Search criteria

16 vulnerabilities found for advabuild by abb

FKIE_CVE-2020-11640

Vulnerability from fkie_nvd - Published: 2024-07-23 18:15 - Updated: 2025-12-19 15:57
Summary
AdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the command queue can use it to launch an attack by running any executable on the AdvaBuild node. The executables that can be run are not limited to AdvaBuild specific executables.  Improper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.
Impacted products
Vendor Product Version
abb advabuild *
abb advabuild 3.7
abb advabuild 3.7
abb advabuild 3.7

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:abb:advabuild:*:*:*:*:*:advant_mod_300:*:*",
              "matchCriteriaId": "2B2DD8A5-17FB-4CCF-ABC0-2388B43D07F2",
              "versionEndExcluding": "3.7",
              "versionStartIncluding": "3.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:abb:advabuild:3.7:-:*:*:*:advant_mod_300:*:*",
              "matchCriteriaId": "88348546-89FF-4F82-8246-F9E08B585C78",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:abb:advabuild:3.7:sp1:*:*:*:advant_mod_300:*:*",
              "matchCriteriaId": "4E2D62C1-9F2D-42D5-997B-0880469C82E0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:abb:advabuild:3.7:sp2:*:*:*:advant_mod_300:*:*",
              "matchCriteriaId": "9D462F34-AD38-4EA0-97CE-9FE7A558920F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "AdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the\ncommand queue can use it to launch an attack by running any executable on the AdvaBuild node. The\nexecutables that can be run are not limited to AdvaBuild specific executables.\u00a0\n\nImproper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2."
    },
    {
      "lang": "es",
      "value": "AdvaBuild utiliza una cola de comandos para iniciar determinadas operaciones. Un atacante que obtenga acceso a la cola de comandos puede usarla para lanzar un ataque ejecutando cualquier ejecutable en el nodo AdvaBuild. Los ejecutables que se pueden ejecutar no se limitan a ejecutables espec\u00edficos de AdvaBuild. Vulnerabilidad de gesti\u00f3n de privilegios inadecuada en ABB Advant MOD 300 AdvaBuild. Este problema afecta a Advant MOD 300 AdvaBuild: desde 3.0 hasta 3.7 SP2."
    }
  ],
  "id": "CVE-2020-11640",
  "lastModified": "2025-12-19T15:57:45.533",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "cybersecurity@ch.abb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-07-23T18:15:05.083",
  "references": [
    {
      "source": "cybersecurity@ch.abb.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
    }
  ],
  "sourceIdentifier": "cybersecurity@ch.abb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-269"
        }
      ],
      "source": "cybersecurity@ch.abb.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2020-11639

Vulnerability from fkie_nvd - Published: 2024-07-23 18:15 - Updated: 2025-12-19 15:58
Summary
An attacker could exploit the vulnerability by injecting garbage data or specially crafted data. Depending on the data injected each process might be affected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing the product to store wrong information or act on wrong data or display wrong information. This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2. For an attack to be successful, the attacker must have local access to a node in the system and be able to start a specially crafted application that disrupts the communication. An attacker who successfully exploited the vulnerability would be able to manipulate the data in such way as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300 and AdvaBuild to crash.
Impacted products
Vendor Product Version
abb advabuild *
abb advabuild 3.7
abb advabuild 3.7
abb advabuild 3.7

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:abb:advabuild:*:*:*:*:*:advant_mod_300:*:*",
              "matchCriteriaId": "2B2DD8A5-17FB-4CCF-ABC0-2388B43D07F2",
              "versionEndExcluding": "3.7",
              "versionStartIncluding": "3.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:abb:advabuild:3.7:-:*:*:*:advant_mod_300:*:*",
              "matchCriteriaId": "88348546-89FF-4F82-8246-F9E08B585C78",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:abb:advabuild:3.7:sp1:*:*:*:advant_mod_300:*:*",
              "matchCriteriaId": "4E2D62C1-9F2D-42D5-997B-0880469C82E0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:abb:advabuild:3.7:sp2:*:*:*:advant_mod_300:*:*",
              "matchCriteriaId": "9D462F34-AD38-4EA0-97CE-9FE7A558920F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An attacker could exploit the vulnerability by\ninjecting garbage data or specially crafted data. Depending on the data injected each process might be\naffected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing\nthe product to store wrong information or act on wrong data or display wrong information.\n\n\nThis issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.\n\n\n\n\nFor an attack to be successful, the attacker must have local access to a node in the system and be able to\nstart a specially crafted application that disrupts the communication.\nAn attacker who successfully exploited the vulnerability would be able to manipulate the data in such\nway as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300\nand AdvaBuild to crash."
    },
    {
      "lang": "es",
      "value": "Un atacante podr\u00eda aprovechar la vulnerabilidad inyectando datos basura o datos especialmente manipulados. Dependiendo de los datos inyectados, cada proceso puede verse afectado de manera diferente. El proceso podr\u00eda fallar o causar problemas de comunicaci\u00f3n en el nodo afectado, provocando efectivamente un ataque de denegaci\u00f3n de servicio. El atacante podr\u00eda alterar los datos transmitidos, provocando que el producto almacene informaci\u00f3n incorrecta o act\u00fae sobre datos incorrectos o muestre informaci\u00f3n incorrecta. Este problema afecta a Advant MOD 300 AdvaBuild: desde 3.0 hasta 3.7 SP2. Para que un ataque tenga \u00e9xito, el atacante debe tener acceso local a un nodo del sistema y poder iniciar una aplicaci\u00f3n especialmente dise\u00f1ada que interrumpa la comunicaci\u00f3n. Un atacante que explotara con \u00e9xito la vulnerabilidad podr\u00eda manipular los datos de tal manera que permitiera lecturas y escrituras en los controladores o provocar que los procesos de Windows en 800xA para MOD 300 y AdvaBuild fallaran."
    }
  ],
  "id": "CVE-2020-11639",
  "lastModified": "2025-12-19T15:58:15.363",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "cybersecurity@ch.abb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-07-23T18:15:04.820",
  "references": [
    {
      "source": "cybersecurity@ch.abb.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
    }
  ],
  "sourceIdentifier": "cybersecurity@ch.abb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-924"
        }
      ],
      "source": "cybersecurity@ch.abb.com",
      "type": "Secondary"
    }
  ]
}

CVE-2020-11640 (GCVE-0-2020-11640)

Vulnerability from nvd – Published: 2024-07-23 17:36 – Updated: 2024-08-04 11:35
VLAI?
Title
Elevation of Privilege
Summary
AdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the command queue can use it to launch an attack by running any executable on the AdvaBuild node. The executables that can be run are not limited to AdvaBuild specific executables.  Improper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
ABB
Impacted products
Vendor Product Version
ABB Advant MOD 300 AdvaBuild Affected: 3.0 , ≤ 3.7 SP2 (update)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:abb:advabuild:*:*:*:*:*:*:mod_300:*"
            ],
            "defaultStatus": "unknown",
            "product": "advabuild",
            "vendor": "abb",
            "versions": [
              {
                "lessThanOrEqual": "3.7sp2",
                "status": "affected",
                "version": "3.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-11640",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-23T18:09:49.474898Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-24T19:00:53.120Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:35:13.681Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Advant MOD 300 AdvaBuild",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.7 SP2",
              "status": "affected",
              "version": "3.0",
              "versionType": "update"
            }
          ]
        }
      ],
      "datePublic": "2024-07-22T17:33:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nAdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the\ncommand queue can use it to launch an attack by running any executable on the AdvaBuild node. The\nexecutables that can be run are not limited to AdvaBuild specific executables.\u0026nbsp;\u003cbr\u003e\u003cbr\u003eImproper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.\u003cp\u003eThis issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.\u003c/p\u003e"
            }
          ],
          "value": "AdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the\ncommand queue can use it to launch an attack by running any executable on the AdvaBuild node. The\nexecutables that can be run are not limited to AdvaBuild specific executables.\u00a0\n\nImproper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-23T17:36:51.458Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nABB recommends changing any user account passwords which are suspected to be known by an unauthorized person. Interactive logon (both local and remote) is recommended to be disabled for service\naccounts.\n\n\u003cbr\u003e\n\nPlease note that the vulnerability can only be exploited by authenticated users, so customers are recommended to ensure that only authorized persons have access to user accounts for the computers where\nAdvaBuild is used.\n\u003cbr\u003e\u003cbr\u003eAll the vulnerabilities have been corrected in AdvaBuild version 3.7 SP3 released in April 2021.\n\u003cbr\u003e\u003cbr\u003eABB recommends that customers apply the update at earliest convenience. Users who are unable to install the update should immediately look to implement the \u201cMitigating factors\u201d listed below as this will\nrestrict or prevent an attacker\u2019s ability to compromise the system.\n\n\u003cbr\u003e"
            }
          ],
          "value": "ABB recommends changing any user account passwords which are suspected to be known by an unauthorized person. Interactive logon (both local and remote) is recommended to be disabled for service\naccounts.\n\n\n\n\nPlease note that the vulnerability can only be exploited by authenticated users, so customers are recommended to ensure that only authorized persons have access to user accounts for the computers where\nAdvaBuild is used.\n\n\nAll the vulnerabilities have been corrected in AdvaBuild version 3.7 SP3 released in April 2021.\n\n\nABB recommends that customers apply the update at earliest convenience. Users who are unable to install the update should immediately look to implement the \u201cMitigating factors\u201d listed below as this will\nrestrict or prevent an attacker\u2019s ability to compromise the system."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Elevation of Privilege",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-11640",
    "datePublished": "2024-07-23T17:36:51.458Z",
    "dateReserved": "2020-04-08T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:35:13.681Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-11639 (GCVE-0-2020-11639)

