cve-2023-6357
Vulnerability from cvelistv5
Published
2023-12-05 14:29
Modified
2024-08-02 08:28
Severity ?
EPSS score ?
Summary
OS Command Injection in multiple CODESYS products
References
▼ | URL | Tags | |
---|---|---|---|
nvd@nist.gov | https://cert.vde.com/en/advisories/VDE-2023-066 | Mitigation, Third Party Advisory | |
info@cert.vde.com | https://https://cert.vde.com/en/advisories/VDE-2023-066 | Broken Link |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T08:28:21.783Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://https://cert.vde.com/en/advisories/VDE-2023-066" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [ { "lessThan": "4.11.0.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "4.11.0.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "4.11.0.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS Control for Linux ARM SL", "vendor": "CODESYS", "versions": [ { "lessThan": "4.11.0.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [ { "lessThan": "4.11.0.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "4.11.0.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "4.11.0.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS Control for PLCnext SL", "vendor": "CODESYS", "versions": [ { "lessThan": "4.11.0.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [ { "lessThan": "4.11.0.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "4.11.0.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS Runtime Toolkit for Linux or QNX", "vendor": "CODESYS", "versions": [ { "lessThan": "3.5.19.50", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Chuya Hayakawa of 00One, Inc." } ], "datePublic": "2023-12-05T14:25:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device." } ], "value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-05T14:29:25.649Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://https://cert.vde.com/en/advisories/VDE-2023-066" } ], "source": { "advisory": "VDE-2023-066", "defect": [ "CERT@VDE#64623" ], "discovery": "UNKNOWN" }, "title": "OS Command Injection in multiple CODESYS products", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2023-6357", "datePublished": "2023-12-05T14:29:25.649Z", "dateReserved": "2023-11-28T07:20:59.774Z", "dateUpdated": "2024-08-02T08:28:21.783Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-6357\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2023-12-05T15:15:08.983\",\"lastModified\":\"2023-12-11T20:49:14.117\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device.\"},{\"lang\":\"es\",\"value\":\"Un atacante remoto con pocos privilegios podr\u00eda aprovechar la vulnerabilidad e inyectar comandos adicionales del sistema a trav\u00e9s de librer\u00edas del sistema de archivos que podr\u00edan darle al atacante el control total del dispositivo.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.11.0.0\",\"matchCriteriaId\":\"DEFEF3B4-03F2-4E09-A8F2-02A0604CB8BF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_empc-a\\\\/imx6:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.11.0.0\",\"matchCriteriaId\":\"B2DB55B1-CAFE-435B-8776-DB4D33ED9C98\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.11.0.0\",\"matchCriteriaId\":\"7D492DB3-94BA-4F14-8119-1610AB4F95EE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.11.0.0\",\"matchCriteriaId\":\"97D00DF9-EBF1-4DEC-8A49-694871643B9F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.11.0.0\",\"matchCriteriaId\":\"D6F207B6-5906-4B39-A5B4-A07F6D5A9BB9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.11.0.0\",\"matchCriteriaId\":\"7791D9E4-CEC3-4658-8E2C-8F08882CE4F4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.11.0.0\",\"matchCriteriaId\":\"9CADE021-8D58-4BC5-BA60-A16FE24FBA73\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.11.0.0\",\"matchCriteriaId\":\"B3948946-E7B8-4D7E-8D1D-80B9E0DB47AF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.11.0.0\",\"matchCriteriaId\":\"7C9DF443-E965-4480-B76E-4A25CF2E714F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.11.0.0\",\"matchCriteriaId\":\"F5FCD76E-A3F5-4E02-AD3F-B2BDE708A651\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.19.50\",\"matchCriteriaId\":\"162DB2B8-3426-43F7-848A-BE542C24619C\"}]}]}],\"references\":[{\"url\":\"https://cert.vde.com/en/advisories/VDE-2023-066\",\"source\":\"nvd@nist.gov\",\"tags\":[\"Mitigation\",\"Third Party Advisory\"]},{\"url\":\"https://https://cert.vde.com/en/advisories/VDE-2023-066\",\"source\":\"info@cert.vde.com\",\"tags\":[\"Broken Link\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.