CVE-2023-5389 (GCVE-0-2023-5389)
Vulnerability from cvelistv5 – Published: 2024-01-30 20:00 – Updated: 2025-06-17 21:29
VLAI?
Summary
An attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
Severity ?
9.1 (Critical)
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Honeywell | ControlEdge UOC |
Affected:
520.2 , ≤ 520.2 TCU4
(semver)
Affected: 510.1 , ≤ 510.2 HF13 (semver) Affected: 520.1 , ≤ 520.1 TCU4 (semver) Affected: 511.1 , ≤ 511.5 TCU4 HF3 (semver) |
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:59:44.048Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://process.honeywell.com"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.honeywell.com/us/en/product-security"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5389",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-31T15:30:52.882701Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T21:29:17.826Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Experion PKS"
],
"product": "ControlEdge UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU4",
"status": "affected",
"version": "520.2",
"versionType": "semver"
},
{
"lessThanOrEqual": "510.2 HF13",
"status": "affected",
"version": "510.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "520.1 TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "511.5 TCU4 HF3",
"status": "affected",
"version": "511.1",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Experion LX"
],
"product": "ControlEdge UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU4",
"status": "affected",
"version": "520.2",
"versionType": "semver"
},
{
"lessThanOrEqual": "511.5 TCU4 HF3",
"status": "affected",
"version": "511.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "520.1 TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"PlantCruise by Experion"
],
"product": "ControlEdge UOC",
"vendor": "Honeywell",
"versions": [
{
"lessThanOrEqual": "520.2 TCU4",
"status": "affected",
"version": "520.2",
"versionType": "semver"
},
{
"lessThanOrEqual": "520.1 TCU4",
"status": "affected",
"version": "520.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "511.5 TCU4 HF3",
"status": "affected",
"version": "520.2 TCU4 HFR2",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\u0026nbsp;"
}
],
"value": "\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\u00a0"
}
],
"impacts": [
{
"capecId": "CAPEC-126",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-126"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-749",
"description": "CWE-749",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-25T16:54:14.096Z",
"orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"shortName": "Honeywell"
},
"references": [
{
"url": "https://process.honeywell.com"
},
{
"url": "https://www.honeywell.com/us/en/product-security"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
"assignerShortName": "Honeywell",
"cveId": "CVE-2023-5389",
"datePublished": "2024-01-30T20:00:50.382Z",
"dateReserved": "2023-10-04T17:49:59.920Z",
"dateUpdated": "2025-06-17T21:29:17.826Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:honeywell:controledge_unit_operations_controller_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B528F553-0D96-4A1D-9ABE-DA9555534BB2\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:honeywell:controledge_unit_operations_controller:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E30EFCB6-6534-46EE-A743-2218FD0DAA81\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:honeywell:controledge_virtual_unit_operations_controller_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"67C0BF18-A928-4A47-A71E-2216BE4ECB90\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:honeywell:controledge_virtual_unit_operations_controller:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F436C92C-7EED-44A5-B53D-12B54652D0A1\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"\\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\\u00a0\"}, {\"lang\": \"es\", \"value\": \"Un atacante podr\\u00eda explotar esta vulnerabilidad, lo que permitir\\u00eda modificar archivos en Honeywell Experion VirtualUOC y UOC. Esta explotaci\\u00f3n podr\\u00eda usarse para escribir un archivo que puede resultar en un comportamiento inesperado basado en cambios de configuraci\\u00f3n o actualizaci\\u00f3n de archivos que podr\\u00edan resultar en la ejecuci\\u00f3n posterior de una aplicaci\\u00f3n maliciosa si se activa. Honeywell recomienda actualizar a la versi\\u00f3n m\\u00e1s reciente del producto. Consulte la Notificaci\\u00f3n de seguridad de Honeywell para obtener recomendaciones sobre actualizaci\\u00f3n y control de versiones.\"}]",
"id": "CVE-2023-5389",
"lastModified": "2024-11-21T08:41:40.437",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"psirt@honeywell.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\", \"baseScore\": 9.1, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.2}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
"published": "2024-01-30T20:15:45.420",
"references": "[{\"url\": \"https://process.honeywell.com\", \"source\": \"psirt@honeywell.com\", \"tags\": [\"Product\"]}, {\"url\": \"https://www.honeywell.com/us/en/product-security\", \"source\": \"psirt@honeywell.com\", \"tags\": [\"Not Applicable\"]}, {\"url\": \"https://process.honeywell.com\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Product\"]}, {\"url\": \"https://www.honeywell.com/us/en/product-security\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Not Applicable\"]}]",
