Search criteria
6 vulnerabilities found for assurity_firmware by abbott
FKIE_CVE-2017-12714
Vulnerability from fkie_nvd - Published: 2018-04-25 13:29 - Updated: 2024-11-21 03:10
Severity ?
Summary
Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted "RF wake-up" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/100523 | Third Party Advisory, VDB Entry | |
| ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/100523 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| abbott | accent_firmware | * | |
| abbott | accent | - | |
| abbott | anthem_firmware | * | |
| abbott | anthem | - | |
| abbott | accent_mri_firmware | * | |
| abbott | accent_mri | - | |
| abbott | accent_st_firmware | * | |
| abbott | accent_st | - | |
| abbott | assurity_firmware | * | |
| abbott | assurity | - | |
| abbott | allure_firmware | * | |
| abbott | allure | - | |
| abbott | assurity_mri_firmware | * | |
| abbott | assurity_mri | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abbott:accent_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BFF25F4E-CF32-41A5-9AEC-5CF2A1D70732",
"versionEndExcluding": "f0b.0e.7e",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abbott:accent:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7261AA88-1BD6-4CDF-AFC0-31FD7F52B9E7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abbott:anthem_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D6C940D7-5EA3-4D42-8FFE-0C38D2D0065E",
"versionEndExcluding": "f0b.0e.7e",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abbott:anthem:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4B28402F-D4DF-448B-8ED3-676E0B438331",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abbott:accent_mri_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BFC7CD6D-57F8-4479-A25C-9B9937FD3793",
"versionEndExcluding": "f10.08.6c",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abbott:accent_mri:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C752B8AA-8990-43DE-AB8B-57329E1E0AE1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abbott:accent_st_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3CCA1805-9253-4267-ACE9-B9F3BBB1549A",
"versionEndExcluding": "f10.08.6c",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abbott:accent_st:-:*:*:*:*:*:*:*",
"matchCriteriaId": "794620AF-C8D5-4511-B4AF-5E8B4347F558",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abbott:assurity_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0BF37E32-78D2-48CD-BF19-17533E3CB5DF",
"versionEndExcluding": "f14.07.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abbott:assurity:-:*:*:*:*:*:*:*",
"matchCriteriaId": "83B2EBFC-FB8A-402E-8C5C-118D4362B143",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abbott:allure_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "858B3E80-0179-4AD7-BC32-3AA87A7341C6",
"versionEndExcluding": "f14.07.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abbott:allure:-:*:*:*:*:*:*:*",
"matchCriteriaId": "65B30268-EC36-42C3-8028-D345DC22A3DC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abbott:assurity_mri_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "95E52CB5-DB4A-42FE-B963-CE891D3C1A95",
"versionEndExcluding": "f17.01.49",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abbott:assurity_mri:-:*:*:*:*:*:*:*",
"matchCriteriaId": "43025EB2-8644-4BC5-BC3D-D67305C504B7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted \"RF wake-up\" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities."
},
{
"lang": "es",
"value": "Los marcapasos de Abbott Laboratories fabricados antes del 28 de agosto de 2017 no restringen o limitan el n\u00famero de comandos \"RF wake-up\" formateados correctamente que pueden recibir. Esto puede permitir que un atacante cercano env\u00ede comandos repetidamente para reducir la bater\u00eda del marcapasos. Puntuaci\u00f3n base de CVSS v3: 5.3, cadena de vector CVSS: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott ha desarrollado una actualizaci\u00f3n de firmware para ayudar a mitigar las vulnerabilidades identificadas."
}
],
"id": "CVE-2017-12714",
"lastModified": "2024-11-21T03:10:04.977",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 6.1,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-04-25T13:29:00.287",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/100523"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/100523"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-920"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-920"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2017-12712
Vulnerability from fkie_nvd - Published: 2018-04-25 13:29 - Updated: 2024-11-21 03:10
Severity ?
