Search criteria
24 vulnerabilities found for alpha5_smart_loader_firmware by fujielectric
FKIE_CVE-2022-21228
Vulnerability from fkie_nvd - Published: 2022-04-12 17:15 - Updated: 2024-11-21 06:44
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03 | Mitigation, Patch, Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03 | Mitigation, Patch, Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| fujielectric | alpha5_smart_loader_firmware | * | |
| fujielectric | alpha5_smart_loader | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:fujielectric:alpha5_smart_loader_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B8DD9ED6-D516-42EC-8113-92CF0F24E833",
"versionEndExcluding": "4.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:fujielectric:alpha5_smart_loader:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5319594A-AD04-4A71-875A-16EE68D28661",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code."
},
{
"lang": "es",
"value": "El producto afectado es vulnerable a un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria, que puede permitir a un atacante ejecutar c\u00f3digo arbitrario"
}
],
"id": "CVE-2022-21228",
"lastModified": "2024-11-21T06:44:09.170",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-12T17:15:09.227",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Mitigation",
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2022-21168
Vulnerability from fkie_nvd - Published: 2022-04-12 17:15 - Updated: 2024-11-21 06:44
Severity ?
3.3 (Low) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
Summary
The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03 | Patch, Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03 | Patch, Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| fujielectric | alpha5_smart_loader_firmware | * | |
| fujielectric | alpha5_smart_loader | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:fujielectric:alpha5_smart_loader_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B8DD9ED6-D516-42EC-8113-92CF0F24E833",
"versionEndExcluding": "4.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:fujielectric:alpha5_smart_loader:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5319594A-AD04-4A71-875A-16EE68D28661",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure."
},
{
"lang": "es",
"value": "El producto afectado es vulnerable debido a una inicializaci\u00f3n de puntero no v\u00e1lida, que puede conllevar a una divulgaci\u00f3n de informaci\u00f3n"
}
],
"id": "CVE-2022-21168",
"lastModified": "2024-11-21T06:44:01.630",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 1.4,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-12T17:15:09.053",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-824"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
]
}
FKIE_CVE-2022-21202
Vulnerability from fkie_nvd - Published: 2022-04-12 17:15 - Updated: 2024-11-21 06:44
Severity ?
3.3 (Low) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
Summary
The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03 | Patch, Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03 | Patch, Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| fujielectric | alpha5_smart_loader_firmware | * | |
| fujielectric | alpha5_smart_loader | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:fujielectric:alpha5_smart_loader_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B8DD9ED6-D516-42EC-8113-92CF0F24E833",
"versionEndExcluding": "4.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:fujielectric:alpha5_smart_loader:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5319594A-AD04-4A71-875A-16EE68D28661",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information."
},
{
"lang": "es",
"value": "El producto afectado es vulnerable a una lectura fuera de l\u00edmites, que puede resultar en una divulgaci\u00f3n de informaci\u00f3n confidencial"
}
],
"id": "CVE-2022-21202",
"lastModified": "2024-11-21T06:44:05.777",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 1.4,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-12T17:15:09.110",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-125"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
]
}
FKIE_CVE-2022-24383
Vulnerability from fkie_nvd - Published: 2022-04-12 17:15 - Updated: 2024-11-21 06:50
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
The affected product is vulnerable to an out-of-bounds read, which may result in code execution
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03 | Patch, Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03 | Patch, Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| fujielectric | alpha5_smart_loader_firmware | * | |
| fujielectric | alpha5_smart_loader | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:fujielectric:alpha5_smart_loader_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B8DD9ED6-D516-42EC-8113-92CF0F24E833",
"versionEndExcluding": "4.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:fujielectric:alpha5_smart_loader:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5319594A-AD04-4A71-875A-16EE68D28661",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to an out-of-bounds read, which may result in code execution"
},
{
"lang": "es",
"value": "El producto afectado es vulnerable a una lectura fuera de l\u00edmites, que puede resultar en la ejecuci\u00f3n de c\u00f3digo"
}
],
"id": "CVE-2022-24383",
"lastModified": "2024-11-21T06:50:18.380",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-12T17:15:09.443",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-125"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
]
}
FKIE_CVE-2022-21214
Vulnerability from fkie_nvd - Published: 2022-04-12 17:15 - Updated: 2024-11-21 06:44
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03 | Mitigation, Patch, Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03 | Mitigation, Patch, Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| fujielectric | alpha5_smart_loader_firmware | * | |
| fujielectric | alpha5_smart_loader | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:fujielectric:alpha5_smart_loader_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B8DD9ED6-D516-42EC-8113-92CF0F24E833",
"versionEndExcluding": "4.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:fujielectric:alpha5_smart_loader:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5319594A-AD04-4A71-875A-16EE68D28661",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution."
