Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CERTFR-2023-AVI-0297
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneImpacted products
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Modicon M580 NOC Control (BMENOC0321) versions antérieures à 1.8 | ||
| Schneider Electric | N/A | PacDrive 3 Controllers LMC | ||
| Schneider Electric | N/A | Easergy Builder installer versions antérieures à V1.7.24 | ||
| Schneider Electric | N/A | Modicon Controller LMC058 | ||
| Schneider Electric | N/A | Modicon Controller M258 | ||
| Schneider Electric | N/A | Eco/Pro/Pro2 | ||
| Schneider Electric | N/A | Modicon M580 versions antérieures à SV4.10 | ||
| Schneider Electric | Modicon M340 | Modicon Modicon M340 CPU (part numbers BMXP34*) versions antérieures à SV3.51 | ||
| Schneider Electric | N/A | Modicon Controller M262 | ||
| Schneider Electric | N/A | PacDrive Controller LMC078 | ||
| Schneider Electric | N/A | Modicon Controller M241 | ||
| Schneider Electric | N/A | InsightHome, InsightFacility et Conext Gateway versions antérieures à 1.17 Build 079 | ||
| Schneider Electric | N/A | EcoStruxure Control Expert versions antérieures à V15.3 | ||
| Schneider Electric | N/A | Schneider Electric Easy UPS Online versions antérieures à 2.6-GS | ||
| Schneider Electric | N/A | Modicon Controller M218 | ||
| Schneider Electric | N/A | HMISCU Controller | ||
| Schneider Electric | N/A | Modicon Controller M251 | ||
| Schneider Electric | N/A | Easy Harmony ET6 (HMIET Series) et Easy Harmony GXU (HMIGXU Series) avec Vijeo Designer Basic versions antérieures à V1.2.1 Hotfix 4 | ||
| Schneider Electric | N/A | APC Easy UPS Online Monitoring versions antérieures à 2.6-GA | ||
| Schneider Electric | N/A | Modicon M580 Ethernet Communication Modules (BMENOC0301 et BMENOC0311) versions antérieures à SV2.21 | ||
| Schneider Electric | Modicon M340 | Modicon M340 CPU versions antérieures à SV3.51 |
References
| Title | Publication Time | Tags | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Modicon M580 NOC Control (BMENOC0321) versions ant\u00e9rieures \u00e0 1.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PacDrive 3 Controllers LMC",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easergy Builder installer versions ant\u00e9rieures \u00e0 V1.7.24",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller LMC058",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller M258",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Eco/Pro/Pro2",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 versions ant\u00e9rieures \u00e0 SV4.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Modicon M340 CPU (part numbers BMXP34*) versions ant\u00e9rieures \u00e0 SV3.51",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller M262",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PacDrive Controller LMC078",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller M241",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "InsightHome, InsightFacility et Conext Gateway versions ant\u00e9rieures \u00e0 1.17 Build 079",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Control Expert versions ant\u00e9rieures \u00e0 V15.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric Easy UPS Online versions ant\u00e9rieures \u00e0 2.6-GS",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller M218",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "HMISCU Controller",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller M251",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easy Harmony ET6 (HMIET Series) et Easy Harmony GXU (HMIGXU Series) avec Vijeo Designer Basic versions ant\u00e9rieures \u00e0 V1.2.1 Hotfix 4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "APC Easy UPS Online Monitoring versions ant\u00e9rieures \u00e0 2.6-GA",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 Ethernet Communication Modules (BMENOC0301 et BMENOC0311) versions ant\u00e9rieures \u00e0 SV2.21",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 CPU versions ant\u00e9rieures \u00e0 SV3.51",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-29413",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29413"
},
{
"name": "CVE-2023-29410",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29410"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2022-4046",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4046"
},
{
"name": "CVE-2023-29412",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29412"
},
{
"name": "CVE-2023-27976",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27976"
},
{
"name": "CVE-2022-34755",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34755"
},
{
"name": "CVE-2023-25620",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-25620"
},
{
"name": "CVE-2023-1548",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1548"
},
{
"name": "CVE-2023-29411",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29411"
},
{
"name": "CVE-2023-28355",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28355"
},
{
"name": "CVE-2023-25619",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-25619"
},
{
"name": "CVE-2022-45788",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-45788"
},
{
"name": "CVE-2022-4224",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4224"
},
{
