Search criteria
18 vulnerabilities found for building_integration_system by bosch
FKIE_CVE-2023-29241
Vulnerability from fkie_nvd - Published: 2023-06-30 22:15 - Updated: 2024-11-21 07:56
Severity ?
8.1 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N
7.1 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
7.1 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
Summary
Improper Information in Cybersecurity Guidebook in Bosch Building Integration System (BIS) 5.0 may lead to wrong configuration which allows local users to access data via network
References
| URL | Tags | ||
|---|---|---|---|
| psirt@bosch.com | https://psirt.bosch.com/security-advisories/BOSCH-SA-988400-BT.html | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://psirt.bosch.com/security-advisories/BOSCH-SA-988400-BT.html | Mitigation, Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| bosch | building_integration_system | 5.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bosch:building_integration_system:5.0:*:*:*:*:*:*:*",
"matchCriteriaId": "1B374A1E-F057-482A-B187-B704B259BADB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Improper Information in Cybersecurity Guidebook in Bosch Building Integration System (BIS) 5.0 may lead to wrong configuration which allows local users to access data via network"
}
],
"id": "CVE-2023-29241",
"lastModified": "2024-11-21T07:56:44.813",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.2,
"source": "psirt@bosch.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-06-30T22:15:09.947",
"references": [
{
"source": "psirt@bosch.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-988400-BT.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-988400-BT.html"
}
],
"sourceIdentifier": "psirt@bosch.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-1112"
}
],
"source": "psirt@bosch.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-23842
Vulnerability from fkie_nvd - Published: 2022-01-19 21:15 - Updated: 2024-11-21 05:51
Severity ?
5.7 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
7.1 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
7.1 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
Summary
Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\'s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet.
References
| URL | Tags | ||
|---|---|---|---|
| psirt@bosch.com | https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html | Mitigation, Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| bosch | amc2_firmware | - | |
| bosch | amc2 | - | |
| bosch | access_management_system | 3.0 | |
| bosch | access_professional_edition | * | |
| bosch | building_integration_system | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:amc2_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A3032BCA-136A-470F-BD1D-A05FC5D22782",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:amc2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B51541D3-C8B6-4C5E-AC77-70A3F3D7D315",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bosch:access_management_system:3.0:*:*:*:*:*:*:*",
"matchCriteriaId": "C98BA3F6-853A-42EA-B7B9-7163AE2A7E74",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:*",
"matchCriteriaId": "28B735B8-BBBB-43BD-A06C-3297E44DA485",
"versionEndIncluding": "3.8.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "95FDA5B3-E4CB-4285-B3E3-C54F3394E9B2",
"versionEndExcluding": "4.9.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\\\u0027s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet."
},
{
"lang": "es",
"value": "La comunicaci\u00f3n con el AMC2 usa un algoritmo criptogr\u00e1fico de \u00faltima generaci\u00f3n para el cifrado sim\u00e9trico llamado Blowfish. Un atacante podr\u00eda recuperar la clave del firmware para descifrar el tr\u00e1fico de red entre el AMC2 y el sistema anfitri\u00f3n. As\u00ed, un atacante puede explotar esta vulnerabilidad para descifrar y modificar el tr\u00e1fico de red, descifrar e investigar el archivo de firmware del dispositivo y cambiar la configuraci\u00f3n del mismo. El atacante necesita tener acceso a la red local, normalmente incluso a la misma subred"
}
],
"id": "CVE-2021-23842",
"lastModified": "2024-11-21T05:51:55.670",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 3.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.1,
"impactScore": 3.6,
"source": "psirt@bosch.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-01-19T21:15:08.137",
"references": [
{
"source": "psirt@bosch.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
}
],
"sourceIdentifier": "psirt@bosch.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-321"
}
],
"source": "psirt@bosch.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-23843
Vulnerability from fkie_nvd - Published: 2022-01-19 21:15 - Updated: 2024-11-21 05:51
Severity ?
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
The Bosch software tools AccessIPConfig.exe and AmcIpConfig.exe are used to configure certains settings in AMC2 devices. The tool allows putting a password protection on configured devices to restrict access to the configuration of an AMC2. An attacker can circumvent this protection and make unauthorized changes to configuration data on the device. An attacker can exploit this vulnerability to manipulate the device\'s configuration or make it unresponsive in the local network. The attacker needs to have access to the local network, typically even the same subnet.
References
| URL | Tags | ||
|---|---|---|---|
| psirt@bosch.com | https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html | Mitigation, Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| bosch | amc2_firmware | - | |
| bosch | amc2 | - | |
| bosch | access_management_system | 3.0 | |
| bosch | access_professional_edition | * | |
| bosch | building_integration_system | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:amc2_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A3032BCA-136A-470F-BD1D-A05FC5D22782",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:amc2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B51541D3-C8B6-4C5E-AC77-70A3F3D7D315",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bosch:access_management_system:3.0:*:*:*:*:*:*:*",
"matchCriteriaId": "C98BA3F6-853A-42EA-B7B9-7163AE2A7E74",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:*",
"matchCriteriaId": "28B735B8-BBBB-43BD-A06C-3297E44DA485",
"versionEndIncluding": "3.8.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "95FDA5B3-E4CB-4285-B3E3-C54F3394E9B2",
"versionEndExcluding": "4.9.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The Bosch software tools AccessIPConfig.exe and AmcIpConfig.exe are used to configure certains settings in AMC2 devices. The tool allows putting a password protection on configured devices to restrict access to the configuration of an AMC2. An attacker can circumvent this protection and make unauthorized changes to configuration data on the device. An attacker can exploit this vulnerability to manipulate the device\\\u0027s configuration or make it unresponsive in the local network. The attacker needs to have access to the local network, typically even the same subnet."