},
{
"lang": "es",
"value": "El producto afectado es vulnerable a un desbordamiento de b\u00fafer en la regi\u00f3n heap de la memoria, que puede conllevar a una ejecuci\u00f3n de c\u00f3digo"
}
],
"id": "CVE-2022-21214",
"lastModified": "2024-11-21T06:44:07.813",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-12T17:15:09.170",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Mitigation",
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-122"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
]
}
FKIE_CVE-2019-13520
Vulnerability from fkie_nvd - Published: 2019-08-20 20:15 - Updated: 2024-11-21 04:25
Severity ?
Summary
Multiple buffer overflow issues have been identified in Alpha5 Smart Loader: All versions prior to 4.2. An attacker could use specially crafted project files to overflow the buffer and execute code under the privileges of the application.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.us-cert.gov/ics/advisories/icsa-19-227-02 | Mitigation, Third Party Advisory, US Government Resource | |
| ics-cert@hq.dhs.gov | https://www.zerodayinitiative.com/advisories/ZDI-19-798/ | Third Party Advisory, VDB Entry | |
| ics-cert@hq.dhs.gov | https://www.zerodayinitiative.com/advisories/ZDI-19-820/ | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-227-02 | Mitigation, Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-19-798/ | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-19-820/ | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| fujielectric | alpha5_smart_loader_firmware | * | |
| fujielectric | alpha5_smart_loader | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:fujielectric:alpha5_smart_loader_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F80A50DD-1EFF-4F5D-81C1-7DD5651E9F35",
"versionEndExcluding": "4.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:fujielectric:alpha5_smart_loader:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5319594A-AD04-4A71-875A-16EE68D28661",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Multiple buffer overflow issues have been identified in Alpha5 Smart Loader: All versions prior to 4.2. An attacker could use specially crafted project files to overflow the buffer and execute code under the privileges of the application."
},
{
"lang": "es",
"value": "Se han identificado varios problemas de desbordamiento de b\u00fafer en Alpha5 Smart Loader: Todas las versiones anteriores a 4.2. Un atacante podr\u00eda usar archivos de proyecto especialmente dise\u00f1ados para desbordar el b\u00fafer y ejecutar c\u00f3digo bajo los privilegios de la aplicaci\u00f3n."
}
],
"id": "CVE-2019-13520",
"lastModified": "2024-11-21T04:25:03.823",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-08-20T20:15:11.933",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-14788
Vulnerability from fkie_nvd - Published: 2018-10-01 13:29 - Updated: 2024-11-21 03:49
Severity ?
Summary
Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain file types.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/105411 | Third Party Advisory, VDB Entry | |
| ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02 | Mitigation, Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/105411 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02 | Mitigation, Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| fujielectric | alpha5_smart_loader_firmware | * | |
| fujielectric | alpha5_smart_loader | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:fujielectric:alpha5_smart_loader_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4494AD60-80C3-4B40-87A8-4D119AB77C69",
"versionEndIncluding": "3.7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:fujielectric:alpha5_smart_loader:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5319594A-AD04-4A71-875A-16EE68D28661",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain file types."
},
{
"lang": "es",
"value": "Fuji Electric Alpha5 Smart Loader en versiones 3.7 y anteriores. Ocurre una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n por desbordamiento de b\u00fafer al analizar ciertos tipos de archivo."
}
],
"id": "CVE-2018-14788",
"lastModified": "2024-11-21T03:49:47.707",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-10-01T13:29:00.317",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/105411"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/105411"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-14794
Vulnerability from fkie_nvd - Published: 2018-10-01 13:29 - Updated: 2024-11-21 03:49
Severity ?
