Search criteria
126 vulnerabilities found for control_for_wago_touch_panels_600_sl by codesys
FKIE_CVE-2023-6357
Vulnerability from fkie_nvd - Published: 2023-12-05 15:15 - Updated: 2024-11-21 08:43
Severity ?
Summary
A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://https://cert.vde.com/en/advisories/VDE-2023-066 | Broken Link | |
| nvd@nist.gov | https://cert.vde.com/en/advisories/VDE-2023-066 | Mitigation, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://https://cert.vde.com/en/advisories/VDE-2023-066 | Broken Link |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DEFEF3B4-03F2-4E09-A8F2-02A0604CB8BF",
"versionEndExcluding": "4.11.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B2DB55B1-CAFE-435B-8776-DB4D33ED9C98",
"versionEndExcluding": "4.11.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7D492DB3-94BA-4F14-8119-1610AB4F95EE",
"versionEndExcluding": "4.11.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "97D00DF9-EBF1-4DEC-8A49-694871643B9F",
"versionEndExcluding": "4.11.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D6F207B6-5906-4B39-A5B4-A07F6D5A9BB9",
"versionEndExcluding": "4.11.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7791D9E4-CEC3-4658-8E2C-8F08882CE4F4",
"versionEndExcluding": "4.11.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9CADE021-8D58-4BC5-BA60-A16FE24FBA73",
"versionEndExcluding": "4.11.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B3948946-E7B8-4D7E-8D1D-80B9E0DB47AF",
"versionEndExcluding": "4.11.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7C9DF443-E965-4480-B76E-4A25CF2E714F",
"versionEndExcluding": "4.11.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F5FCD76E-A3F5-4E02-AD3F-B2BDE708A651",
"versionEndExcluding": "4.11.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "162DB2B8-3426-43F7-848A-BE542C24619C",
"versionEndExcluding": "3.5.19.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
},
{
"lang": "es",
"value": "Un atacante remoto con pocos privilegios podr\u00eda aprovechar la vulnerabilidad e inyectar comandos adicionales del sistema a trav\u00e9s de librer\u00edas del sistema de archivos que podr\u00edan darle al atacante el control total del dispositivo."
}
],
"id": "CVE-2023-6357",
"lastModified": "2024-11-21T08:43:41.900",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "info@cert.vde.com",
"type": "Primary"
}
]
},
"published": "2023-12-05T15:15:08.983",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Broken Link"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
},
{
"source": "nvd@nist.gov",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-066"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "info@cert.vde.com",
"type": "Primary"
}
]
}
FKIE_CVE-2022-4046
Vulnerability from fkie_nvd - Published: 2023-08-03 13:15 - Updated: 2024-11-21 07:34
Severity ?
Summary
In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-025/ | Mitigation, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-025/ | Mitigation, Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2390BDA5-FC7C-43F2-A6D0-098DE49E8092",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "07DC0FD5-57BB-41CD-9FFD-36FEC5573BFB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BE2276F0-8EF2-4CEA-9A75-010D31F8D76C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DB41ACE5-0064-4BBC-AEF7-2A89D21EEA83",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D23780DF-5CF3-4D88-83A4-D5D0E6BF7274",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0CAF552D-E704-4979-9335-6290F11D6EA9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "31A0FF97-A6E5-4339-B68A-E1F76A24D50E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BC1C54A7-686C-433C-91B0-B84720ABFC81",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B1B0A7F9-9F70-4217-AF38-14E9F9F7CDDB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D2102923-8711-4D2C-BF3E-870AC1D8F2AA",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "98918E65-854F-4719-8419-79578C5F9EAD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "07750392-D8FF-413D-82F9-55B9F2F12B55",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EE76A4D8-070C-45D7-AF3B-12FFD6BD73E3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "23B980AB-A690-43C0-A117-929C4AD7A2DF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device."
}
],
"id": "CVE-2022-4046",
"lastModified": "2024-11-21T07:34:30.347",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "info@cert.vde.com",
"type": "Primary"
}
]
},
"published": "2023-08-03T13:15:09.627",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-025/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-025/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "info@cert.vde.com",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37551
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2024-11-21 08:11
Severity ?