},
{
"lang": "es",
"value": "Las herramientas de software de Bosch AccessIPConfig.exe y AmcIpConfig.exe son usadas para configurar determinados ajustes en los dispositivos AMC2. La herramienta permite poner una contrase\u00f1a de protecci\u00f3n en los dispositivos configurados para restringir el acceso a la configuraci\u00f3n de un AMC2. Un atacante puede burlar esta protecci\u00f3n y realizar cambios no autorizados en los datos de configuraci\u00f3n del dispositivo. Un atacante puede explotar esta vulnerabilidad para manipular la configuraci\u00f3n del dispositivo o hacer que no responda en la red local. El atacante necesita tener acceso a la red local, normalmente incluso a la misma subred"
}
],
"id": "CVE-2021-23843",
"lastModified": "2024-11-21T05:51:55.817",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "psirt@bosch.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-01-19T21:15:08.190",
"references": [
{
"source": "psirt@bosch.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
}
],
"sourceIdentifier": "psirt@bosch.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "psirt@bosch.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-23859
Vulnerability from fkie_nvd - Published: 2021-12-08 22:15 - Updated: 2024-11-21 05:51
Severity ?
9.1 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
An unauthenticated attacker is able to send a special HTTP request, that causes a service to crash. In case of a standalone VRM or BVMS with VRM installation this crash also opens the possibility to send further unauthenticated commands to the service. On some products the interface is only local accessible lowering the CVSS base score. For a list of modified CVSS scores, please see the official Bosch Advisory Appendix chapter Modified CVSS Scores for CVE-2021-23859
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0B9DD276-15C0-4942-8899-553F7C190320",
"versionEndIncluding": "9.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "989D5F9A-D223-4070-82AE-FA79E8B2572C",
"versionEndExcluding": "10.0.2",
"versionStartIncluding": "10.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:bosch_video_management_system:10.1:*:*:*:*:*:*:*",
"matchCriteriaId": "57FA3EF2-6A7C-46FD-A758-92045A3A2DEE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:bosch_video_management_system:11.0:*:*:*:*:*:*:*",
"matchCriteriaId": "1FF22168-E2A2-47B8-B9BC-104FF1CFDF30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D54B21E5-8C3E-423F-8E49-9F05B41D540B",
"versionEndIncluding": "3.81",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "31D1E38A-C0F8-421B-B837-3D2FBD132A18",
"versionEndIncluding": "3.82.0057",
"versionStartIncluding": "3.82",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7171D63A-3A1A-4235-9317-009D7C85A93C",
"versionEndIncluding": "3.83.0021",
"versionStartIncluding": "3.83",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "31572EBA-C58A-46E8-88EA-ADE04578E039",
"versionEndIncluding": "4.00.0070",
"versionStartIncluding": "4.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:divar_ip_5000_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E2C1615D-2E5F-4D49-B937-05C81AB5414C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:bosch:divar_ip_7000_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7CCD42BE-E4B7-43FC-95FB-C97704E5C268",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:access_easy_controller_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BD36E262-9272-4A72-B883-CBD84123BEDB",
"versionEndIncluding": "2.9.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:access_easy_controller:-:*:*:*:*:*:*:*",
"matchCriteriaId": "50324AEF-BF89-4AAC-B467-FCF87796AB01",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:*",
"matchCriteriaId": "28B735B8-BBBB-43BD-A06C-3297E44DA485",
"versionEndIncluding": "3.8.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B01DD4E9-DD97-4B14-8F9E-5EB953939097",
"versionEndIncluding": "4.9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:video_recording_manager_exporter:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E7DD7CA3-05D7-4AF1-AD9B-117CC3FF22B5",
"versionEndIncluding": "2.10.0008",
"versionStartIncluding": "2.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated attacker is able to send a special HTTP request, that causes a service to crash. In case of a standalone VRM or BVMS with VRM installation this crash also opens the possibility to send further unauthenticated commands to the service. On some products the interface is only local accessible lowering the CVSS base score. For a list of modified CVSS scores, please see the official Bosch Advisory Appendix chapter Modified CVSS Scores for CVE-2021-23859"
},
{
"lang": "es",
"value": "Un atacante no autenticado es capaz de enviar una petici\u00f3n HTTP especial, que causa el bloqueo de un servicio. En el caso de un VRM independiente o de un BVMS con instalaci\u00f3n de VRM, este bloqueo tambi\u00e9n abre la posibilidad de enviar m\u00e1s comandos no autenticados al servicio. En algunos productos, la interfaz s\u00f3lo es accesible localmente, reduciendo la puntuaci\u00f3n base CVSS. Para ver una lista de las puntuaciones CVSS modificadas, consulte el cap\u00edtulo del ap\u00e9ndice oficial de Bosch Advisory Puntuaciones CVSS modificadas para CVE-2021-23859"
}
],
"id": "CVE-2021-23859",
"lastModified": "2024-11-21T05:51:58.003",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2,
"source": "psirt@bosch.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-08T22:15:08.413",
"references": [
{
"source": "psirt@bosch.com",
"tags": [
"Vendor Advisory"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
],
"sourceIdentifier": "psirt@bosch.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-703"
}
],
"source": "psirt@bosch.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-755"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-6957
Vulnerability from fkie_nvd - Published: 2019-05-29 19:29 - Updated: 2024-11-21 04:47
Severity ?
