25T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-001747"
          },
          {
            "date": "2020-02-10T14:31:17.920000",
            "db": "NVD",
            "id": "CVE-2020-5720"
          },
          {
            "date": "2023-05-19T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202002-172"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202002-172"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "MikroTik WinBox Past Traversal Vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-001747"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "path traversal",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202002-172"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202001-0420

    Vulnerability from variot - Updated: 2023-12-18 13:37

    MikroTik Winbox 3.20 and below is vulnerable to man in the middle attacks. A man in the middle can downgrade the client's authentication protocol and recover the user's username and MD5 hashed password. MikroTik Winbox Contains an input validation vulnerability.Information may be obtained. A security vulnerability exists in MikroTik Winbox 3.20 and earlier versions

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202001-0420",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "winbox",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "mikrotik",
            "version": "3.20"
          },
          {
            "model": "routeros",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "mikrotik",
            "version": "6.43"
          },
          {
            "model": "routeros",
            "scope": null,
            "trust": 0.8,
            "vendor": "mikrotik",
            "version": null
          },
          {
            "model": "winbox",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "mikrotik",
            "version": "3.20"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-014160"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3981"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mikrotik:routeros:*:*:*:*:-:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.43",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:mikrotik:winbox:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.20",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-3981"
          }
        ]
      },
      "cve": "CVE-2019-3981",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Medium",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 4.3,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2019-3981",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "VHN-155416",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:M/AU:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 3.7,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.2,
                "impactScore": 1.4,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "High",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 3.7,
                "baseSeverity": "Low",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "CVE-2019-3981",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-3981",
                "trust": 1.8,
                "value": "LOW"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202001-455",
                "trust": 0.6,
                "value": "LOW"
              },
              {
                "author": "VULHUB",
                "id": "VHN-155416",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-155416"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-014160"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3981"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202001-455"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "MikroTik Winbox 3.20 and below is vulnerable to man in the middle attacks. A man in the middle can downgrade the client\u0027s authentication protocol and recover the user\u0027s username and MD5 hashed password. MikroTik Winbox Contains an input validation vulnerability.Information may be obtained. A security vulnerability exists in MikroTik Winbox 3.20 and earlier versions",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-3981"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-014160"
          },
          {
            "db": "VULHUB",
            "id": "VHN-155416"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "TENABLE",
            "id": "TRA-2020-01",
            "trust": 2.5
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3981",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-014160",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202001-455",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-07244",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-155416",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-155416"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-014160"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3981"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202001-455"
          }
        ]
      },
      "id": "VAR-202001-0420",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-155416"
          }
        ],
        "trust": 0.4125
      },
      "last_update_date": "2023-12-18T13:37:59.158000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://mikrotik.com/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-014160"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-Other",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-20",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-155416"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-014160"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3981"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "https://www.tenable.com/security/research/tra-2020-01"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-3981"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-3981"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-155416"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-014160"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3981"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202001-455"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-155416"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-014160"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3981"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202001-455"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-01-14T00:00:00",
            "db": "VULHUB",
            "id": "VHN-155416"
          },
          {
            "date": "2020-02-05T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-014160"
          },
          {
            "date": "2020-01-14T19:15:13.187000",
            "db": "NVD",
            "id": "CVE-2019-3981"
          },
          {
            "date": "2020-01-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202001-455"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-10-22T00:00:00",
            "db": "VULHUB",
            "id": "VHN-155416"
          },
          {
            "date": "2020-02-05T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-014160"
          },
          {
            "date": "2020-10-22T17:38:23.373000",
            "db": "NVD",
            "id": "CVE-2019-3981"
          },
          {
            "date": "2021-01-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202001-455"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202001-455"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "MikroTik Winbox Input validation vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-014160"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202001-455"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202004-1843

    Vulnerability from variot - Updated: 2023-12-18 13:12

    MikroTik WinBox 3.22 and below stores the user's cleartext password in the settings.cfg.viw configuration file when the Keep Password field is set and no Master Password is set. Keep Password is set by default and, by default Master Password is not set. An attacker with access to the configuration file can extract a username and password to gain access to the router. MikroTik WinBox Exists in an inadequate protection of credentials.Information may be obtained. MikroTik WinBox could allow a local malicious user to obtain sensitive information, caused by the storage of user credentials in plain-text in the settings.cfg.viw configuration file

