cve-2023-5389
Vulnerability from cvelistv5
Published
2024-01-30 20:00
Modified
2024-08-02 07:59
Severity ?
Summary
An attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning. 
Impacted products
Vendor Product Version
Honeywell ControlEdge UOC Version: 520.2    520.2 TCU4
Version: 511.1    511.5 TCU4 HF3
Version: 520.1    520.1 TCU4
Honeywell ControlEdge UOC Version: 520.2    520.2 TCU4
Version: 520.1    520.1 TCU4
Version: 520.2 TCU4 HFR2    511.5 TCU4 HF3
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:59:44.048Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://process.honeywell.com"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.honeywell.com/us/en/product-security"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Experion PKS"
          ],
          "product": "ControlEdge UOC",
          "vendor": "Honeywell",
          "versions": [
            {
              "lessThanOrEqual": "520.2 TCU4",
              "status": "affected",
              "version": "520.2",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "510.2 HF13",
              "status": "affected",
              "version": "510.1",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "520.1 TCU4",
              "status": "affected",
              "version": "520.1",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "511.5 TCU4 HF3",
              "status": "affected",
              "version": "511.1",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Experion LX"
          ],
          "product": "ControlEdge UOC",
          "vendor": "Honeywell",
          "versions": [
            {
              "lessThanOrEqual": "520.2 TCU4",
              "status": "affected",
              "version": "520.2",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "511.5 TCU4 HF3",
              "status": "affected",
              "version": "511.1",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "520.1 TCU4",
              "status": "affected",
              "version": "520.1",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "PlantCruise by Experion"
          ],
          "product": "ControlEdge UOC",
          "vendor": "Honeywell",
          "versions": [
            {
              "lessThanOrEqual": "520.2 TCU4",
              "status": "affected",
              "version": "520.2",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "520.1 TCU4",
              "status": "affected",
              "version": "520.1",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "511.5 TCU4 HF3",
              "status": "affected",
              "version": "520.2 TCU4 HFR2",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\u0026nbsp;"
            }
          ],
          "value": "\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\u00a0"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-126",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-126"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-749",
              "description": "CWE-749",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-25T16:54:14.096Z",
        "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "shortName": "Honeywell"
      },
      "references": [
        {
          "url": "https://process.honeywell.com"
        },
        {
          "url": "https://www.honeywell.com/us/en/product-security"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
    "assignerShortName": "Honeywell",
    "cveId": "CVE-2023-5389",
    "datePublished": "2024-01-30T20:00:50.382Z",
    "dateReserved": "2023-10-04T17:49:59.920Z",
    "dateUpdated": "2024-08-02T07:59:44.048Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-5389\",\"sourceIdentifier\":\"psirt@honeywell.com\",\"published\":\"2024-01-30T20:15:45.420\",\"lastModified\":\"2024-11-21T08:41:40.437\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\u00a0\"},{\"lang\":\"es\",\"value\":\"Un atacante podr\u00eda explotar esta vulnerabilidad, lo que permitir\u00eda modificar archivos en Honeywell Experion VirtualUOC y UOC. Esta explotaci\u00f3n podr\u00eda usarse para escribir un archivo que puede resultar en un comportamiento inesperado basado en cambios de configuraci\u00f3n o actualizaci\u00f3n de archivos que podr\u00edan resultar en la ejecuci\u00f3n posterior de una aplicaci\u00f3n maliciosa si se activa. Honeywell recomienda actualizar a la versi\u00f3n m\u00e1s reciente del producto. Consulte la Notificaci\u00f3n de seguridad de Honeywell para obtener recomendaciones sobre actualizaci\u00f3n y control de versiones.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@honeywell.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"psirt@honeywell.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-749\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:honeywell:controledge_unit_operations_controller_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B528F553-0D96-4A1D-9ABE-DA9555534BB2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:honeywell:controledge_unit_operations_controller:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E30EFCB6-6534-46EE-A743-2218FD0DAA81\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:honeywell:controledge_virtual_unit_operations_controller_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"67C0BF18-A928-4A47-A71E-2216BE4ECB90\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:honeywell:controledge_virtual_unit_operations_controller:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F436C92C-7EED-44A5-B53D-12B54652D0A1\"}]}]}],\"references\":[{\"url\":\"https://process.honeywell.com\",\"source\":\"psirt@honeywell.com\",\"tags\":[\"Product\"]},{\"url\":\"https://www.honeywell.com/us/en/product-security\",\"source\":\"psirt@honeywell.com\",\"tags\":[\"Not Applicable\"]},{\"url\":\"https://process.honeywell.com\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Product\"]},{\"url\":\"https://www.honeywell.com/us/en/product-security\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Not Applicable\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.