Search criteria

36 vulnerabilities found for emc_unityvsa_operating_environment by dell

FKIE_CVE-2022-22564

Vulnerability from fkie_nvd - Published: 2023-02-14 16:15 - Updated: 2024-11-21 06:47
Summary
Dell EMC Unity versions before 5.2.0.0.5.173 , use(es) broken cryptographic algorithm. A remote unauthenticated attacker could potentially exploit this vulnerability by performing MitM attacks and let attackers obtain sensitive information.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dell:emc_unity_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23363672-9F80-4B23-B161-CB8372250A76",
              "versionEndExcluding": "5.2.0.0.5.173",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:emc_unity_xt_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "95342D1C-93B8-4ADD-8037-5830379BD409",
              "versionEndExcluding": "5.2.0.0.5.173",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:emc_unityvsa_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B1C9B66-EEF8-499E-AB94-1C21E24631DD",
              "versionEndExcluding": "5.2.0.0.5.173",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell EMC Unity versions before 5.2.0.0.5.173 , use(es) broken cryptographic algorithm. A remote unauthenticated attacker could potentially exploit this vulnerability by performing MitM attacks and let attackers obtain sensitive information.\n\n"
    }
  ],
  "id": "CVE-2022-22564",
  "lastModified": "2024-11-21T06:47:02.150",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 3.6,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-02-14T16:15:11.163",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/kbdoc/en-us/000199050/dsa-2022-021-dell-unity-dell-unityvsa-and-dell-unity-xt-security-update-for-multiple-vulnerabilities"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/kbdoc/en-us/000199050/dsa-2022-021-dell-unity-dell-unityvsa-and-dell-unity-xt-security-update-for-multiple-vulnerabilities"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-327"
        }
      ],
      "source": "security_alert@emc.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-327"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-43589

Vulnerability from fkie_nvd - Published: 2022-01-24 20:15 - Updated: 2024-11-21 06:29
Summary
Dell EMC Unity, Dell EMC UnityVSA and Dell EMC Unity XT versions prior to 5.1.2.0.5.007 contain an operating system (OS) command injection Vulnerability. A locally authenticated user with high privileges may potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the Unity underlying OS, with the privileges of the vulnerable application. Exploitation may lead to an elevation of privilege.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dell:emc_unity_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C4D689C-20B4-46FD-AE77-4AA355420792",
              "versionEndExcluding": "5.1.2.0.5.007",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:emc_unity_xt_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D95F7E94-753D-49AB-9F22-3C1B8C2FA560",
              "versionEndExcluding": "5.1.2.0.5.007",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:emc_unityvsa_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5315ADAF-F00C-4A7A-8C19-3EF954EE99F6",
              "versionEndExcluding": "5.1.2.0.5.007",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell EMC Unity, Dell EMC UnityVSA and Dell EMC Unity XT versions prior to 5.1.2.0.5.007 contain an operating system (OS) command injection Vulnerability. A locally authenticated user with high privileges may potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the Unity underlying OS, with the privileges of the vulnerable application. Exploitation may lead to an elevation of privilege."
    },
    {
      "lang": "es",
      "value": "Dell EMC Unity, Dell EMC UnityVSA y Dell EMC Unity XT versiones anteriores a 5.1.2.0.5.007, contienen una vulnerabilidad de inyecci\u00f3n de comandos del sistema operativo (SO). Un usuario autenticado localmente con altos privilegios puede potencialmente explotar esta vulnerabilidad, conllevando a una ejecuci\u00f3n de comandos arbitrarios del SO en el SO subyacente de Unity, con los privilegios de la aplicaci\u00f3n vulnerable. Una explotaci\u00f3n puede conllevar a una elevaci\u00f3n de privilegios"
    }
  ],
  "id": "CVE-2021-43589",
  "lastModified": "2024-11-21T06:29:29.913",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.2,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.0,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 5.2,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-01-24T20:15:08.227",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "security_alert@emc.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-21591

Vulnerability from fkie_nvd - Published: 2021-07-12 16:15 - Updated: 2024-11-21 05:48
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dell:emc_unity_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "531AB7E0-ACA7-4C07-A4B4-500D16A894EA",
              "versionEndExcluding": "5.1.0.0.5.394",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:emc_unity_xt_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2F3F015-06EF-4E9F-895F-CCE3580C1178",
              "versionEndExcluding": "5.1.0.0.5.394",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:emc_unityvsa_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61642158-7A1F-4563-ABFF-089EDD975AB1",
              "versionEndExcluding": "5.1.0.0.5.394",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
    },
    {
      "lang": "es",
      "value": "Dell EMC Unity, Unity XT y UnityVSA versiones anteriores a 5.1.0.5.394, contienen una vulnerabilidad de almacenamiento de contrase\u00f1as en texto plano. Un usuario local malicioso con altos privilegios puede usar la contrase\u00f1a expuesta para conseguir acceso con los privilegios del usuario comprometido"
    }
  ],
  "id": "CVE-2021-21591",
  "lastModified": "2024-11-21T05:48:39.740",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.5,
        "impactScore": 5.9,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-07-12T16:15:08.867",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/kbdoc/000189204"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/kbdoc/000189204"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "security_alert@emc.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-21590

Vulnerability from fkie_nvd - Published: 2021-07-12 16:15 - Updated: 2024-11-21 05:48
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dell:emc_unity_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "531AB7E0-ACA7-4C07-A4B4-500D16A894EA",
              "versionEndExcluding": "5.1.0.0.5.394",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:emc_unity_xt_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2F3F015-06EF-4E9F-895F-CCE3580C1178",
              "versionEndExcluding": "5.1.0.0.5.394",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:emc_unityvsa_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61642158-7A1F-4563-ABFF-089EDD975AB1",
              "versionEndExcluding": "5.1.0.0.5.394",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
    },
    {
      "lang": "es",
      "value": "Dell EMC Unity, Unity XT y UnityVSA versiones anteriores a 5.1.0.5.394, contienen una vulnerabilidad en el almacenamiento de contrase\u00f1as de texto plano. Un usuario local malicioso con altos privilegios puede usar la contrase\u00f1a expuesta para conseguir acceso con los privilegios del usuario comprometido"
    }
  ],
  "id": "CVE-2021-21590",
  "lastModified": "2024-11-21T05:48:39.630",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.5,
        "impactScore": 5.9,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-07-12T16:15:08.763",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/kbdoc/000189204"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/kbdoc/000189204"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "security_alert@emc.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-21589