Vulnerability from nvd – Published: 2024-07-23 17:26 – Updated: 2024-08-04 11:35
VLAI?
Title
Insufficient access control on Inter process communication,
Summary
An attacker could exploit the vulnerability by injecting garbage data or specially crafted data. Depending on the data injected each process might be affected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing the product to store wrong information or act on wrong data or display wrong information. This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2. For an attack to be successful, the attacker must have local access to a node in the system and be able to start a specially crafted application that disrupts the communication. An attacker who successfully exploited the vulnerability would be able to manipulate the data in such way as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300 and AdvaBuild to crash.
CWE
  • CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
Assigner
ABB
Impacted products
Vendor Product Version
ABB Advant MOD 300 AdvaBuild Affected: 3.0 , ≤ 3.7 SP2 (update)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:abb:advabuild:3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "advabuild",
            "vendor": "abb",
            "versions": [
              {
                "lessThanOrEqual": "3.7_sp2",
                "status": "affected",
                "version": "3.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-11639",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-23T19:03:27.748360Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-23T19:10:57.887Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:35:13.593Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Advant MOD 300 AdvaBuild",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.7 SP2",
              "status": "affected",
              "version": "3.0",
              "versionType": "update"
            }
          ]
        }
      ],
      "datePublic": "2024-07-22T17:20:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nAn attacker could exploit the vulnerability by\ninjecting garbage data or specially crafted data. Depending on the data injected each process might be\naffected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing\nthe product to store wrong information or act on wrong data or display wrong information.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.\u003c/p\u003e\u003cp\u003e\u003cbr\u003e\n\nFor an attack to be successful, the attacker must have local access to a node in the system and be able to\nstart a specially crafted application that disrupts the communication.\nAn attacker who successfully exploited the vulnerability would be able to manipulate the data in such\nway as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300\nand AdvaBuild to crash.\n\n\n\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "An attacker could exploit the vulnerability by\ninjecting garbage data or specially crafted data. Depending on the data injected each process might be\naffected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing\nthe product to store wrong information or act on wrong data or display wrong information.\n\n\nThis issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.\n\n\n\n\nFor an attack to be successful, the attacker must have local access to a node in the system and be able to\nstart a specially crafted application that disrupts the communication.\nAn attacker who successfully exploited the vulnerability would be able to manipulate the data in such\nway as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300\nand AdvaBuild to crash."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-924",
              "description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-23T17:26:55.489Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nABB recommends changing any user account passwords which are suspected to be known by an unauthorized person. Interactive logon (both local and remote) is recommended to be disabled for service\naccounts.\n\n\u003cbr\u003e\n\nPlease note that the vulnerability can only be exploited by authenticated users, so customers are recommended to ensure that only authorized persons have access to user accounts for the computers where\nAdvaBuild is used.\n\u003cbr\u003e\u003cbr\u003eAll the vulnerabilities have been corrected in AdvaBuild version 3.7 SP3 released in April 2021.\n\u003cbr\u003e\u003cbr\u003eABB recommends that customers apply the update at earliest convenience. Users who are unable to install the update should immediately look to implement the \u201cMitigating factors\u201d listed below as this will\nrestrict or prevent an attacker\u2019s ability to compromise the system.\n\n\u003cbr\u003e"
            }
          ],
          "value": "ABB recommends changing any user account passwords which are suspected to be known by an unauthorized person. Interactive logon (both local and remote) is recommended to be disabled for service\naccounts.\n\n\n\n\nPlease note that the vulnerability can only be exploited by authenticated users, so customers are recommended to ensure that only authorized persons have access to user accounts for the computers where\nAdvaBuild is used.\n\n\nAll the vulnerabilities have been corrected in AdvaBuild version 3.7 SP3 released in April 2021.\n\n\nABB recommends that customers apply the update at earliest convenience. Users who are unable to install the update should immediately look to implement the \u201cMitigating factors\u201d listed below as this will\nrestrict or prevent an attacker\u2019s ability to compromise the system."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Insufficient access control on Inter process communication,",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-11639",
    "datePublished": "2024-07-23T17:26:55.489Z",
    "dateReserved": "2020-04-08T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:35:13.593Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-8481 (GCVE-0-2020-8481)

Vulnerability from nvd – Published: 2020-04-29 01:30 – Updated: 2024-08-04 10:03
VLAI?
Title
ABB Central Licensing System - Information disclosure
Summary
For ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer.
CWE
Assigner
ABB
Impacted products
Vendor Product Version
ABB Central Licensing System Affected: 5.1 , < 5* (custom)
Create a notification for this product.
    ABB ABB Ability System 800xA Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Compact HMI Affected: 5.1
Affected: 6.0
Create a notification for this product.
    ABB Control Builder Safe Affected: 1.0
Affected: 1.1
Affected: 2.0
Create a notification for this product.
    ABB Symphony Plus S+ Operations Affected: 3 , ≤ 3.2 (custom)
Create a notification for this product.
    ABB Symphony Plus S+ Engineering Affected: 1.1 , ≤ 2.2 (custom)
Create a notification for this product.
    ABB Composer Harmony Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Composer Melody Affected: 5.3
Affected: 6 , ≤ 6.3 (custom)
Create a notification for this product.
    ABB Harmony OPC Server Standalone Affected: 6.0
Affected: 6.1
Affected: 7.0
Create a notification for this product.
    ABB Advant OCS Control Builder A Affected: 1.3
Affected: 1.4
Create a notification for this product.
    ABB Composer CTK Affected: 6.1
Affected: 6.2
Create a notification for this product.
    ABB AdvaBuild Affected: 3.7 SP1
Affected: 3.7 SP2
Create a notification for this product.
    ABB OPC Server for Mod 300 (non-800xA) Affected: 1.4
Create a notification for this product.
    ABB OPC Data Link Affected: 2.1
Affected: 2.2
Create a notification for this product.
    ABB Knowledge Manager Affected: 8.0
Affected: 9.0
Affected: 9.1
Create a notification for this product.
    ABB Manufacturing Operations Management Affected: 1812
Affected: 1909
Create a notification for this product.
    ABB Advant OCS AC 100 OPS Server Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:03:45.868Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Central Licensing System",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "5*",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "ABB Ability System 800xA",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Compact HMI",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            }
          ]
        },
        {
          "product": "Control Builder Safe",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.0"
            },
            {
              "status": "affected",
              "version": "1.1"
            },
            {
              "status": "affected",
              "version": "2.0"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Operations",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.2",
              "status": "affected",
              "version": "3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Engineering ",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.2",
              "status": "affected",
              "version": "1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Composer Harmony",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Composer Melody ",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.3"
            },
            {
              "lessThanOrEqual": "6.3",
              "status": "affected",
              "version": "6",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Harmony OPC Server Standalone",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "7.0"
            }
          ]
        },
        {
          "product": "Advant OCS Control Builder A",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.3"
            },
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "Composer CTK",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "6.2"
            }
          ]
        },
        {
          "product": "AdvaBuild",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "3.7 SP1"
            },
            {
              "status": "affected",
              "version": "3.7 SP2"
            }
          ]
        },
        {
          "product": "OPC Server for Mod 300 (non-800xA)",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "OPC Data Link",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "2.1"
            },
            {
              "status": "affected",
              "version": "2.2"
            }
          ]
        },
        {
          "product": "Knowledge Manager",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "8.0"
            },
            {
              "status": "affected",
              "version": "9.0"
            },
            {
              "status": "affected",
              "version": "9.1"
            }
          ]
        },
        {
          "product": "Manufacturing Operations Management",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1812"
            },
            {
              "status": "affected",
              "version": "1909"
            }
          ]
        },
        {
          "product": "Advant  OCS AC 100 OPS Server",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "For ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-29T01:30:56",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ABB Central Licensing System - Information disclosure",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@ch.abb.com",
          "ID": "CVE-2020-8481",
          "STATE": "PUBLIC",
          "TITLE": "ABB Central Licensing System - Information disclosure"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Central Licensing System",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003e=",
                            "version_name": "5",
                            "version_value": "5.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "ABB Ability System 800xA",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Compact HMI",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Control Builder Safe",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "1.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Symphony Plus S+ Operations",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "3",
                            "version_value": "3.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Symphony Plus S+ Engineering ",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "1.1",
                            "version_value": "2.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Composer Harmony",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Composer Melody ",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.3"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "6",
                            "version_value": "6.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Harmony OPC Server Standalone",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "7.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Advant OCS Control Builder A",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1.3"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Composer CTK",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "AdvaBuild",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "3.7 SP1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "3.7 SP2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OPC Server for Mod 300 (non-800xA)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OPC Data Link",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "2.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Knowledge Manager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "8.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "9.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "9.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Manufacturing Operations Management",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1812"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "1909"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Advant  OCS AC 100 OPS Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ABB"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "For ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200 Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "CONFIRM",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "CONFIRM",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-8481",
    "datePublished": "2020-04-29T01:30:56",
    "dateReserved": "2020-01-30T00:00:00",
    "dateUpdated": "2024-08-04T10:03:45.868Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-8471 (GCVE-0-2020-8471)

