6 vulnerabilities found for controledge_virtual_unit_operations_controller_firmware by honeywell
FKIE_CVE-2023-5390
Vulnerability from fkie_nvd - Published: 2024-01-31 18:15 - Updated: 2024-11-21 08:41
Severity ?
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Summary
An attacker could potentially exploit this vulnerability, leading to files being read from the Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC. This exploit could be used to read files from the controller that may expose limited information from the device. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:honeywell:controledge_unit_operations_controller_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B528F553-0D96-4A1D-9ABE-DA9555534BB2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:honeywell:controledge_unit_operations_controller:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E30EFCB6-6534-46EE-A743-2218FD0DAA81",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:honeywell:controledge_virtual_unit_operations_controller_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "67C0BF18-A928-4A47-A71E-2216BE4ECB90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:honeywell:controledge_virtual_unit_operations_controller:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F436C92C-7EED-44A5-B53D-12B54652D0A1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An attacker could potentially exploit this vulnerability, leading to files being read from the Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC. This exploit could be used to read files from the controller that may expose limited information from the device. Honeywell recommends updating to the most recent version of the product.\u00a0See Honeywell Security Notification for recommendations on upgrading and versioning."
},
{
"lang": "es",
"value": "Un atacante podr\u00eda explotar esta vulnerabilidad, lo que provocar\u00eda la lectura de archivos desde Honeywell Experion ControlEdge VirtualUOC y ControlEdge UOC. Esta explotaci\u00f3n podr\u00eda usarse para leer archivos del controlador que pueden exponer informaci\u00f3n limitada del dispositivo. Honeywell recomienda actualizar a la versi\u00f3n m\u00e1s reciente del producto. Consulte la Notificaci\u00f3n de seguridad de Honeywell para obtener recomendaciones sobre actualizaci\u00f3n y control de versiones."
}
],
"id": "CVE-2023-5390",
"lastModified": "2024-11-21T08:41:40.570",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "psirt@honeywell.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-01-31T18:15:46.780",
"references": [
{
"source": "psirt@honeywell.com",
"tags": [
"Product"
],
"url": "https://process.honeywell.com"
},
{
"source": "psirt@honeywell.com",
"tags": [
"Not Applicable"
],
"url": "https://www.honeywell.com/us/en/product-security"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
],
"url": "https://process.honeywell.com"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Not Applicable"
],
"url": "https://www.honeywell.com/us/en/product-security"
}
],
"sourceIdentifier": "psirt@honeywell.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-36"
}
],
"source": "psirt@honeywell.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-5389
Vulnerability from fkie_nvd - Published: 2024-01-30 20:15 - Updated: 2024-11-21 08:41
Severity ?
9.1 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Summary
An attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:honeywell:controledge_unit_operations_controller_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B528F553-0D96-4A1D-9ABE-DA9555534BB2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:honeywell:controledge_unit_operations_controller:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E30EFCB6-6534-46EE-A743-2218FD0DAA81",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:honeywell:controledge_virtual_unit_operations_controller_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "67C0BF18-A928-4A47-A71E-2216BE4ECB90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:honeywell:controledge_virtual_unit_operations_controller:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F436C92C-7EED-44A5-B53D-12B54652D0A1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\u00a0"
},
{
"lang": "es",
"value": "Un atacante podr\u00eda explotar esta vulnerabilidad, lo que permitir\u00eda modificar archivos en Honeywell Experion VirtualUOC y UOC. Esta explotaci\u00f3n podr\u00eda usarse para escribir un archivo que puede resultar en un comportamiento inesperado basado en cambios de configuraci\u00f3n o actualizaci\u00f3n de archivos que podr\u00edan resultar en la ejecuci\u00f3n posterior de una aplicaci\u00f3n maliciosa si se activa. Honeywell recomienda actualizar a la versi\u00f3n m\u00e1s reciente del producto. Consulte la Notificaci\u00f3n de seguridad de Honeywell para obtener recomendaciones sobre actualizaci\u00f3n y control de versiones."