Vulnerability from fkie_nvd - Published: 2021-07-12 16:15 - Updated: 2024-11-21 05:48
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 do not exit on failed Initialization. A local authenticated Service user could potentially exploit this vulnerability to escalate privileges.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dell:emc_unity_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "531AB7E0-ACA7-4C07-A4B4-500D16A894EA",
              "versionEndExcluding": "5.1.0.0.5.394",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:emc_unity_xt_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2F3F015-06EF-4E9F-895F-CCE3580C1178",
              "versionEndExcluding": "5.1.0.0.5.394",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:emc_unityvsa_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61642158-7A1F-4563-ABFF-089EDD975AB1",
              "versionEndExcluding": "5.1.0.0.5.394",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 do not exit on failed Initialization. A local authenticated Service user could potentially exploit this vulnerability to escalate privileges."
    },
    {
      "lang": "es",
      "value": "Dell EMC Unity, Unity XT y UnityVSA versiones anteriores a 5.1.0.5.394, no escapan en un fallo de inicializaci\u00f3n. Un usuario local autenticado del Servicio podr\u00eda explotar potencialmente esta vulnerabilidad para escalar privilegios"
    }
  ],
  "id": "CVE-2021-21589",
  "lastModified": "2024-11-21T05:48:39.527",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 5.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.5,
        "impactScore": 5.2,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-07-12T16:15:08.680",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/kbdoc/000189204"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/kbdoc/000189204"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2020-5319

Vulnerability from fkie_nvd - Published: 2020-02-06 18:15 - Updated: 2024-11-21 05:33
Summary
Dell EMC Unity, Dell EMC Unity XT, and Dell EMC UnityVSA versions prior to 5.0.2.0.5.009 contain a Denial of Service vulnerability on NAS Server SSH implementation that is used to provide SFTP service on a NAS server. A remote unauthenticated attacker may potentially exploit this vulnerability and cause a Denial of Service (Storage Processor Panic) by sending an out of order SSH protocol sequence.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dell:emc_unity_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9A9AF055-C271-4890-B409-CB5A9A73E6F1",
              "versionEndExcluding": "5.0.2.0.5.009",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:emc_unity_xt_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A378F05-7F5D-4653-97F1-63DCB8F90EAF",
              "versionEndExcluding": "5.0.2.0.5.009",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:emc_unityvsa_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A6E8884-1DAC-4E5D-9BA9-5D89791691DB",
              "versionEndExcluding": "5.0.2.0.5.009",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell EMC Unity, Dell EMC Unity XT, and Dell EMC UnityVSA versions prior to 5.0.2.0.5.009 contain a Denial of Service vulnerability on NAS Server SSH implementation that is used to provide SFTP service on a NAS server. A remote unauthenticated attacker may potentially exploit this vulnerability and cause a Denial of Service (Storage Processor Panic) by sending an out of order SSH protocol sequence."
    },
    {
      "lang": "es",
      "value": "Dell EMC Unity, Dell EMC Unity XT, and Dell EMC UnityVSA versiones anteriores a 5.0.2.0.5.009, presentan una vulnerabilidad de Denegaci\u00f3n de Servicio en la implementaci\u00f3n SSH de NAS Server que es usado para proporcionar el servicio SFTP en un servidor NAS. Un atacante remoto no autenticado puede explotar potencialmente esta vulnerabilidad y causar una Denegaci\u00f3n de Servicio (P\u00e1nico en Procesador de Almacenamiento) mediante el env\u00edo de una secuencia de protocolo SSH fuera de orden."
    }
  ],
  "id": "CVE-2020-5319",
  "lastModified": "2024-11-21T05:33:54.223",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-02-06T18:15:13.887",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/security/en-us/details/540336/DSA-2020-019-Dell-EMC-Unity-Family-Dell-EMC-Unity-XT-Family-Denial-of-Service-Vulnerability"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/security/en-us/details/540336/DSA-2020-019-Dell-EMC-Unity-Family-Dell-EMC-Unity-XT-Family-Denial-of-Service-Vulnerability"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-129"
        }
      ],
      "source": "security_alert@emc.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-129"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2019-3754

Vulnerability from fkie_nvd - Published: 2019-09-03 17:15 - Updated: 2024-11-21 04:42
Summary
Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dell:emc_unity_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7091DD01-04E8-4560-BE2B-CC0F009C3D17",
              "versionEndExcluding": "5.0.0.0.5.116",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:emc_unityvsa_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAC14A15-77F9-4E6F-B900-6D3FBA241999",
              "versionEndExcluding": "5.0.0.0.5.116",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dell:emc_vnxe3200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61312D56-931F-488B-9563-2E1CBAF6F686",
              "versionEndExcluding": "3.1.10.9946299",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dell:emc_vnxe3200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E2FB19C-F28D-4D99-B965-85CEE552D981",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser."
    },
    {
      "lang": "es",
      "value": "Dell EMC Unity Operating Environment en versiones anteriores a la 5.0.0.0.5.116, Dell EMC UnityVSA en versiones anteriores a la 5.0.0.0.5.116 y Dell EMC VNXe3200 en versiones anteriores a la 3.1.10.9946299 contienen una vulnerabilidad de Cross-Site Scripting (XSS) reflejado en la p\u00e1gina cas/logout. Un atacante remoto no identificado podr\u00eda potencialmente aprovechar esta vulnerabilidad enga\u00f1ando a un usuario de una aplicaci\u00f3n v\u00edctima para que proporcione c\u00f3digo HTML o JavaScript malicioso a Unisphere, que se devuelve a la v\u00edctima y es ejecutado por el navegador web."
    }
  ],
  "id": "CVE-2019-3754",
  "lastModified": "2024-11-21T04:42:28.160",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 1.4,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-09-03T17:15:11.273",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "security_alert@emc.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2019-3741

Vulnerability from fkie_nvd - Published: 2019-07-18 16:15 - Updated: 2024-11-21 04:42
Summary
Dell EMC Unity and UnityVSA versions prior to 5.0.0.0.5.116 contain a plain-text password storage vulnerability. A Unisphere user’s (including the admin privilege user) password is stored in a plain text in Unity Data Collection bundle (logs files for troubleshooting). A local authenticated attacker with access to the Data Collection bundle may use the exposed password to gain access with the privileges of the compromised user.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dell:emc_unity_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7091DD01-04E8-4560-BE2B-CC0F009C3D17",
              "versionEndExcluding": "5.0.0.0.5.116",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:emc_unityvsa_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAC14A15-77F9-4E6F-B900-6D3FBA241999",
              "versionEndExcluding": "5.0.0.0.5.116",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell EMC Unity and UnityVSA versions prior to 5.0.0.0.5.116 contain a plain-text password storage vulnerability. A Unisphere user\u2019s (including the admin privilege user) password is stored in a plain text in Unity Data Collection bundle (logs files for troubleshooting). A local authenticated attacker with access to the Data Collection bundle may use the exposed password to gain access with the privileges of the compromised user."
    },
    {
      "lang": "es",
      "value": "Las versiones de Dell EMC Unity y UnityVSA anteriores a la versi\u00f3n 5.0.0.0.5.116 contienen una vulnerabilidad de almacenamiento de contrase\u00f1a de texto sin formato. La contrase\u00f1a de un usuario de Unisphere (incluido el usuario con privilegios de administrador) se almacena en un texto sin formato en el paquete de Unity Data Collection (archivos de registro para la resoluci\u00f3n de problemas). Un atacante autenticado local con acceso al paquete de recopilaci\u00f3n de datos puede usar la contrase\u00f1a expuesta para obtener acceso con los privilegios del usuario comprometido."
    }
  ],
  "id": "CVE-2019-3741",
  "lastModified": "2024-11-21T04:42:26.880",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 2.1,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-07-18T16:15:12.470",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "url": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "url": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-693"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2019-3734