Vulnerability from nvd – Published: 2020-04-29 01:30 – Updated: 2024-08-04 10:03
VLAI?
Title
ABB Central Licensing System - Weak File Permissions
Summary
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code.
CWE
Assigner
ABB
Impacted products
Vendor Product Version
ABB Central Licensing System Affected: 5.1 , < 5* (custom)
Create a notification for this product.
    ABB ABB Ability System 800xA Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Compact HMI Affected: 5.1
Affected: 6.0
Create a notification for this product.
    ABB Control Builder Safe Affected: 1.0
Affected: 1.1
Affected: 2.0
Create a notification for this product.
    ABB Symphony Plus S+ Operations Affected: 3 , ≤ 3.2 (custom)
Create a notification for this product.
    ABB Symphony Plus S+ Engineering Affected: 1.1 , ≤ 2.2 (custom)
Create a notification for this product.
    ABB Composer Harmony Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Composer Melody Affected: 5.3
Affected: 6 , ≤ 6.3 (custom)
Create a notification for this product.
    ABB Harmony OPC Server Standalone Affected: 6.0
Affected: 6.1
Affected: 7.0
Create a notification for this product.
    ABB Advant OCS Control Builder A Affected: 1.3
Affected: 1.4
Create a notification for this product.
    ABB Composer CTK Affected: 6.1
Affected: 6.2
Create a notification for this product.
    ABB AdvaBuild Affected: 3.7 SP1
Affected: 3.7 SP2
Create a notification for this product.
    ABB OPC Server for Mod 300 (non-800xA) Affected: 1.4
Create a notification for this product.
    ABB OPC Data Link Affected: 2.1
Affected: 2.2
Create a notification for this product.
    ABB Knowledge Manager Affected: 8.0
Affected: 9.0
Affected: 9.1
Create a notification for this product.
    ABB Manufacturing Operations Management Affected: 1812
Affected: 1909
Create a notification for this product.
    ABB Advant OCS AC 100 OPS Server Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:03:44.886Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-154-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Central Licensing System",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "5*",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "ABB Ability System 800xA",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Compact HMI",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            }
          ]
        },
        {
          "product": "Control Builder Safe",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.0"
            },
            {
              "status": "affected",
              "version": "1.1"
            },
            {
              "status": "affected",
              "version": "2.0"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Operations",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.2",
              "status": "affected",
              "version": "3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Engineering ",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.2",
              "status": "affected",
              "version": "1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Composer Harmony",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Composer Melody ",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.3"
            },
            {
              "lessThanOrEqual": "6.3",
              "status": "affected",
              "version": "6",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Harmony OPC Server Standalone",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "7.0"
            }
          ]
        },
        {
          "product": "Advant OCS Control Builder A",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.3"
            },
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "Composer CTK",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "6.2"
            }
          ]
        },
        {
          "product": "AdvaBuild",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "3.7 SP1"
            },
            {
              "status": "affected",
              "version": "3.7 SP2"
            }
          ]
        },
        {
          "product": "OPC Server for Mod 300 (non-800xA)",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "OPC Data Link",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "2.1"
            },
            {
              "status": "affected",
              "version": "2.2"
            }
          ]
        },
        {
          "product": "Knowledge Manager",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "8.0"
            },
            {
              "status": "affected",
              "version": "9.0"
            },
            {
              "status": "affected",
              "version": "9.1"
            }
          ]
        },
        {
          "product": "Manufacturing Operations Management",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1812"
            },
            {
              "status": "affected",
              "version": "1909"
            }
          ]
        },
        {
          "product": "Advant  OCS AC 100 OPS Server",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "For the Central Licensing Server component used in ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-275",
              "description": "CWE-275 Permission Issues",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-06-09T16:16:51",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-154-04"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ABB Central Licensing System - Weak File Permissions",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@ch.abb.com",
          "ID": "CVE-2020-8471",
          "STATE": "PUBLIC",
          "TITLE": "ABB Central Licensing System - Weak File Permissions"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Central Licensing System",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003e=",
                            "version_name": "5",
                            "version_value": "5.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "ABB Ability System 800xA",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Compact HMI",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Control Builder Safe",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "1.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Symphony Plus S+ Operations",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "3",
                            "version_value": "3.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Symphony Plus S+ Engineering ",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "1.1",
                            "version_value": "2.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Composer Harmony",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Composer Melody ",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.3"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "6",
                            "version_value": "6.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Harmony OPC Server Standalone",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "7.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Advant OCS Control Builder A",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1.3"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Composer CTK",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "AdvaBuild",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "3.7 SP1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "3.7 SP2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OPC Server for Mod 300 (non-800xA)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OPC Data Link",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "2.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Knowledge Manager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "8.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "9.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "9.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Manufacturing Operations Management",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1812"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "1909"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Advant  OCS AC 100 OPS Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ABB"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "For the Central Licensing Server component used in ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-275 Permission Issues"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "CONFIRM",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "CONFIRM",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-154-04",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-154-04"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-8471",
    "datePublished": "2020-04-29T01:30:43",
    "dateReserved": "2020-01-30T00:00:00",
    "dateUpdated": "2024-08-04T10:03:44.886Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-8476 (GCVE-0-2020-8476)