}
],
"id": "CVE-2023-5389",
"lastModified": "2024-11-21T08:41:40.437",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2,
"source": "psirt@honeywell.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-01-30T20:15:45.420",
"references": [
{
"source": "psirt@honeywell.com",
"tags": [
"Product"
],
"url": "https://process.honeywell.com"
},
{
"source": "psirt@honeywell.com",
"tags": [
"Not Applicable"
],
"url": "https://www.honeywell.com/us/en/product-security"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
],
"url": "https://process.honeywell.com"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Not Applicable"
],
"url": "https://www.honeywell.com/us/en/product-security"
}
],
"sourceIdentifier": "psirt@honeywell.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-749"
}
],
"source": "psirt@honeywell.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2023-5390 (GCVE-0-2023-5390)
Vulnerability from cvelistv5 – Published: 2024-01-31 17:46 – Updated: 2025-05-29 15:03
VLAI?
Summary
An attacker could potentially exploit this vulnerability, leading to files being read from the Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC. This exploit could be used to read files from the controller that may expose limited information from the device. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
Severity ?
5.3 (Medium)
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Honeywell | ControlEdge UOC |
Affected:
520.2 , ≤ 520.2 TCU4
(semver)
Affected: 510.1 , ≤ 510.2 HF13 (semver) Affected: 520.1 , ≤ 520.1 TCU4 (semver) Affected: 511.1 , ≤ 511.5 TCU4 HF3 (semver) |
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:59:44.316Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://process.honeywell.com"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.honeywell.com/us/en/product-security"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5390",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-08T15:42:27.845224Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-29T15:03:38.086Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "ControlEdge UOC",
"vendor": "Honeywell",
"versions": [
{
"changes": [
{
"at": "520.2 TCU4 HF1",
"status": "unaffected"
}
],
"lessThanOrEqual": "520.2 TCU4",
"status": "affected",
"version": "520.2",
"versionType": "semver"
},
{
"changes": [
{
"at": "510.2 HF14",
"status": "unaffected"
}
],
"lessThanOrEqual": "510.2 HF13",
"status": "affected",
"version": "510.1",
"versionType": "semver"
},
{
"changes": [
{
"at": "520.1 TCU5",
"status": "unaffected"
}
],
"lessThanOrEqual": "520.1 TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"changes": [
{
"at": "511.5 TCU4 HF4",
"status": "unaffected"
}
],
"lessThanOrEqual": "511.5 TCU4 HF3",
"status": "affected",
"version": "511.1",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion LX"
],
"product": "ControlEdge UOC",
"vendor": "Honeywell",
"versions": [
{
"changes": [
{
"at": "520.2 TCU4 HF2",
"status": "unaffected"
}
],
"lessThanOrEqual": "520.2 TCU4",
"status": "affected",
"version": "520.2",
"versionType": "semver"
},
{
"changes": [
{
"at": "511.5 TCU4 HF4",
"status": "unaffected"
}
],
"lessThanOrEqual": "511.5 TCU4 HF3",
"status": "affected",
"version": "511.1",
"versionType": "semver"
},
{
"changes": [
{
"at": "520.1 TCU5",
"status": "unaffected"
}
],
"lessThanOrEqual": "520.1 TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"PlantCruise by Experion"
],
"product": "ControlEdge UOC",
"vendor": "Honeywell",
"versions": [
{
"changes": [
{
"at": "520.2 TCU4 HF2",
"status": "unaffected"
}
],
"lessThanOrEqual": "520.2 TCU4",
"status": "affected",
"version": "520.2",
"versionType": "semver"
},
{
"changes": [
{
"at": "520.1 TCU5",
"status": "unaffected"
}
],
"lessThanOrEqual": "520.1 TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"changes": [
{
"at": "511.5 TCU4 HF4",
"status": "unaffected"
}
],
"lessThanOrEqual": "511.5 TCU4 HF3",
"status": "affected",
"version": "520.2 TCU4 HFR2",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An attacker could potentially exploit this vulnerability, leading to files being read from the Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC. This exploit could be used to read files from the controller that may expose limited information from the device. Honeywell recommends updating to the most recent version of the product.\u0026nbsp;See Honeywell Security Notification for recommendations on upgrading and versioning.\n\n\u003cbr\u003e"
}
],
"value": "An attacker could potentially exploit this vulnerability, leading to files being read from the Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC. This exploit could be used to read files from the controller that may expose limited information from the device. Honeywell recommends updating to the most recent version of the product.\u00a0See Honeywell Security Notification for recommendations on upgrading and versioning."
