Search criteria

3 vulnerabilities found for ininet_webserver by spidercontrol

FKIE_CVE-2017-13995

Vulnerability from fkie_nvd - Published: 2017-10-05 01:29 - Updated: 2025-04-20 01:37
Severity ?
Summary
An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables.
Impacted products
Vendor Product Version
spidercontrol ininet_webserver *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:spidercontrol:ininet_webserver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "24FF91D4-FA32-41D0-8B22-21BE1DA8B74B",
              "versionEndIncluding": "2.02.0000",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema de autenticaci\u00f3n incorrecta en iniNet Solutions iniNet Webserver en todas las versiones anteriores a la V2.02.0111. El servidor web no autentica correctamente a los usuarios, lo que podr\u00eda permitir que un atacante malicioso acceda a informaci\u00f3n sensible como las p\u00e1ginas HMI o que modifiquen variables PLC."
    }
  ],
  "id": "CVE-2017-13995",
  "lastModified": "2025-04-20T01:37:25.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": true,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 10.0,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.0,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2017-10-05T01:29:05.227",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/100951"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/100951"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2017-13995 (GCVE-0-2017-13995)

Vulnerability from cvelistv5 – Published: 2017-10-04 07:00 – Updated: 2024-08-05 19:13
VLAI?
Summary
An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a iniNet Solutions GmbH SCADA Webserver Affected: iniNet Solutions GmbH SCADA Webserver
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:13:41.584Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "100951",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/100951"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "iniNet Solutions GmbH SCADA Webserver",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "iniNet Solutions GmbH SCADA Webserver"
            }
          ]
        }
      ],
      "datePublic": "2017-10-03T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-10-04T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "100951",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/100951"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-13995",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "iniNet Solutions GmbH SCADA Webserver",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "iniNet Solutions GmbH SCADA Webserver"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "100951",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/100951"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-13995",
    "datePublished": "2017-10-04T07:00:00",
    "dateReserved": "2017-08-30T00:00:00",
    "dateUpdated": "2024-08-05T19:13:41.584Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-13995 (GCVE-0-2017-13995)

Vulnerability from nvd – Published: 2017-10-04 07:00 – Updated: 2024-08-05 19:13
VLAI?
Summary
An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a iniNet Solutions GmbH SCADA Webserver Affected: iniNet Solutions GmbH SCADA Webserver
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:13:41.584Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "100951",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/100951"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "iniNet Solutions GmbH SCADA Webserver",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "iniNet Solutions GmbH SCADA Webserver"
            }
          ]
        }
      ],
      "datePublic": "2017-10-03T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-10-04T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "100951",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/100951"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-13995",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "iniNet Solutions GmbH SCADA Webserver",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "iniNet Solutions GmbH SCADA Webserver"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "100951",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/100951"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-13995",
    "datePublished": "2017-10-04T07:00:00",
    "dateReserved": "2017-08-30T00:00:00",
    "dateUpdated": "2024-08-05T19:13:41.584Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}