Summary
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3B5A626A-B735-4E0B-8BAC-0A26A02D6599",
"versionEndIncluding": "3.7",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:bosch_video_client:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EFBF448F-005B-48FF-B796-DBC8EAA35323",
"versionEndExcluding": "1.7.6.079",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0B9DD276-15C0-4942-8899-553F7C190320",
"versionEndIncluding": "9.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D92BA2E1-8554-4F13-938D-855BC33A59C9",
"versionEndIncluding": "4.4",
"versionStartIncluding": "2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:building_integration_system:4.5:*:*:*:*:*:*:*",
"matchCriteriaId": "8585CAE6-8A82-4338-A510-BB1798AC0BE3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:building_integration_system:4.6:*:*:*:*:*:*:*",
"matchCriteriaId": "05B6AD6C-8FCC-473C-9D9A-91EA6C9A8E3E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:building_integration_system:4.6.1:*:*:*:*:*:*:*",
"matchCriteriaId": "8E219B63-2423-4D01-BDA9-8128B5E0DC24",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:configuration_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4100A710-A356-4D54-BADE-F6C16947C3F0",
"versionEndExcluding": "6.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "526B56A8-3106-44C1-8C77-B22995A98C86",
"versionEndExcluding": "3.71.0032",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "31523A17-95B3-42D6-B176-1814A91239C9",
"versionEndExcluding": "3.81.0048",
"versionStartIncluding": "3.81",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:video_sdk:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F421BFB6-5448-4B86-AEB6-062682F56C10",
"versionEndExcluding": "6.32.0099",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DAA61FF3-D717-4A33-B175-E418B11A0BEE",
"versionEndExcluding": "6.43.0023",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8CD3166A-2B9C-4641-803C-BC4EBEF035F1",
"versionEndExcluding": "6.45.0008",
"versionStartIncluding": "6.45",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:dip_2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EC039957-2F53-4080-AB7B-1E2AA4F81790",
"versionEndExcluding": "0380.037",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:dip_2000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BC890021-B200-4743-AB51-03BDC9CB1351",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:dip_3000_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FAE1D3ED-FE23-4F3B-AE75-2FFBDEF5FDAF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:dip_3000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "ABB194FD-9D50-4420-925F-48E4B2D0C2E7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:dip_5000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E0062D5B-DF47-47AB-A6E7-B00BEA2FBA1E",
"versionEndExcluding": "038.037",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:dip_5000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7EFAEE79-2B7C-4F74-B663-F49F2606AF41",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:dip_7000_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7731276E-38B9-4B01-B4A3-092A49150B9A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:dip_7000:gen1:*:*:*:*:*:*:*",
"matchCriteriaId": "C8FDECC6-46D7-4EAF-9CBC-06D2F18AADA5",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:bosch:dip_7000:gen2:*:*:*:*:*:*:*",
"matchCriteriaId": "ED2FF548-939C-4F10-A3E7-02DF342A35B0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.8.5:*:*:*:*:*:*:*",
"matchCriteriaId": "DA449D4D-8AF0-4792-A9CA-8195A4E0082B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.0:*:*:*:*:*:*:*",
"matchCriteriaId": "DE6EFC6A-351D-4571-A1F7-1E6AC0B77B22",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.1:*:*:*:*:*:*:*",
"matchCriteriaId": "A6B97D59-8692-449F-BA59-C2C2F3E0FDDB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.3:*:*:*:*:*:*:*",
"matchCriteriaId": "A3C2E4AA-B871-4B0B-8BD0-8D5440BE8144",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:access_easy_controller:-:*:*:*:*:*:*:*",
"matchCriteriaId": "50324AEF-BF89-4AAC-B467-FCF87796AB01",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface."
},
{
"lang": "es",
"value": "Una vulnerabilidad de seguridad encontrada recientemente impacta a todas las versiones 9.0 y anteriores de Bosch Video Management System (BVMS), DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). La vulnerabilidad potencialmente permite la ejecuci\u00f3n no autorizada de c\u00f3digo en el sistema por medio de la interfaz de red."
}
],
"id": "CVE-2019-6957",
"lastModified": "2024-11-21T04:47:18.127",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "cve@mitre.org",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-05-29T19:29:00.657",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-6958
Vulnerability from fkie_nvd - Published: 2019-05-29 19:29 - Updated: 2024-11-21 04:47
Severity ?
Summary
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| bosch | access_professional_edition | * | |
| bosch | bosch_video_client | * | |
| bosch | bosch_video_management_system | * | |
| bosch | building_integration_system | * | |
| bosch | building_integration_system | 4.5 | |
| bosch | building_integration_system | 4.6 | |
| bosch | building_integration_system | 4.6.1 | |
| bosch | configuration_manager | * | |
| bosch | video_sdk | * | |
| bosch | dip_2000_firmware | * | |
| bosch | dip_2000 | - | |
| bosch | dip_3000_firmware | - | |
| bosch | dip_3000 | - | |
| bosch | dip_5000_firmware | * | |
| bosch | dip_5000 | - | |
| bosch | dip_7000_firmware | - | |
| bosch | dip_7000 | gen1 | |
| bosch | dip_7000 | gen2 | |
| bosch | access_easy_controller_firmware | 2.1.8.5 | |
| bosch | access_easy_controller_firmware | 2.1.9.0 | |
| bosch | access_easy_controller_firmware | 2.1.9.1 | |
| bosch | access_easy_controller_firmware | 2.1.9.3 | |
| bosch | access_easy_controller | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3B5A626A-B735-4E0B-8BAC-0A26A02D6599",
"versionEndIncluding": "3.7",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:bosch_video_client:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EFBF448F-005B-48FF-B796-DBC8EAA35323",
"versionEndExcluding": "1.7.6.079",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0B9DD276-15C0-4942-8899-553F7C190320",
"versionEndIncluding": "9.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D92BA2E1-8554-4F13-938D-855BC33A59C9",