Vulnerability from nvd – Published: 2020-04-29 00:00 – Updated: 2024-08-04 10:03
VLAI?
Title
ABB Central Licensing System - Elevation of Privilege Vulnerability
Summary
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service.
CWE
  • CWE-20 - Improper Input Validation
Assigner
ABB
Impacted products
Vendor Product Version
ABB Central Licensing System Affected: 5.1 , < 5* (custom)
Create a notification for this product.
    ABB ABB Ability System 800xA Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Compact HMI Affected: 5.1
Affected: 6.0
Create a notification for this product.
    ABB Control Builder Safe Affected: 1.0
Affected: 1.1
Affected: 2.0
Create a notification for this product.
    ABB Symphony Plus S+ Operations Affected: 3 , ≤ 3.2 (custom)
Create a notification for this product.
    ABB Symphony Plus S+ Engineering Affected: 1.1 , ≤ 2.2 (custom)
Create a notification for this product.
    ABB Composer Harmony Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Composer Melody Affected: 5.3
Affected: 6 , ≤ 6.3 (custom)
Create a notification for this product.
    ABB Harmony OPC Server Standalone Affected: 6.0
Affected: 6.1
Affected: 7.0
Create a notification for this product.
    ABB Advant OCS Control Builder A Affected: 1.3
Affected: 1.4
Create a notification for this product.
    ABB Composer CTK Affected: 6.1
Affected: 6.2
Create a notification for this product.
    ABB AdvaBuild Affected: 3.7 SP1
Affected: 3.7 SP2
Create a notification for this product.
    ABB OPC Server for Mod 300 (non-800xA) Affected: 1.4
Create a notification for this product.
    ABB OPC Data Link Affected: 2.1
Affected: 2.2
Create a notification for this product.
    ABB Knowledge Manager Affected: 8.0
Affected: 9.0
Affected: 9.1
Create a notification for this product.
    ABB Manufacturing Operations Management Affected: 1812
Affected: 1909
Create a notification for this product.
    ABB Advant OCS AC 100 OPS Server Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB ABB Ability™ SCADAvantage Affected: 5.1 , < unspecified (custom)
Affected: unspecified , ≤ 5.6.5 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:03:45.851Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Central Licensing System",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "5*",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "ABB Ability System 800xA",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Compact HMI",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            }
          ]
        },
        {
          "product": "Control Builder Safe",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.0"
            },
            {
              "status": "affected",
              "version": "1.1"
            },
            {
              "status": "affected",
              "version": "2.0"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Operations",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.2",
              "status": "affected",
              "version": "3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Engineering ",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.2",
              "status": "affected",
              "version": "1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Composer Harmony",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Composer Melody ",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.3"
            },
            {
              "lessThanOrEqual": "6.3",
              "status": "affected",
              "version": "6",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Harmony OPC Server Standalone",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "7.0"
            }
          ]
        },
        {
          "product": "Advant OCS Control Builder A",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.3"
            },
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "Composer CTK",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "6.2"
            }
          ]
        },
        {
          "product": "AdvaBuild",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "3.7 SP1"
            },
            {
              "status": "affected",
              "version": "3.7 SP2"
            }
          ]
        },
        {
          "product": "OPC Server for Mod 300 (non-800xA)",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "OPC Data Link",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "2.1"
            },
            {
              "status": "affected",
              "version": "2.2"
            }
          ]
        },
        {
          "product": "Knowledge Manager",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "8.0"
            },
            {
              "status": "affected",
              "version": "9.0"
            },
            {
              "status": "affected",
              "version": "9.1"
            }
          ]
        },
        {
          "product": "Manufacturing Operations Management",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1812"
            },
            {
              "status": "affected",
              "version": "1909"
            }
          ]
        },
        {
          "product": "Advant  OCS AC 100 OPS Server",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "ABB  Ability\u2122 SCADAvantage",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "unspecified",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "5.6.5",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "For the Central Licensing Server component used in ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-28T00:00:00",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ABB Central Licensing System - Elevation of Privilege Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-8476",
    "datePublished": "2020-04-29T00:00:00",
    "dateReserved": "2020-01-30T00:00:00",
    "dateUpdated": "2024-08-04T10:03:45.851Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-8475 (GCVE-0-2020-8475)

Vulnerability from nvd – Published: 2020-04-29 00:00 – Updated: 2024-08-04 10:03
VLAI?
Title
ABB Central Licensing System - Denial of Service Vulnerability
Summary
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to block license handling by sending specially crafted messages to the CLS web service.
CWE
  • CWE-20 - Improper Input Validation
Assigner
ABB
Impacted products
Vendor Product Version
ABB Central Licensing System Affected: 5.1 , < 5* (custom)
Create a notification for this product.
    ABB ABB Ability System 800xA Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Compact HMI Affected: 5.1
Affected: 6.0
Create a notification for this product.
    ABB Control Builder Safe Affected: 1.0
Affected: 1.1
Affected: 2.0
Create a notification for this product.
    ABB Symphony Plus S+ Operations Affected: 3 , ≤ 3.2 (custom)
Create a notification for this product.
    ABB Symphony Plus S+ Engineering Affected: 1.1 , ≤ 2.2 (custom)
Create a notification for this product.
    ABB Composer Harmony Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Composer Melody Affected: 5.3
Affected: 6 , ≤ 6.3 (custom)
Create a notification for this product.
    ABB Harmony OPC Server Standalone Affected: 6.0
Affected: 6.1
Affected: 7.0
Create a notification for this product.
    ABB Advant OCS Control Builder A Affected: 1.3
Affected: 1.4
Create a notification for this product.
    ABB Composer CTK Affected: 6.1
Affected: 6.2
Create a notification for this product.
    ABB AdvaBuild Affected: 3.7 SP1
Affected: 3.7 SP2
Create a notification for this product.
    ABB OPC Server for Mod 300 (non-800xA) Affected: 1.4
Create a notification for this product.
    ABB OPC Data Link Affected: 2.1
Affected: 2.2
Create a notification for this product.
    ABB Knowledge Manager Affected: 8.0
Affected: 9.0
Affected: 9.1
Create a notification for this product.
    ABB Manufacturing Operations Management Affected: 1812
Affected: 1909
Create a notification for this product.
    ABB Advant OCS AC 100 OPS Server Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB ABB Ability™ SCADAvantage Affected: 5.1 , < unspecified (custom)
Affected: unspecified , ≤ 5.6.5 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:03:44.814Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Central Licensing System",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "5*",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "ABB Ability System 800xA",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Compact HMI",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            }
          ]
        },
        {
          "product": "Control Builder Safe",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.0"
            },
            {
              "status": "affected",
              "version": "1.1"
            },
            {
              "status": "affected",
              "version": "2.0"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Operations",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.2",
              "status": "affected",
              "version": "3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Engineering ",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.2",
              "status": "affected",
              "version": "1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Composer Harmony",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Composer Melody ",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.3"
            },
            {
              "lessThanOrEqual": "6.3",
              "status": "affected",
              "version": "6",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Harmony OPC Server Standalone",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "7.0"
            }
          ]
        },
        {
          "product": "Advant OCS Control Builder A",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.3"
            },
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "Composer CTK",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "6.2"
            }
          ]
        },
        {
          "product": "AdvaBuild",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "3.7 SP1"
            },
            {
              "status": "affected",
              "version": "3.7 SP2"
            }
          ]
        },
        {
          "product": "OPC Server for Mod 300 (non-800xA)",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "OPC Data Link",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "2.1"
            },
            {
              "status": "affected",
              "version": "2.2"
            }
          ]
        },
        {
          "product": "Knowledge Manager",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "8.0"
            },
            {
              "status": "affected",
              "version": "9.0"
            },
            {
              "status": "affected",
              "version": "9.1"
            }
          ]
        },
        {
          "product": "Manufacturing Operations Management",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1812"
            },
            {
              "status": "affected",
              "version": "1909"
            }
          ]
        },
        {
          "product": "Advant  OCS AC 100 OPS Server",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "ABB  Ability\u2122 SCADAvantage",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "unspecified",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "5.6.5",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "For the Central Licensing Server component used in ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to block license handling by sending specially crafted messages to the CLS web service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-28T00:00:00",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ABB Central Licensing System - Denial of Service Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-8475",
    "datePublished": "2020-04-29T00:00:00",
    "dateReserved": "2020-01-30T00:00:00",
    "dateUpdated": "2024-08-04T10:03:44.814Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-8479 (GCVE-0-2020-8479)

