Search criteria

3 vulnerabilities found for go_1_firmware by unitree

FKIE_CVE-2022-2675

Vulnerability from fkie_nvd - Published: 2022-08-05 17:15 - Updated: 2024-11-21 07:01
Summary
Using off-the-shelf commodity hardware, the Unitree Go 1 robotics platform version H0.1.7 and H0.1.9 (using firmware version 0.1.35) can be powered down by an attacker within normal RF range without authentication. Other versions may be affected, such as the A1.
Impacted products
Vendor Product Version
unitree go_1_firmware *
unitree go_1 h0.1.7
unitree go_1_firmware *
unitree go_1 h0.1.9

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:unitree:go_1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C77CEE9-1D52-4232-B246-2DD22AB67164",
              "versionEndIncluding": "0.1.35",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:unitree:go_1:h0.1.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "D11F4C4B-BBC2-4DEF-B007-F4A41B63B73F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:unitree:go_1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "769D23CA-EB8D-47AB-BA82-80171020F1F2",
              "versionEndExcluding": "0.1.35",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:unitree:go_1:h0.1.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1B1F3C7-D3F5-4390-9C53-DFF17EE6DA3A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Using off-the-shelf commodity hardware, the Unitree Go 1 robotics platform version H0.1.7 and H0.1.9 (using firmware version 0.1.35) can be powered down by an attacker within normal RF range without authentication. Other versions may be affected, such as the A1."
    },
    {
      "lang": "es",
      "value": "Usando hardware comercial, la plataforma rob\u00f3tica Unitree Go 1 versiones H0.1.7 y H0.1.9 (usando la versi\u00f3n de firmware 0.1.35) puede ser apagada por un atacante dentro del rango normal de RF sin autenticaci\u00f3n. Otras versiones pueden estar afectadas, como la A1"
    }
  ],
  "id": "CVE-2022-2675",
  "lastModified": "2024-11-21T07:01:29.490",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-08-05T17:15:08.857",
  "references": [
    {
      "source": "cve@rapid7.com",
      "tags": [
        "Product",
        "Third Party Advisory"
      ],
      "url": "https://fccid.io/2A5PE-YUSHU001/Users-Manual/User-Manual-5810729"
    },
    {
      "source": "cve@rapid7.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://twitter.com/d0tslash/status/1555326302462394370"
    },
    {
      "source": "cve@rapid7.com",
      "tags": [
        "Product",
        "Third Party Advisory"
      ],
      "url": "https://www.mybotshop.de/Datasheet/Unitree_A1_User_Manual_v1.0.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Product",
        "Third Party Advisory"
      ],
      "url": "https://fccid.io/2A5PE-YUSHU001/Users-Manual/User-Manual-5810729"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://twitter.com/d0tslash/status/1555326302462394370"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Product",
        "Third Party Advisory"
      ],
      "url": "https://www.mybotshop.de/Datasheet/Unitree_A1_User_Manual_v1.0.pdf"
    }
  ],
  "sourceIdentifier": "cve@rapid7.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-285"
        }
      ],
      "source": "cve@rapid7.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2022-2675 (GCVE-0-2022-2675)