"versionEndIncluding": "4.4",
"versionStartIncluding": "2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:building_integration_system:4.5:*:*:*:*:*:*:*",
"matchCriteriaId": "8585CAE6-8A82-4338-A510-BB1798AC0BE3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:building_integration_system:4.6:*:*:*:*:*:*:*",
"matchCriteriaId": "05B6AD6C-8FCC-473C-9D9A-91EA6C9A8E3E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:building_integration_system:4.6.1:*:*:*:*:*:*:*",
"matchCriteriaId": "8E219B63-2423-4D01-BDA9-8128B5E0DC24",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:configuration_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4100A710-A356-4D54-BADE-F6C16947C3F0",
"versionEndExcluding": "6.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:bosch:video_sdk:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F421BFB6-5448-4B86-AEB6-062682F56C10",
"versionEndExcluding": "6.32.0099",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:dip_2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EC039957-2F53-4080-AB7B-1E2AA4F81790",
"versionEndExcluding": "0380.037",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:dip_2000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BC890021-B200-4743-AB51-03BDC9CB1351",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:dip_3000_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FAE1D3ED-FE23-4F3B-AE75-2FFBDEF5FDAF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:dip_3000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "ABB194FD-9D50-4420-925F-48E4B2D0C2E7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:dip_5000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E0062D5B-DF47-47AB-A6E7-B00BEA2FBA1E",
"versionEndExcluding": "038.037",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:dip_5000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7EFAEE79-2B7C-4F74-B663-F49F2606AF41",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:dip_7000_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7731276E-38B9-4B01-B4A3-092A49150B9A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:dip_7000:gen1:*:*:*:*:*:*:*",
"matchCriteriaId": "C8FDECC6-46D7-4EAF-9CBC-06D2F18AADA5",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:bosch:dip_7000:gen2:*:*:*:*:*:*:*",
"matchCriteriaId": "ED2FF548-939C-4F10-A3E7-02DF342A35B0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.8.5:*:*:*:*:*:*:*",
"matchCriteriaId": "DA449D4D-8AF0-4792-A9CA-8195A4E0082B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.0:*:*:*:*:*:*:*",
"matchCriteriaId": "DE6EFC6A-351D-4571-A1F7-1E6AC0B77B22",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.1:*:*:*:*:*:*:*",
"matchCriteriaId": "A6B97D59-8692-449F-BA59-C2C2F3E0FDDB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.3:*:*:*:*:*:*:*",
"matchCriteriaId": "A3C2E4AA-B871-4B0B-8BD0-8D5440BE8144",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:access_easy_controller:-:*:*:*:*:*:*:*",
"matchCriteriaId": "50324AEF-BF89-4AAC-B467-FCF87796AB01",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \"CWE-284: Improper Access Control.\" This vulnerability, for example, allows a potential attacker to delete video or read video data."
},
{
"lang": "es",
"value": "Una vulnerabilidad de seguridad encontrada recientemente impacta a todas las versiones 9.0 y siguientes de Bosch Video Management System (BVMS), DIVAR IP 2000, 3000, 5000 y 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). El puerto de red RCP+ permite acceso sin autenticaci\u00f3n. La adici\u00f3n de la funci\u00f3n authentication a la biblioteca correspondiente soluciona el problema. El problema es clasificado como \"CWE-284: Improper Access Control\". Esta vulnerabilidad, por ejemplo, permite a un potencial atacante eliminar un v\u00eddeo o leer datos de un v\u00eddeo."
}
],
"id": "CVE-2019-6958",
"lastModified": "2024-11-21T04:47:18.280",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 6.4,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "cve@mitre.org",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-05-29T19:29:00.703",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2023-29241 (GCVE-0-2023-29241)
Vulnerability from cvelistv5 – Published: 2023-06-30 00:00 – Updated: 2024-11-26 19:59
VLAI?
Summary
Improper Information in Cybersecurity Guidebook in Bosch Building Integration System (BIS) 5.0 may lead to wrong configuration which allows local users to access data via network
Severity ?
8.1 (High)
CWE
- CWE-1112 - Incomplete Documentation of Program Execution
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:00:15.894Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-988400-BT.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29241",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T19:59:44.994388Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T19:59:56.176Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BIS",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "5.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Information in Cybersecurity Guidebook in Bosch Building Integration System (BIS) 5.0 may lead to wrong configuration which allows local users to access data via network"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1112",
"description": "CWE-1112 Incomplete Documentation of Program Execution",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-30T00:00:00",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-988400-BT.html"
}
],
"source": {
"discovery": "INTERNAL"
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-29241",
"datePublished": "2023-06-30T00:00:00",
"dateReserved": "2023-06-01T00:00:00",
"dateUpdated": "2024-11-26T19:59:56.176Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-23843 (GCVE-0-2021-23843)
Vulnerability from cvelistv5 – Published: 2022-01-19 20:38 – Updated: 2024-09-16 23:01
VLAI?
Summary
The Bosch software tools AccessIPConfig.exe and AmcIpConfig.exe are used to configure certains settings in AMC2 devices. The tool allows putting a password protection on configured devices to restrict access to the configuration of an AMC2. An attacker can circumvent this protection and make unauthorized changes to configuration data on the device. An attacker can exploit this vulnerability to manipulate the device\'s configuration or make it unresponsive in the local network. The attacker needs to have access to the local network, typically even the same subnet.
Severity ?