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller."
},
{
"lang": "es",
"value": "En m\u00faltiples productos Codesys en m\u00faltiples versiones , despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, las solicitudes de comunicaci\u00f3n de red especialmente dise\u00f1adas pueden utilizar el componente CmpApp para descargar archivos con cualquier extensi\u00f3n de archivo al controlador. A diferencia de la descarga de archivos normal a trav\u00e9s de CmpFileTransfer, aqu\u00ed no se realiza ning\u00fan filtrado de determinados tipos de archivos. Como resultado, la integridad del sistema de ejecuci\u00f3n de control CODESYS puede verse comprometida por los archivos cargados en el controlador."
}
],
"id": "CVE-2023-37551",
"lastModified": "2024-11-21T08:11:55.417",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-08-03T12:15:10.257",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-552"
}
],
"source": "info@cert.vde.com",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37556
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2024-11-21 08:11
Severity ?
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37555.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and CVE-2023-37555.\n\n"
},
{
"lang": "es",
"value": "En varias versiones de varios productos Codesys, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, solicitudes de comunicaci\u00f3n de red espec\u00edficas dise\u00f1adas con contenido inconsistente pueden hacer que el componente CmpAppBP lea internamente desde una direcci\u00f3n no v\u00e1lida, lo que podr\u00eda provocar una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente a CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 y CVE-2023-37555."
}
],
"id": "CVE-2023-37556",
"lastModified": "2024-11-21T08:11:56.203",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Primary"
}
]
},
"published": "2023-08-03T12:15:10.707",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37559
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2024-11-21 08:11
Severity ?
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558"
},
{
"lang": "es",
"value": "Despu\u00e9s de una autenticaci\u00f3n exitosa como usuario en m\u00faltiples productos Codesys en m\u00faltiples versiones, solicitudes de comunicaci\u00f3n de red espec\u00edficas dise\u00f1adas con contenido inconsistente pueden hacer que el componente CmpAppForce lea internamente desde una direcci\u00f3n no v\u00e1lida, lo que podr\u00eda conducir a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente a CVE-2023-37558"
}
],
"id": "CVE-2023-37559",
"lastModified": "2024-11-21T08:11:56.653",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Primary"
}
]
},
"published": "2023-08-03T12:15:10.977",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37552
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2024-11-21 08:11
Severity ?
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
},
{
"lang": "es",
"value": "En varias versiones de varios productos Codesys, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, solicitudes de comunicaci\u00f3n de red espec\u00edficas dise\u00f1adas con contenido inconsistente pueden hacer que el componente CmpAppBP lea internamente desde una direcci\u00f3n no v\u00e1lida, lo que podr\u00eda provocar una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente a CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 y CVE-2023-37556."
}
],
"id": "CVE-2023-37552",
"lastModified": "2024-11-21T08:11:55.577",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-08-03T12:15:10.353",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37555
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2024-11-21 08:11
Severity ?
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37556.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and\u00a0CVE-2023-37556.\n\n"
},
{
"lang": "es",
"value": "En m\u00faltiples versiones de m\u00faltiples productos de Codesys, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, las solicitudes de comunicaci\u00f3n de red espec\u00edficas con contenido inconsistente pueden causar que el componente CmpAppBP lea internamente desde una direcci\u00f3n inv\u00e1lida, potencialmente llevando a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente de CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 y CVE-2023-37556."
}
],
"id": "CVE-2023-37555",
"lastModified": "2024-11-21T08:11:56.037",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Primary"
}
]
},
"published": "2023-08-03T12:15:10.620",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37549
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2024-11-21 08:11
Severity ?
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550\n\n"
},
{
"lang": "es",
"value": "En m\u00faltiples productos de Codesys en m\u00faltiples versiones, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, solicitudes espec\u00edficas de comunicaci\u00f3n de red con contenido inconsistente pueden causar que el componente CmpApp lea internamente desde una direcci\u00f3n inv\u00e1lida, potencialmente llevando a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente de CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 y CVE-2023-37550."
}
],
"id": "CVE-2023-37549",
"lastModified": "2024-11-21T08:11:55.087",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Primary"
}
]
},
"published": "2023-08-03T12:15:10.083",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37550
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2024-11-21 08:11
Severity ?