Summary
Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. The device does not perform a check on the length/size of a project file before copying the entire contents of the file to a heap-based buffer.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/105411 | Third Party Advisory, VDB Entry | |
| ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02 | Mitigation, Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/105411 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02 | Mitigation, Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| fujielectric | alpha5_smart_loader_firmware | * | |
| fujielectric | alpha5_smart_loader | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:fujielectric:alpha5_smart_loader_firmware:*:*:*:*:*:*:*:undefined",
"matchCriteriaId": "82127E64-0A12-4066-87DC-5719869B9ADC",
"versionEndIncluding": "3.7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:fujielectric:alpha5_smart_loader:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5319594A-AD04-4A71-875A-16EE68D28661",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. The device does not perform a check on the length/size of a project file before copying the entire contents of the file to a heap-based buffer."
},
{
"lang": "es",
"value": "Fuji Electric Alpha5 Smart Loader en versiones 3.7 y anteriores. El dispositivo no realiza una comprobaci\u00f3n de la longitud/tama\u00f1o de un archivo de proyecto antes de copiar todo el contenido del archivo a un b\u00fafer basado en memoria din\u00e1mica (heap)."
}
],
"id": "CVE-2018-14794",
"lastModified": "2024-11-21T03:49:48.513",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-10-01T13:29:00.550",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/105411"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/105411"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-122"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2022-21202 (GCVE-0-2022-21202)
Vulnerability from cvelistv5 – Published: 2022-04-12 16:11 – Updated: 2025-04-16 16:30
VLAI?
Title
ICSA-22-090-03 Fuji Electric Alpha5
Summary
The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | Alpha5 |
Affected:
All , < 4.3
(custom)
|
Credits
Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:31:58.993Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-21202",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:54:43.032875Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:30:47.541Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Alpha5",
"vendor": "Fuji Electric",
"versions": [
{
"lessThan": "4.3",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"datePublic": "2022-03-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T16:11:54.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
},
"title": "ICSA-22-090-03 Fuji Electric Alpha5",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
"ID": "CVE-2022-21202",
"STATE": "PUBLIC",
"TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Alpha5",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "4.3"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125 Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-21202",
"datePublished": "2022-04-12T16:11:54.258Z",
"dateReserved": "2022-02-08T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:30:47.541Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24383 (GCVE-0-2022-24383)
Vulnerability from cvelistv5 – Published: 2022-04-12 16:11 – Updated: 2025-04-16 17:55
VLAI?
Title
ICSA-22-090-03 Fuji Electric Alpha5
Summary
The affected product is vulnerable to an out-of-bounds read, which may result in code execution
Severity ?
7.8 (High)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | Alpha5 |
Affected:
All , < 4.3
(custom)
|
Credits
Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:07:02.533Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-24383",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T17:29:48.595288Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T17:55:50.569Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Alpha5",
"vendor": "Fuji Electric",
"versions": [
{
"lessThan": "4.3",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"datePublic": "2022-03-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to an out-of-bounds read, which may result in code execution"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T16:11:53.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
},
"title": "ICSA-22-090-03 Fuji Electric Alpha5",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
"ID": "CVE-2022-24383",
"STATE": "PUBLIC",
"TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Alpha5",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "4.3"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable to an out-of-bounds read, which may result in code execution"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125 Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-24383",
"datePublished": "2022-04-12T16:11:53.500Z",
"dateReserved": "2022-02-08T00:00:00.000Z",
"dateUpdated": "2025-04-16T17:55:50.569Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-21228 (GCVE-0-2022-21228)
Vulnerability from cvelistv5 – Published: 2022-04-12 16:11 – Updated: 2025-04-16 17:55
VLAI?
Title
ICSA-22-090-03 Fuji Electric Alpha5
Summary
The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.
Severity ?