Vulnerability from fkie_nvd - Published: 2019-07-18 16:15 - Updated: 2024-11-21 04:42
Summary
Dell EMC Unity and UnityVSA versions prior to 5.0.0.0.5.116 contain an improper authorization vulnerability in NAS Server quotas configuration. A remote authenticated Unisphere Operator could potentially exploit this vulnerability to edit quota configuration of other users.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dell:emc_unity_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7091DD01-04E8-4560-BE2B-CC0F009C3D17",
              "versionEndExcluding": "5.0.0.0.5.116",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:emc_unityvsa_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAC14A15-77F9-4E6F-B900-6D3FBA241999",
              "versionEndExcluding": "5.0.0.0.5.116",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell EMC Unity and UnityVSA versions prior to 5.0.0.0.5.116 contain an improper authorization vulnerability in NAS Server quotas configuration. A remote authenticated Unisphere Operator could potentially exploit this vulnerability to edit quota configuration of other users."
    },
    {
      "lang": "es",
      "value": "Las versiones de Dell EMC Unity y UnityVSA anteriores a 5.0.0.0.5.116 contienen una vulnerabilidad de autorizaci\u00f3n inadecuada en la configuraci\u00f3n de cuotas del servidor NAS. Un Operador de Unisphere autenticado a distancia podr\u00eda potencialmente explotar esta vulnerabilidad para editar la configuraci\u00f3n de cuotas de otros usuarios."
    }
  ],
  "id": "CVE-2019-3734",
  "lastModified": "2024-11-21T04:42:25.807",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 4.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 5.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
          "version": "3.0"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.5,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-07-18T16:15:12.390",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "url": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "url": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2018-11064

Vulnerability from fkie_nvd - Published: 2018-10-05 21:29 - Updated: 2024-11-21 03:42
Summary
Dell EMC Unity OE versions 4.3.0.x and 4.3.1.x and UnityVSA OE versions 4.3.0.x and 4.3.1.x contains an Incorrect File Permissions vulnerability. A locally authenticated malicious user could potentially exploit this vulnerability to alter multiple library files in service tools that might result in arbitrary code execution with elevated privileges. No user file systems are directly affected by this vulnerability.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dell:emc_unity_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F2560A8-0636-4902-A476-CF9B58619A49",
              "versionEndIncluding": "4.3.1.1525703027",
              "versionStartIncluding": "4.3.0.1522077968",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:dell:emc_unityvsa_operating_environment:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5EC48046-98E6-454B-86DF-C2316605E4C6",
              "versionEndIncluding": "4.3.1.1525703027",
              "versionStartIncluding": "4.3.0.1522077968",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell EMC Unity OE versions 4.3.0.x and 4.3.1.x and UnityVSA OE versions 4.3.0.x and 4.3.1.x contains an Incorrect File Permissions vulnerability. A locally authenticated malicious user could potentially exploit this vulnerability to alter multiple library files in service tools that might result in arbitrary code execution with elevated privileges. No user file systems are directly affected by this vulnerability."
    },
    {
      "lang": "es",
      "value": "Dell EMC Unity OE en versiones 4.3.0.x y 4.3.1.x y UnityVSA OE en versiones 4.3.0.x y 4.3.1.x contienen una vulnerabilidad de permisos de archivo incorrectos. Un usuario malicioso autenticado localmente podr\u00eda explotar esta vulnerabilidad para alterar m\u00faltiples archivos en las herramientas del servicio, lo que podr\u00eda resultar en la ejecuci\u00f3n de c\u00f3digo arbitrario con privilegios elevados. Ning\u00fan sistema de archivos del usuario se ve directamente afectado por esta vulnerabilidad."
    }
  ],
  "id": "CVE-2018-11064",
  "lastModified": "2024-11-21T03:42:36.360",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-10-05T21:29:00.387",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/105447"
    },
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://seclists.org/fulldisclosure/2018/Sep/55"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/105447"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://seclists.org/fulldisclosure/2018/Sep/55"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-732"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2022-22564 (GCVE-0-2022-22564)

Vulnerability from cvelistv5 – Published: 2023-02-14 15:34 – Updated: 2025-03-20 14:07
VLAI?
Summary
Dell EMC Unity versions before 5.2.0.0.5.173 , use(es) broken cryptographic algorithm. A remote unauthenticated attacker could potentially exploit this vulnerability by performing MitM attacks and let attackers obtain sensitive information.
CWE
  • CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: 0 , < 5.2.0.0.5.173 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.809Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000199050/dsa-2022-021-dell-unity-dell-unityvsa-and-dell-unity-xt-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-22564",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-20T14:06:54.221204Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-20T14:07:01.410Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.2.0.0.5.173",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-04-29T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell EMC Unity versions before 5.2.0.0.5.173 , use(es) broken cryptographic algorithm. A remote unauthenticated attacker could potentially exploit this vulnerability by performing MitM attacks and let attackers obtain sensitive information.\u003c/span\u003e\n\n"
            }
          ],
          "value": "Dell EMC Unity versions before 5.2.0.0.5.173 , use(es) broken cryptographic algorithm. A remote unauthenticated attacker could potentially exploit this vulnerability by performing MitM attacks and let attackers obtain sensitive information.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-327",
              "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-14T15:41:58.721Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000199050/dsa-2022-021-dell-unity-dell-unityvsa-and-dell-unity-xt-security-update-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2022-22564",
    "datePublished": "2023-02-14T15:34:09.480Z",
    "dateReserved": "2022-01-04T17:22:21.333Z",
    "dateUpdated": "2025-03-20T14:07:01.410Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-43589 (GCVE-0-2021-43589)

