CVE-2019-6958 (GCVE-0-2019-6958)
Vulnerability from cvelistv5 – Published: 2019-05-29 18:47 – Updated: 2024-09-17 00:46
VLAI?
Summary
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.392Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2019-03-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \"CWE-284: Improper Access Control.\" This vulnerability, for example, allows a potential attacker to delete video or read video data."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-29T18:47:37",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
}
],
"solutions": [
{
"lang": "en",
"value": "The recommended approach is to update the software to a fixed version as soon as possible. Until a fixed software version is installed, the mitigation approaches firewalling, and IP filtering can be utilized. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Improper Access Control for Bosch Video Systems, PSIM and Access Control Systems",
"x_generator": {
"engine": "Vulnogram 0.0.6"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-03-04T23:00:00.000Z",
"ID": "CVE-2019-6958",
"STATE": "PUBLIC",
"TITLE": "Improper Access Control for Bosch Video Systems, PSIM and Access Control Systems"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \"CWE-284: Improper Access Control.\" This vulnerability, for example, allows a potential attacker to delete video or read video data."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf",
"refsource": "CONFIRM",
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
}
]
},
"solution": [
{
"lang": "en",
"value": "The recommended approach is to update the software to a fixed version as soon as possible. Until a fixed software version is installed, the mitigation approaches firewalling, and IP filtering can be utilized. \n\nFor further informatation please check the published security advisory."
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-6958",
"datePublished": "2019-05-29T18:47:37.354175Z",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-09-17T00:46:00.474Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"3.0\", \"versionEndIncluding\": \"3.7\", \"matchCriteriaId\": \"3B5A626A-B735-4E0B-8BAC-0A26A02D6599\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:bosch:bosch_video_client:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.7.6.079\", \"matchCriteriaId\": \"EFBF448F-005B-48FF-B796-DBC8EAA35323\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"9.0\", \"matchCriteriaId\": \"0B9DD276-15C0-4942-8899-553F7C190320\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2.2\", \"versionEndIncluding\": \"4.4\", \"matchCriteriaId\": \"D92BA2E1-8554-4F13-938D-855BC33A59C9\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:bosch:building_integration_system:4.5:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8585CAE6-8A82-4338-A510-BB1798AC0BE3\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:bosch:building_integration_system:4.6:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"05B6AD6C-8FCC-473C-9D9A-91EA6C9A8E3E\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:bosch:building_integration_system:4.6.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8E219B63-2423-4D01-BDA9-8128B5E0DC24\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:bosch:configuration_manager:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.10\", \"matchCriteriaId\": \"4100A710-A356-4D54-BADE-F6C16947C3F0\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:bosch:video_sdk:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.32.0099\", \"matchCriteriaId\": \"F421BFB6-5448-4B86-AEB6-062682F56C10\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:bosch:dip_2000_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"0380.037\", \"matchCriteriaId\": \"EC039957-2F53-4080-AB7B-1E2AA4F81790\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:bosch:dip_2000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BC890021-B200-4743-AB51-03BDC9CB1351\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:bosch:dip_3000_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FAE1D3ED-FE23-4F3B-AE75-2FFBDEF5FDAF\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:bosch:dip_3000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"ABB194FD-9D50-4420-925F-48E4B2D0C2E7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:bosch:dip_5000_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"038.037\", \"matchCriteriaId\": \"E0062D5B-DF47-47AB-A6E7-B00BEA2FBA1E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:bosch:dip_5000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7EFAEE79-2B7C-4F74-B663-F49F2606AF41\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:bosch:dip_7000_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7731276E-38B9-4B01-B4A3-092A49150B9A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:bosch:dip_7000:gen1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C8FDECC6-46D7-4EAF-9CBC-06D2F18AADA5\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:bosch:dip_7000:gen2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"ED2FF548-939C-4F10-A3E7-02DF342A35B0\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.8.5:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DA449D4D-8AF0-4792-A9CA-8195A4E0082B\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DE6EFC6A-351D-4571-A1F7-1E6AC0B77B22\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A6B97D59-8692-449F-BA59-C2C2F3E0FDDB\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.3:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A3C2E4AA-B871-4B0B-8BD0-8D5440BE8144\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:bosch:access_easy_controller:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"50324AEF-BF89-4AAC-B467-FCF87796AB01\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \\\"CWE-284: Improper Access Control.\\\" This vulnerability, for example, allows a potential attacker to delete video or read video data.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad de seguridad encontrada recientemente impacta a todas las versiones 9.0 y siguientes de Bosch Video Management System (BVMS), DIVAR IP 2000, 3000, 5000 y 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). El puerto de red RCP+ permite acceso sin autenticaci\\u00f3n. La adici\\u00f3n de la funci\\u00f3n authentication a la biblioteca correspondiente soluciona el problema. El problema es clasificado como \\\"CWE-284: Improper Access Control\\\". Esta vulnerabilidad, por ejemplo, permite a un potencial atacante eliminar un v\\u00eddeo o leer datos de un v\\u00eddeo.\"}]",
