cve-2020-14521
Vulnerability from cvelistv5
Published
2022-02-11 17:40
Modified
2024-09-16 23:45
Severity ?
EPSS score ?
Summary
Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition.
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04 | government-resource | |
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf | vendor-advisory |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.835Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "government-resource", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04" }, { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "C Controller Interface Module Utility", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 2.00", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE Control Network Data Collector", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "Version 1.00A" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE Field Network Data Collector", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "Version 1.00A" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Data Collector", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "Version 1.00A" } ] }, { "defaultStatus": "unaffected", "product": "CPU Module Logging Configuration Tool", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.100E", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "CW Configurator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.010L", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Data Transfer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 3.42U", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "EZSocket", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 5.1", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "FR Configurator SW3", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] }, { "defaultStatus": "unaffected", "product": "FR Configurator2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.26C", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "GT Designer2 Classic", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] }, { "defaultStatus": "unaffected", "product": "GT Designer3 Version1 (GOT1000)", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.241B", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "GT Designer3 Version1 (GOT2000)", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.241B", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "GT SoftGOT1000 Version3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 3.200J", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "GT SoftGOT2000 Version1", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.241B", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "GX Developer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 8.504A", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "GX LogViewer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.100E", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "GX Works2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.601B", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "GX Works3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.063R", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "M_CommDTM-IO-Link", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.03D", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MELFA-Works", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 4.4", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MELSEC WinCPU Setting Utility", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT Complete Clean Up Tool", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.06G", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT EM Software Development Kit", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.015R", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT iQ AppPortal", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.17T", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT Navigator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 2.74C", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MI Configurator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.004E", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Motion Control Setting", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.005F", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Motorizer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.005F", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MR Configurator2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.125F", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MT Works2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.167Z", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MTConnect Data Collector", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.1.4.0", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MX Component", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 4.20W", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MX MESInterface", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.21X", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MX MESInterface-R", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.12N", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MX Sheet", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 2.15R", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Network Interface Board CC IE Control Utility", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.29F", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Network Interface Board CC IE Field Utility", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Versions 1.16S", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Network Interface Board CC-Link Ver.2 Utility", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.23Z", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Network Interface Board MNETH Utility", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 34L", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Position Board utility 2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 3.20", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "PX Developer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.53F", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "RT ToolBox2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 3.73B", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "RT ToolBox3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.82L", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Setting/Monitoring tools for the C Controller module", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "SW3PVC-CCPU Version 3.13P", "status": "affected", "version": "unspecified", "versionType": "custom" }, { "lessThanOrEqual": "SW4PVC-CCPU Version 4.12N", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "SLMP Data Collector", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.04E", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Mashav Sapir of Claroty reported this vulnerability to CISA" } ], "datePublic": "2020-07-30T06:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition.\n\n\u003cp\u003e\u003c/p\u003e" } ], "value": "Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-428", "description": "CWE-428 Unquoted Search Path or Element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-07T21:29:25.280Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04" }, { "tags": [ "vendor-advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf" } ], "source": { "advisory": "ICSA-20-212-04", "discovery": "UNKNOWN" }, "title": "Mitsubishi Electric Factory Automation Engineering Products Unquoted Search Path or Element", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2020-07-30T16:50:00.000Z", "ID": "CVE-2020-14521", "STATE": "PUBLIC", "TITLE": "Mitsubishi Electric Factory Automation Engineering Products Unquoted Search Path or Element" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "C Controller Interface Module Utility", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "C Controller Module Setting and Monitoring Tool", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "CC-Link IE Control Network Data Collector", "version": { "version_data": [ { "version_affected": "=", "version_value": "Version 1.00A" } ] } }, { "product_name": "CC-Link IE Field Network Data Collector", "version": { "version_data": [ { "version_affected": "=", "version_value": "Version 1.00A" } ] } }, { "product_name": "CC-Link IE TSN Data Collector", "version": { "version_data": [ { "version_affected": "=", "version_value": "Version 1.00A" } ] } }, { "product_name": "CPU Module Logging Configuration Tool", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.100E" } ] } }, { "product_name": "CW Configurator", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.010L" } ] } }, { "product_name": "Data Transfer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 3.42U and prior" } ] } }, { "product_name": "EZSocket", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 5.1" } ] } }, { "product_name": "FR Configurator SW3", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "FR Configurator2", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "GT Designer2 Classic", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "GT Designer3 Version1 (GOT1000)", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.241B" } ] } }, { "product_name": "GT Designer3 Version1 (GOT2000)", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.241B" } ] } }, { "product_name": "GT SoftGOT1000 Version3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 3.200J" } ] } }, { "product_name": "GT SoftGOT2000 Version1", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.241B" } ] } }, { "product_name": "GX Developer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 8.504A" } ] } }, { "product_name": "GX LogViewer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.100E" } ] } }, { "product_name": "GX Works2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.601B" } ] } }, { "product_name": "GX Works3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.063R" } ] } }, { "product_name": "M_CommDTM-IO-Link", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "MELFA-Works", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 4.4" } ] } }, { "product_name": "MELSEC WinCPU Setting Utility", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "MELSOFT Complete Clean Up Tool", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.06G" } ] } }, { "product_name": "MELSOFT EM Software Development Kit", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "MELSOFT iQ AppPortal", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.17T" } ] } }, { "product_name": "MELSOFT Navigator", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 2.74C" } ] } }, { "product_name": "MI Configurator", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "Motion Control Setting", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.005F" } ] } }, { "product_name": "Motorizer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.005F" } ] } }, { "product_name": "MR Configurator2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.125F" } ] } }, { "product_name": "MT Works2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.167Z" } ] } }, { "product_name": "MTConnect Data Collector", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.1.4.0" } ] } }, { "product_name": "MX Component", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 4.20W" } ] } }, { "product_name": "MX MESInterface", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.21X" } ] } }, { "product_name": "MX MESInterface-R", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.12N" } ] } }, { "product_name": "MX Sheet", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 2.15R" } ] } }, { "product_name": "Network Interface Board CC IE Control Utility", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "Network Interface Board CC IE Field Utility", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "Network Interface Board CC-Link Ver.2 Utility", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "Network Interface Board MNETH Utility", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "Position Board utility 2", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "PX Developer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "version 1.53F" } ] } }, { "product_name": "RT ToolBox2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 3.73B" } ] } }, { "product_name": "RT ToolBox3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.82L" } ] } }, { "product_name": "Setting/monitoring tools for the C Controller module", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "SLMP Data Collector", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.04E" } ] } } ] }, "vendor_name": "Mitsubishi Electric" } ] } }, "credit": [ { "lang": "eng", "value": "Mashav Sapir of Claroty reported this vulnerability to CISA" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-428 Unquoted Search Path or Element" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04" }, { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf" } ] }, "solution": [ { "lang": "en" } ], "source": { "advisory": "ICSA-20-212-04", "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-14521", "datePublished": "2022-02-11T17:40:28.403703Z", "dateReserved": "2020-06-19T00:00:00", "dateUpdated": "2024-09-16T23:45:38.115Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-5603
Vulnerability from cvelistv5
Published
2020-06-30 10:20
Modified
2024-08-04 08:30
Severity ?
EPSS score ?
Summary
Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to cause a denial of service (DoS) condition attacks via unspecified vectors.
References
▼ | URL | Tags |
---|---|---|
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf | x_refsource_MISC | |
https://jvn.jp/en/vu/JVNVU90307594/index.html | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Mitsubishi Electric Corporation | Mitsubishi Electoric FA Engineering Software |
Version: CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:30:24.586Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Mitsubishi Electoric FA Engineering Software", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier" } ] } ], "descriptions": [ { "lang": "en", "value": "Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to cause a denial of service (DoS) condition attacks via unspecified vectors." } ], "problemTypes": [ { "descriptions": [ { "description": "Uncontrolled Resource Consumption", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-30T10:20:45", "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "shortName": "jpcert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vultures@jpcert.or.jp", "ID": "CVE-2020-5603", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Mitsubishi Electoric FA Engineering Software", "version": { "version_data": [ { "version_value": "CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier" } ] } } ] }, "vendor_name": "Mitsubishi Electric Corporation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to cause a denial of service (DoS) condition attacks via unspecified vectors." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf" }, { "name": "https://jvn.jp/en/vu/JVNVU90307594/index.html", "refsource": "MISC", "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html" } ] } } } }, "cveMetadata": { "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "assignerShortName": "jpcert", "cveId": "CVE-2020-5603", "datePublished": "2020-06-30T10:20:45", "dateReserved": "2020-01-06T00:00:00", "dateUpdated": "2024-08-04T08:30:24.586Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-6942
Vulnerability from cvelistv5
Published
2024-01-30 09:06
Modified
2024-11-01 08:35
Severity ?