Vulnerability from nvd – Published: 2020-04-29 00:00 – Updated: 2024-08-04 10:03
VLAI?
Title
ABB Central Licensing System - XML External Entity Injection
Summary
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5. an XML External Entity Injection vulnerability exists that allows an attacker to read or call arbitrary files from the license server and/or from the network and also block the license handling.
CWE
  • CWE-91 - XML Injection (aka Blind XPath Injection)
Assigner
ABB
Impacted products
Vendor Product Version
ABB Central Licensing System Affected: 5.1 , < 5* (custom)
Create a notification for this product.
    ABB ABB Ability System 800xA Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Compact HMI Affected: 5.1
Affected: 6.0
Create a notification for this product.
    ABB Control Builder Safe Affected: 1.0
Affected: 1.1
Affected: 2.0
Create a notification for this product.
    ABB Symphony Plus S+ Operations Affected: 3 , ≤ 3.2 (custom)
Create a notification for this product.
    ABB Symphony Plus S+ Engineering Affected: 1.1 , ≤ 2.2 (custom)
Create a notification for this product.
    ABB Composer Harmony Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Composer Melody Affected: 5.3
Affected: 6 , ≤ 6.3 (custom)
Create a notification for this product.
    ABB Harmony OPC Server Standalone Affected: 6.0
Affected: 6.1
Affected: 7.0
Create a notification for this product.
    ABB Advant OCS Control Builder A Affected: 1.3
Affected: 1.4
Create a notification for this product.
    ABB Composer CTK Affected: 6.1
Affected: 6.2
Create a notification for this product.
    ABB AdvaBuild Affected: 3.7 SP1
Affected: 3.7 SP2
Create a notification for this product.
    ABB OPC Server for Mod 300 (non-800xA) Affected: 1.4
Create a notification for this product.
    ABB OPC Data Link Affected: 2.1
Affected: 2.2
Create a notification for this product.
    ABB Knowledge Manager Affected: 8.0
Affected: 9.0
Affected: 9.1
Create a notification for this product.
    ABB Manufacturing Operations Management Affected: 1812
Affected: 1909
Create a notification for this product.
    ABB Advant OCS AC 100 OPS Server Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB ABB Ability™ SCADAvantage Affected: 5.1 , < unspecified (custom)
Affected: unspecified , ≤ 5.6.5 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:03:44.804Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Central Licensing System",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "5*",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "ABB Ability System 800xA",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Compact HMI",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            }
          ]
        },
        {
          "product": "Control Builder Safe",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.0"
            },
            {
              "status": "affected",
              "version": "1.1"
            },
            {
              "status": "affected",
              "version": "2.0"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Operations",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.2",
              "status": "affected",
              "version": "3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Engineering ",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.2",
              "status": "affected",
              "version": "1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Composer Harmony",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Composer Melody ",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.3"
            },
            {
              "lessThanOrEqual": "6.3",
              "status": "affected",
              "version": "6",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Harmony OPC Server Standalone",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "7.0"
            }
          ]
        },
        {
          "product": "Advant OCS Control Builder A",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.3"
            },
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "Composer CTK",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "6.2"
            }
          ]
        },
        {
          "product": "AdvaBuild",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "3.7 SP1"
            },
            {
              "status": "affected",
              "version": "3.7 SP2"
            }
          ]
        },
        {
          "product": "OPC Server for Mod 300 (non-800xA)",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "OPC Data Link",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "2.1"
            },
            {
              "status": "affected",
              "version": "2.2"
            }
          ]
        },
        {
          "product": "Knowledge Manager",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "8.0"
            },
            {
              "status": "affected",
              "version": "9.0"
            },
            {
              "status": "affected",
              "version": "9.1"
            }
          ]
        },
        {
          "product": "Manufacturing Operations Management",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1812"
            },
            {
              "status": "affected",
              "version": "1909"
            }
          ]
        },
        {
          "product": "Advant  OCS AC 100 OPS Server",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "ABB  Ability\u2122 SCADAvantage",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "unspecified",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "5.6.5",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "For the Central Licensing Server component used in ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5. an XML External Entity Injection vulnerability exists that allows an attacker to read or call arbitrary files from the license server and/or from the network and also block the license handling."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-91",
              "description": "CWE-91 XML Injection (aka Blind XPath Injection)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-28T00:00:00",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ABB Central Licensing System - XML External Entity Injection",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-8479",
    "datePublished": "2020-04-29T00:00:00",
    "dateReserved": "2020-01-30T00:00:00",
    "dateUpdated": "2024-08-04T10:03:44.804Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-11640 (GCVE-0-2020-11640)

Vulnerability from cvelistv5 – Published: 2024-07-23 17:36 – Updated: 2024-08-04 11:35
VLAI?
Title
Elevation of Privilege
Summary
AdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the command queue can use it to launch an attack by running any executable on the AdvaBuild node. The executables that can be run are not limited to AdvaBuild specific executables.  Improper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
ABB
Impacted products
Vendor Product Version
ABB Advant MOD 300 AdvaBuild Affected: 3.0 , ≤ 3.7 SP2 (update)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:abb:advabuild:*:*:*:*:*:*:mod_300:*"
            ],
            "defaultStatus": "unknown",
            "product": "advabuild",
            "vendor": "abb",
            "versions": [
              {
                "lessThanOrEqual": "3.7sp2",
                "status": "affected",
                "version": "3.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-11640",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-23T18:09:49.474898Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-24T19:00:53.120Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:35:13.681Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Advant MOD 300 AdvaBuild",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.7 SP2",
              "status": "affected",
              "version": "3.0",
              "versionType": "update"
            }
          ]
        }
      ],
      "datePublic": "2024-07-22T17:33:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nAdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the\ncommand queue can use it to launch an attack by running any executable on the AdvaBuild node. The\nexecutables that can be run are not limited to AdvaBuild specific executables.\u0026nbsp;\u003cbr\u003e\u003cbr\u003eImproper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.\u003cp\u003eThis issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.\u003c/p\u003e"
            }
          ],
          "value": "AdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the\ncommand queue can use it to launch an attack by running any executable on the AdvaBuild node. The\nexecutables that can be run are not limited to AdvaBuild specific executables.\u00a0\n\nImproper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-23T17:36:51.458Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nABB recommends changing any user account passwords which are suspected to be known by an unauthorized person. Interactive logon (both local and remote) is recommended to be disabled for service\naccounts.\n\n\u003cbr\u003e\n\nPlease note that the vulnerability can only be exploited by authenticated users, so customers are recommended to ensure that only authorized persons have access to user accounts for the computers where\nAdvaBuild is used.\n\u003cbr\u003e\u003cbr\u003eAll the vulnerabilities have been corrected in AdvaBuild version 3.7 SP3 released in April 2021.\n\u003cbr\u003e\u003cbr\u003eABB recommends that customers apply the update at earliest convenience. Users who are unable to install the update should immediately look to implement the \u201cMitigating factors\u201d listed below as this will\nrestrict or prevent an attacker\u2019s ability to compromise the system.\n\n\u003cbr\u003e"
            }
          ],
          "value": "ABB recommends changing any user account passwords which are suspected to be known by an unauthorized person. Interactive logon (both local and remote) is recommended to be disabled for service\naccounts.\n\n\n\n\nPlease note that the vulnerability can only be exploited by authenticated users, so customers are recommended to ensure that only authorized persons have access to user accounts for the computers where\nAdvaBuild is used.\n\n\nAll the vulnerabilities have been corrected in AdvaBuild version 3.7 SP3 released in April 2021.\n\n\nABB recommends that customers apply the update at earliest convenience. Users who are unable to install the update should immediately look to implement the \u201cMitigating factors\u201d listed below as this will\nrestrict or prevent an attacker\u2019s ability to compromise the system."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Elevation of Privilege",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-11640",
    "datePublished": "2024-07-23T17:36:51.458Z",
    "dateReserved": "2020-04-08T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:35:13.681Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-11639 (GCVE-0-2020-11639)