Vulnerability from cvelistv5 – Published: 2022-08-05 17:01 – Updated: 2024-09-16 16:33
VLAI?
Summary
Using off-the-shelf commodity hardware, the Unitree Go 1 robotics platform version H0.1.7 and H0.1.9 (using firmware version 0.1.35) can be powered down by an attacker within normal RF range without authentication. Other versions may be affected, such as the A1.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
Unitree Go 1 Affected: 0.1.35 , ≤ 0.1.35 (custom)
Create a notification for this product.
    Unitree Go 1 Affected: 0.1.35 , < 0.1.35 (custom)
Create a notification for this product.
Credits
Discovered and reported by security researcher Kevin Finisterre
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:46:03.432Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://twitter.com/d0tslash/status/1555326302462394370"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://fccid.io/2A5PE-YUSHU001/Users-Manual/User-Manual-5810729"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.mybotshop.de/Datasheet/Unitree_A1_User_Manual_v1.0.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "H0.1.7"
          ],
          "product": "Go 1",
          "vendor": "Unitree",
          "versions": [
            {
              "lessThanOrEqual": "0.1.35",
              "status": "affected",
              "version": "0.1.35",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "H0.1.9"
          ],
          "product": "Go 1",
          "vendor": "Unitree",
          "versions": [
            {
              "lessThan": "0.1.35",
              "status": "affected",
              "version": "0.1.35",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Discovered and reported by security researcher Kevin Finisterre"
        }
      ],
      "datePublic": "2022-08-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Using off-the-shelf commodity hardware, the Unitree Go 1 robotics platform version H0.1.7 and H0.1.9 (using firmware version 0.1.35) can be powered down by an attacker within normal RF range without authentication. Other versions may be affected, such as the A1."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-285",
              "description": "CWE-285 Improper Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-05T17:01:52",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://twitter.com/d0tslash/status/1555326302462394370"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://fccid.io/2A5PE-YUSHU001/Users-Manual/User-Manual-5810729"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.mybotshop.de/Datasheet/Unitree_A1_User_Manual_v1.0.pdf"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Unitree Go 1 \"Robot Dog\" Unauthenticated Remote Power Down",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "",
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2022-08-04T22:54:00.000Z",
          "ID": "CVE-2022-2675",
          "STATE": "PUBLIC",
          "TITLE": "Unitree Go 1 \"Robot Dog\" Unauthenticated Remote Power Down"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Go 1",
                      "version": {
                        "version_data": [
                          {
                            "platform": "H0.1.7",
                            "version_affected": "\u003c=",
                            "version_name": "0.1.35",
                            "version_value": "0.1.35"
                          },
                          {
                            "platform": "H0.1.9",
                            "version_affected": "\u003c",
                            "version_name": "0.1.35",
                            "version_value": "0.1.35"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Unitree"
              }
            ]
          }
        },
        "configuration": [],
        "credit": [
          {
            "lang": "eng",
            "value": "Discovered and reported by security researcher Kevin Finisterre"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Using off-the-shelf commodity hardware, the Unitree Go 1 robotics platform version H0.1.7 and H0.1.9 (using firmware version 0.1.35) can be powered down by an attacker within normal RF range without authentication. Other versions may be affected, such as the A1."
            }
          ]
        },
        "exploit": [],
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-285 Improper Authorization"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://twitter.com/d0tslash/status/1555326302462394370",
              "refsource": "MISC",
              "url": "https://twitter.com/d0tslash/status/1555326302462394370"
            },
            {
              "name": "https://fccid.io/2A5PE-YUSHU001/Users-Manual/User-Manual-5810729",
              "refsource": "MISC",
              "url": "https://fccid.io/2A5PE-YUSHU001/Users-Manual/User-Manual-5810729"
            },
            {
              "name": "https://www.mybotshop.de/Datasheet/Unitree_A1_User_Manual_v1.0.pdf",
              "refsource": "MISC",
              "url": "https://www.mybotshop.de/Datasheet/Unitree_A1_User_Manual_v1.0.pdf"
            }
          ]
        },
        "solution": [],
        "source": {
          "advisory": "",
          "defect": [],
          "discovery": "EXTERNAL"
        },
        "work_around": []
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2022-2675",
    "datePublished": "2022-08-05T17:01:52.182829Z",
    "dateReserved": "2022-08-05T00:00:00",
    "dateUpdated": "2024-09-16T16:33:04.349Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2675 (GCVE-0-2022-2675)