"name": "CVE-2021-29241",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29241"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0297",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-04-11T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2022-011-06 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-011-06_CODESYSV3_Runtime_Development_System_and_Gateway_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-05 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-06 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-06.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-04 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-02 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-02.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-03 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-03.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-01 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-01.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-010-05 du 10 janvier 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-05_Modicon_Controllers_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-313-05 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_BadAlloc_Vulnerabilities_Security_Notification.pdf"
}
]
}
CVE-2020-28895 (GCVE-0-2020-28895)
Vulnerability from cvelistv5 – Published: 2021-02-03 15:16 – Updated: 2024-08-04 16:41
VLAI
EPSS
Title
integer overflow in calloc
Summary
In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block's size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.
Severity
7.3 (High)
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://support2.windriver.com/index.php?page=def… | x_refsource_MISC |
| https://support2.windriver.com/index.php?page=cve… | x_refsource_MISC |
| https://www.oracle.com/security-alerts/cpuapr2022.html | x_refsource_MISC |
Date Public
2020-12-14 00:00
Credits
Reported by Omri Ben Bassat <v-obenbassat@microsoft.com>
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:41:00.095Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Reported by Omri Ben Bassat \u003cv-obenbassat@microsoft.com\u003e"
}
],
"datePublic": "2020-12-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-19T23:22:39.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "integer overflow in calloc",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-28895",
"STATE": "PUBLIC",
"TITLE": "integer overflow in calloc"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Reported by Omri Ben Bassat \u003cv-obenbassat@microsoft.com\u003e"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327",
"refsource": "MISC",
"url": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327"
},
{
"name": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895",
"refsource": "MISC",
"url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895"
},
{
"name": "https://www.oracle.com/security-alerts/cpuapr2022.html",
"refsource": "MISC",
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
}
]
},
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-28895",
"datePublished": "2021-02-03T15:16:34.000Z",
"dateReserved": "2020-11-17T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:41:00.095Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-35198 (GCVE-0-2020-35198)
Vulnerability from cvelistv5 – Published: 2021-05-12 10:55 – Updated: 2024-08-04 17:02
VLAI
EPSS
Summary
An issue was discovered in Wind River VxWorks 7. The memory allocator has a possible integer overflow in calculating a memory block's size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://support2.windriver.com/index.php?page=sec… | x_refsource_MISC |
| https://support2.windriver.com/index.php?page=cve… | x_refsource_MISC |
| https://www.oracle.com/security-alerts/cpuapr2022.html | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T17:02:06.842Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support2.windriver.com/index.php?page=security-notices"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-35198"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Wind River VxWorks 7. The memory allocator has a possible integer overflow in calculating a memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-19T23:22:42.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support2.windriver.com/index.php?page=security-notices"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-35198"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-35198",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in Wind River VxWorks 7. The memory allocator has a possible integer overflow in calculating a memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support2.windriver.com/index.php?page=security-notices",
"refsource": "MISC",
"url": "https://support2.windriver.com/index.php?page=security-notices"
},
{
"name": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-35198",
"refsource": "MISC",
"url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-35198"
},
{
"name": "https://www.oracle.com/security-alerts/cpuapr2022.html",
"refsource": "MISC",
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-35198",
"datePublished": "2021-05-12T10:55:47.000Z",
"dateReserved": "2020-12-12T00:00:00.000Z",
"dateUpdated": "2024-08-04T17:02:06.842Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-29241 (GCVE-0-2021-29241)
Vulnerability from cvelistv5 – Published: 2021-05-03 13:17 – Updated: 2026-05-29 14:01
VLAI
EPSS
Summary
CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS).
