3 vulnerabilities found for hmigxu_firmware by schneider-electric

FKIE_CVE-2019-6833

Vulnerability from fkie_nvd - Published: 2019-09-17 20:15 - Updated: 2025-09-30 15:15
Summary
A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel.
Impacted products
Vendor Product Version
schneider-electric hmigto_firmware -
schneider-electric hmigto1300 -
schneider-electric hmigto1310 -
schneider-electric hmigto2300 -
schneider-electric hmigto2310 -
schneider-electric hmigto2315 -
schneider-electric hmigto3510 -
schneider-electric hmigto4310 -
schneider-electric hmigto5310 -
schneider-electric hmigto5315 -
schneider-electric hmigto6310 -
schneider-electric hmigto6315 -
schneider-electric hmisto_firmware -
schneider-electric hmisto501 -
schneider-electric hmisto511 -
schneider-electric hmisto512 -
schneider-electric hmisto531 -
schneider-electric hmisto532 -
schneider-electric hmisto705 -
schneider-electric hmisto715 -
schneider-electric hmisto735 -
schneider-electric xbtgh_firmware -
schneider-electric xbtgh2460 -
schneider-electric hmigtu_firmware -
schneider-electric hmig2u -
schneider-electric hmig3u -
schneider-electric hmig3ufc -
schneider-electric hmig5u -
schneider-electric hmig5u2 -
schneider-electric hmig5ufc -
schneider-electric hmig5ul8a -
schneider-electric hmiscu_firmware -
schneider-electric hmiscu6a5 -
schneider-electric hmiscu6b5 -
schneider-electric hmiscu8a5 -
schneider-electric hmiscu8b5 -
schneider-electric hmistu_firmware -
schneider-electric hmistu655 -
schneider-electric hmistu655w -
schneider-electric hmistu855 -
schneider-electric hmistu855w -
schneider-electric xbtgt_firmware -
schneider-electric xbtgt2430 -
schneider-electric xbtgt2930 -
schneider-electric hmigxo_firmware -
schneider-electric hmigxo -
schneider-electric hmigxu_firmware -
schneider-electric hmigxu35 -
schneider-electric hmigxu55 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:hmigto_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6510726D-EADF-49AA-B1CC-44A481E216EE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmigto1300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E3E3852-4A76-44BA-9836-67C7DB2743B6",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmigto1310:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "09C1A913-6539-49E7-844A-ED2C28D41C77",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmigto2300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C8385FB-E116-4E3C-9BBD-06BC2A3A9354",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmigto2310:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4DF3F01C-2C36-4CC4-9D03-905ED11A4204",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmigto2315:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B894F4D1-27D7-443C-8DAF-5967FD4C8244",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmigto3510:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "24CEE9FE-04EC-4DFB-944E-C11D891A9D4F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmigto4310:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6FF55E8-0AE7-4375-969B-3D0E9E1B3956",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmigto5310:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C012A402-6270-4080-A499-8582D63E2110",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmigto5315:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E310E6C5-86EA-442D-A8B6-48A0DE51BD75",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmigto6310:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67A0ECE4-4090-4FF4-86F9-FB7BA6E55A78",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmigto6315:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1D8656F-3FF8-4966-93AA-9C60B9E3BCDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:hmisto_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21DDEE23-31A6-4EC7-82AB-8AEB666632BA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmisto501:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A89AD4A2-B1D2-4C4F-AD5C-F918FB0998B2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmisto511:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68419956-84CF-4671-B188-3FFD3AB64CB6",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmisto512:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "53726A99-8386-4E59-A216-8958C0276F9C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmisto531:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "207028CD-EE56-4514-ACEE-F6A725BE9151",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmisto532:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B16CCC7-62E1-4309-8D0C-28394C993EB4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmisto705:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "02CF4B93-1AE5-4E0C-8574-D3135739726D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmisto715:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F67F0E9C-14DF-4E9D-8F91-016C362B591B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmisto735:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25809843-3CE7-4385-A00D-B59041D57126",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:xbtgh_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4B506E7-30CB-44DD-A9CA-078EF0276807",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:xbtgh2460:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA694A26-4B62-4EA8-962D-16F4AD9902E2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmigtu_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "28C5D119-6FCD-493B-974F-FADFF7400749",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmig2u:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FC199C1-D633-4264-B7E6-87C716BBE519",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmig3u:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EFF2C9FF-6BE3-4016-91A1-3EDDF4BB1DFE",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmig3ufc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A41ADBA-32EE-406D-9BD0-5D52E6BD2455",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmig5u:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E72FE48D-3B73-48DA-BABE-F0871E118E7E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmig5u2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E881CC09-2083-4958-A08B-C6A1A6368368",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmig5ufc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF830232-50AC-4E52-B70C-05C65AAF4148",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmig5ul8a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C91CAFE-8A82-45DC-BE38-32754FFB1547",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:hmiscu_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E11C974-4857-4440-982E-B65AD272199E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmiscu6a5:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "101818F1-2F32-462C-95AC-5E86D6226352",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmiscu6b5:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD1D313B-B49C-4C3D-B5EE-40953E8836EC",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmiscu8a5:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BAAF924-EA44-4298-A481-328E09919E8D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmiscu8b5:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD7F9E54-F450-4CA1-8DEA-265645D851E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:hmistu_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5E181BEA-64DD-434B-9F05-F1B7622E3E35",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmistu655:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B91DC91-138F-4569-B24B-6EF17F22212B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmistu655w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D66FFBEB-1013-4971-A84A-371E817250DA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmistu855:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B8F304E9-87D2-4AAF-A9A8-5F55CA89818F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmistu855w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B7D21AF-BE69-48E2-A269-F60424C0A332",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:xbtgt_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B3692DF-9B21-4B63-B8D2-B4186A466282",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:xbtgt2430:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA541D29-0B14-4513-90C2-4D7FD23BEF47",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:xbtgt2930:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0009BA04-69B1-4996-880B-8040C1853AF1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:hmigxo_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "24D13D62-38F0-406C-8EC2-70FDDD2AA3A7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmigxo:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C619F99C-7F9A-4477-9A1A-D84A6E4D38EB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:hmigxu_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "963D9100-111B-43B2-B0A6-AC25A88905B6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmigxu35:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA28DD48-3CA6-49BF-89A3-7D655A986289",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:hmigxu55:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D005BC2-F5DB-405C-A961-7B49FF5CB620",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-754 \u2013 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad CWE-754 - Comprobaci\u00f3n inadecuada de condiciones inusuales o excepcionales en los paneles Magelis HMI (todas las versiones de - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU) congelaci\u00f3n temporal de la HMI cuando se recibe una alta tasa de tramas. Cuando se detiene el ataque, el panel de HMI procesa los comandos almacenados en el b\u00fafer."
    }
  ],
  "id": "CVE-2019-6833",
  "lastModified": "2025-09-30T15:15:39.103",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2019-09-17T20:15:12.467",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
    },
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-754"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-754"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2019-6833 (GCVE-0-2019-6833)

Vulnerability from cvelistv5 – Published: 2019-09-17 19:36 – Updated: 2025-09-30 14:36
VLAI?
Summary
A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel.
CWE
  • CWE-754 - – Improper Check for Unusual or Exceptional Conditions
Assigner
Impacted products
Vendor Product Version
Schneider Electric SE Magelis HMI Panels Affected: all versions of HMIGTO
Affected: all versions of HMISTO
Affected: all versions of XBTGH
Affected: all versions of HMIGTU
Affected: all versions of HMIGTUX
Affected: all versions of HMISCU
Affected: all versions of HMISTU
Affected: all versions of XBTGT
Affected: all versions of HMIGXO
Affected: all versions of HMIGXU
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.400Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2019-6833",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-30T14:36:06.892056Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-30T14:36:19.669Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Magelis HMI Panels",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "all versions of HMIGTO"
            },
            {
              "status": "affected",
              "version": "all versions of HMISTO"
            },
            {
              "status": "affected",
              "version": "all versions of XBTGH"
            },
            {
              "status": "affected",
              "version": "all versions of HMIGTU"
            },
            {
              "status": "affected",
              "version": "all versions of HMIGTUX"
            },
            {
              "status": "affected",
              "version": "all versions of HMISCU"
            },
            {
              "status": "affected",
              "version": "all versions of HMISTU"
            },
            {
              "status": "affected",
              "version": "all versions of XBTGT"
            },
            {
              "status": "affected",
              "version": "all versions of HMIGXO"
            },
            {
              "status": "affected",
              "version": "all versions of HMIGXU"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-754 \u2013 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754 \u2013 Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-02T12:13:24.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2019-6833",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Magelis HMI Panels",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "all versions of HMIGTO"