Vulnerability from cvelistv5 – Published: 2024-07-23 17:26 – Updated: 2024-08-04 11:35
VLAI?
Title
Insufficient access control on Inter process communication,
Summary
An attacker could exploit the vulnerability by injecting garbage data or specially crafted data. Depending on the data injected each process might be affected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing the product to store wrong information or act on wrong data or display wrong information. This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2. For an attack to be successful, the attacker must have local access to a node in the system and be able to start a specially crafted application that disrupts the communication. An attacker who successfully exploited the vulnerability would be able to manipulate the data in such way as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300 and AdvaBuild to crash.
CWE
  • CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
Assigner
ABB
Impacted products
Vendor Product Version
ABB Advant MOD 300 AdvaBuild Affected: 3.0 , ≤ 3.7 SP2 (update)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:abb:advabuild:3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "advabuild",
            "vendor": "abb",
            "versions": [
              {
                "lessThanOrEqual": "3.7_sp2",
                "status": "affected",
                "version": "3.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-11639",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-23T19:03:27.748360Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-23T19:10:57.887Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:35:13.593Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Advant MOD 300 AdvaBuild",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.7 SP2",
              "status": "affected",
              "version": "3.0",
              "versionType": "update"
            }
          ]
        }
      ],
      "datePublic": "2024-07-22T17:20:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nAn attacker could exploit the vulnerability by\ninjecting garbage data or specially crafted data. Depending on the data injected each process might be\naffected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing\nthe product to store wrong information or act on wrong data or display wrong information.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.\u003c/p\u003e\u003cp\u003e\u003cbr\u003e\n\nFor an attack to be successful, the attacker must have local access to a node in the system and be able to\nstart a specially crafted application that disrupts the communication.\nAn attacker who successfully exploited the vulnerability would be able to manipulate the data in such\nway as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300\nand AdvaBuild to crash.\n\n\n\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "An attacker could exploit the vulnerability by\ninjecting garbage data or specially crafted data. Depending on the data injected each process might be\naffected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing\nthe product to store wrong information or act on wrong data or display wrong information.\n\n\nThis issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.\n\n\n\n\nFor an attack to be successful, the attacker must have local access to a node in the system and be able to\nstart a specially crafted application that disrupts the communication.\nAn attacker who successfully exploited the vulnerability would be able to manipulate the data in such\nway as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300\nand AdvaBuild to crash."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-924",
              "description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-23T17:26:55.489Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUA003421\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.200044199.882581162.1721753430-284724496.1718609177"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nABB recommends changing any user account passwords which are suspected to be known by an unauthorized person. Interactive logon (both local and remote) is recommended to be disabled for service\naccounts.\n\n\u003cbr\u003e\n\nPlease note that the vulnerability can only be exploited by authenticated users, so customers are recommended to ensure that only authorized persons have access to user accounts for the computers where\nAdvaBuild is used.\n\u003cbr\u003e\u003cbr\u003eAll the vulnerabilities have been corrected in AdvaBuild version 3.7 SP3 released in April 2021.\n\u003cbr\u003e\u003cbr\u003eABB recommends that customers apply the update at earliest convenience. Users who are unable to install the update should immediately look to implement the \u201cMitigating factors\u201d listed below as this will\nrestrict or prevent an attacker\u2019s ability to compromise the system.\n\n\u003cbr\u003e"
            }
          ],
          "value": "ABB recommends changing any user account passwords which are suspected to be known by an unauthorized person. Interactive logon (both local and remote) is recommended to be disabled for service\naccounts.\n\n\n\n\nPlease note that the vulnerability can only be exploited by authenticated users, so customers are recommended to ensure that only authorized persons have access to user accounts for the computers where\nAdvaBuild is used.\n\n\nAll the vulnerabilities have been corrected in AdvaBuild version 3.7 SP3 released in April 2021.\n\n\nABB recommends that customers apply the update at earliest convenience. Users who are unable to install the update should immediately look to implement the \u201cMitigating factors\u201d listed below as this will\nrestrict or prevent an attacker\u2019s ability to compromise the system."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Insufficient access control on Inter process communication,",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-11639",
    "datePublished": "2024-07-23T17:26:55.489Z",
    "dateReserved": "2020-04-08T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:35:13.593Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-8481 (GCVE-0-2020-8481)

Vulnerability from cvelistv5 – Published: 2020-04-29 01:30 – Updated: 2024-08-04 10:03
VLAI?
Title
ABB Central Licensing System - Information disclosure
Summary
For ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer.
CWE
Assigner
ABB
Impacted products
Vendor Product Version
ABB Central Licensing System Affected: 5.1 , < 5* (custom)
Create a notification for this product.
    ABB ABB Ability System 800xA Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Compact HMI Affected: 5.1
Affected: 6.0
Create a notification for this product.
    ABB Control Builder Safe Affected: 1.0
Affected: 1.1
Affected: 2.0
Create a notification for this product.
    ABB Symphony Plus S+ Operations Affected: 3 , ≤ 3.2 (custom)
Create a notification for this product.
    ABB Symphony Plus S+ Engineering Affected: 1.1 , ≤ 2.2 (custom)
Create a notification for this product.
    ABB Composer Harmony Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Composer Melody Affected: 5.3
Affected: 6 , ≤ 6.3 (custom)
Create a notification for this product.
    ABB Harmony OPC Server Standalone Affected: 6.0
Affected: 6.1
Affected: 7.0
Create a notification for this product.
    ABB Advant OCS Control Builder A Affected: 1.3
Affected: 1.4
Create a notification for this product.
    ABB Composer CTK Affected: 6.1
Affected: 6.2
Create a notification for this product.
    ABB AdvaBuild Affected: 3.7 SP1
Affected: 3.7 SP2
Create a notification for this product.
    ABB OPC Server for Mod 300 (non-800xA) Affected: 1.4
Create a notification for this product.
    ABB OPC Data Link Affected: 2.1
Affected: 2.2
Create a notification for this product.
    ABB Knowledge Manager Affected: 8.0
Affected: 9.0
Affected: 9.1
Create a notification for this product.
    ABB Manufacturing Operations Management Affected: 1812
Affected: 1909
Create a notification for this product.
    ABB Advant OCS AC 100 OPS Server Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:03:45.868Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Central Licensing System",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "5*",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "ABB Ability System 800xA",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Compact HMI",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            }
          ]
        },
        {
          "product": "Control Builder Safe",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.0"
            },
            {
              "status": "affected",
              "version": "1.1"
            },
            {
              "status": "affected",
              "version": "2.0"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Operations",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.2",
              "status": "affected",
              "version": "3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Engineering ",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.2",
              "status": "affected",
              "version": "1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Composer Harmony",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Composer Melody ",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.3"
            },
            {
              "lessThanOrEqual": "6.3",
              "status": "affected",
              "version": "6",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Harmony OPC Server Standalone",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "7.0"
            }
          ]
        },
        {
          "product": "Advant OCS Control Builder A",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.3"
            },
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "Composer CTK",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "6.2"
            }
          ]
        },
        {
          "product": "AdvaBuild",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "3.7 SP1"
            },
            {
              "status": "affected",
              "version": "3.7 SP2"
            }
          ]
        },
        {
          "product": "OPC Server for Mod 300 (non-800xA)",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "OPC Data Link",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "2.1"
            },
            {
              "status": "affected",
              "version": "2.2"
            }
          ]
        },
        {
          "product": "Knowledge Manager",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "8.0"
            },
            {
              "status": "affected",
              "version": "9.0"
            },
            {
              "status": "affected",
              "version": "9.1"
            }
          ]
        },
        {
          "product": "Manufacturing Operations Management",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1812"
            },
            {
              "status": "affected",
              "version": "1909"
            }
          ]
        },
        {
          "product": "Advant  OCS AC 100 OPS Server",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "For ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-29T01:30:56",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ABB Central Licensing System - Information disclosure",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@ch.abb.com",
          "ID": "CVE-2020-8481",
          "STATE": "PUBLIC",
          "TITLE": "ABB Central Licensing System - Information disclosure"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Central Licensing System",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003e=",
                            "version_name": "5",
                            "version_value": "5.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "ABB Ability System 800xA",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Compact HMI",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Control Builder Safe",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "1.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Symphony Plus S+ Operations",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "3",
                            "version_value": "3.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Symphony Plus S+ Engineering ",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "1.1",
                            "version_value": "2.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Composer Harmony",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Composer Melody ",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.3"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "6",
                            "version_value": "6.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Harmony OPC Server Standalone",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "7.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Advant OCS Control Builder A",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1.3"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Composer CTK",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "AdvaBuild",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "3.7 SP1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "3.7 SP2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OPC Server for Mod 300 (non-800xA)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OPC Data Link",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "2.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Knowledge Manager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "8.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "9.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "9.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Manufacturing Operations Management",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1812"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "1909"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Advant  OCS AC 100 OPS Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ABB"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "For ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200 Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "CONFIRM",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "CONFIRM",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-8481",
    "datePublished": "2020-04-29T01:30:56",
    "dateReserved": "2020-01-30T00:00:00",
    "dateUpdated": "2024-08-04T10:03:45.868Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-8471 (GCVE-0-2020-8471)