7.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | Alpha5 |
Affected:
All , < 4.3
(custom)
|
Credits
Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:31:59.332Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-21228",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T17:29:51.306782Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T17:55:58.282Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Alpha5",
"vendor": "Fuji Electric",
"versions": [
{
"lessThan": "4.3",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"datePublic": "2022-03-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T16:11:52.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
},
"title": "ICSA-22-090-03 Fuji Electric Alpha5",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
"ID": "CVE-2022-21228",
"STATE": "PUBLIC",
"TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Alpha5",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "4.3"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121 Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-21228",
"datePublished": "2022-04-12T16:11:52.740Z",
"dateReserved": "2022-02-08T00:00:00.000Z",
"dateUpdated": "2025-04-16T17:55:58.282Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-21214 (GCVE-0-2022-21214)
Vulnerability from cvelistv5 – Published: 2022-04-12 16:11 – Updated: 2025-04-16 17:56
VLAI?
Title
ICSA-22-090-03 Fuji Electric Alpha5
Summary
The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution.
Severity ?
7.8 (High)
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | Alpha5 |
Affected:
All , < 4.3
(custom)
|
Credits
Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:31:59.232Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-21214",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T17:29:53.975635Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T17:56:06.297Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Alpha5",
"vendor": "Fuji Electric",
"versions": [
{
"lessThan": "4.3",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"datePublic": "2022-03-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T16:11:51.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
},
"title": "ICSA-22-090-03 Fuji Electric Alpha5",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
"ID": "CVE-2022-21214",
"STATE": "PUBLIC",
"TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Alpha5",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "4.3"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122 Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-21214",
"datePublished": "2022-04-12T16:11:51.679Z",
"dateReserved": "2022-02-08T00:00:00.000Z",
"dateUpdated": "2025-04-16T17:56:06.297Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-21168 (GCVE-0-2022-21168)
Vulnerability from cvelistv5 – Published: 2022-04-12 16:11 – Updated: 2025-04-16 16:30
VLAI?
Title
ICSA-22-090-03 Fuji Electric Alpha5
Summary
The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure.
Severity ?
CWE
- CWE-824 - Access of Uninitialized Pointer
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | Alpha5 |
Affected:
All , < 4.3
(custom)
|
Credits
Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:31:59.723Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-21168",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:54:46.252298Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:30:55.958Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Alpha5",
"vendor": "Fuji Electric",
"versions": [
{
"lessThan": "4.3",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"datePublic": "2022-03-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-824",
"description": "CWE-824 Access of Uninitialized Pointer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T16:11:50.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
},
"title": "ICSA-22-090-03 Fuji Electric Alpha5",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
"ID": "CVE-2022-21168",
"STATE": "PUBLIC",
"TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Alpha5",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "4.3"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-824 Access of Uninitialized Pointer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-21168",
"datePublished": "2022-04-12T16:11:50.947Z",
"dateReserved": "2022-02-08T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:30:55.958Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-13520 (GCVE-0-2019-13520)
Vulnerability from cvelistv5 – Published: 2019-08-20 19:38 – Updated: 2024-08-04 23:57
VLAI?
Summary
Multiple buffer overflow issues have been identified in Alpha5 Smart Loader: All versions prior to 4.2. An attacker could use specially crafted project files to overflow the buffer and execute code under the privileges of the application.
Severity ?
No CVSS data available.
CWE
- CWE-121 - Stack-Based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Alpha5 Smart Loader |
Affected:
All versions prior to 4.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:57:38.997Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Alpha5 Smart Loader",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions prior to 4.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Multiple buffer overflow issues have been identified in Alpha5 Smart Loader: All versions prior to 4.2. An attacker could use specially crafted project files to overflow the buffer and execute code under the privileges of the application."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-Based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-11T20:06:08",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2019-13520",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Alpha5 Smart Loader",
"version": {
"version_data": [
{
"version_value": "All versions prior to 4.2"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple buffer overflow issues have been identified in Alpha5 Smart Loader: All versions prior to 4.2. An attacker could use specially crafted project files to overflow the buffer and execute code under the privileges of the application."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121 Stack-Based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2019-13520",
"datePublished": "2019-08-20T19:38:39",
"dateReserved": "2019-07-11T00:00:00",
"dateUpdated": "2024-08-04T23:57:38.997Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-14788 (GCVE-0-2018-14788)
Vulnerability from cvelistv5 – Published: 2018-10-01 13:00 – Updated: 2024-09-17 01:35
VLAI?