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.\n\n"
},
{
"lang": "es",
"value": "En muchos productos Codesys en m\u00faltiples versiones, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, solicitudes de comunicaci\u00f3n de red espec\u00edficas dise\u00f1adas con contenido inconsistente pueden hacer que el componente CmpApp lea internamente desde una direcci\u00f3n no v\u00e1lida, lo que podr\u00eda conducir a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente a CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 y CVE-2023-37549."
}
],
"id": "CVE-2023-37550",
"lastModified": "2024-11-21T08:11:55.243",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Primary"
}
]
},
"published": "2023-08-03T12:15:10.170",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37554
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2024-11-21 08:11
Severity ?
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 and CVE-2023-37556.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553, CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
},
{
"lang": "es",
"value": "En m\u00faltiples versiones de m\u00faltiples productos de Codesys, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, las solicitudes de comunicaci\u00f3n de red espec\u00edficas con contenido inconsistente pueden causar que el componente CmpAppBP lea internamente desde una direcci\u00f3n inv\u00e1lida, potencialmente conduciendo a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente de CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 y CVE-2023-37556."
}
],
"id": "CVE-2023-37554",
"lastModified": "2024-11-21T08:11:55.887",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Primary"
}
]
},
"published": "2023-08-03T12:15:10.530",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37553
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2024-11-21 08:11
Severity ?
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
},
{
"lang": "es",
"value": "En m\u00faltiples versiones de m\u00faltiples productos de Codesys, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, las solicitudes de comunicaci\u00f3n de red con contenido inconsistente pueden causar que el componente CmpAppBP lea internamente desde una direcci\u00f3n inv\u00e1lida, potencialmente llevando a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente de CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 y CVE-2023-37556."
}
],
"id": "CVE-2023-37553",
"lastModified": "2024-11-21T08:11:55.730",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Primary"
}
]
},
"published": "2023-08-03T12:15:10.443",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37557
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2024-11-21 08:11
Severity ?
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition."
},
{
"lang": "es",
"value": "Despu\u00e9s de una autenticaci\u00f3n exitosa como usuario en m\u00faltiples productos Codesys en m\u00faltiples versiones, solicitudes de comunicaci\u00f3n remota dise\u00f1adas espec\u00edficamente pueden hacer que el componente CmpAppBP sobrescriba un desbordamiento de b\u00fafer, lo que puede conducir a una condici\u00f3n de denegaci\u00f3n de servicio."
}
],
"id": "CVE-2023-37557",
"lastModified": "2024-11-21T08:11:56.350",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Primary"
}
]
},
"published": "2023-08-03T12:15:10.797",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "info@cert.vde.com",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37558
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2024-11-21 08:11
Severity ?
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559"
},
{
"lang": "es",
"value": "Despu\u00e9s de una autenticaci\u00f3n exitosa como usuario en m\u00faltiples productos Codesys en m\u00faltiples versiones, solicitudes de comunicaci\u00f3n de red espec\u00edficas dise\u00f1adas con contenido inconsistente pueden hacer que el componente CmpAppForce lea internamente desde una direcci\u00f3n no v\u00e1lida, lo que podr\u00eda conducir a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente a CVE-2023-37559"
}
],
"id": "CVE-2023-37558",
"lastModified": "2024-11-21T08:11:56.503",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Primary"
}
]
},
"published": "2023-08-03T12:15:10.890",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37546
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2024-11-21 08:11
Severity ?
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\n\n"
}
],
"id": "CVE-2023-37546",
"lastModified": "2024-11-21T08:11:54.597",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Primary"
}
]
},
"published": "2023-08-03T12:15:09.790",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37548
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2024-11-21 08:11
Severity ?
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550\n\n"
}
],
"id": "CVE-2023-37548",
"lastModified": "2024-11-21T08:11:54.897",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Primary"
}
]
},
"published": "2023-08-03T12:15:09.997",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37547
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2024-11-21 08:11
Severity ?