EPSS score ?
Summary
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally.
References
▼ | URL | Tags |
---|---|---|
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf | vendor-advisory | |
https://jvn.jp/vu/JVNVU95103362 | government-resource | |
https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02 | government-resource |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Mitsubishi Electric Corporation | EZSocket |
Version: 3.0 and later |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T08:42:08.534Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU95103362" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EZSocket", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "3.0 and later" } ] }, { "defaultStatus": "unaffected", "product": "GT Designer3 Version1(GOT1000)", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "GT Designer3 Version1(GOT2000)", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "GX Works2", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "1.11M and later" } ] }, { "defaultStatus": "unaffected", "product": "GX Works3", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "1.106L and prior" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT Navigator", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "1.04E and later" } ] }, { "defaultStatus": "unaffected", "product": "MT Works2", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MX Component", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "4.00A and later" } ] }, { "defaultStatus": "unaffected", "product": "MX OPC Server DA/UA", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally." } ], "value": "Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally." } ], "impacts": [ { "capecId": "CAPEC-115", "descriptions": [ { "lang": "en", "value": "CAPEC-115 Authentication Bypass" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-01T08:35:48.579Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf" }, { "tags": [ "government-resource" ], "url": "https://jvn.jp/vu/JVNVU95103362" }, { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2023-6942", "datePublished": "2024-01-30T09:06:27.941Z", "dateReserved": "2023-12-19T08:00:02.751Z", "dateUpdated": "2024-11-01T08:35:48.579Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-6943
Vulnerability from cvelistv5
Published
2024-01-30 09:09
Modified
2024-11-01 08:36
Severity ?
EPSS score ?
Summary
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.
References
▼ | URL | Tags |
---|---|---|
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf | vendor-advisory | |
https://jvn.jp/vu/JVNVU95103362 | government-resource | |
https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02 | government-resource |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Mitsubishi Electric Corporation | EZSocket |
Version: 3.0 and later |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T08:42:08.552Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU95103362" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EZSocket", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "3.0 and later" } ] }, { "defaultStatus": "unaffected", "product": "GT Designer3 Version1(GOT1000)", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "GT Designer3 Version1(GOT2000)", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "GX Works2", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "1.11M and later" } ] }, { "defaultStatus": "unaffected", "product": "GX Works3", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "1.106L and prior" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT Navigator", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "1.04E and later" } ] }, { "defaultStatus": "unaffected", "product": "MT Works2", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] }, { "defaultStatus": "unaffected", "product": "MX Component", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "4.00A and later" } ] }, { "defaultStatus": "unaffected", "product": "MX OPC Server DA/UA", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products." } ], "value": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products." } ], "impacts": [ { "descriptions": [ { "lang": "en", "value": "Remote Code Execution" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-470", "description": "CWE-470 Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-01T08:36:32.008Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf" }, { "tags": [ "government-resource" ], "url": "https://jvn.jp/vu/JVNVU95103362" }, { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2023-6943", "datePublished": "2024-01-30T09:09:29.248Z", "dateReserved": "2023-12-19T08:00:07.140Z", "dateUpdated": "2024-11-01T08:36:32.008Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-5602
Vulnerability from cvelistv5
Published
2020-06-30 10:20
Modified
2024-08-04 08:30
Severity ?
EPSS score ?
Summary
Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to conduct XML External Entity (XXE) attacks via unspecified vectors.