                          },
                          {
                            "version_value": "all versions of HMISTO"
                          },
                          {
                            "version_value": "all versions of XBTGH"
                          },
                          {
                            "version_value": "all versions of HMIGTU"
                          },
                          {
                            "version_value": "all versions of HMIGTUX"
                          },
                          {
                            "version_value": "all versions of HMISCU"
                          },
                          {
                            "version_value": "all versions of HMISTU"
                          },
                          {
                            "version_value": "all versions of XBTGT"
                          },
                          {
                            "version_value": "all versions of XBTGT"
                          },
                          {
                            "version_value": "all versions of HMIGXO"
                          },
                          {
                            "version_value": "all versions of HMIGXU"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-754 \u2013 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-754 \u2013 Improper Check for Unusual or Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01"
            },
            {
              "name": "https://security.cse.iitk.ac.in/responsible-disclosure",
              "refsource": "MISC",
              "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2019-6833",
    "datePublished": "2019-09-17T19:36:57.000Z",
    "dateReserved": "2019-01-25T00:00:00.000Z",
    "dateUpdated": "2025-09-30T14:36:19.669Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6833 (GCVE-0-2019-6833)

Vulnerability from nvd – Published: 2019-09-17 19:36 – Updated: 2025-09-30 14:36
VLAI?
Summary
A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel.
CWE
  • CWE-754 - – Improper Check for Unusual or Exceptional Conditions
Assigner
Impacted products
Vendor Product Version
Schneider Electric SE Magelis HMI Panels Affected: all versions of HMIGTO
Affected: all versions of HMISTO
Affected: all versions of XBTGH
Affected: all versions of HMIGTU
Affected: all versions of HMIGTUX
Affected: all versions of HMISCU
Affected: all versions of HMISTU
Affected: all versions of XBTGT
Affected: all versions of HMIGXO
Affected: all versions of HMIGXU
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.400Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2019-6833",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-30T14:36:06.892056Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-30T14:36:19.669Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Magelis HMI Panels",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "all versions of HMIGTO"
            },
            {
              "status": "affected",
              "version": "all versions of HMISTO"
            },
            {
              "status": "affected",
              "version": "all versions of XBTGH"
            },
            {
              "status": "affected",
              "version": "all versions of HMIGTU"
            },
            {
              "status": "affected",
              "version": "all versions of HMIGTUX"
            },
            {
              "status": "affected",
              "version": "all versions of HMISCU"
            },
            {
              "status": "affected",
              "version": "all versions of HMISTU"
            },
            {
              "status": "affected",
              "version": "all versions of XBTGT"
            },
            {
              "status": "affected",
              "version": "all versions of HMIGXO"
            },
            {
              "status": "affected",
              "version": "all versions of HMIGXU"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-754 \u2013 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754 \u2013 Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-02T12:13:24.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2019-6833",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Magelis HMI Panels",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "all versions of HMIGTO"
                          },
                          {
                            "version_value": "all versions of HMISTO"
                          },
                          {
                            "version_value": "all versions of XBTGH"
                          },
                          {
                            "version_value": "all versions of HMIGTU"
                          },
                          {
                            "version_value": "all versions of HMIGTUX"
                          },
                          {
                            "version_value": "all versions of HMISCU"
                          },
                          {
                            "version_value": "all versions of HMISTU"
                          },
                          {
                            "version_value": "all versions of XBTGT"
                          },
                          {
                            "version_value": "all versions of XBTGT"
                          },
                          {
                            "version_value": "all versions of HMIGXO"
                          },
                          {
                            "version_value": "all versions of HMIGXU"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-754 \u2013 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-754 \u2013 Improper Check for Unusual or Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-225-01"
            },
            {
              "name": "https://security.cse.iitk.ac.in/responsible-disclosure",
              "refsource": "MISC",
              "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2019-6833",
    "datePublished": "2019-09-17T19:36:57.000Z",
    "dateReserved": "2019-01-25T00:00:00.000Z",
    "dateUpdated": "2025-09-30T14:36:19.669Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}