Severity
7.5 (High)
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://customers.codesys.com/index.php | x_refsource_MISC |
| https://customers.codesys.com/index.php?eID=dumpF… | x_refsource_MISC |
| https://www.codesys.com/security/security-reports.html | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:02:51.320Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://customers.codesys.com/index.php"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14637\u0026token=8dbd75ae7553ae3be25e22f741db783b31e14799\u0026download="
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.codesys.com/security/security-reports.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2021-29241",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:00:14.506011Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476 NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:01:18.048Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-16T13:55:07.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://customers.codesys.com/index.php"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14637\u0026token=8dbd75ae7553ae3be25e22f741db783b31e14799\u0026download="
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.codesys.com/security/security-reports.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-29241",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://customers.codesys.com/index.php",
"refsource": "MISC",
"url": "https://customers.codesys.com/index.php"
},
{
"name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14637\u0026token=8dbd75ae7553ae3be25e22f741db783b31e14799\u0026download=",
"refsource": "MISC",
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14637\u0026token=8dbd75ae7553ae3be25e22f741db783b31e14799\u0026download="
},
{
"name": "https://www.codesys.com/security/security-reports.html",
"refsource": "MISC",
"url": "https://www.codesys.com/security/security-reports.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-29241",
"datePublished": "2021-05-03T13:17:03.000Z",
"dateReserved": "2021-03-25T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:01:18.048Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-34755 (GCVE-0-2022-34755)
Vulnerability from cvelistv5 – Published: 2023-04-18 19:50 – Updated: 2025-03-03 19:21
VLAI
EPSS
Summary
A CWE-427 - Uncontrolled Search Path Element vulnerability exists that could allow an attacker
with a local privileged account to place a specially crafted file on the target machine, which may
give the attacker the ability to execute arbitrary code during the installation process initiated by a
valid user. Affected Products: Easergy Builder Installer (1.7.23 and prior)
Severity
6.3 (Medium)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Easergy Builder Installer |
Affected:
1.7.23 and prior
|
Date Public
2023-04-11 07:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:22:10.645Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-06.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-34755",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-03T17:38:04.375353Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-03T19:21:32.890Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Easergy Builder Installer",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "1.7.23 and prior"
}
]
}
],
"datePublic": "2023-04-11T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-427 - Uncontrolled Search Path Element vulnerability exists that could allow an attacker\nwith a local privileged account to place a specially crafted file on the target machine, which may\ngive the attacker the ability to execute arbitrary code during the installation process initiated by a\nvalid user. Affected Products: Easergy Builder Installer\u0026nbsp;(1.7.23 and prior)"
}
],
"value": "\nA CWE-427 - Uncontrolled Search Path Element vulnerability exists that could allow an attacker\nwith a local privileged account to place a specially crafted file on the target machine, which may\ngive the attacker the ability to execute arbitrary code during the installation process initiated by a\nvalid user. Affected Products: Easergy Builder Installer\u00a0(1.7.23 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-18T19:50:33.416Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-06.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-34755",
"datePublished": "2023-04-18T19:50:33.416Z",
"dateReserved": "2022-06-28T15:40:52.406Z",
"dateUpdated": "2025-03-03T19:21:32.890Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-4046 (GCVE-0-2022-4046)
Vulnerability from cvelistv5 – Published: 2023-08-03 12:39 – Updated: 2026-05-29 14:06
VLAI
EPSS
Title
CODESYS: Improper memory restrictions fro CODESYS Control
Summary
In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.
Severity
8.8 (High)
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
1 reference
Impacted products
14 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
all
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
all
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
all
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
all
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
all
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
all
|
Date Public
2023-08-03 10:30
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:27:54.486Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-025/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-4046",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:06:27.478239Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:06:35.326Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device."
