cve-2022-4046
Vulnerability from cvelistv5
Published
2023-08-03 12:39
Modified
2024-10-22 19:44
Severity ?
EPSS score ?
Summary
CODESYS: Improper memory restrictions fro CODESYS Control
References
▼ | URL | Tags | |
---|---|---|---|
info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-025/ | Mitigation, Third Party Advisory |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T01:27:54.486Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert.vde.com/en/advisories/VDE-2023-025/" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-4046", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-22T19:43:34.142141Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-22T19:44:02.247Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "affected", "product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "affected", "product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "affected", "product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "affected", "product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "affected", "product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "affected", "product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "affected", "product": "CODESYS Control for PLCnext SL", "vendor": "CODESYS", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "affected", "product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "affected", "product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "affected", "product": "CODESYS Control RTE (for Beckhoff CX) SL", "vendor": "CODESYS", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "affected", "product": "CODESYS Control RTE (SL)", "vendor": "CODESYS", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "affected", "product": "CODESYS Control Runtime System Toolkit", "vendor": "CODESYS", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "affected", "product": "CODESYS Control Win (SL)", "vendor": "CODESYS", "versions": [ { "status": "affected", "version": "all" } ] }, { "defaultStatus": "affected", "product": "CODESYS HMI (SL)", "vendor": "CODESYS", "versions": [ { "status": "affected", "version": "all" } ] } ], "datePublic": "2023-08-03T10:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device." } ], "value": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-03T12:39:44.002Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2023-025/" } ], "source": { "defect": [ "CERT@VDE#64299" ], "discovery": "EXTERNAL" }, "title": "CODESYS: Improper memory restrictions fro CODESYS Control", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2022-4046", "datePublished": "2023-08-03T12:39:44.002Z", "dateReserved": "2022-11-17T07:07:09.714Z", "dateUpdated": "2024-10-22T19:44:02.247Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-4046\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2023-08-03T13:15:09.627\",\"lastModified\":\"2023-08-08T15:54:22.383\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2390BDA5-FC7C-43F2-A6D0-098DE49E8092\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_empc-a\\\\/imx6_sl:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07DC0FD5-57BB-41CD-9FFD-36FEC5573BFB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BE2276F0-8EF2-4CEA-9A75-010D31F8D76C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB41ACE5-0064-4BBC-AEF7-2A89D21EEA83\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D23780DF-5CF3-4D88-83A4-D5D0E6BF7274\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0CAF552D-E704-4979-9335-6290F11D6EA9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"31A0FF97-A6E5-4339-B68A-E1F76A24D50E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BC1C54A7-686C-433C-91B0-B84720ABFC81\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B1B0A7F9-9F70-4217-AF38-14E9F9F7CDDB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D2102923-8711-4D2C-BF3E-870AC1D8F2AA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_rte_sl_\\\\(for_beckhoff_cx\\\\):*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"98918E65-854F-4719-8419-79578C5F9EAD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07750392-D8FF-413D-82F9-55B9F2F12B55\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EE76A4D8-070C-45D7-AF3B-12FFD6BD73E3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"23B980AB-A690-43C0-A117-929C4AD7A2DF\"}]}]}],\"references\":[{\"url\":\"https://cert.vde.com/en/advisories/VDE-2023-025/\",\"source\":\"info@cert.vde.com\",\"tags\":[\"Mitigation\",\"Third Party Advisory\"]}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.