"id": "CVE-2019-6958",
"lastModified": "2024-11-21T04:47:18.280",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\", \"baseScore\": 9.1, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.2}], \"cvssMetricV30\": [{\"source\": \"cve@mitre.org\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:P/A:N\", \"baseScore\": 6.4, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 4.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2019-05-29T19:29:00.703",
"references": "[{\"url\": \"https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf\", \"source\": \"cve@mitre.org\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}, {\"url\": \"https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-6958\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2019-05-29T19:29:00.703\",\"lastModified\":\"2024-11-21T04:47:18.280\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \\\"CWE-284: Improper Access Control.\\\" This vulnerability, for example, allows a potential attacker to delete video or read video data.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de seguridad encontrada recientemente impacta a todas las versiones 9.0 y siguientes de Bosch Video Management System (BVMS), DIVAR IP 2000, 3000, 5000 y 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). El puerto de red RCP+ permite acceso sin autenticaci\u00f3n. La adici\u00f3n de la funci\u00f3n authentication a la biblioteca correspondiente soluciona el problema. El problema es clasificado como \\\"CWE-284: Improper Access Control\\\". Esta vulnerabilidad, por ejemplo, permite a un potencial atacante eliminar un v\u00eddeo o leer datos de un v\u00eddeo.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2}],\"cvssMetricV30\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:N\",\"baseScore\":6.4,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.0\",\"versionEndIncluding\":\"3.7\",\"matchCriteriaId\":\"3B5A626A-B735-4E0B-8BAC-0A26A02D6599\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:bosch_video_client:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.7.6.079\",\"matchCriteriaId\":\"EFBF448F-005B-48FF-B796-DBC8EAA35323\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"9.0\",\"matchCriteriaId\":\"0B9DD276-15C0-4942-8899-553F7C190320\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.2\",\"versionEndIncluding\":\"4.4\",\"matchCriteriaId\":\"D92BA2E1-8554-4F13-938D-855BC33A59C9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:building_integration_system:4.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8585CAE6-8A82-4338-A510-BB1798AC0BE3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:building_integration_system:4.6:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"05B6AD6C-8FCC-473C-9D9A-91EA6C9A8E3E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:building_integration_system:4.6.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8E219B63-2423-4D01-BDA9-8128B5E0DC24\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:configuration_manager:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.10\",\"matchCriteriaId\":\"4100A710-A356-4D54-BADE-F6C16947C3F0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:video_sdk:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.32.0099\",\"matchCriteriaId\":\"F421BFB6-5448-4B86-AEB6-062682F56C10\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:dip_2000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"0380.037\",\"matchCriteriaId\":\"EC039957-2F53-4080-AB7B-1E2AA4F81790\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:dip_2000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BC890021-B200-4743-AB51-03BDC9CB1351\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:dip_3000_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FAE1D3ED-FE23-4F3B-AE75-2FFBDEF5FDAF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:dip_3000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ABB194FD-9D50-4420-925F-48E4B2D0C2E7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:dip_5000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"038.037\",\"matchCriteriaId\":\"E0062D5B-DF47-47AB-A6E7-B00BEA2FBA1E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:dip_5000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7EFAEE79-2B7C-4F74-B663-F49F2606AF41\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:dip_7000_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7731276E-38B9-4B01-B4A3-092A49150B9A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:dip_7000:gen1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C8FDECC6-46D7-4EAF-9CBC-06D2F18AADA5\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:dip_7000:gen2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ED2FF548-939C-4F10-A3E7-02DF342A35B0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.8.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DA449D4D-8AF0-4792-A9CA-8195A4E0082B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DE6EFC6A-351D-4571-A1F7-1E6AC0B77B22\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A6B97D59-8692-449F-BA59-C2C2F3E0FDDB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A3C2E4AA-B871-4B0B-8BD0-8D5440BE8144\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:access_easy_controller:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"50324AEF-BF89-4AAC-B467-FCF87796AB01\"}]}]}],\"references\":[{\"url\":\"https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…