References
▼ | URL | Tags |
---|---|---|
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf | x_refsource_MISC | |
https://jvn.jp/en/vu/JVNVU90307594/index.html | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Mitsubishi Electric Corporation | Mitsubishi Electoric FA Engineering Software |
Version: CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:30:24.529Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Mitsubishi Electoric FA Engineering Software", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier" } ] } ], "descriptions": [ { "lang": "en", "value": "Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to conduct XML External Entity (XXE) attacks via unspecified vectors." } ], "problemTypes": [ { "descriptions": [ { "description": "XML external entities (XXE)", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-30T10:20:45", "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "shortName": "jpcert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vultures@jpcert.or.jp", "ID": "CVE-2020-5602", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Mitsubishi Electoric FA Engineering Software", "version": { "version_data": [ { "version_value": "CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier" } ] } } ] }, "vendor_name": "Mitsubishi Electric Corporation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to conduct XML External Entity (XXE) attacks via unspecified vectors." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "XML external entities (XXE)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf" }, { "name": "https://jvn.jp/en/vu/JVNVU90307594/index.html", "refsource": "MISC", "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html" } ] } } } }, "cveMetadata": { "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "assignerShortName": "jpcert", "cveId": "CVE-2020-5602", "datePublished": "2020-06-30T10:20:45", "dateReserved": "2020-01-06T00:00:00", "dateUpdated": "2024-08-04T08:30:24.529Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14523
Vulnerability from cvelistv5
Published
2022-02-11 17:40
Modified
2024-09-16 23:36
Severity ?
EPSS score ?
Summary
Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03 | x_refsource_MISC | |
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf | x_refsource_MISC | |
https://jvn.jp/vu/JVNVU90224831/ | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Mitsubishi Electric | CW Configurator |
Version: unspecified < |
||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.640Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU90224831/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CW Configurator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.010L", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "FR Configurator2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.22Y", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "GX Works2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.595V", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "GX Works3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.063R", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MELSOFT iQ AppPortal", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.17T", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MELSOFT Navigator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version2.70Y", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MI Configurator", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] }, { "product": "MR Configurator2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.110Q", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MT Works2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Versions 1.156N", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MX Component", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 4.20W", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "RT ToolBox3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Versions 1.70Y", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MELSEC iQ-R Series Motion Module", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Versions 10", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Mashav Sapir of Claroty reported this vulnerability to CISA" } ], "datePublic": "2020-07-30T00:00:00", "descriptions": [ { "lang": "en", "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-18T23:17:23", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://jvn.jp/vu/JVNVU90224831/" } ], "source": { "advisory": "ICSA-20-212-03", "discovery": "UNKNOWN" }, "title": "Mitsubishi Electric Factory Automation Products Path Traversal", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2020-07-30T16:50:00.000Z", "ID": "CVE-2020-14523", "STATE": "PUBLIC", "TITLE": "Mitsubishi Electric Factory Automation Products Path Traversal" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CW Configurator", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.010L" } ] } }, { "product_name": "FR Configurator2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.22Y" } ] } }, { "product_name": "GX Works2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.595V" } ] } }, { "product_name": "GX Works3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.063R" } ] } }, { "product_name": "MELSOFT iQ AppPortal", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.17T" } ] } }, { "product_name": "MELSOFT Navigator", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version2.70Y" } ] } }, { "product_name": "MI Configurator", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "MR Configurator2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.110Q" } ] } }, { "product_name": "MT Works2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Versions 1.156N" } ] } }, { "product_name": "MX Component", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 4.20W" } ] } }, { "product_name": "RT ToolBox3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Versions 1.70Y" } ] } }, { "product_name": "MELSEC iQ-R Series Motion Module", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Versions 10" } ] } } ] }, "vendor_name": "Mitsubishi Electric" } ] } }, "credit": [ { "lang": "eng", "value": "Mashav Sapir of Claroty reported this vulnerability to CISA" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03" }, { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf" }, { "name": "https://jvn.jp/vu/JVNVU90224831/", "refsource": "MISC", "url": "https://jvn.jp/vu/JVNVU90224831/" } ] }, "solution": [ { "lang": "en" } ], "source": { "advisory": "ICSA-20-212-03", "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-14523", "datePublished": "2022-02-11T17:40:29.187685Z", "dateReserved": "2020-06-19T00:00:00", "dateUpdated": "2024-09-16T23:36:20.299Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14496
Vulnerability from cvelistv5
Published
2022-05-19 17:24
Modified
2024-08-04 12:46
Severity ?
EPSS score ?
Summary
Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed.