Vulnerability from cvelistv5 – Published: 2022-01-24 20:10 – Updated: 2024-09-17 00:21
VLAI?
Summary
Dell EMC Unity, Dell EMC UnityVSA and Dell EMC Unity XT versions prior to 5.1.2.0.5.007 contain an operating system (OS) command injection Vulnerability. A locally authenticated user with high privileges may potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the Unity underlying OS, with the privileges of the vulnerable application. Exploitation may lead to an elevation of privilege.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.1.2.0.5.007 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.414Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.2.0.5.007",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-12-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Dell EMC UnityVSA and Dell EMC Unity XT versions prior to 5.1.2.0.5.007 contain an operating system (OS) command injection Vulnerability. A locally authenticated user with high privileges may potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the Unity underlying OS, with the privileges of the vulnerable application. Exploitation may lead to an elevation of privilege."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-24T20:10:23",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-12-29",
          "ID": "CVE-2021-43589",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.2.0.5.007"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Dell EMC UnityVSA and Dell EMC Unity XT versions prior to 5.1.2.0.5.007 contain an operating system (OS) command injection Vulnerability. A locally authenticated user with high privileges may potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the Unity underlying OS, with the privileges of the vulnerable application. Exploitation may lead to an elevation of privilege."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-43589",
    "datePublished": "2022-01-24T20:10:23.923128Z",
    "dateReserved": "2021-11-12T00:00:00",
    "dateUpdated": "2024-09-17T00:21:04.462Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21591 (GCVE-0-2021-21591)

Vulnerability from cvelistv5 – Published: 2021-07-12 15:40 – Updated: 2024-09-17 03:48
VLAI?
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user.
CWE
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.1.0.0.5.394 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.465Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000189204"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.0.0.5.394",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-07-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-12T15:40:18",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000189204"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-07-01",
          "ID": "CVE-2021-21591",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.0.0.5.394"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.4,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200: Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000189204",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000189204"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21591",
    "datePublished": "2021-07-12T15:40:18.944714Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-17T03:48:49.687Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21590 (GCVE-0-2021-21590)

Vulnerability from cvelistv5 – Published: 2021-07-12 15:40 – Updated: 2024-09-16 20:57
VLAI?
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user.
CWE
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.1.0.0.5.394 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.608Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000189204"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.0.0.5.394",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-07-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-12T15:40:17",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000189204"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-07-01",
          "ID": "CVE-2021-21590",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.0.0.5.394"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.4,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200: Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000189204",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000189204"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21590",
    "datePublished": "2021-07-12T15:40:17.409613Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-16T20:57:44.496Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21589 (GCVE-0-2021-21589)

Vulnerability from cvelistv5 – Published: 2021-07-12 15:40 – Updated: 2024-09-17 03:58
VLAI?
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 do not exit on failed Initialization. A local authenticated Service user could potentially exploit this vulnerability to escalate privileges.
CWE
  • Other
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.1.0.0.5.394 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.651Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000189204"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.0.0.5.394",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-07-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 do not exit on failed Initialization. A local authenticated Service user could potentially exploit this vulnerability to escalate privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Other",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-12T15:40:15",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000189204"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-07-01",
          "ID": "CVE-2021-21589",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.0.0.5.394"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 do not exit on failed Initialization. A local authenticated Service user could potentially exploit this vulnerability to escalate privileges."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 5.7,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000189204",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000189204"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21589",
    "datePublished": "2021-07-12T15:40:15.913458Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-17T03:58:38.925Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-5319 (GCVE-0-2020-5319)

Vulnerability from cvelistv5 – Published: 2020-02-06 17:45 – Updated: 2024-09-16 20:27
VLAI?
Summary
Dell EMC Unity, Dell EMC Unity XT, and Dell EMC UnityVSA versions prior to 5.0.2.0.5.009 contain a Denial of Service vulnerability on NAS Server SSH implementation that is used to provide SFTP service on a NAS server. A remote unauthenticated attacker may potentially exploit this vulnerability and cause a Denial of Service (Storage Processor Panic) by sending an out of order SSH protocol sequence.
CWE
  • CWE-129 - Improper Validation of Array Index
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.0.2.0.5.009 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:22:09.229Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/security/en-us/details/540336/DSA-2020-019-Dell-EMC-Unity-Family-Dell-EMC-Unity-XT-Family-Denial-of-Service-Vulnerability"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.0.2.0.5.009",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-01-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Dell EMC Unity XT, and Dell EMC UnityVSA versions prior to 5.0.2.0.5.009 contain a Denial of Service vulnerability on NAS Server SSH implementation that is used to provide SFTP service on a NAS server. A remote unauthenticated attacker may potentially exploit this vulnerability and cause a Denial of Service (Storage Processor Panic) by sending an out of order SSH protocol sequence."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-129",
              "description": "CWE-129: Improper Validation of Array Index",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-06T17:45:22",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/security/en-us/details/540336/DSA-2020-019-Dell-EMC-Unity-Family-Dell-EMC-Unity-XT-Family-Denial-of-Service-Vulnerability"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2020-01-20",
          "ID": "CVE-2020-5319",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.0.2.0.5.009"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Dell EMC Unity XT, and Dell EMC UnityVSA versions prior to 5.0.2.0.5.009 contain a Denial of Service vulnerability on NAS Server SSH implementation that is used to provide SFTP service on a NAS server. A remote unauthenticated attacker may potentially exploit this vulnerability and cause a Denial of Service (Storage Processor Panic) by sending an out of order SSH protocol sequence."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.5,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-129: Improper Validation of Array Index"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/security/en-us/details/540336/DSA-2020-019-Dell-EMC-Unity-Family-Dell-EMC-Unity-XT-Family-Denial-of-Service-Vulnerability",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/security/en-us/details/540336/DSA-2020-019-Dell-EMC-Unity-Family-Dell-EMC-Unity-XT-Family-Denial-of-Service-Vulnerability"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2020-5319",
    "datePublished": "2020-02-06T17:45:22.225221Z",
    "dateReserved": "2020-01-03T00:00:00",
    "dateUpdated": "2024-09-16T20:27:11.870Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-3754 (GCVE-0-2019-3754)