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202004-1843",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "winbox",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "mikrotik",
            "version": "3.22"
          },
          {
            "model": "winbox",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "mikrotik",
            "version": "3.22"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004802"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5721"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mikrotik:winbox:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "3.22",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-5721"
          }
        ]
      },
      "cve": "CVE-2020-5721",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 2.1,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.9,
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "LOW",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Local",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 2.1,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-004802",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Low",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "VULMON",
                "availabilityImpact": "NONE",
                "baseScore": 2.1,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.9,
                "id": "CVE-2020-5721",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "LOW",
                "trust": 0.1,
                "userInteractionRequired": null,
                "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 5.5,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-004802",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2020-5721",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "JVNDB-2020-004802",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202004-1149",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2020-5721",
                "trust": 0.1,
                "value": "LOW"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2020-5721"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004802"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5721"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1149"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "MikroTik WinBox 3.22 and below stores the user\u0027s cleartext password in the settings.cfg.viw configuration file when the Keep Password field is set and no Master Password is set. Keep Password is set by default and, by default Master Password is not set. An attacker with access to the configuration file can extract a username and password to gain access to the router. MikroTik WinBox Exists in an inadequate protection of credentials.Information may be obtained. MikroTik WinBox could allow a local malicious user to obtain sensitive information, caused by the storage of user credentials in plain-text in the settings.cfg.viw configuration file",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-5721"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004802"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-5721"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "TENABLE",
            "id": "TRA-2020-23",
            "trust": 2.5
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5721",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004802",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1149",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-5721",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2020-5721"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004802"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5721"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1149"
          }
        ]
      },
      "id": "VAR-202004-1843",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.3125
      },
      "last_update_date": "2023-12-18T13:12:59.394000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://mikrotik.com/\\"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004802"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-522",
            "trust": 1.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004802"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5721"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "https://www.tenable.com/security/research/tra-2020-23"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-5721"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5721"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/522.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          },
          {
            "trust": 0.1,
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/180007"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2020-5721"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004802"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5721"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1149"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2020-5721"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004802"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5721"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1149"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-04-15T00:00:00",
            "db": "VULMON",
            "id": "CVE-2020-5721"
          },
          {
            "date": "2020-05-28T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-004802"
          },
          {
            "date": "2020-04-15T21:15:36.607000",
            "db": "NVD",
            "id": "CVE-2020-5721"
          },
          {
            "date": "2020-04-15T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202004-1149"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-04-28T00:00:00",
            "db": "VULMON",
            "id": "CVE-2020-5721"
          },
          {
            "date": "2020-05-28T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-004802"
          },
          {
            "date": "2020-04-28T15:44:00.507000",
            "db": "NVD",
            "id": "CVE-2020-5721"
          },
          {
            "date": "2020-04-29T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202004-1149"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1149"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "MikroTik WinBox Vulnerability regarding inadequate protection of credentials in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-004802"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202004-1149"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201807-2272

    Vulnerability from variot - Updated: 2022-05-04 09:39

    MikroTikRouterOS is a routing operating system based on Linux kernel development, compatible with x86PC routing software, which can be used to turn a standard PC into a professional router. Winbox is a software for remotely managing RouterOS based on Windows, providing an intuitive and convenient graphical interface. There are arbitrary file access vulnerabilities in MikrotikWinbox. An attacker can download arbitrary files, including the user database file of RouterOS, through a carefully constructed request package.

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201807-2272",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "winbox",
            "scope": "gte",
            "trust": 0.6,
            "vendor": "mikrotik",
            "version": "6.29,\u003c=6.42"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-12706"
          }
        ]
      },
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2018-12706",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [],
            "severity": [
              {
                "author": "CNVD",
                "id": "CNVD-2018-12706",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-12706"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "MikroTikRouterOS is a routing operating system based on Linux kernel development, compatible with x86PC routing software, which can be used to turn a standard PC into a professional router. Winbox is a software for remotely managing RouterOS based on Windows, providing an intuitive and convenient graphical interface. There are arbitrary file access vulnerabilities in MikrotikWinbox. An attacker can download arbitrary files, including the user database file of RouterOS, through a carefully constructed request package.",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-12706"
          }
        ],
        "trust": 0.6
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-12706",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-12706"
          }
        ]
      },
      "id": "VAR-201807-2272",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-12706"
          }
        ],
        "trust": 0.9125
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-12706"
          }
        ]
      },
      "last_update_date": "2022-05-04T09:39:04.468000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "MikrotikWinbox patch for arbitrary file access vulnerabilities",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/133823"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-12706"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 0.6,
            "url": "https://github.com/basucert/winboxpoc"
          },
          {
            "trust": 0.6,
            "url": "https://n0p.me/winbox-bug-dissection/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-12706"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-12706"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-07-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2018-12706"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-07-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2018-12706"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Mikrotik Winbox Arbitrary File Access Vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-12706"
          }
        ],
        "trust": 0.6
      }
    }