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Mitsubishi Electric | CPU Module Logging Configuration Tool |
Version: All < |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.676Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CPU Module Logging Configuration Tool", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.100E", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "CW Configurator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.010L", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "Data Transfer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "3.40S", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "EZSocket", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "4.5", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "FR Configurator2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.22Y", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "GT Designer3 Version1 (GOT2000)", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.235V", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "GT SoftGOT1000 Version3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "3.200J", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "GT SoftGOT1000 Version3", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "GT SoftGOT2000 Version1", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.235V", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "GX LogViewer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.100E", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "GX Works2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.592S", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "GX Works3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.063R", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "M_CommDTM-HART", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All 1.00A" } ] }, { "product": "M_CommDTM-IO-Link", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "MELFA-Works", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "4.3", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "MELSEC WinCPU Setting Utility", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "MELSOFT EM Software Development Kit (EM Configurator)", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.010L", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "MELSOFT FieldDeviceConfigurator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.03D", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "MELSOFT Navigator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "2.62Q", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "MH11 SettingTool Version2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "2.002C", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "MI Configurator", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "Motorizer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.005F", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "MR Configurator2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.105K", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "MT Works2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.156N", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "MX Component", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "4.19V", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "Network Interface Board CC IE Control utility", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "Network Interface Board CC IE Field Utility", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "Network Interface Board CC-Link Ver.2 Utility", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "Network Interface Board MNETH utility", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "PX Developer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.52E", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "RT ToolBox2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "3.72A", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "RT ToolBox3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.70Y", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "Setting/monitoring tools for the C Controller module", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] } ], "descriptions": [ { "lang": "en", "value": "Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-275", "description": "CWE-275 Permission Issues", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-19T17:24:43", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02" } ], "source": { "advisory": "ICSA-20-212-02", "discovery": "UNKNOWN" }, "title": "Mitsubishi Electric Multiple Factory Automation Engineering Software Products (Update A) - Permission Issues", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2020-14496", "STATE": "PUBLIC", "TITLE": "Mitsubishi Electric Multiple Factory Automation Engineering Software Products (Update A) - Permission Issues" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CPU Module Logging Configuration Tool", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.100E" } ] } }, { "product_name": "CW Configurator", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.010L" } ] } }, { "product_name": "Data Transfer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "3.40S" } ] } }, { "product_name": "EZSocket", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "4.5" } ] } }, { "product_name": "FR Configurator2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.22Y" } ] } }, { "product_name": "GT Designer3 Version1 (GOT2000)", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.235V" } ] } }, { "product_name": "GT SoftGOT1000 Version3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "3.200J" } ] } }, { "product_name": "GT SoftGOT1000 Version3", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } }, { "product_name": "GT SoftGOT2000 Version1", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.235V" } ] } }, { "product_name": "GX LogViewer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.100E" } ] } }, { "product_name": "GX Works2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.592S" } ] } }, { "product_name": "GX Works3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.063R" } ] } }, { "product_name": "M_CommDTM-HART", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "1.00A" } ] } }, { "product_name": "M_CommDTM-IO-Link", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } }, { "product_name": "MELFA-Works", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "4.3" } ] } }, { "product_name": "MELSEC WinCPU Setting Utility", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } }, { "product_name": "MELSOFT EM Software Development Kit (EM Configurator)", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.010L" } ] } }, { "product_name": "MELSOFT FieldDeviceConfigurator", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.03D" } ] } }, { "product_name": "MELSOFT Navigator", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "2.62Q" } ] } }, { "product_name": "MH11 SettingTool Version2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "2.002C" } ] } }, { "product_name": "MI Configurator", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } }, { "product_name": "Motorizer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.005F" } ] } }, { "product_name": "MR Configurator2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.105K" } ] } }, { "product_name": "MT Works2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.156N" } ] } }, { "product_name": "MX Component", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "4.19V" } ] } }, { "product_name": "Network Interface Board CC IE Control utility", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } }, { "product_name": "Network Interface Board CC IE Field Utility", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } }, { "product_name": "Network Interface Board CC-Link Ver.2 Utility", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } }, { "product_name": "Network Interface Board MNETH utility", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } }, { "product_name": "PX Developer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.52E" } ] } }, { "product_name": "RT ToolBox2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "3.72A" } ] } }, { "product_name": "RT ToolBox3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.70Y" } ] } }, { "product_name": "Setting/monitoring tools for the C Controller module", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } } ] }, "vendor_name": "Mitsubishi Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-275 Permission Issues" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02" } ] }, "source": { "advisory": "ICSA-20-212-02", "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-14496", "datePublished": "2022-05-19T17:24:43", "dateReserved": "2020-06-19T00:00:00", "dateUpdated": "2024-08-04T12:46:34.676Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-20587
Vulnerability from cvelistv5
Published
2021-02-19 19:55
Modified
2024-08-03 17:45
Severity ?