}
],
"value": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T12:39:44.002Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-025/"
}
],
"source": {
"defect": [
"CERT@VDE#64299"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper memory restrictions fro CODESYS Control",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-4046",
"datePublished": "2023-08-03T12:39:44.002Z",
"dateReserved": "2022-11-17T07:07:09.714Z",
"dateUpdated": "2026-05-29T14:06:35.326Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-4224 (GCVE-0-2022-4224)
Vulnerability from cvelistv5 – Published: 2023-03-23 11:15 – Updated: 2026-05-29 14:08
VLAI
EPSS
Title
CODESYS: Exposure of Resource to Wrong Sphere in CODESYS V3
Summary
In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device.
Severity
8.8 (High)
CWE
- CWE-1188 - Insecure Default Initialization of Resource
Assigner
References
1 reference
Impacted products
17 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | Control RTE (SL) |
Affected:
3.0.0.0 , < 3.5.19.0
(custom)
|
|
| CODESYS | Control RTE (for Beckhoff CX) SL |
Affected:
3.0.0.0 , < 3.5.19.0
(custom)
|
|
| CODESYS | Control Win (SL) |
Affected:
3.0.0.0 , < 3.5.19.0
(custom)
|
|
| CODESYS | Runtime Toolkit |
Affected:
3.0.0.0 , < 3.5.19.0
(custom)
|
|
| CODESYS | Safety SIL2 Runtime Toolkit |
Affected:
3.0.0.0 , < 3.5.19.0
(custom)
|
|
| CODESYS | Safety SIL2 PSP |
Affected:
3.0.0.0 , < 3.5.19.0
(custom)
|
|
| CODESYS | HMI (SL) |
Affected:
3.0.0.0 , < 3.5.19.0
(custom)
|
|
| CODESYS | Development System V3 |
Affected:
3.0.0.0 , < 3.5.19.0
(custom)
|
|
| CODESYS | Control for BeagleBone SL |
Affected:
3.0.0.0 , < 4.8.0.0
(custom)
|
|
| CODESYS | Control for emPC-A/iMX6 SL |
Affected:
3.0.0.0 , < 4.8.0.0
(custom)
|
|
| CODESYS | Control for IOT2000 SL |
Affected:
3.0.0.0 , < 4.8.0.0
(custom)
|
|
| CODESYS | Control for Linux SL |
Affected:
3.0.0.0 , < 4.8.0.0
(custom)
|
|
| CODESYS | Control for PFC100 SL |
Affected:
3.0.0.0 , < 4.8.0.0
(custom)
|
|
| CODESYS | Control for PFC200 SL |
Affected:
3.0.0.0 , < 4.8.0.0
(custom)
|
|
| CODESYS | Control for PLCnext SL |
Affected:
3.0.0.0 , < 4.8.0.0
(custom)
|
|
| CODESYS | Control for Raspberry Pi SL |
Affected:
3.0.0.0 , < 4.8.0.0
(custom)
|
|
| CODESYS | Control for WAGO Touch Panels 600 SL |
Affected:
3.0.0.0 , < 4.8.0.0
(custom)
|
Credits
Franklin Zhao from ELEX FEIGONG RESEARCH INSTITUTE of Elex CyberSecurity
Reid Wightman of Dragos
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:34:49.591Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17553\u0026token=cf49757d232ea8021f0c0dd6c65e71ea5942b12d\u0026download="
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-4224",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:07:26.160566Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:08:13.754Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Control RTE (SL) ",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": " Runtime Toolkit ",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Safety SIL2 PSP",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "HMI (SL) ",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": " Control for BeagleBone SL ",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": " Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": " Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Franklin Zhao from ELEX FEIGONG RESEARCH INSTITUTE of Elex CyberSecurity"
},
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reid Wightman of Dragos"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple products of CODESYS v3 in multiple versions a remote low privileged user\u0026nbsp;could utilize this vulnerability to read and modify system files and OS resources or DoS the device."