    CVE-2020-5721 (GCVE-0-2020-5721)

    Vulnerability from cvelistv5 – Published: 2020-04-15 20:50 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    MikroTik WinBox 3.22 and below stores the user's cleartext password in the settings.cfg.viw configuration file when the Keep Password field is set and no Master Password is set. Keep Password is set by default and, by default Master Password is not set. An attacker with access to the configuration file can extract a username and password to gain access to the router.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a MikroTik WinBox Affected: 3.22 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.683Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-23"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MikroTik WinBox",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.22 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "MikroTik WinBox 3.22 and below stores the user\u0027s cleartext password in the settings.cfg.viw configuration file when the Keep Password field is set and no Master Password is set. Keep Password is set by default and, by default Master Password is not set. An attacker with access to the configuration file can extract a username and password to gain access to the router."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-260",
                  "description": "CWE-260",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-15T20:50:45.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-23"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5721",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MikroTik WinBox",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "3.22 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "MikroTik WinBox 3.22 and below stores the user\u0027s cleartext password in the settings.cfg.viw configuration file when the Keep Password field is set and no Master Password is set. Keep Password is set by default and, by default Master Password is not set. An attacker with access to the configuration file can extract a username and password to gain access to the router."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-260"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-23",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-23"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5721",
        "datePublished": "2020-04-15T20:50:45.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.683Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5720 (GCVE-0-2020-5720)

    Vulnerability from cvelistv5 – Published: 2020-02-06 16:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    MikroTik WinBox before 3.21 is vulnerable to a path traversal vulnerability that allows creation of arbitrary files wherevere WinBox has write permissions. WinBox is vulnerable to this attack if it connects to a malicious endpoint or if an attacker mounts a man in the middle attack.
    Severity
    No CVSS data available.
    CWE
    • CWE-22 - Path Traversal File Writing (CWE-22)
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a MikroTik WinBox Affected: All versions prior to version 3.21
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.501Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-07"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MikroTik WinBox",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 3.21"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "MikroTik WinBox before 3.21 is vulnerable to a path traversal vulnerability that allows creation of arbitrary files wherevere WinBox has write permissions. WinBox is vulnerable to this attack if it connects to a malicious endpoint or if an attacker mounts a man in the middle attack."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "Path Traversal File Writing (CWE-22)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-02-06T16:51:16.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-07"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5720",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MikroTik WinBox",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions prior to version 3.21"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "MikroTik WinBox before 3.21 is vulnerable to a path traversal vulnerability that allows creation of arbitrary files wherevere WinBox has write permissions. WinBox is vulnerable to this attack if it connects to a malicious endpoint or if an attacker mounts a man in the middle attack."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Path Traversal File Writing (CWE-22)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-07",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-07"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5720",
        "datePublished": "2020-02-06T16:51:16.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.501Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-3981 (GCVE-0-2019-3981)

    Vulnerability from cvelistv5 – Published: 2020-01-14 18:13 – Updated: 2024-08-04 19:26
    VLAI
    Summary
    MikroTik Winbox 3.20 and below is vulnerable to man in the middle attacks. A man in the middle can downgrade the client's authentication protocol and recover the user's username and MD5 hashed password.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    MikroTik WinBox Affected: Winbox 3.20 and below.
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T19:26:27.758Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "WinBox",
              "vendor": "MikroTik",
              "versions": [
                {
                  "status": "affected",
                  "version": "Winbox 3.20 and below."
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "MikroTik Winbox 3.20 and below is vulnerable to man in the middle attacks. A man in the middle can downgrade the client\u0027s authentication protocol and recover the user\u0027s username and MD5 hashed password."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-300",
                  "description": "CWE-300",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-14T18:13:57.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2019-3981",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "WinBox",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Winbox 3.20 and below."
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "MikroTik"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "MikroTik Winbox 3.20 and below is vulnerable to man in the middle attacks. A man in the middle can downgrade the client\u0027s authentication protocol and recover the user\u0027s username and MD5 hashed password."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-300"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-01",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2019-3981",
        "datePublished": "2020-01-14T18:13:57.000Z",
        "dateReserved": "2019-01-03T00:00:00.000Z",
        "dateUpdated": "2024-08-04T19:26:27.758Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5721 (GCVE-0-2020-5721)