Summary
Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain file types.
Severity ?
No CVSS data available.
CWE
- CWE-120 - BUFFER COPY WITHOUT CHECKING SIZE OF INPUT ('CLASSIC BUFFER OVERFLOW') CWE-120
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | Alpha5 Smart Loader |
Affected:
3.7 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T09:38:13.975Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105411",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105411"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Alpha5 Smart Loader",
"vendor": "Fuji Electric",
"versions": [
{
"status": "affected",
"version": "3.7 and prior"
}
]
}
],
"datePublic": "2018-09-27T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain file types."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (\u0027CLASSIC BUFFER OVERFLOW\u0027) CWE-120",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-02T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "105411",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105411"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-09-27T00:00:00",
"ID": "CVE-2018-14788",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Alpha5 Smart Loader",
"version": {
"version_data": [
{
"version_value": "3.7 and prior"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain file types."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (\u0027CLASSIC BUFFER OVERFLOW\u0027) CWE-120"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105411",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105411"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-14788",
"datePublished": "2018-10-01T13:00:00Z",
"dateReserved": "2018-08-01T00:00:00",
"dateUpdated": "2024-09-17T01:35:37.005Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-14794 (GCVE-0-2018-14794)
Vulnerability from cvelistv5 – Published: 2018-10-01 13:00 – Updated: 2024-09-16 17:14
VLAI?
Summary
Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. The device does not perform a check on the length/size of a project file before copying the entire contents of the file to a heap-based buffer.
Severity ?
No CVSS data available.
CWE
- CWE-122 - HEAP-BASED BUFFER OVERFLOW CWE-122
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | Alpha5 Smart Loader |
Affected:
3.7 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T09:38:13.984Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105411",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105411"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Alpha5 Smart Loader",
"vendor": "Fuji Electric",
"versions": [
{
"status": "affected",
"version": "3.7 and prior"
}
]
}
],
"datePublic": "2018-09-27T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. The device does not perform a check on the length/size of a project file before copying the entire contents of the file to a heap-based buffer."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-02T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "105411",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105411"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-09-27T00:00:00",
"ID": "CVE-2018-14794",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Alpha5 Smart Loader",
"version": {
"version_data": [
{
"version_value": "3.7 and prior"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. The device does not perform a check on the length/size of a project file before copying the entire contents of the file to a heap-based buffer."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105411",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105411"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-14794",
"datePublished": "2018-10-01T13:00:00Z",
"dateReserved": "2018-08-01T00:00:00",
"dateUpdated": "2024-09-16T17:14:37.175Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-21202 (GCVE-0-2022-21202)
Vulnerability from nvd – Published: 2022-04-12 16:11 – Updated: 2025-04-16 16:30
VLAI?
Title
ICSA-22-090-03 Fuji Electric Alpha5
Summary
The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | Alpha5 |
Affected:
All , < 4.3
(custom)
|
Credits
Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:31:58.993Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-21202",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:54:43.032875Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:30:47.541Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Alpha5",
"vendor": "Fuji Electric",
"versions": [
{
"lessThan": "4.3",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"datePublic": "2022-03-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T16:11:54.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
},
"title": "ICSA-22-090-03 Fuji Electric Alpha5",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
"ID": "CVE-2022-21202",
"STATE": "PUBLIC",
"TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Alpha5",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "4.3"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125 Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-21202",
"datePublished": "2022-04-12T16:11:54.258Z",
"dateReserved": "2022-02-08T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:30:47.541Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24383 (GCVE-0-2022-24383)
Vulnerability from nvd – Published: 2022-04-12 16:11 – Updated: 2025-04-16 17:55
VLAI?
Title
ICSA-22-090-03 Fuji Electric Alpha5
Summary
The affected product is vulnerable to an out-of-bounds read, which may result in code execution
Severity ?