Vulnerability from cvelistv5 – Published: 2019-09-03 16:52 – Updated: 2024-09-17 02:00
VLAI?
Summary
Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser.
CWE
  • CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
Vendor Product Version
DELL EMC Unity Operating Environment Affected: unspecified , < 5.0.0.0.5.116 (custom)
Create a notification for this product.
    DELL EMC UnityVSA Operating Environment Affected: unspecified , < 5.0.0.0.5.116 (custom)
Create a notification for this product.
    DELL EMC VNXe3200 Operating Environment Affected: unspecified , < 3.1.10.9946299 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:19:18.181Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity Operating Environment",
          "vendor": "DELL EMC",
          "versions": [
            {
              "lessThan": "5.0.0.0.5.116",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "UnityVSA Operating Environment",
          "vendor": "DELL EMC",
          "versions": [
            {
              "lessThan": "5.0.0.0.5.116",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "VNXe3200 Operating Environment",
          "vendor": "DELL EMC",
          "versions": [
            {
              "lessThan": "3.1.10.9946299",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-08-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-09-03T16:52:53",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2019-08-27T16:00:00.000Z",
          "ID": "CVE-2019-3754",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity Operating Environment",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.0.0.0.5.116"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "UnityVSA Operating Environment",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.0.0.0.5.116"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "VNXe3200 Operating Environment",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "3.1.10.9946299"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "DELL EMC"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability",
              "refsource": "CONFIRM",
              "url": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2019-3754",
    "datePublished": "2019-09-03T16:52:53.915317Z",
    "dateReserved": "2019-01-03T00:00:00",
    "dateUpdated": "2024-09-17T02:00:48.399Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-3741 (GCVE-0-2019-3741)

Vulnerability from cvelistv5 – Published: 2019-07-18 15:47 – Updated: 2024-09-16 19:29
VLAI?
Summary
Dell EMC Unity and UnityVSA versions prior to 5.0.0.0.5.116 contain a plain-text password storage vulnerability. A Unisphere user’s (including the admin privilege user) password is stored in a plain text in Unity Data Collection bundle (logs files for troubleshooting). A local authenticated attacker with access to the Data Collection bundle may use the exposed password to gain access with the privileges of the compromised user.
CWE
  • Plain-text Password Storage Vulnerability
Assigner
References
Impacted products
Vendor Product Version
DELL EMC Unity Affected: 5.0 , < 5.0.0.0.5.116 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:19:18.340Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "DELL EMC",
          "versions": [
            {
              "lessThan": "5.0.0.0.5.116",
              "status": "affected",
              "version": "5.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-06-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity and UnityVSA versions prior to 5.0.0.0.5.116 contain a plain-text password storage vulnerability. A Unisphere user\u2019s (including the admin privilege user) password is stored in a plain text in Unity Data Collection bundle (logs files for troubleshooting). A local authenticated attacker with access to the Data Collection bundle may use the exposed password to gain access with the privileges of the compromised user."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Plain-text Password Storage Vulnerability",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-07-18T15:47:00",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2019-06-27T16:00:00.000Z",
          "ID": "CVE-2019-3741",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.0",
                            "version_value": "5.0.0.0.5.116"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "DELL EMC"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity and UnityVSA versions prior to 5.0.0.0.5.116 contain a plain-text password storage vulnerability. A Unisphere user\u2019s (including the admin privilege user) password is stored in a plain text in Unity Data Collection bundle (logs files for troubleshooting). A local authenticated attacker with access to the Data Collection bundle may use the exposed password to gain access with the privileges of the compromised user."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Plain-text Password Storage Vulnerability"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities",
              "refsource": "MISC",
              "url": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2019-3741",
    "datePublished": "2019-07-18T15:47:00.171821Z",
    "dateReserved": "2019-01-03T00:00:00",
    "dateUpdated": "2024-09-16T19:29:55.995Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-3734 (GCVE-0-2019-3734)

Vulnerability from cvelistv5 – Published: 2019-07-18 15:47 – Updated: 2024-09-16 20:27
VLAI?
Summary
Dell EMC Unity and UnityVSA versions prior to 5.0.0.0.5.116 contain an improper authorization vulnerability in NAS Server quotas configuration. A remote authenticated Unisphere Operator could potentially exploit this vulnerability to edit quota configuration of other users.
CWE
  • Improper Authorization Vulnerability
Assigner
References
Impacted products
Vendor Product Version
DELL EMC Unity Affected: 5.0 , < 5.0.0.0.5.116 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:19:18.329Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "DELL EMC",
          "versions": [
            {
              "lessThan": "5.0.0.0.5.116",
              "status": "affected",
              "version": "5.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-06-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity and UnityVSA versions prior to 5.0.0.0.5.116 contain an improper authorization vulnerability in NAS Server quotas configuration. A remote authenticated Unisphere Operator could potentially exploit this vulnerability to edit quota configuration of other users."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Improper Authorization Vulnerability",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-07-18T15:47:00",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2019-06-27T16:00:00.000Z",
          "ID": "CVE-2019-3734",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.0",
                            "version_value": "5.0.0.0.5.116"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "DELL EMC"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity and UnityVSA versions prior to 5.0.0.0.5.116 contain an improper authorization vulnerability in NAS Server quotas configuration. A remote authenticated Unisphere Operator could potentially exploit this vulnerability to edit quota configuration of other users."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Authorization Vulnerability"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities",
              "refsource": "MISC",
              "url": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2019-3734",
    "datePublished": "2019-07-18T15:47:00.111450Z",
    "dateReserved": "2019-01-03T00:00:00",
    "dateUpdated": "2024-09-16T20:27:42.264Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-11064 (GCVE-0-2018-11064)