    Vulnerability from nvd – Published: 2020-04-15 20:50 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    MikroTik WinBox 3.22 and below stores the user's cleartext password in the settings.cfg.viw configuration file when the Keep Password field is set and no Master Password is set. Keep Password is set by default and, by default Master Password is not set. An attacker with access to the configuration file can extract a username and password to gain access to the router.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a MikroTik WinBox Affected: 3.22 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.683Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-23"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MikroTik WinBox",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.22 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "MikroTik WinBox 3.22 and below stores the user\u0027s cleartext password in the settings.cfg.viw configuration file when the Keep Password field is set and no Master Password is set. Keep Password is set by default and, by default Master Password is not set. An attacker with access to the configuration file can extract a username and password to gain access to the router."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-260",
                  "description": "CWE-260",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-15T20:50:45.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-23"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5721",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MikroTik WinBox",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "3.22 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "MikroTik WinBox 3.22 and below stores the user\u0027s cleartext password in the settings.cfg.viw configuration file when the Keep Password field is set and no Master Password is set. Keep Password is set by default and, by default Master Password is not set. An attacker with access to the configuration file can extract a username and password to gain access to the router."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-260"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-23",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-23"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5721",
        "datePublished": "2020-04-15T20:50:45.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.683Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5720 (GCVE-0-2020-5720)

    Vulnerability from nvd – Published: 2020-02-06 16:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    MikroTik WinBox before 3.21 is vulnerable to a path traversal vulnerability that allows creation of arbitrary files wherevere WinBox has write permissions. WinBox is vulnerable to this attack if it connects to a malicious endpoint or if an attacker mounts a man in the middle attack.
    Severity
    No CVSS data available.
    CWE
    • CWE-22 - Path Traversal File Writing (CWE-22)
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a MikroTik WinBox Affected: All versions prior to version 3.21
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.501Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-07"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MikroTik WinBox",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 3.21"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "MikroTik WinBox before 3.21 is vulnerable to a path traversal vulnerability that allows creation of arbitrary files wherevere WinBox has write permissions. WinBox is vulnerable to this attack if it connects to a malicious endpoint or if an attacker mounts a man in the middle attack."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "Path Traversal File Writing (CWE-22)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-02-06T16:51:16.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-07"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5720",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MikroTik WinBox",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions prior to version 3.21"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "MikroTik WinBox before 3.21 is vulnerable to a path traversal vulnerability that allows creation of arbitrary files wherevere WinBox has write permissions. WinBox is vulnerable to this attack if it connects to a malicious endpoint or if an attacker mounts a man in the middle attack."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Path Traversal File Writing (CWE-22)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-07",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-07"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5720",
        "datePublished": "2020-02-06T16:51:16.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.501Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-3981 (GCVE-0-2019-3981)

    Vulnerability from nvd – Published: 2020-01-14 18:13 – Updated: 2024-08-04 19:26
    VLAI
    Summary
    MikroTik Winbox 3.20 and below is vulnerable to man in the middle attacks. A man in the middle can downgrade the client's authentication protocol and recover the user's username and MD5 hashed password.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    MikroTik WinBox Affected: Winbox 3.20 and below.
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T19:26:27.758Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "WinBox",
              "vendor": "MikroTik",
              "versions": [
                {
                  "status": "affected",
                  "version": "Winbox 3.20 and below."
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "MikroTik Winbox 3.20 and below is vulnerable to man in the middle attacks. A man in the middle can downgrade the client\u0027s authentication protocol and recover the user\u0027s username and MD5 hashed password."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-300",
                  "description": "CWE-300",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-14T18:13:57.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2019-3981",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "WinBox",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Winbox 3.20 and below."
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "MikroTik"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "MikroTik Winbox 3.20 and below is vulnerable to man in the middle attacks. A man in the middle can downgrade the client\u0027s authentication protocol and recover the user\u0027s username and MD5 hashed password."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-300"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-01",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2019-3981",
        "datePublished": "2020-01-14T18:13:57.000Z",
        "dateReserved": "2019-01-03T00:00:00.000Z",
        "dateUpdated": "2024-08-04T19:26:27.758Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",