Vulnerability from nvd – Published: 2022-08-05 17:01 – Updated: 2024-09-16 16:33
VLAI?
Summary
Using off-the-shelf commodity hardware, the Unitree Go 1 robotics platform version H0.1.7 and H0.1.9 (using firmware version 0.1.35) can be powered down by an attacker within normal RF range without authentication. Other versions may be affected, such as the A1.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
Unitree Go 1 Affected: 0.1.35 , ≤ 0.1.35 (custom)
Create a notification for this product.
    Unitree Go 1 Affected: 0.1.35 , < 0.1.35 (custom)
Create a notification for this product.
Credits
Discovered and reported by security researcher Kevin Finisterre
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:46:03.432Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://twitter.com/d0tslash/status/1555326302462394370"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://fccid.io/2A5PE-YUSHU001/Users-Manual/User-Manual-5810729"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.mybotshop.de/Datasheet/Unitree_A1_User_Manual_v1.0.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "H0.1.7"
          ],
          "product": "Go 1",
          "vendor": "Unitree",
          "versions": [
            {
              "lessThanOrEqual": "0.1.35",
              "status": "affected",
              "version": "0.1.35",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "H0.1.9"
          ],
          "product": "Go 1",
          "vendor": "Unitree",
          "versions": [
            {
              "lessThan": "0.1.35",
              "status": "affected",
              "version": "0.1.35",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Discovered and reported by security researcher Kevin Finisterre"
        }
      ],
      "datePublic": "2022-08-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Using off-the-shelf commodity hardware, the Unitree Go 1 robotics platform version H0.1.7 and H0.1.9 (using firmware version 0.1.35) can be powered down by an attacker within normal RF range without authentication. Other versions may be affected, such as the A1."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-285",
              "description": "CWE-285 Improper Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-05T17:01:52",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://twitter.com/d0tslash/status/1555326302462394370"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://fccid.io/2A5PE-YUSHU001/Users-Manual/User-Manual-5810729"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.mybotshop.de/Datasheet/Unitree_A1_User_Manual_v1.0.pdf"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Unitree Go 1 \"Robot Dog\" Unauthenticated Remote Power Down",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "",
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2022-08-04T22:54:00.000Z",
          "ID": "CVE-2022-2675",
          "STATE": "PUBLIC",
          "TITLE": "Unitree Go 1 \"Robot Dog\" Unauthenticated Remote Power Down"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Go 1",
                      "version": {
                        "version_data": [
                          {
                            "platform": "H0.1.7",
                            "version_affected": "\u003c=",
                            "version_name": "0.1.35",
                            "version_value": "0.1.35"
                          },
                          {
                            "platform": "H0.1.9",
                            "version_affected": "\u003c",
                            "version_name": "0.1.35",
                            "version_value": "0.1.35"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Unitree"
              }
            ]
          }
        },
        "configuration": [],
        "credit": [
          {
            "lang": "eng",
            "value": "Discovered and reported by security researcher Kevin Finisterre"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Using off-the-shelf commodity hardware, the Unitree Go 1 robotics platform version H0.1.7 and H0.1.9 (using firmware version 0.1.35) can be powered down by an attacker within normal RF range without authentication. Other versions may be affected, such as the A1."
            }
          ]
        },
        "exploit": [],
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-285 Improper Authorization"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://twitter.com/d0tslash/status/1555326302462394370",
              "refsource": "MISC",
              "url": "https://twitter.com/d0tslash/status/1555326302462394370"
            },
            {
              "name": "https://fccid.io/2A5PE-YUSHU001/Users-Manual/User-Manual-5810729",
              "refsource": "MISC",
              "url": "https://fccid.io/2A5PE-YUSHU001/Users-Manual/User-Manual-5810729"
            },
            {
              "name": "https://www.mybotshop.de/Datasheet/Unitree_A1_User_Manual_v1.0.pdf",
              "refsource": "MISC",
              "url": "https://www.mybotshop.de/Datasheet/Unitree_A1_User_Manual_v1.0.pdf"
            }
          ]
        },
        "solution": [],
        "source": {
          "advisory": "",
          "defect": [],
          "discovery": "EXTERNAL"
        },
        "work_around": []
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2022-2675",
    "datePublished": "2022-08-05T17:01:52.182829Z",
    "dateReserved": "2022-08-05T00:00:00",
    "dateUpdated": "2024-09-16T16:33:04.349Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}