CVE-2023-5389
Vulnerability from cvelistv5
Published
2024-01-30 20:00
Modified
2024-08-02 07:59
Severity ?
EPSS score ?
Summary
An attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
References
▼ | URL | Tags | |
---|---|---|---|
psirt@honeywell.com | https://process.honeywell.com | Product | |
psirt@honeywell.com | https://www.honeywell.com/us/en/product-security | Not Applicable |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T07:59:44.048Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://process.honeywell.com" }, { "tags": [ "x_transferred" ], "url": "https://www.honeywell.com/us/en/product-security" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "platforms": [ "Experion PKS" ], "product": "ControlEdge UOC", "vendor": "Honeywell", "versions": [ { "lessThanOrEqual": "520.2 TCU4", "status": "affected", "version": "520.2", "versionType": "semver" }, { "lessThanOrEqual": "510.2 HF13", "status": "affected", "version": "510.1", "versionType": "semver" }, { "lessThanOrEqual": "520.1 TCU4", "status": "affected", "version": "520.1", "versionType": "semver" }, { "lessThanOrEqual": "511.5 TCU4 HF3", "status": "affected", "version": "511.1", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Experion LX" ], "product": "ControlEdge UOC", "vendor": "Honeywell", "versions": [ { "lessThanOrEqual": "520.2 TCU4", "status": "affected", "version": "520.2", "versionType": "semver" }, { "lessThanOrEqual": "511.5 TCU4 HF3", "status": "affected", "version": "511.1", "versionType": "semver" }, { "lessThanOrEqual": "520.1 TCU4", "status": "affected", "version": "520.1", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "platforms": [ "PlantCruise by Experion" ], "product": "ControlEdge UOC", "vendor": "Honeywell", "versions": [ { "lessThanOrEqual": "520.2 TCU4", "status": "affected", "version": "520.2", "versionType": "semver" }, { "lessThanOrEqual": "520.1 TCU4", "status": "affected", "version": "520.1", "versionType": "semver" }, { "lessThanOrEqual": "511.5 TCU4 HF3", "status": "affected", "version": "520.2 TCU4 HFR2", "versionType": "semver" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\u0026nbsp;" } ], "value": "\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\u00a0" } ], "impacts": [ { "capecId": "CAPEC-126", "descriptions": [ { "lang": "en", "value": "CAPEC-126" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-749", "description": "CWE-749", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-25T16:54:14.096Z", "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d", "shortName": "Honeywell" }, "references": [ { "url": "https://process.honeywell.com" }, { "url": "https://www.honeywell.com/us/en/product-security" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d", "assignerShortName": "Honeywell", "cveId": "CVE-2023-5389", "datePublished": "2024-01-30T20:00:50.382Z", "dateReserved": "2023-10-04T17:49:59.920Z", "dateUpdated": "2024-08-02T07:59:44.048Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-5389\",\"sourceIdentifier\":\"psirt@honeywell.com\",\"published\":\"2024-01-30T20:15:45.420\",\"lastModified\":\"2024-02-08T15:20:04.057\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.\u00a0\"},{\"lang\":\"es\",\"value\":\"Un atacante podr\u00eda explotar esta vulnerabilidad, lo que permitir\u00eda modificar archivos en Honeywell Experion VirtualUOC y UOC. Esta explotaci\u00f3n podr\u00eda usarse para escribir un archivo que puede resultar en un comportamiento inesperado basado en cambios de configuraci\u00f3n o actualizaci\u00f3n de archivos que podr\u00edan resultar en la ejecuci\u00f3n posterior de una aplicaci\u00f3n maliciosa si se activa. Honeywell recomienda actualizar a la versi\u00f3n m\u00e1s reciente del producto. Consulte la Notificaci\u00f3n de seguridad de Honeywell para obtener recomendaciones sobre actualizaci\u00f3n y control de versiones.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"psirt@honeywell.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]},{\"source\":\"psirt@honeywell.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-749\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:honeywell:controledge_unit_operations_controller_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B528F553-0D96-4A1D-9ABE-DA9555534BB2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:honeywell:controledge_unit_operations_controller:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E30EFCB6-6534-46EE-A743-2218FD0DAA81\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:honeywell:controledge_virtual_unit_operations_controller_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"67C0BF18-A928-4A47-A71E-2216BE4ECB90\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:honeywell:controledge_virtual_unit_operations_controller:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F436C92C-7EED-44A5-B53D-12B54652D0A1\"}]}]}],\"references\":[{\"url\":\"https://process.honeywell.com\",\"source\":\"psirt@honeywell.com\",\"tags\":[\"Product\"]},{\"url\":\"https://www.honeywell.com/us/en/product-security\",\"source\":\"psirt@honeywell.com\",\"tags\":[\"Not Applicable\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.