}
],
"value": "In multiple products of CODESYS v3 in multiple versions a remote low privileged user\u00a0could utilize this vulnerability to read and modify system files and OS resources or DoS the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1188",
"description": "CWE-1188 Insecure Default Initialization of Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-09T10:47:13.144Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17553\u0026token=cf49757d232ea8021f0c0dd6c65e71ea5942b12d\u0026download="
}
],
"source": {
"defect": [
"CERT@VDE#64318"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Exposure of Resource to Wrong Sphere in CODESYS V3",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-4224",
"datePublished": "2023-03-23T11:15:37.014Z",
"dateReserved": "2022-11-30T06:54:13.183Z",
"dateUpdated": "2026-05-29T14:08:13.754Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-45788 (GCVE-0-2022-45788)
Vulnerability from cvelistv5 – Published: 2023-01-30 00:00 – Updated: 2026-05-29 14:08
VLAI
EPSS
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)
Severity
7.5 (High)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | EcoStruxure Control Expert |
Affected:
All Versions
|
|
| Schneider Electric | EcoStruxure Process Expert |
Affected:
All Versions
|
|
| Schneider Electric | Modicon M340 CPU (part numbers BMXP34*) |
Affected:
All Versions
|
|
| Schneider Electric | Modicon M580 CPU (part numbers BMEP* and BMEH*) |
Affected:
All Versions
|
|
| Schneider Electric | Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) |
Affected:
All Versions
|
|
| Schneider Electric | Modicon Momentum Unity M1E Processor (171CBU*) |
Affected:
All Versions
|
|
| Schneider Electric | Modicon MC80 (BMKC80) |
Affected:
All Versions
|
|
| Schneider Electric | Legacy Modicon Quantum (140CPU65*) and Premium CPUs (TSXP57*) |
Affected:
All Versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:17:04.131Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-05_Modicon_Controllers_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45788",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:52:24.602959Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:08:52.615Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Control Expert ",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Process Expert",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M340 CPU (part numbers BMXP34*)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU (part numbers BMEP* and BMEH*) ",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon Momentum Unity M1E Processor (171CBU*)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon MC80 (BMKC80)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Legacy Modicon Quantum (140CPU65*) and Premium CPUs (TSXP57*)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality \u0026amp; integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)\u003c/p\u003e"
}
],
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality \u0026 integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-09T13:43:07.202Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-05_Modicon_Controllers_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-45788",
"datePublished": "2023-01-30T00:00:00.000Z",
"dateReserved": "2022-11-22T00:00:00.000Z",
"dateUpdated": "2026-05-29T14:08:52.615Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-1548 (GCVE-0-2023-1548)
Vulnerability from cvelistv5 – Published: 2023-04-18 16:42 – Updated: 2025-02-05 21:14
VLAI
EPSS
Summary
A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to
perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above)
Severity
5.5 (Medium)
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | EcoStruxure Control Expert |
Affected:
V15.1 and above
|
Date Public
2023-04-11 16:26
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T05:49:11.660Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-03.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-1548",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T21:14:14.526696Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T21:14:31.860Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Control Expert",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "V15.1 and above"
}
]
}
],
"datePublic": "2023-04-11T16:26:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to\nperform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products:\u0026nbsp;EcoStruxure Control Expert (V15.1 and above)"
}
],
"value": "\nA CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to\nperform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products:\u00a0EcoStruxure Control Expert (V15.1 and above)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-12T03:14:16.623Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-03.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-1548",
"datePublished": "2023-04-18T16:42:18.451Z",
"dateReserved": "2023-03-21T13:01:16.404Z",
"dateUpdated": "2025-02-05T21:14:31.860Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-25619 (GCVE-0-2023-25619)
Vulnerability from cvelistv5 – Published: 2023-04-19 07:53 – Updated: 2025-02-05 15:08
VLAI
EPSS
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that
could cause denial of service of the controller when communicating over the Modbus TCP
protocol.