Vulnerability from cvelistv5 – Published: 2020-04-29 01:30 – Updated: 2024-08-04 10:03
VLAI?
Title
ABB Central Licensing System - Weak File Permissions
Summary
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code.
CWE
Assigner
ABB
Impacted products
Vendor Product Version
ABB Central Licensing System Affected: 5.1 , < 5* (custom)
Create a notification for this product.
    ABB ABB Ability System 800xA Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Compact HMI Affected: 5.1
Affected: 6.0
Create a notification for this product.
    ABB Control Builder Safe Affected: 1.0
Affected: 1.1
Affected: 2.0
Create a notification for this product.
    ABB Symphony Plus S+ Operations Affected: 3 , ≤ 3.2 (custom)
Create a notification for this product.
    ABB Symphony Plus S+ Engineering Affected: 1.1 , ≤ 2.2 (custom)
Create a notification for this product.
    ABB Composer Harmony Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Composer Melody Affected: 5.3
Affected: 6 , ≤ 6.3 (custom)
Create a notification for this product.
    ABB Harmony OPC Server Standalone Affected: 6.0
Affected: 6.1
Affected: 7.0
Create a notification for this product.
    ABB Advant OCS Control Builder A Affected: 1.3
Affected: 1.4
Create a notification for this product.
    ABB Composer CTK Affected: 6.1
Affected: 6.2
Create a notification for this product.
    ABB AdvaBuild Affected: 3.7 SP1
Affected: 3.7 SP2
Create a notification for this product.
    ABB OPC Server for Mod 300 (non-800xA) Affected: 1.4
Create a notification for this product.
    ABB OPC Data Link Affected: 2.1
Affected: 2.2
Create a notification for this product.
    ABB Knowledge Manager Affected: 8.0
Affected: 9.0
Affected: 9.1
Create a notification for this product.
    ABB Manufacturing Operations Management Affected: 1812
Affected: 1909
Create a notification for this product.
    ABB Advant OCS AC 100 OPS Server Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:03:44.886Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-154-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Central Licensing System",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "5*",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "ABB Ability System 800xA",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Compact HMI",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            }
          ]
        },
        {
          "product": "Control Builder Safe",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.0"
            },
            {
              "status": "affected",
              "version": "1.1"
            },
            {
              "status": "affected",
              "version": "2.0"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Operations",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.2",
              "status": "affected",
              "version": "3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Engineering ",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.2",
              "status": "affected",
              "version": "1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Composer Harmony",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Composer Melody ",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.3"
            },
            {
              "lessThanOrEqual": "6.3",
              "status": "affected",
              "version": "6",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Harmony OPC Server Standalone",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "7.0"
            }
          ]
        },
        {
          "product": "Advant OCS Control Builder A",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.3"
            },
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "Composer CTK",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "6.2"
            }
          ]
        },
        {
          "product": "AdvaBuild",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "3.7 SP1"
            },
            {
              "status": "affected",
              "version": "3.7 SP2"
            }
          ]
        },
        {
          "product": "OPC Server for Mod 300 (non-800xA)",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "OPC Data Link",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "2.1"
            },
            {
              "status": "affected",
              "version": "2.2"
            }
          ]
        },
        {
          "product": "Knowledge Manager",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "8.0"
            },
            {
              "status": "affected",
              "version": "9.0"
            },
            {
              "status": "affected",
              "version": "9.1"
            }
          ]
        },
        {
          "product": "Manufacturing Operations Management",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1812"
            },
            {
              "status": "affected",
              "version": "1909"
            }
          ]
        },
        {
          "product": "Advant  OCS AC 100 OPS Server",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "For the Central Licensing Server component used in ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-275",
              "description": "CWE-275 Permission Issues",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-06-09T16:16:51",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-154-04"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ABB Central Licensing System - Weak File Permissions",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@ch.abb.com",
          "ID": "CVE-2020-8471",
          "STATE": "PUBLIC",
          "TITLE": "ABB Central Licensing System - Weak File Permissions"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Central Licensing System",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003e=",
                            "version_name": "5",
                            "version_value": "5.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "ABB Ability System 800xA",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Compact HMI",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Control Builder Safe",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "1.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Symphony Plus S+ Operations",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "3",
                            "version_value": "3.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Symphony Plus S+ Engineering ",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "1.1",
                            "version_value": "2.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Composer Harmony",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Composer Melody ",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.3"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "6",
                            "version_value": "6.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Harmony OPC Server Standalone",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "7.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Advant OCS Control Builder A",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1.3"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Composer CTK",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "AdvaBuild",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "3.7 SP1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "3.7 SP2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OPC Server for Mod 300 (non-800xA)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OPC Data Link",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "2.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "2.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Knowledge Manager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "8.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "9.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "9.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Manufacturing Operations Management",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "1812"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "1909"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Advant  OCS AC 100 OPS Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "5.1"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.0"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "6.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ABB"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "For the Central Licensing Server component used in ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-275 Permission Issues"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "CONFIRM",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "CONFIRM",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-154-04",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-154-04"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-8471",
    "datePublished": "2020-04-29T01:30:43",
    "dateReserved": "2020-01-30T00:00:00",
    "dateUpdated": "2024-08-04T10:03:44.886Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-8476 (GCVE-0-2020-8476)

Vulnerability from cvelistv5 – Published: 2020-04-29 00:00 – Updated: 2024-08-04 10:03
VLAI?
Title
ABB Central Licensing System - Elevation of Privilege Vulnerability
Summary
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service.
CWE
  • CWE-20 - Improper Input Validation
Assigner
ABB
Impacted products
Vendor Product Version
ABB Central Licensing System Affected: 5.1 , < 5* (custom)
Create a notification for this product.
    ABB ABB Ability System 800xA Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Compact HMI Affected: 5.1
Affected: 6.0
Create a notification for this product.
    ABB Control Builder Safe Affected: 1.0
Affected: 1.1
Affected: 2.0
Create a notification for this product.
    ABB Symphony Plus S+ Operations Affected: 3 , ≤ 3.2 (custom)
Create a notification for this product.
    ABB Symphony Plus S+ Engineering Affected: 1.1 , ≤ 2.2 (custom)
Create a notification for this product.
    ABB Composer Harmony Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Composer Melody Affected: 5.3
Affected: 6 , ≤ 6.3 (custom)
Create a notification for this product.
    ABB Harmony OPC Server Standalone Affected: 6.0
Affected: 6.1
Affected: 7.0
Create a notification for this product.
    ABB Advant OCS Control Builder A Affected: 1.3
Affected: 1.4
Create a notification for this product.
    ABB Composer CTK Affected: 6.1
Affected: 6.2
Create a notification for this product.
    ABB AdvaBuild Affected: 3.7 SP1
Affected: 3.7 SP2
Create a notification for this product.
    ABB OPC Server for Mod 300 (non-800xA) Affected: 1.4
Create a notification for this product.
    ABB OPC Data Link Affected: 2.1
Affected: 2.2
Create a notification for this product.
    ABB Knowledge Manager Affected: 8.0
Affected: 9.0
Affected: 9.1
Create a notification for this product.
    ABB Manufacturing Operations Management Affected: 1812
Affected: 1909
Create a notification for this product.
    ABB Advant OCS AC 100 OPS Server Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB ABB Ability™ SCADAvantage Affected: 5.1 , < unspecified (custom)
Affected: unspecified , ≤ 5.6.5 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:03:45.851Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Central Licensing System",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "5*",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "ABB Ability System 800xA",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Compact HMI",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            }
          ]
        },
        {
          "product": "Control Builder Safe",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.0"
            },
            {
              "status": "affected",
              "version": "1.1"
            },
            {
              "status": "affected",
              "version": "2.0"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Operations",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.2",
              "status": "affected",
              "version": "3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Engineering ",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.2",
              "status": "affected",
              "version": "1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Composer Harmony",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Composer Melody ",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.3"
            },
            {
              "lessThanOrEqual": "6.3",
              "status": "affected",
              "version": "6",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Harmony OPC Server Standalone",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "7.0"
            }
          ]
        },
        {
          "product": "Advant OCS Control Builder A",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.3"
            },
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "Composer CTK",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "6.2"
            }
          ]
        },
        {
          "product": "AdvaBuild",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "3.7 SP1"
            },
            {
              "status": "affected",
              "version": "3.7 SP2"
            }
          ]
        },
        {
          "product": "OPC Server for Mod 300 (non-800xA)",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "OPC Data Link",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "2.1"
            },
            {
              "status": "affected",
              "version": "2.2"
            }
          ]
        },
        {
          "product": "Knowledge Manager",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "8.0"
            },
            {
              "status": "affected",
              "version": "9.0"
            },
            {
              "status": "affected",
              "version": "9.1"
            }
          ]
        },
        {
          "product": "Manufacturing Operations Management",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1812"
            },
            {
              "status": "affected",
              "version": "1909"
            }
          ]
        },
        {
          "product": "Advant  OCS AC 100 OPS Server",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "ABB  Ability\u2122 SCADAvantage",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "unspecified",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "5.6.5",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "For the Central Licensing Server component used in ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-28T00:00:00",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ABB Central Licensing System - Elevation of Privilege Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-8476",
    "datePublished": "2020-04-29T00:00:00",
    "dateReserved": "2020-01-30T00:00:00",
    "dateUpdated": "2024-08-04T10:03:45.851Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-8475 (GCVE-0-2020-8475)