}
],
"impacts": [
{
"capecId": "CAPEC-126",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-126"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-36",
"description": "CWE-36",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T19:56:46.965Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com"
},
{
"url": "https://www.honeywell.com/us/en/product-security"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2023-5390",
"datePublished": "2024-01-31T17:46:39.809Z",
"dateReserved": "2023-10-04T17:50:05.792Z",
"dateUpdated": "2025-05-29T15:03:38.086Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5389 (GCVE-0-2023-5389)
Vulnerability from cvelistv5 – Published: 2024-01-30 20:00 – Updated: 2025-06-17 21:29
VLAI?
Summary
An attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
Severity ?
9.1 (Critical)
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Honeywell | ControlEdge UOC |
Affected:
520.2 , ≤ 520.2 TCU4
(semver)
Affected: 510.1 , ≤ 510.2 HF13 (semver) Affected: 520.1 , ≤ 520.1 TCU4 (semver) Affected: 511.1 , ≤ 511.5 TCU4 HF3 (semver) |
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:59:44.048Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://process.honeywell.com"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.honeywell.com/us/en/product-security"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5389",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-31T15:30:52.882701Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T21:29:17.826Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "ControlEdge UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU4",
"status": "affected",
"version": "520.2",
"versionType": "semver"
},
{
"lessThanOrEqual": "510.2 HF13",
"status": "affected",
"version": "510.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "520.1 TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "511.5 TCU4 HF3",
"status": "affected",
"version": "511.1",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion LX"
],
"product": "ControlEdge UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU4",
"status": "affected",
"version": "520.2",
"versionType": "semver"
},
{
"lessThanOrEqual": "511.5 TCU4 HF3",
"status": "affected",
"version": "511.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "520.1 TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"PlantCruise by Experion"
],
"product": "ControlEdge UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU4",
"status": "affected",
"version": "520.2",
"versionType": "semver"
},
{
"lessThanOrEqual": "520.1 TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "511.5 TCU4 HF3",
"status": "affected",
"version": "520.2 TCU4 HFR2",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\u0026nbsp;"
}
],
"value": "\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\u00a0"
}
],
"impacts": [
{
"capecId": "CAPEC-126",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-126"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-749",
"description": "CWE-749",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-25T16:54:14.096Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com"
},
{
"url": "https://www.honeywell.com/us/en/product-security"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2023-5389",
"datePublished": "2024-01-30T20:00:50.382Z",
"dateReserved": "2023-10-04T17:49:59.920Z",
"dateUpdated": "2025-06-17T21:29:17.826Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5390 (GCVE-0-2023-5390)
Vulnerability from nvd – Published: 2024-01-31 17:46 – Updated: 2025-05-29 15:03
VLAI?
Summary
An attacker could potentially exploit this vulnerability, leading to files being read from the Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC. This exploit could be used to read files from the controller that may expose limited information from the device. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
Severity ?
5.3 (Medium)
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Honeywell | ControlEdge UOC |
Affected:
520.2 , ≤ 520.2 TCU4
(semver)
Affected: 510.1 , ≤ 510.2 HF13 (semver) Affected: 520.1 , ≤ 520.1 TCU4 (semver) Affected: 511.1 , ≤ 511.5 TCU4 HF3 (semver) |
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:59:44.316Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://process.honeywell.com"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.honeywell.com/us/en/product-security"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5390",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-08T15:42:27.845224Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-29T15:03:38.086Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "ControlEdge UOC",
"vendor": "Honeywell",
"versions": [
{
"changes": [
{
"at": "520.2 TCU4 HF1",
"status": "unaffected"
}
],
"lessThanOrEqual": "520.2 TCU4",
"status": "affected",
"version": "520.2",
"versionType": "semver"
},
{
"changes": [
{
"at": "510.2 HF14",
"status": "unaffected"
}
],
"lessThanOrEqual": "510.2 HF13",
"status": "affected",
"version": "510.1",
"versionType": "semver"
},
{
"changes": [
{
"at": "520.1 TCU5",
"status": "unaffected"
}
],
"lessThanOrEqual": "520.1 TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"changes": [
{
"at": "511.5 TCU4 HF4",
"status": "unaffected"
}
],
"lessThanOrEqual": "511.5 TCU4 HF3",
"status": "affected",
"version": "511.1",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion LX"
],
"product": "ControlEdge UOC",
"vendor": "Honeywell",
"versions": [