Vulnerability from cvelistv5 – Published: 2018-10-05 21:00 – Updated: 2024-09-16 22:55
VLAI?
Summary
Dell EMC Unity OE versions 4.3.0.x and 4.3.1.x and UnityVSA OE versions 4.3.0.x and 4.3.1.x contains an Incorrect File Permissions vulnerability. A locally authenticated malicious user could potentially exploit this vulnerability to alter multiple library files in service tools that might result in arbitrary code execution with elevated privileges. No user file systems are directly affected by this vulnerability.
CWE
  • Incorrect File Permissions
Assigner
References
https://seclists.org/fulldisclosure/2018/Sep/55 mailing-listx_refsource_FULLDISC
http://www.securityfocus.com/bid/105447 vdb-entryx_refsource_BID
Impacted products
Vendor Product Version
Dell EMC Dell EMC Unity Affected: 4.3.0.x , ≤ 4.3.1.x (custom)
Create a notification for this product.
    Dell EMC Dell EMC UnityVSA Affected: 4.3.0.x , ≤ 4.3.1.x (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:54:36.559Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20180926 DSA-2018-141: Dell EMC Unity Family Incorrect File Permissions vulnerability",
            "tags": [
              "mailing-list",
              "x_refsource_FULLDISC",
              "x_transferred"
            ],
            "url": "https://seclists.org/fulldisclosure/2018/Sep/55"
          },
          {
            "name": "105447",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105447"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Dell EMC Unity",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThanOrEqual": "4.3.1.x",
              "status": "affected",
              "version": "4.3.0.x",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Dell EMC UnityVSA",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThanOrEqual": "4.3.1.x",
              "status": "affected",
              "version": "4.3.0.x",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2018-09-28T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity OE versions 4.3.0.x and 4.3.1.x and UnityVSA OE versions 4.3.0.x and 4.3.1.x contains an Incorrect File Permissions vulnerability. A locally authenticated malicious user could potentially exploit this vulnerability to alter multiple library files in service tools that might result in arbitrary code execution with elevated privileges. No user file systems are directly affected by this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Incorrect File Permissions",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-07T09:57:02",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "name": "20180926 DSA-2018-141: Dell EMC Unity Family Incorrect File Permissions vulnerability",
          "tags": [
            "mailing-list",
            "x_refsource_FULLDISC"
          ],
          "url": "https://seclists.org/fulldisclosure/2018/Sep/55"
        },
        {
          "name": "105447",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105447"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security_alert@emc.com",
          "DATE_PUBLIC": "2018-09-28T05:00:00.000Z",
          "ID": "CVE-2018-11064",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Dell EMC Unity",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c=",
                            "version_affected": "\u003c=",
                            "version_name": "4.3.0.x",
                            "version_value": "4.3.1.x"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Dell EMC UnityVSA",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c=",
                            "version_affected": "\u003c=",
                            "version_name": "4.3.0.x",
                            "version_value": "4.3.1.x"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell EMC"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity OE versions 4.3.0.x and 4.3.1.x and UnityVSA OE versions 4.3.0.x and 4.3.1.x contains an Incorrect File Permissions vulnerability. A locally authenticated malicious user could potentially exploit this vulnerability to alter multiple library files in service tools that might result in arbitrary code execution with elevated privileges. No user file systems are directly affected by this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Incorrect File Permissions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20180926 DSA-2018-141: Dell EMC Unity Family Incorrect File Permissions vulnerability",
              "refsource": "FULLDISC",
              "url": "https://seclists.org/fulldisclosure/2018/Sep/55"
            },
            {
              "name": "105447",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105447"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2018-11064",
    "datePublished": "2018-10-05T21:00:00Z",
    "dateReserved": "2018-05-14T00:00:00",
    "dateUpdated": "2024-09-16T22:55:44.290Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-22564 (GCVE-0-2022-22564)

Vulnerability from nvd – Published: 2023-02-14 15:34 – Updated: 2025-03-20 14:07
VLAI?
Summary
Dell EMC Unity versions before 5.2.0.0.5.173 , use(es) broken cryptographic algorithm. A remote unauthenticated attacker could potentially exploit this vulnerability by performing MitM attacks and let attackers obtain sensitive information.
CWE
  • CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: 0 , < 5.2.0.0.5.173 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.809Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000199050/dsa-2022-021-dell-unity-dell-unityvsa-and-dell-unity-xt-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-22564",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-20T14:06:54.221204Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-20T14:07:01.410Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.2.0.0.5.173",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-04-29T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell EMC Unity versions before 5.2.0.0.5.173 , use(es) broken cryptographic algorithm. A remote unauthenticated attacker could potentially exploit this vulnerability by performing MitM attacks and let attackers obtain sensitive information.\u003c/span\u003e\n\n"
            }
          ],
          "value": "Dell EMC Unity versions before 5.2.0.0.5.173 , use(es) broken cryptographic algorithm. A remote unauthenticated attacker could potentially exploit this vulnerability by performing MitM attacks and let attackers obtain sensitive information.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-327",
              "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-14T15:41:58.721Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000199050/dsa-2022-021-dell-unity-dell-unityvsa-and-dell-unity-xt-security-update-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2022-22564",
    "datePublished": "2023-02-14T15:34:09.480Z",
    "dateReserved": "2022-01-04T17:22:21.333Z",
    "dateUpdated": "2025-03-20T14:07:01.410Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-43589 (GCVE-0-2021-43589)

Vulnerability from nvd – Published: 2022-01-24 20:10 – Updated: 2024-09-17 00:21
VLAI?
Summary
Dell EMC Unity, Dell EMC UnityVSA and Dell EMC Unity XT versions prior to 5.1.2.0.5.007 contain an operating system (OS) command injection Vulnerability. A locally authenticated user with high privileges may potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the Unity underlying OS, with the privileges of the vulnerable application. Exploitation may lead to an elevation of privilege.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.1.2.0.5.007 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.414Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.2.0.5.007",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-12-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Dell EMC UnityVSA and Dell EMC Unity XT versions prior to 5.1.2.0.5.007 contain an operating system (OS) command injection Vulnerability. A locally authenticated user with high privileges may potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the Unity underlying OS, with the privileges of the vulnerable application. Exploitation may lead to an elevation of privilege."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-24T20:10:23",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-12-29",
          "ID": "CVE-2021-43589",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.2.0.5.007"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Dell EMC UnityVSA and Dell EMC Unity XT versions prior to 5.1.2.0.5.007 contain an operating system (OS) command injection Vulnerability. A locally authenticated user with high privileges may potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the Unity underlying OS, with the privileges of the vulnerable application. Exploitation may lead to an elevation of privilege."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000194836/dsa-2021-271-dell-emc-unity-dell-emc-unity-vsa-and-dell-emc-unity-xt-security-update-for-multiple-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-43589",
    "datePublished": "2022-01-24T20:10:23.923128Z",
    "dateReserved": "2021-11-12T00:00:00",
    "dateUpdated": "2024-09-17T00:21:04.462Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21591 (GCVE-0-2021-21591)

Vulnerability from nvd – Published: 2021-07-12 15:40 – Updated: 2024-09-17 03:48
VLAI?
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user.
CWE
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.1.0.0.5.394 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.465Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000189204"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.0.0.5.394",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-07-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-12T15:40:18",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000189204"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-07-01",
          "ID": "CVE-2021-21591",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.0.0.5.394"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.4,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200: Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000189204",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000189204"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21591",
    "datePublished": "2021-07-12T15:40:18.944714Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-17T03:48:49.687Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21590 (GCVE-0-2021-21590)

Vulnerability from nvd – Published: 2021-07-12 15:40 – Updated: 2024-09-16 20:57
VLAI?
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user.
CWE
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.1.0.0.5.394 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.608Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000189204"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.0.0.5.394",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-07-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-12T15:40:17",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000189204"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-07-01",
          "ID": "CVE-2021-21590",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.0.0.5.394"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.4,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200: Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000189204",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000189204"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21590",
    "datePublished": "2021-07-12T15:40:17.409613Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-16T20:57:44.496Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21589 (GCVE-0-2021-21589)