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\n\n"
}
],
"id": "CVE-2023-37547",
"lastModified": "2024-11-21T08:11:54.743",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Primary"
}
]
},
"published": "2023-08-03T12:15:09.910",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37545
Vulnerability from fkie_nvd - Published: 2023-08-03 11:15 - Updated: 2024-11-21 08:11
Severity ?
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550\n\n"
}
],
"id": "CVE-2023-37545",
"lastModified": "2024-11-21T08:11:54.430",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Primary"
}
]
},
"published": "2023-08-03T11:15:09.837",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2023-6357 (GCVE-0-2023-6357)
Vulnerability from cvelistv5 – Published: 2023-12-05 14:29 – Updated: 2024-08-02 08:28
VLAI?
Summary
A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device.
Severity ?
8.8 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < 4.11.0.0
(semver)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
Credits
Chuya Hayakawa of 00One, Inc.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:28:21.783Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit for Linux or QNX",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.50",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Chuya Hayakawa of 00One, Inc."
}
],
"datePublic": "2023-12-05T14:25:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
}
],
"value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-05T14:29:25.649Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
}
],
"source": {
"advisory": "VDE-2023-066",
"defect": [
"CERT@VDE#64623"
],
"discovery": "UNKNOWN"
},
"title": "OS Command Injection in multiple CODESYS products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-6357",
"datePublished": "2023-12-05T14:29:25.649Z",
"dateReserved": "2023-11-28T07:20:59.774Z",
"dateUpdated": "2024-08-02T08:28:21.783Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-4046 (GCVE-0-2022-4046)
Vulnerability from cvelistv5 – Published: 2023-08-03 12:39 – Updated: 2024-10-22 19:44
VLAI?
Summary
In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.
Severity ?
8.8 (High)
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
all
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:27:54.486Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-025/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-4046",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-22T19:43:34.142141Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-22T19:44:02.247Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device."
}
],
"value": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T12:39:44.002Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-025/"
}
],
"source": {
"defect": [
"CERT@VDE#64299"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper memory restrictions fro CODESYS Control",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-4046",
"datePublished": "2023-08-03T12:39:44.002Z",
"dateReserved": "2022-11-17T07:07:09.714Z",
"dateUpdated": "2024-10-22T19:44:02.247Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37559 (GCVE-0-2023-37559)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:06 – Updated: 2024-10-11 18:09
VLAI?
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.700Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37559",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:07:28.102576Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:09:05.823Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558"
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:56.079Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Validation of Consistency within Input in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37559",
"datePublished": "2023-08-03T11:06:56.079Z",
"dateReserved": "2023-07-07T07:39:19.122Z",
"dateUpdated": "2024-10-11T18:09:05.823Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37558 (GCVE-0-2023-37558)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:06 – Updated: 2024-10-11 18:09
VLAI?
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.767Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37558",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:07:13.616622Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:09:20.780Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559"
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:36.112Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Validation of Consistency within Input in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37558",
"datePublished": "2023-08-03T11:06:36.112Z",
"dateReserved": "2023-07-07T07:39:19.121Z",
"dateUpdated": "2024-10-11T18:09:20.780Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37557 (GCVE-0-2023-37557)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:06 – Updated: 2024-10-09 20:52
VLAI?
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition.
Severity ?
6.5 (Medium)
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.379Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37557",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:48:56.664856Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:16.817Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition."
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:17.884Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Heap-based Buffer Overflow in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37557",
"datePublished": "2023-08-03T11:06:17.884Z",
"dateReserved": "2023-07-07T07:39:19.121Z",
"dateUpdated": "2024-10-09T20:52:16.817Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37556 (GCVE-0-2023-37556)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:05 – Updated: 2024-10-09 20:52
VLAI?
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37555.
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.852Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37556",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:49:03.697246Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:36.722Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37553,\u0026nbsp;CVE-2023-37554 and CVE-2023-37555.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and CVE-2023-37555.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:05:52.986Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37556",
"datePublished": "2023-08-03T11:05:52.986Z",
"dateReserved": "2023-07-07T07:39:19.120Z",
"dateUpdated": "2024-10-09T20:52:36.722Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37555 (GCVE-0-2023-37555)
Vulnerability from cvelistv5 – Published: 2023-08-03 11:05 – Updated: 2024-10-09 20:52
VLAI?