{
"changes": [
{
"at": "520.2 TCU4 HF2",
"status": "unaffected"
}
],
"lessThanOrEqual": "520.2 TCU4",
"status": "affected",
"version": "520.2",
"versionType": "semver"
},
{
"changes": [
{
"at": "511.5 TCU4 HF4",
"status": "unaffected"
}
],
"lessThanOrEqual": "511.5 TCU4 HF3",
"status": "affected",
"version": "511.1",
"versionType": "semver"
},
{
"changes": [
{
"at": "520.1 TCU5",
"status": "unaffected"
}
],
"lessThanOrEqual": "520.1 TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"PlantCruise by Experion"
],
"product": "ControlEdge UOC",
"vendor": "Honeywell",
"versions": [
{
"changes": [
{
"at": "520.2 TCU4 HF2",
"status": "unaffected"
}
],
"lessThanOrEqual": "520.2 TCU4",
"status": "affected",
"version": "520.2",
"versionType": "semver"
},
{
"changes": [
{
"at": "520.1 TCU5",
"status": "unaffected"
}
],
"lessThanOrEqual": "520.1 TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"changes": [
{
"at": "511.5 TCU4 HF4",
"status": "unaffected"
}
],
"lessThanOrEqual": "511.5 TCU4 HF3",
"status": "affected",
"version": "520.2 TCU4 HFR2",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An attacker could potentially exploit this vulnerability, leading to files being read from the Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC. This exploit could be used to read files from the controller that may expose limited information from the device. Honeywell recommends updating to the most recent version of the product.\u0026nbsp;See Honeywell Security Notification for recommendations on upgrading and versioning.\n\n\u003cbr\u003e"
}
],
"value": "An attacker could potentially exploit this vulnerability, leading to files being read from the Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC. This exploit could be used to read files from the controller that may expose limited information from the device. Honeywell recommends updating to the most recent version of the product.\u00a0See Honeywell Security Notification for recommendations on upgrading and versioning."
}
],
"impacts": [
{
"capecId": "CAPEC-126",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-126"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-36",
"description": "CWE-36",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T19:56:46.965Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com"
},
{
"url": "https://www.honeywell.com/us/en/product-security"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2023-5390",
"datePublished": "2024-01-31T17:46:39.809Z",
"dateReserved": "2023-10-04T17:50:05.792Z",
"dateUpdated": "2025-05-29T15:03:38.086Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5389 (GCVE-0-2023-5389)
Vulnerability from nvd – Published: 2024-01-30 20:00 – Updated: 2025-06-17 21:29
VLAI?
Summary
An attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
Severity ?
9.1 (Critical)
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Honeywell | ControlEdge UOC |
Affected:
520.2 , ≤ 520.2 TCU4
(semver)
Affected: 510.1 , ≤ 510.2 HF13 (semver) Affected: 520.1 , ≤ 520.1 TCU4 (semver) Affected: 511.1 , ≤ 511.5 TCU4 HF3 (semver) |
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:59:44.048Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://process.honeywell.com"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.honeywell.com/us/en/product-security"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5389",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-31T15:30:52.882701Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T21:29:17.826Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "ControlEdge UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU4",
"status": "affected",
"version": "520.2",
"versionType": "semver"
},
{
"lessThanOrEqual": "510.2 HF13",
"status": "affected",
"version": "510.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "520.1 TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "511.5 TCU4 HF3",
"status": "affected",
"version": "511.1",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion LX"
],
"product": "ControlEdge UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU4",
"status": "affected",
"version": "520.2",
"versionType": "semver"
},
{
"lessThanOrEqual": "511.5 TCU4 HF3",
"status": "affected",
"version": "511.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "520.1 TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"PlantCruise by Experion"
],
"product": "ControlEdge UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU4",
"status": "affected",
"version": "520.2",
"versionType": "semver"
},
{
"lessThanOrEqual": "520.1 TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "511.5 TCU4 HF3",
"status": "affected",
"version": "520.2 TCU4 HFR2",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\u0026nbsp;"
}
],
"value": "\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\u00a0"
}
],
"impacts": [
{
"capecId": "CAPEC-126",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-126"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-749",
"description": "CWE-749",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-25T16:54:14.096Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com"
},
{
"url": "https://www.honeywell.com/us/en/product-security"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2023-5389",
"datePublished": "2024-01-30T20:00:50.382Z",
"dateReserved": "2023-10-04T17:49:59.920Z",
"dateUpdated": "2025-06-17T21:29:17.826Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}