7.8 (High)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | Alpha5 |
Affected:
All , < 4.3
(custom)
|
Credits
Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:07:02.533Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-24383",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T17:29:48.595288Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T17:55:50.569Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Alpha5",
"vendor": "Fuji Electric",
"versions": [
{
"lessThan": "4.3",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"datePublic": "2022-03-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to an out-of-bounds read, which may result in code execution"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T16:11:53.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
},
"title": "ICSA-22-090-03 Fuji Electric Alpha5",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
"ID": "CVE-2022-24383",
"STATE": "PUBLIC",
"TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Alpha5",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "4.3"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable to an out-of-bounds read, which may result in code execution"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125 Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-24383",
"datePublished": "2022-04-12T16:11:53.500Z",
"dateReserved": "2022-02-08T00:00:00.000Z",
"dateUpdated": "2025-04-16T17:55:50.569Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-21228 (GCVE-0-2022-21228)
Vulnerability from nvd – Published: 2022-04-12 16:11 – Updated: 2025-04-16 17:55
VLAI?
Title
ICSA-22-090-03 Fuji Electric Alpha5
Summary
The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.
Severity ?
7.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | Alpha5 |
Affected:
All , < 4.3
(custom)
|
Credits
Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:31:59.332Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-21228",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T17:29:51.306782Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T17:55:58.282Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Alpha5",
"vendor": "Fuji Electric",
"versions": [
{
"lessThan": "4.3",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"datePublic": "2022-03-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T16:11:52.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
},
"title": "ICSA-22-090-03 Fuji Electric Alpha5",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
"ID": "CVE-2022-21228",
"STATE": "PUBLIC",
"TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Alpha5",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "4.3"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121 Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-21228",
"datePublished": "2022-04-12T16:11:52.740Z",
"dateReserved": "2022-02-08T00:00:00.000Z",
"dateUpdated": "2025-04-16T17:55:58.282Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-21214 (GCVE-0-2022-21214)
Vulnerability from nvd – Published: 2022-04-12 16:11 – Updated: 2025-04-16 17:56
VLAI?
Title
ICSA-22-090-03 Fuji Electric Alpha5
Summary
The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution.
Severity ?
7.8 (High)
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | Alpha5 |
Affected:
All , < 4.3
(custom)
|
Credits
Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:31:59.232Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-21214",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T17:29:53.975635Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T17:56:06.297Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Alpha5",
"vendor": "Fuji Electric",
"versions": [
{
"lessThan": "4.3",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"datePublic": "2022-03-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T16:11:51.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
},
"title": "ICSA-22-090-03 Fuji Electric Alpha5",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
"ID": "CVE-2022-21214",
"STATE": "PUBLIC",
"TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Alpha5",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "4.3"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122 Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-21214",
"datePublished": "2022-04-12T16:11:51.679Z",
"dateReserved": "2022-02-08T00:00:00.000Z",
"dateUpdated": "2025-04-16T17:56:06.297Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-21168 (GCVE-0-2022-21168)
Vulnerability from nvd – Published: 2022-04-12 16:11 – Updated: 2025-04-16 16:30
VLAI?
Title
ICSA-22-090-03 Fuji Electric Alpha5
Summary
The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure.
Severity ?
CWE
- CWE-824 - Access of Uninitialized Pointer
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | Alpha5 |
Affected:
All , < 4.3
(custom)
|
Credits
Xina1i, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:31:59.723Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-21168",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:54:46.252298Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:30:55.958Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Alpha5",
"vendor": "Fuji Electric",
"versions": [
{
"lessThan": "4.3",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"datePublic": "2022-03-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-824",
"description": "CWE-824 Access of Uninitialized Pointer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T16:11:50.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
],
"solutions": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
},
"title": "ICSA-22-090-03 Fuji Electric Alpha5",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-03-31T17:00:00.000Z",
"ID": "CVE-2022-21168",
"STATE": "PUBLIC",
"TITLE": "ICSA-22-090-03 Fuji Electric Alpha5"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Alpha5",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "4.3"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Xina1i, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-824 Access of Uninitialized Pointer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-03"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fuji Electric recommends upgrading to Alpha5 v4.4. The files can be obtained in the Fuji Library."
}
],
"source": {
"advisory": "ICSA-22-090-03",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-21168",
"datePublished": "2022-04-12T16:11:50.947Z",
"dateReserved": "2022-02-08T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:30:55.958Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-13520 (GCVE-0-2019-13520)
Vulnerability from nvd – Published: 2019-08-20 19:38 – Updated: 2024-08-04 23:57
VLAI?