8.8 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:14:09.225Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AMS",
"vendor": "Bosch",
"versions": [
{
"lessThan": "4.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "APE",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.8.x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "BIS",
"vendor": "Bosch",
"versions": [
{
"lessThan": "4.9.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "AMC2",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"datePublic": "2022-01-19T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The Bosch software tools AccessIPConfig.exe and AmcIpConfig.exe are used to configure certains settings in AMC2 devices. The tool allows putting a password protection on configured devices to restrict access to the configuration of an AMC2. An attacker can circumvent this protection and make unauthorized changes to configuration data on the device. An attacker can exploit this vulnerability to manipulate the device\\\u0027s configuration or make it unresponsive in the local network. The attacker needs to have access to the local network, typically even the same subnet."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-19T20:38:55",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
}
],
"source": {
"advisory": "BOSCH-SA-940448-BT",
"discovery": "EXTERNAL"
},
"title": "Lack of authentication mechanisms on the device",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2022-01-19",
"ID": "CVE-2021-23843",
"STATE": "PUBLIC",
"TITLE": "Lack of authentication mechanisms on the device"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AMS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0"
}
]
}
},
{
"product_name": "APE",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "3.8.x"
}
]
}
},
{
"product_name": "BIS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.9.1"
}
]
}
},
{
"product_name": "AMC2",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Bosch software tools AccessIPConfig.exe and AmcIpConfig.exe are used to configure certains settings in AMC2 devices. The tool allows putting a password protection on configured devices to restrict access to the configuration of an AMC2. An attacker can circumvent this protection and make unauthorized changes to configuration data on the device. An attacker can exploit this vulnerability to manipulate the device\\\u0027s configuration or make it unresponsive in the local network. The attacker needs to have access to the local network, typically even the same subnet."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-940448-BT",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2021-23843",
"datePublished": "2022-01-19T20:38:55.465356Z",
"dateReserved": "2021-01-12T00:00:00",
"dateUpdated": "2024-09-16T23:01:30.470Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-23842 (GCVE-0-2021-23842)
Vulnerability from cvelistv5 – Published: 2022-01-19 20:38 – Updated: 2024-09-16 21:56
VLAI?
Summary
Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\'s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet.
Severity ?
5.7 (Medium)
CWE
- CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:14:09.336Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AMS",
"vendor": "Bosch",
"versions": [
{
"lessThan": "4.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "APE",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.8.x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "BIS",
"vendor": "Bosch",
"versions": [
{
"lessThan": "4.9.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "AMC2",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"datePublic": "2022-01-19T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\\\u0027s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321 Use of Hard-coded Cryptographic Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-19T20:38:54",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
}
],
"source": {
"advisory": "BOSCH-SA-940448-BT",
"discovery": "EXTERNAL"
},
"title": "Use of Hard-coded Cryptographic Key",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2022-01-19",
"ID": "CVE-2021-23842",
"STATE": "PUBLIC",
"TITLE": "Use of Hard-coded Cryptographic Key"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AMS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0"
}
]
}
},
{
"product_name": "APE",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "3.8.x"
}
]
}
},
{
"product_name": "BIS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.9.1"
}
]
}
},
{
"product_name": "AMC2",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\\\u0027s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-321 Use of Hard-coded Cryptographic Key"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-940448-BT",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2021-23842",
"datePublished": "2022-01-19T20:38:54.368368Z",
"dateReserved": "2021-01-12T00:00:00",
"dateUpdated": "2024-09-16T21:56:51.896Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-23859 (GCVE-0-2021-23859)
Vulnerability from cvelistv5 – Published: 2021-12-08 21:17 – Updated: 2024-09-16 19:45
VLAI?
Summary
An unauthenticated attacker is able to send a special HTTP request, that causes a service to crash. In case of a standalone VRM or BVMS with VRM installation this crash also opens the possibility to send further unauthenticated commands to the service. On some products the interface is only local accessible lowering the CVSS base score. For a list of modified CVSS scores, please see the official Bosch Advisory Appendix chapter Modified CVSS Scores for CVE-2021-23859
Severity ?
9.1 (Critical)
CWE
- CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch | BVMS |
Affected:
unspecified , ≤ 9.0.0
(custom)
Affected: 11.0 , < 11.0.0 (custom) Affected: 10.0 , < 10.0.2 (custom) Affected: 10.1 , < 10.1.1 (custom) |
||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:14:09.402Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "BVMS",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "9.0.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThan": "11.0.0",
"status": "affected",
"version": "11.0",
"versionType": "custom"
},
{
"lessThan": "10.0.2",
"status": "affected",
"version": "10.0",
"versionType": "custom"
},
{
"lessThan": "10.1.1",
"status": "affected",
"version": "10.1",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP 7000 R2",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "DIVAR IP all-in-one 5000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "DIVAR IP all-in-one 7000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "VRM",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.00.0070",
"status": "affected",
"version": "4.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "3.83.0021",
"status": "affected",
"version": "3.83",
"versionType": "custom"
},
{
"lessThanOrEqual": "3.82.0057",
"status": "affected",
"version": "3.82",
"versionType": "custom"
}
]
},
{
"product": "VRM Exporter",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "2.10.0008",
"status": "affected",
"version": "2.1",
"versionType": "custom"
}
]
},
{
"product": "APE",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.8.x.x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "AEC",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "2.9.1.x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "BIS",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "4.9",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.8",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-12-08T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated attacker is able to send a special HTTP request, that causes a service to crash. In case of a standalone VRM or BVMS with VRM installation this crash also opens the possibility to send further unauthenticated commands to the service. On some products the interface is only local accessible lowering the CVSS base score. For a list of modified CVSS scores, please see the official Bosch Advisory Appendix chapter Modified CVSS Scores for CVE-2021-23859"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-703",
"description": "CWE-703 Improper Check or Handling of Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-08T21:17:23",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
],
"source": {
"advisory": "BOSCH-SA-043434-BT",
"discovery": "EXTERNAL"
},
"title": "Denial of Service and Authentication Bypass Vulnerability in multiple Bosch products",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2021-12-08",