"sourceIdentifier": "psirt@honeywell.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"psirt@honeywell.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-749\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-Other\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-5389\",\"sourceIdentifier\":\"psirt@honeywell.com\",\"published\":\"2024-01-30T20:15:45.420\",\"lastModified\":\"2024-11-21T08:41:40.437\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\u00a0\"},{\"lang\":\"es\",\"value\":\"Un atacante podr\u00eda explotar esta vulnerabilidad, lo que permitir\u00eda modificar archivos en Honeywell Experion VirtualUOC y UOC. Esta explotaci\u00f3n podr\u00eda usarse para escribir un archivo que puede resultar en un comportamiento inesperado basado en cambios de configuraci\u00f3n o actualizaci\u00f3n de archivos que podr\u00edan resultar en la ejecuci\u00f3n posterior de una aplicaci\u00f3n maliciosa si se activa. Honeywell recomienda actualizar a la versi\u00f3n m\u00e1s reciente del producto. Consulte la Notificaci\u00f3n de seguridad de Honeywell para obtener recomendaciones sobre actualizaci\u00f3n y control de versiones.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@honeywell.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"psirt@honeywell.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-749\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:honeywell:controledge_unit_operations_controller_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B528F553-0D96-4A1D-9ABE-DA9555534BB2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:honeywell:controledge_unit_operations_controller:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E30EFCB6-6534-46EE-A743-2218FD0DAA81\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:honeywell:controledge_virtual_unit_operations_controller_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"67C0BF18-A928-4A47-A71E-2216BE4ECB90\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:honeywell:controledge_virtual_unit_operations_controller:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F436C92C-7EED-44A5-B53D-12B54652D0A1\"}]}]}],\"references\":[{\"url\":\"https://process.honeywell.com\",\"source\":\"psirt@honeywell.com\",\"tags\":[\"Product\"]},{\"url\":\"https://www.honeywell.com/us/en/product-security\",\"source\":\"psirt@honeywell.com\",\"tags\":[\"Not Applicable\"]},{\"url\":\"https://process.honeywell.com\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Product\"]},{\"url\":\"https://www.honeywell.com/us/en/product-security\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Not Applicable\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://process.honeywell.com\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://www.honeywell.com/us/en/product-security\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T07:59:44.048Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-5389\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-01-31T15:30:52.882701Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-06-17T21:19:49.740Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-126\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-126\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Honeywell\", \"product\": \"ControlEdge UOC\", \"versions\": [{\"status\": \"affected\", \"version\": \"520.2\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"520.2 TCU4\"}, {\"status\": \"affected\", \"version\": \"510.1\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"510.2 HF13\"}, {\"status\": \"affected\", \"version\": \"520.1\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"520.1 TCU4\"}, {\"status\": \"affected\", \"version\": \"511.1\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"511.5 TCU4 HF3\"}], \"platforms\": [\"Experion PKS\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Honeywell\", \"product\": \"ControlEdge UOC\", \"versions\": [{\"status\": \"affected\", \"version\": \"520.2\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"520.2 TCU4\"}, {\"status\": \"affected\", \"version\": \"511.1\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"511.5 TCU4 HF3\"}, {\"status\": \"affected\", \"version\": \"520.1\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"520.1 TCU4\"}], \"platforms\": [\"Experion LX\"], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Honeywell\", \"product\": \"ControlEdge UOC\", \"versions\": [{\"status\": \"affected\", \"version\": \"520.2\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"520.2 TCU4\"}, {\"status\": \"affected\", \"version\": \"520.1\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"520.1 TCU4\"}, {\"status\": \"affected\", \"version\": \"520.2 TCU4 HFR2\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"511.5 TCU4 HF3\"}], \"platforms\": [\"PlantCruise by Experion\"], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://process.honeywell.com\"}, {\"url\": \"https://www.honeywell.com/us/en/product-security\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\\u00a0\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\u0026nbsp;\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-749\", \"description\": \"CWE-749\"}]}], \"providerMetadata\": {\"orgId\": \"0dc86260-d7e3-4e81-ba06-3508e030ce8d\", \"shortName\": \"Honeywell\", \"dateUpdated\": \"2024-04-25T16:54:14.096Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-5389\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-06-17T21:29:17.826Z\", \"dateReserved\": \"2023-10-04T17:49:59.920Z\", \"assignerOrgId\": \"0dc86260-d7e3-4e81-ba06-3508e030ce8d\", \"datePublished\": \"2024-01-30T20:00:50.382Z\", \"assignerShortName\": \"Honeywell\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…