EPSS score ?
Summary
Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
References
▼ | URL | Tags |
---|---|---|
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf | vendor-advisory | |
https://jvn.jp/vu/JVNVU92330101/index.html | government-resource | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02 | government-resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Mitsubishi Electric Corporation | FA Engineering Software |
Version: CPU Module Logging Configuration Tool versions 1.112R and prior Version: CW Configurator versions 1.011M and prior Version: Data Transfer versions 3.44W and prior Version: EZSocket versions 5.4 and prior Version: FR Configurator all versions Version: FR Configurator SW3 all versions Version: FR Configurator2 versions 1.24A and prior Version: GT Designer3 Version1(GOT1000) versions 1.250L and prior Version: GT Designer3 Version1(GOT2000) versions 1.250L and prior Version: GT SoftGOT1000 Version3 versions 3.245F and prior Version: GT SoftGOT2000 Version1 versions 1.250L and prior Version: GX Configurator-DP versions 7.14Q and prior Version: GX Configurator-QP all versions Version: GX Developer versions 8.506C and prior Version: GX Explorer all versions Version: GX IEC Developer all versions Version: GX LogViewer versions 1.115U and prior Version: GX RemoteService-I all versions Version: GX Works2 versions 1.597X and prior Version: GX Works3 versions 1.070Y and prior Version: iQ Monozukuri ANDON (Data Transfer) all versions Version: iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions Version: M_CommDTM-HART all versions Version: M_CommDTM-IO-Link versions 1.03D and prior Version: MELFA-Works versions 4.4 and prior Version: MELSEC WinCPU Setting Utility all versions Version: MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior Version: MELSOFT Navigator versions 2.74C and prior Version: MH11 SettingTool Version2 versions 2.004E and prior Version: MI Configurator versions 1.004E and prior Version: MT Works2 versions 1.167Z and prior Version: MX Component versions 5.001B and prior Version: Network Interface Board CC IE Control utility versions 1.29F and prior Version: Network Interface Board CC IE Field Utility versions 1.16S and prior Version: Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior Version: Network Interface Board MNETH utility versions 34L and prior Version: PX Developer versions 1.53F and prior Version: RT ToolBox2 versions 3.73B and prior Version: RT ToolBox3 versions 1.82L and prior Version: Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior Version: SLMP Data Collector versions 1.04E and prior |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:45:44.677Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU92330101/index.html" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "FA Engineering Software", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "CPU Module Logging Configuration Tool versions 1.112R and prior" }, { "status": "affected", "version": "CW Configurator versions 1.011M and prior" }, { "status": "affected", "version": "Data Transfer versions 3.44W and prior" }, { "status": "affected", "version": "EZSocket versions 5.4 and prior" }, { "status": "affected", "version": "FR Configurator all versions" }, { "status": "affected", "version": "FR Configurator SW3 all versions" }, { "status": "affected", "version": "FR Configurator2 versions 1.24A and prior" }, { "status": "affected", "version": "GT Designer3 Version1(GOT1000) versions 1.250L and prior" }, { "status": "affected", "version": "GT Designer3 Version1(GOT2000) versions 1.250L and prior" }, { "status": "affected", "version": "GT SoftGOT1000 Version3 versions 3.245F and prior" }, { "status": "affected", "version": "GT SoftGOT2000 Version1 versions 1.250L and prior" }, { "status": "affected", "version": "GX Configurator-DP versions 7.14Q and prior" }, { "status": "affected", "version": "GX Configurator-QP all versions" }, { "status": "affected", "version": "GX Developer versions 8.506C and prior" }, { "status": "affected", "version": "GX Explorer all versions" }, { "status": "affected", "version": "GX IEC Developer all versions" }, { "status": "affected", "version": "GX LogViewer versions 1.115U and prior" }, { "status": "affected", "version": "GX RemoteService-I all versions" }, { "status": "affected", "version": "GX Works2 versions 1.597X and prior" }, { "status": "affected", "version": "GX Works3 versions 1.070Y and prior" }, { "status": "affected", "version": "iQ Monozukuri ANDON (Data Transfer) all versions" }, { "status": "affected", "version": "iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions" }, { "status": "affected", "version": "M_CommDTM-HART all versions" }, { "status": "affected", "version": "M_CommDTM-IO-Link versions 1.03D and prior" }, { "status": "affected", "version": "MELFA-Works versions 