Vulnerability from cvelistv5 – Published: 2020-04-29 00:00 – Updated: 2024-08-04 10:03
VLAI?
Title
ABB Central Licensing System - Denial of Service Vulnerability
Summary
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to block license handling by sending specially crafted messages to the CLS web service.
CWE
  • CWE-20 - Improper Input Validation
Assigner
ABB
Impacted products
Vendor Product Version
ABB Central Licensing System Affected: 5.1 , < 5* (custom)
Create a notification for this product.
    ABB ABB Ability System 800xA Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Compact HMI Affected: 5.1
Affected: 6.0
Create a notification for this product.
    ABB Control Builder Safe Affected: 1.0
Affected: 1.1
Affected: 2.0
Create a notification for this product.
    ABB Symphony Plus S+ Operations Affected: 3 , ≤ 3.2 (custom)
Create a notification for this product.
    ABB Symphony Plus S+ Engineering Affected: 1.1 , ≤ 2.2 (custom)
Create a notification for this product.
    ABB Composer Harmony Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Composer Melody Affected: 5.3
Affected: 6 , ≤ 6.3 (custom)
Create a notification for this product.
    ABB Harmony OPC Server Standalone Affected: 6.0
Affected: 6.1
Affected: 7.0
Create a notification for this product.
    ABB Advant OCS Control Builder A Affected: 1.3
Affected: 1.4
Create a notification for this product.
    ABB Composer CTK Affected: 6.1
Affected: 6.2
Create a notification for this product.
    ABB AdvaBuild Affected: 3.7 SP1
Affected: 3.7 SP2
Create a notification for this product.
    ABB OPC Server for Mod 300 (non-800xA) Affected: 1.4
Create a notification for this product.
    ABB OPC Data Link Affected: 2.1
Affected: 2.2
Create a notification for this product.
    ABB Knowledge Manager Affected: 8.0
Affected: 9.0
Affected: 9.1
Create a notification for this product.
    ABB Manufacturing Operations Management Affected: 1812
Affected: 1909
Create a notification for this product.
    ABB Advant OCS AC 100 OPS Server Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB ABB Ability™ SCADAvantage Affected: 5.1 , < unspecified (custom)
Affected: unspecified , ≤ 5.6.5 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:03:44.814Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Central Licensing System",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "5*",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "ABB Ability System 800xA",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Compact HMI",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            }
          ]
        },
        {
          "product": "Control Builder Safe",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.0"
            },
            {
              "status": "affected",
              "version": "1.1"
            },
            {
              "status": "affected",
              "version": "2.0"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Operations",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.2",
              "status": "affected",
              "version": "3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Engineering ",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.2",
              "status": "affected",
              "version": "1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Composer Harmony",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Composer Melody ",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.3"
            },
            {
              "lessThanOrEqual": "6.3",
              "status": "affected",
              "version": "6",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Harmony OPC Server Standalone",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "7.0"
            }
          ]
        },
        {
          "product": "Advant OCS Control Builder A",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.3"
            },
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "Composer CTK",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "6.2"
            }
          ]
        },
        {
          "product": "AdvaBuild",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "3.7 SP1"
            },
            {
              "status": "affected",
              "version": "3.7 SP2"
            }
          ]
        },
        {
          "product": "OPC Server for Mod 300 (non-800xA)",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "OPC Data Link",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "2.1"
            },
            {
              "status": "affected",
              "version": "2.2"
            }
          ]
        },
        {
          "product": "Knowledge Manager",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "8.0"
            },
            {
              "status": "affected",
              "version": "9.0"
            },
            {
              "status": "affected",
              "version": "9.1"
            }
          ]
        },
        {
          "product": "Manufacturing Operations Management",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1812"
            },
            {
              "status": "affected",
              "version": "1909"
            }
          ]
        },
        {
          "product": "Advant  OCS AC 100 OPS Server",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "ABB  Ability\u2122 SCADAvantage",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "unspecified",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "5.6.5",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "For the Central Licensing Server component used in ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to block license handling by sending specially crafted messages to the CLS web service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-28T00:00:00",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ABB Central Licensing System - Denial of Service Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-8475",
    "datePublished": "2020-04-29T00:00:00",
    "dateReserved": "2020-01-30T00:00:00",
    "dateUpdated": "2024-08-04T10:03:44.814Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-8479 (GCVE-0-2020-8479)

Vulnerability from cvelistv5 – Published: 2020-04-29 00:00 – Updated: 2024-08-04 10:03
VLAI?
Title
ABB Central Licensing System - XML External Entity Injection
Summary
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5. an XML External Entity Injection vulnerability exists that allows an attacker to read or call arbitrary files from the license server and/or from the network and also block the license handling.
CWE
  • CWE-91 - XML Injection (aka Blind XPath Injection)
Assigner
ABB
Impacted products
Vendor Product Version
ABB Central Licensing System Affected: 5.1 , < 5* (custom)
Create a notification for this product.
    ABB ABB Ability System 800xA Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Compact HMI Affected: 5.1
Affected: 6.0
Create a notification for this product.
    ABB Control Builder Safe Affected: 1.0
Affected: 1.1
Affected: 2.0
Create a notification for this product.
    ABB Symphony Plus S+ Operations Affected: 3 , ≤ 3.2 (custom)
Create a notification for this product.
    ABB Symphony Plus S+ Engineering Affected: 1.1 , ≤ 2.2 (custom)
Create a notification for this product.
    ABB Composer Harmony Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB Composer Melody Affected: 5.3
Affected: 6 , ≤ 6.3 (custom)
Create a notification for this product.
    ABB Harmony OPC Server Standalone Affected: 6.0
Affected: 6.1
Affected: 7.0
Create a notification for this product.
    ABB Advant OCS Control Builder A Affected: 1.3
Affected: 1.4
Create a notification for this product.
    ABB Composer CTK Affected: 6.1
Affected: 6.2
Create a notification for this product.
    ABB AdvaBuild Affected: 3.7 SP1
Affected: 3.7 SP2
Create a notification for this product.
    ABB OPC Server for Mod 300 (non-800xA) Affected: 1.4
Create a notification for this product.
    ABB OPC Data Link Affected: 2.1
Affected: 2.2
Create a notification for this product.
    ABB Knowledge Manager Affected: 8.0
Affected: 9.0
Affected: 9.1
Create a notification for this product.
    ABB Manufacturing Operations Management Affected: 1812
Affected: 1909
Create a notification for this product.
    ABB Advant OCS AC 100 OPS Server Affected: 5.1
Affected: 6.0
Affected: 6.1
Create a notification for this product.
    ABB ABB Ability™ SCADAvantage Affected: 5.1 , < unspecified (custom)
Affected: unspecified , ≤ 5.6.5 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:03:44.804Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Central Licensing System",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "5*",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "ABB Ability System 800xA",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Compact HMI",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            }
          ]
        },
        {
          "product": "Control Builder Safe",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.0"
            },
            {
              "status": "affected",
              "version": "1.1"
            },
            {
              "status": "affected",
              "version": "2.0"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Operations",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.2",
              "status": "affected",
              "version": "3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Engineering ",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.2",
              "status": "affected",
              "version": "1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Composer Harmony",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Composer Melody ",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.3"
            },
            {
              "lessThanOrEqual": "6.3",
              "status": "affected",
              "version": "6",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Harmony OPC Server Standalone",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "7.0"
            }
          ]
        },
        {
          "product": "Advant OCS Control Builder A",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.3"
            },
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "Composer CTK",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "6.2"
            }
          ]
        },
        {
          "product": "AdvaBuild",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "3.7 SP1"
            },
            {
              "status": "affected",
              "version": "3.7 SP2"
            }
          ]
        },
        {
          "product": "OPC Server for Mod 300 (non-800xA)",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "OPC Data Link",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "2.1"
            },
            {
              "status": "affected",
              "version": "2.2"
            }
          ]
        },
        {
          "product": "Knowledge Manager",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "8.0"
            },
            {
              "status": "affected",
              "version": "9.0"
            },
            {
              "status": "affected",
              "version": "9.1"
            }
          ]
        },
        {
          "product": "Manufacturing Operations Management",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1812"
            },
            {
              "status": "affected",
              "version": "1909"
            }
          ]
        },
        {
          "product": "Advant  OCS AC 100 OPS Server",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "ABB  Ability\u2122 SCADAvantage",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "unspecified",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "5.6.5",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "For the Central Licensing Server component used in ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5. an XML External Entity Injection vulnerability exists that allows an attacker to read or call arbitrary files from the license server and/or from the network and also block the license handling."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-91",
              "description": "CWE-91 XML Injection (aka Blind XPath Injection)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-28T00:00:00",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ABB Central Licensing System - XML External Entity Injection",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-8479",
    "datePublished": "2020-04-29T00:00:00",
    "dateReserved": "2020-01-30T00:00:00",
    "dateUpdated": "2024-08-04T10:03:44.804Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}