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37556.
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.445Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37555",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:49:10.954455Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:51.974Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37553,\u0026nbsp;CVE-2023-37554 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:05:33.660Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37555",
"datePublished": "2023-08-03T11:05:33.660Z",
"dateReserved": "2023-07-07T07:39:19.120Z",
"dateUpdated": "2024-10-09T20:52:51.974Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-6357 (GCVE-0-2023-6357)
Vulnerability from nvd – Published: 2023-12-05 14:29 – Updated: 2024-08-02 08:28
VLAI?
Summary
A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device.
Severity ?
8.8 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < 4.11.0.0
(semver)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
Credits
Chuya Hayakawa of 00One, Inc.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:28:21.783Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit for Linux or QNX",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.50",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Chuya Hayakawa of 00One, Inc."
}
],
"datePublic": "2023-12-05T14:25:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
}
],
"value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-05T14:29:25.649Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
}
],
"source": {
"advisory": "VDE-2023-066",
"defect": [
"CERT@VDE#64623"
],
"discovery": "UNKNOWN"
},
"title": "OS Command Injection in multiple CODESYS products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-6357",
"datePublished": "2023-12-05T14:29:25.649Z",
"dateReserved": "2023-11-28T07:20:59.774Z",
"dateUpdated": "2024-08-02T08:28:21.783Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-4046 (GCVE-0-2022-4046)
Vulnerability from nvd – Published: 2023-08-03 12:39 – Updated: 2024-10-22 19:44
VLAI?
Summary
In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.
Severity ?
8.8 (High)
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
all
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:27:54.486Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-025/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-4046",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-22T19:43:34.142141Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-22T19:44:02.247Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device."
}
],
"value": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T12:39:44.002Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-025/"
}
],
"source": {
"defect": [
"CERT@VDE#64299"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper memory restrictions fro CODESYS Control",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-4046",
"datePublished": "2023-08-03T12:39:44.002Z",
"dateReserved": "2022-11-17T07:07:09.714Z",
"dateUpdated": "2024-10-22T19:44:02.247Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37559 (GCVE-0-2023-37559)
Vulnerability from nvd – Published: 2023-08-03 11:06 – Updated: 2024-10-11 18:09
VLAI?
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.700Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37559",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:07:28.102576Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:09:05.823Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558"
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:56.079Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Validation of Consistency within Input in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37559",
"datePublished": "2023-08-03T11:06:56.079Z",
"dateReserved": "2023-07-07T07:39:19.122Z",
"dateUpdated": "2024-10-11T18:09:05.823Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37558 (GCVE-0-2023-37558)
Vulnerability from nvd – Published: 2023-08-03 11:06 – Updated: 2024-10-11 18:09
VLAI?
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.767Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37558",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:07:13.616622Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:09:20.780Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559"
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:36.112Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Validation of Consistency within Input in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37558",
"datePublished": "2023-08-03T11:06:36.112Z",
"dateReserved": "2023-07-07T07:39:19.121Z",
"dateUpdated": "2024-10-11T18:09:20.780Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37557 (GCVE-0-2023-37557)
Vulnerability from nvd – Published: 2023-08-03 11:06 – Updated: 2024-10-09 20:52
VLAI?
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition.
Severity ?
6.5 (Medium)
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.379Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37557",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:48:56.664856Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:16.817Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition."
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:17.884Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Heap-based Buffer Overflow in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37557",
"datePublished": "2023-08-03T11:06:17.884Z",
"dateReserved": "2023-07-07T07:39:19.121Z",
"dateUpdated": "2024-10-09T20:52:16.817Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37556 (GCVE-0-2023-37556)
Vulnerability from nvd – Published: 2023-08-03 11:05 – Updated: 2024-10-09 20:52
VLAI?
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37555.
Severity ?
6.5 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
||
|
|
||||
Credits
Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.852Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37556",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:49:03.697246Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:36.722Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37553,\u0026nbsp;CVE-2023-37554 and CVE-2023-37555.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and CVE-2023-37555.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:05:52.986Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37556",
"datePublished": "2023-08-03T11:05:52.986Z",
"dateReserved": "2023-07-07T07:39:19.120Z",
"dateUpdated": "2024-10-09T20:52:36.722Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}