Vulnerability from nvd – Published: 2021-07-12 15:40 – Updated: 2024-09-17 03:58
VLAI?
Summary
Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 do not exit on failed Initialization. A local authenticated Service user could potentially exploit this vulnerability to escalate privileges.
CWE
  • Other
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.1.0.0.5.394 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.651Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000189204"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.1.0.0.5.394",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-07-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 do not exit on failed Initialization. A local authenticated Service user could potentially exploit this vulnerability to escalate privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Other",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-12T15:40:15",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000189204"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-07-01",
          "ID": "CVE-2021-21589",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.0.0.5.394"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 do not exit on failed Initialization. A local authenticated Service user could potentially exploit this vulnerability to escalate privileges."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 5.7,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000189204",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000189204"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21589",
    "datePublished": "2021-07-12T15:40:15.913458Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-17T03:58:38.925Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-5319 (GCVE-0-2020-5319)

Vulnerability from nvd – Published: 2020-02-06 17:45 – Updated: 2024-09-16 20:27
VLAI?
Summary
Dell EMC Unity, Dell EMC Unity XT, and Dell EMC UnityVSA versions prior to 5.0.2.0.5.009 contain a Denial of Service vulnerability on NAS Server SSH implementation that is used to provide SFTP service on a NAS server. A remote unauthenticated attacker may potentially exploit this vulnerability and cause a Denial of Service (Storage Processor Panic) by sending an out of order SSH protocol sequence.
CWE
  • CWE-129 - Improper Validation of Array Index
Assigner
References
Impacted products
Vendor Product Version
Dell Unity Affected: unspecified , < 5.0.2.0.5.009 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:22:09.229Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/security/en-us/details/540336/DSA-2020-019-Dell-EMC-Unity-Family-Dell-EMC-Unity-XT-Family-Denial-of-Service-Vulnerability"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.0.2.0.5.009",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-01-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity, Dell EMC Unity XT, and Dell EMC UnityVSA versions prior to 5.0.2.0.5.009 contain a Denial of Service vulnerability on NAS Server SSH implementation that is used to provide SFTP service on a NAS server. A remote unauthenticated attacker may potentially exploit this vulnerability and cause a Denial of Service (Storage Processor Panic) by sending an out of order SSH protocol sequence."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-129",
              "description": "CWE-129: Improper Validation of Array Index",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-06T17:45:22",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/security/en-us/details/540336/DSA-2020-019-Dell-EMC-Unity-Family-Dell-EMC-Unity-XT-Family-Denial-of-Service-Vulnerability"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2020-01-20",
          "ID": "CVE-2020-5319",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.0.2.0.5.009"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity, Dell EMC Unity XT, and Dell EMC UnityVSA versions prior to 5.0.2.0.5.009 contain a Denial of Service vulnerability on NAS Server SSH implementation that is used to provide SFTP service on a NAS server. A remote unauthenticated attacker may potentially exploit this vulnerability and cause a Denial of Service (Storage Processor Panic) by sending an out of order SSH protocol sequence."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.5,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-129: Improper Validation of Array Index"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/security/en-us/details/540336/DSA-2020-019-Dell-EMC-Unity-Family-Dell-EMC-Unity-XT-Family-Denial-of-Service-Vulnerability",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/security/en-us/details/540336/DSA-2020-019-Dell-EMC-Unity-Family-Dell-EMC-Unity-XT-Family-Denial-of-Service-Vulnerability"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2020-5319",
    "datePublished": "2020-02-06T17:45:22.225221Z",
    "dateReserved": "2020-01-03T00:00:00",
    "dateUpdated": "2024-09-16T20:27:11.870Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-3754 (GCVE-0-2019-3754)

Vulnerability from nvd – Published: 2019-09-03 16:52 – Updated: 2024-09-17 02:00
VLAI?
Summary
Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser.
CWE
  • CWE-79 - Cross-site Scripting (XSS)
Assigner
References
Impacted products
Vendor Product Version
DELL EMC Unity Operating Environment Affected: unspecified , < 5.0.0.0.5.116 (custom)
Create a notification for this product.
    DELL EMC UnityVSA Operating Environment Affected: unspecified , < 5.0.0.0.5.116 (custom)
Create a notification for this product.
    DELL EMC VNXe3200 Operating Environment Affected: unspecified , < 3.1.10.9946299 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:19:18.181Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity Operating Environment",
          "vendor": "DELL EMC",
          "versions": [
            {
              "lessThan": "5.0.0.0.5.116",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "UnityVSA Operating Environment",
          "vendor": "DELL EMC",
          "versions": [
            {
              "lessThan": "5.0.0.0.5.116",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "VNXe3200 Operating Environment",
          "vendor": "DELL EMC",
          "versions": [
            {
              "lessThan": "3.1.10.9946299",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-08-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-09-03T16:52:53",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2019-08-27T16:00:00.000Z",
          "ID": "CVE-2019-3754",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity Operating Environment",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.0.0.0.5.116"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "UnityVSA Operating Environment",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.0.0.0.5.116"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "VNXe3200 Operating Environment",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "3.1.10.9946299"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "DELL EMC"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability",
              "refsource": "CONFIRM",
              "url": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2019-3754",
    "datePublished": "2019-09-03T16:52:53.915317Z",
    "dateReserved": "2019-01-03T00:00:00",
    "dateUpdated": "2024-09-17T02:00:48.399Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-3741 (GCVE-0-2019-3741)

Vulnerability from nvd – Published: 2019-07-18 15:47 – Updated: 2024-09-16 19:29
VLAI?
Summary
Dell EMC Unity and UnityVSA versions prior to 5.0.0.0.5.116 contain a plain-text password storage vulnerability. A Unisphere user’s (including the admin privilege user) password is stored in a plain text in Unity Data Collection bundle (logs files for troubleshooting). A local authenticated attacker with access to the Data Collection bundle may use the exposed password to gain access with the privileges of the compromised user.
CWE
  • Plain-text Password Storage Vulnerability
Assigner
References
Impacted products
Vendor Product Version
DELL EMC Unity Affected: 5.0 , < 5.0.0.0.5.116 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:19:18.340Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "DELL EMC",
          "versions": [
            {
              "lessThan": "5.0.0.0.5.116",
              "status": "affected",
              "version": "5.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-06-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity and UnityVSA versions prior to 5.0.0.0.5.116 contain a plain-text password storage vulnerability. A Unisphere user\u2019s (including the admin privilege user) password is stored in a plain text in Unity Data Collection bundle (logs files for troubleshooting). A local authenticated attacker with access to the Data Collection bundle may use the exposed password to gain access with the privileges of the compromised user."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Plain-text Password Storage Vulnerability",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-07-18T15:47:00",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2019-06-27T16:00:00.000Z",
          "ID": "CVE-2019-3741",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.0",
                            "version_value": "5.0.0.0.5.116"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "DELL EMC"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity and UnityVSA versions prior to 5.0.0.0.5.116 contain a plain-text password storage vulnerability. A Unisphere user\u2019s (including the admin privilege user) password is stored in a plain text in Unity Data Collection bundle (logs files for troubleshooting). A local authenticated attacker with access to the Data Collection bundle may use the exposed password to gain access with the privileges of the compromised user."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Plain-text Password Storage Vulnerability"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities",
              "refsource": "MISC",
              "url": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2019-3741",
    "datePublished": "2019-07-18T15:47:00.171821Z",
    "dateReserved": "2019-01-03T00:00:00",
    "dateUpdated": "2024-09-16T19:29:55.995Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-3734 (GCVE-0-2019-3734)