Summary
The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3 base score: 7.5, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/100523 | Third Party Advisory, VDB Entry | |
| ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/100523 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| abbott | accent_firmware | * | |
| abbott | accent | - | |
| abbott | anthem_firmware | * | |
| abbott | anthem | - | |
| abbott | accent_mri_firmware | * | |
| abbott | accent_mri | - | |
| abbott | accent_st_firmware | * | |
| abbott | accent_st | - | |
| abbott | assurity_firmware | * | |
| abbott | assurity | - | |
| abbott | allure_firmware | * | |
| abbott | allure | - | |
| abbott | assurity_mri_firmware | * | |
| abbott | assurity_mri | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abbott:accent_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BFF25F4E-CF32-41A5-9AEC-5CF2A1D70732",
"versionEndExcluding": "f0b.0e.7e",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abbott:accent:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7261AA88-1BD6-4CDF-AFC0-31FD7F52B9E7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abbott:anthem_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D6C940D7-5EA3-4D42-8FFE-0C38D2D0065E",
"versionEndExcluding": "f0b.0e.7e",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abbott:anthem:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4B28402F-D4DF-448B-8ED3-676E0B438331",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abbott:accent_mri_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BFC7CD6D-57F8-4479-A25C-9B9937FD3793",
"versionEndExcluding": "f10.08.6c",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abbott:accent_mri:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C752B8AA-8990-43DE-AB8B-57329E1E0AE1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abbott:accent_st_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3CCA1805-9253-4267-ACE9-B9F3BBB1549A",
"versionEndExcluding": "f10.08.6c",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abbott:accent_st:-:*:*:*:*:*:*:*",
"matchCriteriaId": "794620AF-C8D5-4511-B4AF-5E8B4347F558",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abbott:assurity_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0BF37E32-78D2-48CD-BF19-17533E3CB5DF",
"versionEndExcluding": "f14.07.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abbott:assurity:-:*:*:*:*:*:*:*",
"matchCriteriaId": "83B2EBFC-FB8A-402E-8C5C-118D4362B143",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abbott:allure_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "858B3E80-0179-4AD7-BC32-3AA87A7341C6",
"versionEndExcluding": "f14.07.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abbott:allure:-:*:*:*:*:*:*:*",
"matchCriteriaId": "65B30268-EC36-42C3-8028-D345DC22A3DC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abbott:assurity_mri_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "95E52CB5-DB4A-42FE-B963-CE891D3C1A95",
"versionEndExcluding": "f17.01.49",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abbott:assurity_mri:-:*:*:*:*:*:*:*",
"matchCriteriaId": "43025EB2-8644-4BC5-BC3D-D67305C504B7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3 base score: 7.5, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities."
},
{
"lang": "es",
"value": "El algoritmo de autenticaci\u00f3n en los marcapasos de Abbott Laboratories fabricados antes del 28 de agosto de 2017, que est\u00e1 relacionado con una clave de autenticaci\u00f3n y una marca de tiempo, puede comprometerse u omitirse. Esto puede permitir que un atacante cercano env\u00ede comandos no autorizados al marcapasos mediante comunicaciones de radiofrecuencia. Puntuaci\u00f3n base de CVSS v3: 7.5, cadena de vector CVSS: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott ha desarrollado una actualizaci\u00f3n de firmware para ayudar a mitigar las vulnerabilidades identificadas."
}
],
"id": "CVE-2017-12712",
"lastModified": "2024-11-21T03:10:04.707",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-04-25T13:29:00.227",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/100523"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/100523"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2017-12714 (GCVE-0-2017-12714)
Vulnerability from cvelistv5 – Published: 2018-04-25 13:00 – Updated: 2024-09-17 00:16
VLAI?
Summary
Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted "RF wake-up" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.
Severity ?
No CVSS data available.
CWE
- CWE-920 - Improper Restriction of power consumption CWE-920
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Abbott Laboratories | Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI. |
Affected:
All versions of pacemakers manufactured prior to August 28, 2017
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T18:43:56.537Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"name": "100523",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/100523"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.",
"vendor": "Abbott Laboratories",
"versions": [
{
"status": "affected",
"version": "All versions of pacemakers manufactured prior to August 28, 2017"
}
]
}
],
"datePublic": "2017-08-29T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted \"RF wake-up\" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-920",
"description": "Improper Restriction of power consumption CWE-920",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-26T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"name": "100523",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/100523"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2017-08-29T00:00:00",
"ID": "CVE-2017-12714",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.",
"version": {
"version_data": [
{
"version_value": "All versions of pacemakers manufactured prior to August 28, 2017"
}
]
}
}
]
},
"vendor_name": "Abbott Laboratories"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted \"RF wake-up\" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Restriction of power consumption CWE-920"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"name": "100523",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/100523"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-12714",
"datePublished": "2018-04-25T13:00:00Z",
"dateReserved": "2017-08-09T00:00:00",
"dateUpdated": "2024-09-17T00:16:50.163Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-12712 (GCVE-0-2017-12712)
Vulnerability from cvelistv5 – Published: 2018-04-25 13:00 – Updated: 2024-09-17 03:48
VLAI?