"ID": "CVE-2021-23859",
"STATE": "PUBLIC",
"TITLE": "Denial of Service and Authentication Bypass Vulnerability in multiple Bosch products"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "BVMS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "11.0",
"version_value": "11.0.0"
},
{
"version_affected": "\u003c",
"version_name": "10.0",
"version_value": "10.0.2"
},
{
"version_affected": "\u003c",
"version_name": "10.1",
"version_value": "10.1.1"
},
{
"version_affected": "\u003c=",
"version_value": "9.0.0"
}
]
}
},
{
"product_name": "DIVAR IP 7000 R2",
"version": {
"version_data": [
{
"configuration": "using vulnerable BVMS version",
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "DIVAR IP all-in-one 5000",
"version": {
"version_data": [
{
"configuration": "using vulnerable BVMS or VRM version",
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "DIVAR IP all-in-one 7000",
"version": {
"version_data": [
{
"configuration": "using vulnerable BVMS or VRM version",
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "VRM",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "4.0",
"version_value": "4.00.0070"
},
{
"version_affected": "\u003c=",
"version_name": "3.83",
"version_value": "3.83.0021"
},
{
"version_affected": "\u003c=",
"version_name": "3.82",
"version_value": "3.82.0057"
},
{
"version_affected": "\u003c=",
"version_value": "3.81"
}
]
}
},
{
"product_name": "VRM Exporter",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "2.1",
"version_value": "2.10.0008"
}
]
}
},
{
"product_name": "APE",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "3.8.x.x"
}
]
}
},
{
"product_name": "AEC",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "2.9.1.x"
}
]
}
},
{
"product_name": "BIS",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "4.9"
},
{
"version_affected": "\u003c=",
"version_value": "4.8"
},
{
"version_affected": "\u003c=",
"version_value": "4.7"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An unauthenticated attacker is able to send a special HTTP request, that causes a service to crash. In case of a standalone VRM or BVMS with VRM installation this crash also opens the possibility to send further unauthenticated commands to the service. On some products the interface is only local accessible lowering the CVSS base score. For a list of modified CVSS scores, please see the official Bosch Advisory Appendix chapter Modified CVSS Scores for CVE-2021-23859"
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-703 Improper Check or Handling of Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-043434-BT",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2021-23859",
"datePublished": "2021-12-08T21:17:23.528438Z",
"dateReserved": "2021-01-12T00:00:00",
"dateUpdated": "2024-09-16T19:45:43.543Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6957 (GCVE-0-2019-6957)
Vulnerability from cvelistv5 – Published: 2019-05-29 18:55 – Updated: 2024-09-16 16:38
VLAI?
Summary
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.396Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2019-04-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-29T18:55:20",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
],
"solutions": [
{
"lang": "en",
"value": "In cases where a software update is not possible, a reduction in the system\u2019s network exposure is advised. Internet-accessible installations should be firewalled, whilst additional steps like network isolation by VLAN, IP filtering features of the devices and other technologies should be used to decrease the exposure of vulnerable systems. In addition the firewall on the hosts shall be activated and set according to BVMS and BIS configuration manual. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems",
"x_generator": {
"engine": "Vulnogram 0.0.6"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-04-04T22:00:00.000Z",
"ID": "CVE-2019-6957",
"STATE": "PUBLIC",
"TITLE": "Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf",
"refsource": "CONFIRM",
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
]
},
"solution": [
{
"lang": "en",
"value": "In cases where a software update is not possible, a reduction in the system\u2019s network exposure is advised. Internet-accessible installations should be firewalled, whilst additional steps like network isolation by VLAN, IP filtering features of the devices and other technologies should be used to decrease the exposure of vulnerable systems. In addition the firewall on the hosts shall be activated and set according to BVMS and BIS configuration manual. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-6957",
"datePublished": "2019-05-29T18:55:20.387906Z",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-09-16T16:38:39.411Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6958 (GCVE-0-2019-6958)
Vulnerability from cvelistv5 – Published: 2019-05-29 18:47 – Updated: 2024-09-17 00:46
VLAI?
Summary
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.392Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2019-03-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \"CWE-284: Improper Access Control.\" This vulnerability, for example, allows a potential attacker to delete video or read video data."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-29T18:47:37",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
}
],
"solutions": [
{
"lang": "en",
"value": "The recommended approach is to update the software to a fixed version as soon as possible. Until a fixed software version is installed, the mitigation approaches firewalling, and IP filtering can be utilized. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Improper Access Control for Bosch Video Systems, PSIM and Access Control Systems",
"x_generator": {
"engine": "Vulnogram 0.0.6"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-03-04T23:00:00.000Z",
"ID": "CVE-2019-6958",
"STATE": "PUBLIC",
"TITLE": "Improper Access Control for Bosch Video Systems, PSIM and Access Control Systems"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \"CWE-284: Improper Access Control.\" This vulnerability, for example, allows a potential attacker to delete video or read video data."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf",
"refsource": "CONFIRM",
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
}
]
},
"solution": [
{
"lang": "en",
"value": "The recommended approach is to update the software to a fixed version as soon as possible. Until a fixed software version is installed, the mitigation approaches firewalling, and IP filtering can be utilized. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-6958",
"datePublished": "2019-05-29T18:47:37.354175Z",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-09-17T00:46:00.474Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-29241 (GCVE-0-2023-29241)
Vulnerability from nvd – Published: 2023-06-30 00:00 – Updated: 2024-11-26 19:59
VLAI?
Summary
Improper Information in Cybersecurity Guidebook in Bosch Building Integration System (BIS) 5.0 may lead to wrong configuration which allows local users to access data via network
Severity ?
8.1 (High)
CWE
- CWE-1112 - Incomplete Documentation of Program Execution
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:00:15.894Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-988400-BT.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29241",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T19:59:44.994388Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T19:59:56.176Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BIS",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "5.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Information in Cybersecurity Guidebook in Bosch Building Integration System (BIS) 5.0 may lead to wrong configuration which allows local users to access data via network"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1112",
"description": "CWE-1112 Incomplete Documentation of Program Execution",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-30T00:00:00",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-988400-BT.html"
}
],
"source": {
"discovery": "INTERNAL"
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-29241",
"datePublished": "2023-06-30T00:00:00",
"dateReserved": "2023-06-01T00:00:00",
"dateUpdated": "2024-11-26T19:59:56.176Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-23843 (GCVE-0-2021-23843)
Vulnerability from nvd – Published: 2022-01-19 20:38 – Updated: 2024-09-16 23:01
VLAI?
