cve-2020-8476
Vulnerability from cvelistv5
Published
2020-04-29 00:00
Modified
2024-08-04 10:03
Summary
ABB Central Licensing System - Elevation of Privilege Vulnerability
Impacted products
Vendor Product Version
ABB ABB Ability System 800xA Version: 5.1
Version: 6.0
Version: 6.1
ABB Compact HMI Version: 5.1
Version: 6.0
ABB Control Builder Safe Version: 1.0
Version: 1.1
Version: 2.0
ABB Symphony Plus S+ Operations Version: 3   <
ABB Symphony Plus S+ Engineering Version: 1.1   <
ABB Composer Harmony Version: 5.1
Version: 6.0
Version: 6.1
ABB Composer Melody Version: 5.3
Version: 6   <
ABB Harmony OPC Server Standalone Version: 6.0
Version: 6.1
Version: 7.0
ABB Advant OCS Control Builder A Version: 1.3
Version: 1.4
ABB Composer CTK Version: 6.1
Version: 6.2
ABB AdvaBuild Version: 3.7 SP1
Version: 3.7 SP2
ABB OPC Server for Mod 300 (non-800xA) Version: 1.4
ABB OPC Data Link Version: 2.1
Version: 2.2
ABB Knowledge Manager Version: 8.0
Version: 9.0
Version: 9.1
ABB Manufacturing Operations Management Version: 1812
Version: 1909
ABB Advant OCS AC 100 OPS Server Version: 5.1
Version: 6.0
Version: 6.1
ABB ABB Ability™ SCADAvantage Version: 5.1   < unspecified
Version: unspecified   <
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:03:45.851Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Central Licensing System",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "5*",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "ABB Ability System 800xA",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Compact HMI",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            }
          ]
        },
        {
          "product": "Control Builder Safe",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.0"
            },
            {
              "status": "affected",
              "version": "1.1"
            },
            {
              "status": "affected",
              "version": "2.0"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Operations",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.2",
              "status": "affected",
              "version": "3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Symphony Plus S+ Engineering ",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.2",
              "status": "affected",
              "version": "1.1",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Composer Harmony",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "Composer Melody ",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.3"
            },
            {
              "lessThanOrEqual": "6.3",
              "status": "affected",
              "version": "6",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Harmony OPC Server Standalone",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "7.0"
            }
          ]
        },
        {
          "product": "Advant OCS Control Builder A",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.3"
            },
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "Composer CTK",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "6.1"
            },
            {
              "status": "affected",
              "version": "6.2"
            }
          ]
        },
        {
          "product": "AdvaBuild",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "3.7 SP1"
            },
            {
              "status": "affected",
              "version": "3.7 SP2"
            }
          ]
        },
        {
          "product": "OPC Server for Mod 300 (non-800xA)",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1.4"
            }
          ]
        },
        {
          "product": "OPC Data Link",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "2.1"
            },
            {
              "status": "affected",
              "version": "2.2"
            }
          ]
        },
        {
          "product": "Knowledge Manager",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "8.0"
            },
            {
              "status": "affected",
              "version": "9.0"
            },
            {
              "status": "affected",
              "version": "9.1"
            }
          ]
        },
        {
          "product": "Manufacturing Operations Management",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "1812"
            },
            {
              "status": "affected",
              "version": "1909"
            }
          ]
        },
        {
          "product": "Advant  OCS AC 100 OPS Server",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "6.0"
            },
            {
              "status": "affected",
              "version": "6.1"
            }
          ]
        },
        {
          "product": "ABB  Ability\u2122 SCADAvantage",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "unspecified",
              "status": "affected",
              "version": "5.1",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "5.6.5",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "For the Central Licensing Server component used in ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-28T00:00:00",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "ABB Central Licensing System - Elevation of Privilege Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-8476",
    "datePublished": "2020-04-29T00:00:00",
    "dateReserved": "2020-01-30T00:00:00",