Summary
The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3 base score: 7.5, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.
Severity ?
No CVSS data available.
CWE
- CWE-287 - Improper authentication CWE-287
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Abbott Laboratories | Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI. |
Affected:
All versions of pacemakers manufactured prior to August 28, 2017
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T18:43:56.613Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"name": "100523",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/100523"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.",
"vendor": "Abbott Laboratories",
"versions": [
{
"status": "affected",
"version": "All versions of pacemakers manufactured prior to August 28, 2017"
}
]
}
],
"datePublic": "2017-08-29T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3 base score: 7.5, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "Improper authentication CWE-287",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-26T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"name": "100523",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/100523"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2017-08-29T00:00:00",
"ID": "CVE-2017-12712",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.",
"version": {
"version_data": [
{
"version_value": "All versions of pacemakers manufactured prior to August 28, 2017"
}
]
}
}
]
},
"vendor_name": "Abbott Laboratories"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3 base score: 7.5, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper authentication CWE-287"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"name": "100523",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/100523"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-12712",
"datePublished": "2018-04-25T13:00:00Z",
"dateReserved": "2017-08-09T00:00:00",
"dateUpdated": "2024-09-17T03:48:37.996Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-12714 (GCVE-0-2017-12714)
Vulnerability from nvd – Published: 2018-04-25 13:00 – Updated: 2024-09-17 00:16
VLAI?
Summary
Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted "RF wake-up" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.
Severity ?
No CVSS data available.
CWE
- CWE-920 - Improper Restriction of power consumption CWE-920
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Abbott Laboratories | Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI. |
Affected:
All versions of pacemakers manufactured prior to August 28, 2017
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T18:43:56.537Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"name": "100523",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/100523"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.",
"vendor": "Abbott Laboratories",
"versions": [
{
"status": "affected",
"version": "All versions of pacemakers manufactured prior to August 28, 2017"
}
]
}
],
"datePublic": "2017-08-29T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted \"RF wake-up\" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-920",
"description": "Improper Restriction of power consumption CWE-920",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-26T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"name": "100523",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/100523"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2017-08-29T00:00:00",
"ID": "CVE-2017-12714",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.",
"version": {
"version_data": [
{
"version_value": "All versions of pacemakers manufactured prior to August 28, 2017"
}
]
}
}
]
},
"vendor_name": "Abbott Laboratories"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted \"RF wake-up\" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Restriction of power consumption CWE-920"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"name": "100523",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/100523"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-12714",
"datePublished": "2018-04-25T13:00:00Z",
"dateReserved": "2017-08-09T00:00:00",
"dateUpdated": "2024-09-17T00:16:50.163Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-12712 (GCVE-0-2017-12712)
Vulnerability from nvd – Published: 2018-04-25 13:00 – Updated: 2024-09-17 03:48
VLAI?
Summary
The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3 base score: 7.5, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.
Severity ?
No CVSS data available.
CWE
- CWE-287 - Improper authentication CWE-287
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Abbott Laboratories | Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI. |
Affected:
All versions of pacemakers manufactured prior to August 28, 2017
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T18:43:56.613Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"name": "100523",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/100523"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.",
"vendor": "Abbott Laboratories",
"versions": [
{
"status": "affected",
"version": "All versions of pacemakers manufactured prior to August 28, 2017"
}
]
}
],
"datePublic": "2017-08-29T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3 base score: 7.5, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "Improper authentication CWE-287",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-26T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"name": "100523",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/100523"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2017-08-29T00:00:00",
"ID": "CVE-2017-12712",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.",
"version": {
"version_data": [
{
"version_value": "All versions of pacemakers manufactured prior to August 28, 2017"
}
]
}
}
]
},
"vendor_name": "Abbott Laboratories"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3 base score: 7.5, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper authentication CWE-287"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"name": "100523",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/100523"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-12712",
"datePublished": "2018-04-25T13:00:00Z",
"dateReserved": "2017-08-09T00:00:00",
"dateUpdated": "2024-09-17T03:48:37.996Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}