Summary
The Bosch software tools AccessIPConfig.exe and AmcIpConfig.exe are used to configure certains settings in AMC2 devices. The tool allows putting a password protection on configured devices to restrict access to the configuration of an AMC2. An attacker can circumvent this protection and make unauthorized changes to configuration data on the device. An attacker can exploit this vulnerability to manipulate the device\'s configuration or make it unresponsive in the local network. The attacker needs to have access to the local network, typically even the same subnet.
Severity ?
8.8 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:14:09.225Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AMS",
"vendor": "Bosch",
"versions": [
{
"lessThan": "4.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "APE",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.8.x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "BIS",
"vendor": "Bosch",
"versions": [
{
"lessThan": "4.9.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "AMC2",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"datePublic": "2022-01-19T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The Bosch software tools AccessIPConfig.exe and AmcIpConfig.exe are used to configure certains settings in AMC2 devices. The tool allows putting a password protection on configured devices to restrict access to the configuration of an AMC2. An attacker can circumvent this protection and make unauthorized changes to configuration data on the device. An attacker can exploit this vulnerability to manipulate the device\\\u0027s configuration or make it unresponsive in the local network. The attacker needs to have access to the local network, typically even the same subnet."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-19T20:38:55",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
}
],
"source": {
"advisory": "BOSCH-SA-940448-BT",
"discovery": "EXTERNAL"
},
"title": "Lack of authentication mechanisms on the device",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2022-01-19",
"ID": "CVE-2021-23843",
"STATE": "PUBLIC",
"TITLE": "Lack of authentication mechanisms on the device"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AMS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0"
}
]
}
},
{
"product_name": "APE",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "3.8.x"
}
]
}
},
{
"product_name": "BIS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.9.1"
}
]
}
},
{
"product_name": "AMC2",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Bosch software tools AccessIPConfig.exe and AmcIpConfig.exe are used to configure certains settings in AMC2 devices. The tool allows putting a password protection on configured devices to restrict access to the configuration of an AMC2. An attacker can circumvent this protection and make unauthorized changes to configuration data on the device. An attacker can exploit this vulnerability to manipulate the device\\\u0027s configuration or make it unresponsive in the local network. The attacker needs to have access to the local network, typically even the same subnet."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-940448-BT",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2021-23843",
"datePublished": "2022-01-19T20:38:55.465356Z",
"dateReserved": "2021-01-12T00:00:00",
"dateUpdated": "2024-09-16T23:01:30.470Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-23842 (GCVE-0-2021-23842)
Vulnerability from nvd – Published: 2022-01-19 20:38 – Updated: 2024-09-16 21:56
VLAI?
Summary
Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\'s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet.
Severity ?
5.7 (Medium)
CWE
- CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:14:09.336Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AMS",
"vendor": "Bosch",
"versions": [
{
"lessThan": "4.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "APE",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.8.x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "BIS",
"vendor": "Bosch",
"versions": [
{
"lessThan": "4.9.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "AMC2",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"datePublic": "2022-01-19T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\\\u0027s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321 Use of Hard-coded Cryptographic Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-19T20:38:54",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
}
],
"source": {
"advisory": "BOSCH-SA-940448-BT",
"discovery": "EXTERNAL"
},
"title": "Use of Hard-coded Cryptographic Key",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2022-01-19",
"ID": "CVE-2021-23842",
"STATE": "PUBLIC",
"TITLE": "Use of Hard-coded Cryptographic Key"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AMS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.0"
}
]
}
},
{
"product_name": "APE",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "3.8.x"
}
]
}
},
{
"product_name": "BIS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.9.1"
}
]
}
},
{
"product_name": "AMC2",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\\\u0027s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-321 Use of Hard-coded Cryptographic Key"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-940448-BT",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2021-23842",
"datePublished": "2022-01-19T20:38:54.368368Z",
"dateReserved": "2021-01-12T00:00:00",
"dateUpdated": "2024-09-16T21:56:51.896Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-23859 (GCVE-0-2021-23859)
Vulnerability from nvd – Published: 2021-12-08 21:17 – Updated: 2024-09-16 19:45
VLAI?
Summary
An unauthenticated attacker is able to send a special HTTP request, that causes a service to crash. In case of a standalone VRM or BVMS with VRM installation this crash also opens the possibility to send further unauthenticated commands to the service. On some products the interface is only local accessible lowering the CVSS base score. For a list of modified CVSS scores, please see the official Bosch Advisory Appendix chapter Modified CVSS Scores for CVE-2021-23859
Severity ?