    "dateUpdated": "2024-08-04T10:03:45.851Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-8476\",\"sourceIdentifier\":\"cybersecurity@ch.abb.com\",\"published\":\"2020-04-29T02:15:11.687\",\"lastModified\":\"2022-10-28T02:15:16.447\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"For the Central Licensing Server component used in ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service.\"},{\"lang\":\"es\",\"value\":\"Para el componente Central Licensing Server utilizado en los productos ABB Ability\u2122 System 800xA y las extensiones del sistema relacionadas, versiones 5.1, 6.0 y 6.1, Compact HMI versiones 5.1 y 6.0, Control Builder Safe 1.0, 1.1 y 2.0, Symphony Plus -S+ Operations 3.0 a 3. 2 Symphony Plus -S+ Engineering 1.1 a 2.2, Composer Harmony 5.1, 6.0 y 6.1, Melody Composer 5.3, 6.1/6.2 y SPE para Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 y 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1. 3 y 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 y 6.1, Composer CTK 6.1 y 6.2, AdvaBuild 3.7 SP1 y SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 y 2.2, Knowledge Manager 8.0, 9.0 y 9. 1, Manufacturing Operations Management 1812 y 1909, ABB AbilityTM SCADAvantage versiones 5.1 a 5.6.5, existe una debilidad en la validaci\u00f3n de la entrada que permite a un atacante alterar las licencias asignadas a los nodos del sistema enviando mensajes especialmente dise\u00f1ados al servicio web CLS\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"cybersecurity@ch.abb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:P/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]},{\"source\":\"cybersecurity@ch.abb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:800xa_system:5.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"342DDBC9-9FD6-4B34-AE9D-570173A28ECE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:800xa_system:5.1:feature_pack_4:*:*:*:*:*:*\",\"matchCriteriaId\":\"1A050979-A994-49BD-9B8A-2CE8D1A21E1D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:800xa_system:5.1:feature_pack_4_revision_d:*:*:*:*:*:*\",\"matchCriteriaId\":\"12AEB479-DF30-4E2E-A384-0420176B7DDD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:800xa_system:5.1:revision_a:*:*:*:*:*:*\",\"matchCriteriaId\":\"5BF8C28D-4058-47E2-B540-7CA70702D659\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:800xa_system:5.1:revision_b:*:*:*:*:*:*\",\"matchCriteriaId\":\"81955875-0A94-45A7-B006-976555BAAA4C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:800xa_system:5.1:revision_c:*:*:*:*:*:*\",\"matchCriteriaId\":\"E2F9226C-1D0B-42FC-AF3D-7C887B1B4CB9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:800xa_system:5.1:revision_d:*:*:*:*:*:*\",\"matchCriteriaId\":\"77831051-E99E-48D3-8064-8F46FDB1D8B2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:800xa_system:5.1:revision_e:*:*:*:*:*:*\",\"matchCriteriaId\":\"1599944B-B135-4749-99D3-67A0A57D391B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:800xa_system:5.1:revision_e_feature_pack_4:*:*:*:*:*:*\",\"matchCriteriaId\":\"0BD664F9-E4EF-4470-9D28-724769D725CB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:800xa_system:6.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CA233139-3C36-4FAC-8C00-07C2993CE76D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:800xa_system:6.0.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C9BF94DB-5305-4377-839B-F881EE66E831\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:800xa_system:6.0.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8BD4D1B8-27CE-46AC-ABD0-1D8450CB07EB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:800xa_system:6.0.3.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"45C9941D-F127-40A1-BFA4-C8D243465C4B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:800xa_system:6.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ADABF9B1-0CD4-45D5-8A27-62ADB848718A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:compact_hmi:5.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"DBAA8BAB-F7D7-41EF-9011-211BB060915E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:compact_hmi:5.1:feature_pack_4_revision_d:*:*:*:*:*:*\",\"matchCriteriaId\":\"8F8C8D8B-3DD2-4269-A151-6575D81E0853\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:compact_hmi:5.1:revision_b:*:*:*:*:*:*\",\"matchCriteriaId\":\"80C9557B-25E2-49E7-9CC0-646B9F1613B5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:compact_hmi:5.1:revision_d:*:*:*:*:*:*\",\"matchCriteriaId\":\"51D26A7F-A97A-4A5E-B5CC-7DEAD57F8205\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:compact_hmi:6.0.1-1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"98DF36B0-B85E-474E-889A-BD7B5E6918FE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:compact_hmi:6.0.3-2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"42CCE362-2A91-4199-8D52-F24EFFA7C33C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:control_builder_safe:1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8BDC5CDB-084E-43D8-8B3A-44081046BEC0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:control_builder_safe:1.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"27E57B1E-19DE-4FA4-8E44-39E9DCE1AAC5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:control_builder_safe:2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CB9438BF-271C-4BAC-B10E-1142E3CE8A02\"}]}]}],\"references\":[{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"cybersecurity@ch.abb.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"cybersecurity@ch.abb.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"cybersecurity@ch.abb.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.