Severity
7.5 (High)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Modicon M340 CPU (part numbers BMXP34*) |
Affected:
prior to SV3.51
|
|
| Schneider Electric | Modicon M580 CPU (part numbers BMEP* and BMEH*) |
Affected:
prior to V4.10
|
|
| Schneider Electric | Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) |
Affected:
All
|
|
| Schneider Electric | Modicon Momentum Unity M1E Processor (171CBU*) |
Affected:
All
|
|
| Schneider Electric | Modicon MC80 (BMKC80) |
Affected:
All
|
|
| Schneider Electric | Legacy Modicon Quantum (140CPU65*) |
Affected:
All
|
|
| Schneider Electric | Legacy Modicon Premium CPUs (TSXP57*) |
Affected:
All
|
Date Public
2023-04-10 18:30
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:25:19.427Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-25619",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T15:07:54.659345Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T15:08:51.526Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon M340 CPU (part numbers BMXP34*) ",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "prior to SV3.51"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU (part numbers BMEP* and BMEH*)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "prior to V4.10"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All "
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon Momentum Unity M1E Processor (171CBU*)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon MC80 (BMKC80)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Legacy Modicon Quantum (140CPU65*)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Legacy Modicon Premium CPUs (TSXP57*)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All"
}
]
}
],
"datePublic": "2023-04-10T18:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when communicating over the Modbus TCP\nprotocol. \n\n"
}
],
"value": "\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when communicating over the Modbus TCP\nprotocol. \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-12T03:15:17.732Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-25619",
"datePublished": "2023-04-19T07:53:15.405Z",
"dateReserved": "2023-02-09T13:42:27.387Z",
"dateUpdated": "2025-02-05T15:08:51.526Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-25620 (GCVE-0-2023-25620)
Vulnerability from cvelistv5 – Published: 2023-04-19 08:17 – Updated: 2025-02-05 14:58
VLAI
EPSS
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that
could cause denial of service of the controller when a malicious project file is loaded onto the
controller by an authenticated user.
Severity
6.5 (Medium)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Modicon M340 CPU (part numbers BMXP34*) |
Affected:
prior to SV3.51
|
|
| Schneider Electric | Modicon M580 CPU (part numbers BMEP* and BMEH*) |
Affected:
prior to V4.10
|
|
| Schneider Electric | Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) |
Affected:
All
|
|
| Schneider Electric | Modicon Momentum Unity M1E Processor (171CBU*) |
Affected:
All
|
|
| Schneider Electric | Modicon MC80 (BMKC80) |
Affected:
All
|
|
| Schneider Electric | Legacy Modicon Quantum (140CPU65*) |
Affected:
All
|
|
| Schneider Electric | Legacy Modicon Premium CPUs (TSXP57*) |
Affected:
All
|
Date Public
2023-04-10 18:30
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:25:19.224Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-25620",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T14:57:44.416842Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T14:58:06.851Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon M340 CPU (part numbers BMXP34*) ",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "prior to SV3.51"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU (part numbers BMEP* and BMEH*)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "prior to V4.10"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All "
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon Momentum Unity M1E Processor (171CBU*)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon MC80 (BMKC80)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Legacy Modicon Quantum (140CPU65*)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Legacy Modicon Premium CPUs (TSXP57*)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All"
}
]
}
],
"datePublic": "2023-04-10T18:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\n\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when a malicious project file is loaded onto the\ncontroller by an authenticated user. \n\n \n\n"
}
],
"value": "\n\n\nA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that\ncould cause denial of service of the controller when a malicious project file is loaded onto the\ncontroller by an authenticated user. \n\n \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-12T03:15:17.732Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-25620",
"datePublished": "2023-04-19T08:17:57.240Z",
"dateReserved": "2023-02-09T13:42:27.387Z",
"dateUpdated": "2025-02-05T14:58:06.851Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Trend slope:
-
(linear fit over daily sighting counts)
Show additional events:
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…