9.1 (Critical)
CWE
- CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch | BVMS |
Affected:
unspecified , ≤ 9.0.0
(custom)
Affected: 11.0 , < 11.0.0 (custom) Affected: 10.0 , < 10.0.2 (custom) Affected: 10.1 , < 10.1.1 (custom) |
||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:14:09.402Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "BVMS",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "9.0.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThan": "11.0.0",
"status": "affected",
"version": "11.0",
"versionType": "custom"
},
{
"lessThan": "10.0.2",
"status": "affected",
"version": "10.0",
"versionType": "custom"
},
{
"lessThan": "10.1.1",
"status": "affected",
"version": "10.1",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP 7000 R2",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "DIVAR IP all-in-one 5000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "DIVAR IP all-in-one 7000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "VRM",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.81",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.00.0070",
"status": "affected",
"version": "4.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "3.83.0021",
"status": "affected",
"version": "3.83",
"versionType": "custom"
},
{
"lessThanOrEqual": "3.82.0057",
"status": "affected",
"version": "3.82",
"versionType": "custom"
}
]
},
{
"product": "VRM Exporter",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "2.10.0008",
"status": "affected",
"version": "2.1",
"versionType": "custom"
}
]
},
{
"product": "APE",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.8.x.x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "AEC",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "2.9.1.x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "BIS",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "4.9",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.8",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-12-08T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated attacker is able to send a special HTTP request, that causes a service to crash. In case of a standalone VRM or BVMS with VRM installation this crash also opens the possibility to send further unauthenticated commands to the service. On some products the interface is only local accessible lowering the CVSS base score. For a list of modified CVSS scores, please see the official Bosch Advisory Appendix chapter Modified CVSS Scores for CVE-2021-23859"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-703",
"description": "CWE-703 Improper Check or Handling of Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-08T21:17:23",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
],
"source": {
"advisory": "BOSCH-SA-043434-BT",
"discovery": "EXTERNAL"
},
"title": "Denial of Service and Authentication Bypass Vulnerability in multiple Bosch products",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2021-12-08",
"ID": "CVE-2021-23859",
"STATE": "PUBLIC",
"TITLE": "Denial of Service and Authentication Bypass Vulnerability in multiple Bosch products"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "BVMS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "11.0",
"version_value": "11.0.0"
},
{
"version_affected": "\u003c",
"version_name": "10.0",
"version_value": "10.0.2"
},
{
"version_affected": "\u003c",
"version_name": "10.1",
"version_value": "10.1.1"
},
{
"version_affected": "\u003c=",
"version_value": "9.0.0"
}
]
}
},
{
"product_name": "DIVAR IP 7000 R2",
"version": {
"version_data": [
{
"configuration": "using vulnerable BVMS version",
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "DIVAR IP all-in-one 5000",
"version": {
"version_data": [
{
"configuration": "using vulnerable BVMS or VRM version",
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "DIVAR IP all-in-one 7000",
"version": {
"version_data": [
{
"configuration": "using vulnerable BVMS or VRM version",
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "VRM",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "4.0",
"version_value": "4.00.0070"
},
{
"version_affected": "\u003c=",
"version_name": "3.83",
"version_value": "3.83.0021"
},
{
"version_affected": "\u003c=",
"version_name": "3.82",
"version_value": "3.82.0057"
},
{
"version_affected": "\u003c=",
"version_value": "3.81"
}
]
}
},
{
"product_name": "VRM Exporter",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "2.1",
"version_value": "2.10.0008"
}
]
}
},
{
"product_name": "APE",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "3.8.x.x"
}
]
}
},
{
"product_name": "AEC",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "2.9.1.x"
}
]
}
},
{
"product_name": "BIS",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "4.9"
},
{
"version_affected": "\u003c=",
"version_value": "4.8"
},
{
"version_affected": "\u003c=",
"version_value": "4.7"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An unauthenticated attacker is able to send a special HTTP request, that causes a service to crash. In case of a standalone VRM or BVMS with VRM installation this crash also opens the possibility to send further unauthenticated commands to the service. On some products the interface is only local accessible lowering the CVSS base score. For a list of modified CVSS scores, please see the official Bosch Advisory Appendix chapter Modified CVSS Scores for CVE-2021-23859"
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-703 Improper Check or Handling of Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-043434-BT",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2021-23859",
"datePublished": "2021-12-08T21:17:23.528438Z",
"dateReserved": "2021-01-12T00:00:00",
"dateUpdated": "2024-09-16T19:45:43.543Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6957 (GCVE-0-2019-6957)
Vulnerability from nvd – Published: 2019-05-29 18:55 – Updated: 2024-09-16 16:38
VLAI?
Summary
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.396Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2019-04-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-29T18:55:20",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
],
"solutions": [
{
"lang": "en",
"value": "In cases where a software update is not possible, a reduction in the system\u2019s network exposure is advised. Internet-accessible installations should be firewalled, whilst additional steps like network isolation by VLAN, IP filtering features of the devices and other technologies should be used to decrease the exposure of vulnerable systems. In addition the firewall on the hosts shall be activated and set according to BVMS and BIS configuration manual. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems",
"x_generator": {
"engine": "Vulnogram 0.0.6"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-04-04T22:00:00.000Z",
"ID": "CVE-2019-6957",
"STATE": "PUBLIC",
"TITLE": "Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf",
"refsource": "CONFIRM",
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
}
]
},
"solution": [
{
"lang": "en",
"value": "In cases where a software update is not possible, a reduction in the system\u2019s network exposure is advised. Internet-accessible installations should be firewalled, whilst additional steps like network isolation by VLAN, IP filtering features of the devices and other technologies should be used to decrease the exposure of vulnerable systems. In addition the firewall on the hosts shall be activated and set according to BVMS and BIS configuration manual. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-6957",
"datePublished": "2019-05-29T18:55:20.387906Z",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-09-16T16:38:39.411Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6958 (GCVE-0-2019-6958)
Vulnerability from nvd – Published: 2019-05-29 18:47 – Updated: 2024-09-17 00:46
VLAI?
Summary
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.392Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2019-03-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \"CWE-284: Improper Access Control.\" This vulnerability, for example, allows a potential attacker to delete video or read video data."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-29T18:47:37",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
}
],
"solutions": [
{
"lang": "en",
"value": "The recommended approach is to update the software to a fixed version as soon as possible. Until a fixed software version is installed, the mitigation approaches firewalling, and IP filtering can be utilized. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Improper Access Control for Bosch Video Systems, PSIM and Access Control Systems",
"x_generator": {
"engine": "Vulnogram 0.0.6"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-03-04T23:00:00.000Z",
"ID": "CVE-2019-6958",
"STATE": "PUBLIC",
"TITLE": "Improper Access Control for Bosch Video Systems, PSIM and Access Control Systems"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \"CWE-284: Improper Access Control.\" This vulnerability, for example, allows a potential attacker to delete video or read video data."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf",
"refsource": "CONFIRM",
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
}
]
},
"solution": [
{
"lang": "en",
"value": "The recommended approach is to update the software to a fixed version as soon as possible. Until a fixed software version is installed, the mitigation approaches firewalling, and IP filtering can be utilized. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-6958",
"datePublished": "2019-05-29T18:47:37.354175Z",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-09-17T00:46:00.474Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",