Summary
Multiple buffer overflow issues have been identified in Alpha5 Smart Loader: All versions prior to 4.2. An attacker could use specially crafted project files to overflow the buffer and execute code under the privileges of the application.
Severity ?
No CVSS data available.
CWE
- CWE-121 - Stack-Based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Alpha5 Smart Loader |
Affected:
All versions prior to 4.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:57:38.997Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Alpha5 Smart Loader",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions prior to 4.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Multiple buffer overflow issues have been identified in Alpha5 Smart Loader: All versions prior to 4.2. An attacker could use specially crafted project files to overflow the buffer and execute code under the privileges of the application."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-Based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-11T20:06:08",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2019-13520",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Alpha5 Smart Loader",
"version": {
"version_data": [
{
"version_value": "All versions prior to 4.2"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple buffer overflow issues have been identified in Alpha5 Smart Loader: All versions prior to 4.2. An attacker could use specially crafted project files to overflow the buffer and execute code under the privileges of the application."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121 Stack-Based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-02"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-798/"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-820/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2019-13520",
"datePublished": "2019-08-20T19:38:39",
"dateReserved": "2019-07-11T00:00:00",
"dateUpdated": "2024-08-04T23:57:38.997Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-14788 (GCVE-0-2018-14788)
Vulnerability from nvd – Published: 2018-10-01 13:00 – Updated: 2024-09-17 01:35
VLAI?
Summary
Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain file types.
Severity ?
No CVSS data available.
CWE
- CWE-120 - BUFFER COPY WITHOUT CHECKING SIZE OF INPUT ('CLASSIC BUFFER OVERFLOW') CWE-120
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | Alpha5 Smart Loader |
Affected:
3.7 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T09:38:13.975Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105411",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105411"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Alpha5 Smart Loader",
"vendor": "Fuji Electric",
"versions": [
{
"status": "affected",
"version": "3.7 and prior"
}
]
}
],
"datePublic": "2018-09-27T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain file types."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (\u0027CLASSIC BUFFER OVERFLOW\u0027) CWE-120",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-02T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "105411",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105411"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-09-27T00:00:00",
"ID": "CVE-2018-14788",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Alpha5 Smart Loader",
"version": {
"version_data": [
{
"version_value": "3.7 and prior"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain file types."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (\u0027CLASSIC BUFFER OVERFLOW\u0027) CWE-120"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105411",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105411"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-14788",
"datePublished": "2018-10-01T13:00:00Z",
"dateReserved": "2018-08-01T00:00:00",
"dateUpdated": "2024-09-17T01:35:37.005Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-14794 (GCVE-0-2018-14794)
Vulnerability from nvd – Published: 2018-10-01 13:00 – Updated: 2024-09-16 17:14
VLAI?
Summary
Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. The device does not perform a check on the length/size of a project file before copying the entire contents of the file to a heap-based buffer.
Severity ?
No CVSS data available.
CWE
- CWE-122 - HEAP-BASED BUFFER OVERFLOW CWE-122
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | Alpha5 Smart Loader |
Affected:
3.7 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T09:38:13.984Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105411",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105411"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Alpha5 Smart Loader",
"vendor": "Fuji Electric",
"versions": [
{
"status": "affected",
"version": "3.7 and prior"
}
]
}
],
"datePublic": "2018-09-27T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. The device does not perform a check on the length/size of a project file before copying the entire contents of the file to a heap-based buffer."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-02T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "105411",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105411"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-09-27T00:00:00",
"ID": "CVE-2018-14794",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Alpha5 Smart Loader",
"version": {
"version_data": [
{
"version_value": "3.7 and prior"
}
]
}
}
]
},
"vendor_name": "Fuji Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. The device does not perform a check on the length/size of a project file before copying the entire contents of the file to a heap-based buffer."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105411",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105411"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-14794",
"datePublished": "2018-10-01T13:00:00Z",
"dateReserved": "2018-08-01T00:00:00",
"dateUpdated": "2024-09-16T17:14:37.175Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}