Vulnerability from nvd – Published: 2019-07-18 15:47 – Updated: 2024-09-16 20:27
VLAI?
Summary
Dell EMC Unity and UnityVSA versions prior to 5.0.0.0.5.116 contain an improper authorization vulnerability in NAS Server quotas configuration. A remote authenticated Unisphere Operator could potentially exploit this vulnerability to edit quota configuration of other users.
CWE
  • Improper Authorization Vulnerability
Assigner
References
Impacted products
Vendor Product Version
DELL EMC Unity Affected: 5.0 , < 5.0.0.0.5.116 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:19:18.329Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity",
          "vendor": "DELL EMC",
          "versions": [
            {
              "lessThan": "5.0.0.0.5.116",
              "status": "affected",
              "version": "5.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-06-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity and UnityVSA versions prior to 5.0.0.0.5.116 contain an improper authorization vulnerability in NAS Server quotas configuration. A remote authenticated Unisphere Operator could potentially exploit this vulnerability to edit quota configuration of other users."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Improper Authorization Vulnerability",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-07-18T15:47:00",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2019-06-27T16:00:00.000Z",
          "ID": "CVE-2019-3734",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.0",
                            "version_value": "5.0.0.0.5.116"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "DELL EMC"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity and UnityVSA versions prior to 5.0.0.0.5.116 contain an improper authorization vulnerability in NAS Server quotas configuration. A remote authenticated Unisphere Operator could potentially exploit this vulnerability to edit quota configuration of other users."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Authorization Vulnerability"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities",
              "refsource": "MISC",
              "url": "https://productsecurity-ux.ausmp1z1.pcf.dell.com/support/security/us/en/04/details/535028/DSA-2019-086-Dell-EMC-Unity-Family-Multiple-Vulnerabilities"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2019-3734",
    "datePublished": "2019-07-18T15:47:00.111450Z",
    "dateReserved": "2019-01-03T00:00:00",
    "dateUpdated": "2024-09-16T20:27:42.264Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-11064 (GCVE-0-2018-11064)

Vulnerability from nvd – Published: 2018-10-05 21:00 – Updated: 2024-09-16 22:55
VLAI?
Summary
Dell EMC Unity OE versions 4.3.0.x and 4.3.1.x and UnityVSA OE versions 4.3.0.x and 4.3.1.x contains an Incorrect File Permissions vulnerability. A locally authenticated malicious user could potentially exploit this vulnerability to alter multiple library files in service tools that might result in arbitrary code execution with elevated privileges. No user file systems are directly affected by this vulnerability.
CWE
  • Incorrect File Permissions
Assigner
References
https://seclists.org/fulldisclosure/2018/Sep/55 mailing-listx_refsource_FULLDISC
http://www.securityfocus.com/bid/105447 vdb-entryx_refsource_BID
Impacted products
Vendor Product Version
Dell EMC Dell EMC Unity Affected: 4.3.0.x , ≤ 4.3.1.x (custom)
Create a notification for this product.
    Dell EMC Dell EMC UnityVSA Affected: 4.3.0.x , ≤ 4.3.1.x (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:54:36.559Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20180926 DSA-2018-141: Dell EMC Unity Family Incorrect File Permissions vulnerability",
            "tags": [
              "mailing-list",
              "x_refsource_FULLDISC",
              "x_transferred"
            ],
            "url": "https://seclists.org/fulldisclosure/2018/Sep/55"
          },
          {
            "name": "105447",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105447"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Dell EMC Unity",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThanOrEqual": "4.3.1.x",
              "status": "affected",
              "version": "4.3.0.x",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Dell EMC UnityVSA",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThanOrEqual": "4.3.1.x",
              "status": "affected",
              "version": "4.3.0.x",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2018-09-28T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unity OE versions 4.3.0.x and 4.3.1.x and UnityVSA OE versions 4.3.0.x and 4.3.1.x contains an Incorrect File Permissions vulnerability. A locally authenticated malicious user could potentially exploit this vulnerability to alter multiple library files in service tools that might result in arbitrary code execution with elevated privileges. No user file systems are directly affected by this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Incorrect File Permissions",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-07T09:57:02",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "name": "20180926 DSA-2018-141: Dell EMC Unity Family Incorrect File Permissions vulnerability",
          "tags": [
            "mailing-list",
            "x_refsource_FULLDISC"
          ],
          "url": "https://seclists.org/fulldisclosure/2018/Sep/55"
        },
        {
          "name": "105447",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105447"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security_alert@emc.com",
          "DATE_PUBLIC": "2018-09-28T05:00:00.000Z",
          "ID": "CVE-2018-11064",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Dell EMC Unity",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c=",
                            "version_affected": "\u003c=",
                            "version_name": "4.3.0.x",
                            "version_value": "4.3.1.x"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Dell EMC UnityVSA",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c=",
                            "version_affected": "\u003c=",
                            "version_name": "4.3.0.x",
                            "version_value": "4.3.1.x"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell EMC"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unity OE versions 4.3.0.x and 4.3.1.x and UnityVSA OE versions 4.3.0.x and 4.3.1.x contains an Incorrect File Permissions vulnerability. A locally authenticated malicious user could potentially exploit this vulnerability to alter multiple library files in service tools that might result in arbitrary code execution with elevated privileges. No user file systems are directly affected by this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Incorrect File Permissions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20180926 DSA-2018-141: Dell EMC Unity Family Incorrect File Permissions vulnerability",
              "refsource": "FULLDISC",
              "url": "https://seclists.org/fulldisclosure/2018/Sep/55"
            },
            {
              "name": "105447",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105447"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2018-11064",
    "datePublished": "2018-10-05T21:00:00Z",
    "dateReserved": "2018-05-14T00:00:00",
    "dateUpdated": "2024-09-16T22:55:44.290Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}