4.4 and prior" }, { "status": "affected", "version": "MELSEC WinCPU Setting Utility all versions" }, { "status": "affected", "version": "MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior" }, { "status": "affected", "version": "MELSOFT Navigator versions 2.74C and prior" }, { "status": "affected", "version": "MH11 SettingTool Version2 versions 2.004E and prior" }, { "status": "affected", "version": "MI Configurator versions 1.004E and prior" }, { "status": "affected", "version": "MT Works2 versions 1.167Z and prior" }, { "status": "affected", "version": "MX Component versions 5.001B and prior" }, { "status": "affected", "version": "Network Interface Board CC IE Control utility versions 1.29F and prior" }, { "status": "affected", "version": "Network Interface Board CC IE Field Utility versions 1.16S and prior" }, { "status": "affected", "version": "Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior" }, { "status": "affected", "version": "Network Interface Board MNETH utility versions 34L and prior" }, { "status": "affected", "version": "PX Developer versions 1.53F and prior" }, { "status": "affected", "version": "RT ToolBox2 versions 3.73B and prior" }, { "status": "affected", "version": "RT ToolBox3 versions 1.82L and prior" }, { "status": "affected", "version": "Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior" }, { "status": "affected", "version": "SLMP Data Collector versions 1.04E and prior" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets." } ], "value": "Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets." } ], "problemTypes": [ { "descriptions": [ { "description": "Heap-based buffer overflow", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2022-11-18T04:19:16.037Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf" }, { "tags": [ "government-resource" ], "url": "https://jvn.jp/vu/JVNVU92330101/index.html" }, { "tags": [ "government-resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2021-20587", "datePublished": "2021-02-19T19:55:37", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-08-03T17:45:44.677Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-20588
Vulnerability from cvelistv5
Published
2021-02-19 19:58
Modified
2024-08-03 17:45
Severity ?
EPSS score ?
Summary
Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
References
▼ | URL | Tags |
---|---|---|
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf | vendor-advisory | |
https://jvn.jp/vu/JVNVU92330101/index.html | government-resource | |
https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02 | government-resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Mitsubishi Electric Corporation | FA Engineering Software |
Version: CPU Module Logging Configuration Tool versions 1.112R and prior Version: CW Configurator versions 1.011M and prior Version: Data Transfer versions 3.44W and prior Version: EZSocket versions 5.4 and prior Version: FR Configurator all versions Version: FR Configurator SW3 all versions Version: FR Configurator2 versions 1.24A and prior Version: GT Designer3 Version1(GOT1000) versions 1.250L and prior Version: GT Designer3 Version1(GOT2000) versions 1.250L and prior Version: GT SoftGOT1000 Version3 versions 3.245F and prior Version: GT SoftGOT2000 Version1 versions 1.250L and prior Version: GX Configurator-DP versions 7.14Q and prior Version: GX Configurator-QP all versions Version: GX Developer versions 8.506C and prior Version: GX Explorer all versions Version: GX IEC Developer all versions Version: GX LogViewer versions 1.115U and prior Version: GX RemoteService-I all versions Version: GX Works2 versions 1.597X and prior Version: GX Works3 versions 1.070Y and prior Version: iQ Monozukuri ANDON (Data Transfer) all versions Version: iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions Version: M_CommDTM-HART all versions Version: M_CommDTM-IO-Link versions 1.03D and prior Version: MELFA-Works versions 4.4 and prior Version: MELSEC WinCPU Setting Utility all versions Version: MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior Version: MELSOFT Navigator versions 2.74C and prior Version: MH11 SettingTool Version2 versions 2.004E and prior Version: MI Configurator versions 1.004E and prior Version: MT Works2 versions 1.167Z and prior Version: MX Component versions 5.001B and prior Version: Network Interface Board CC IE Control utility versions 1.29F and prior Version: Network Interface Board CC IE Field Utility versions 1.16S and prior Version: Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior Version: Network Interface Board MNETH utility versions 34L and prior Version: PX Developer versions 1.53F and prior Version: RT ToolBox2 versions 3.73B and prior Version: RT ToolBox3 versions 1.82L and prior Version: Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior Version: SLMP Data Collector versions 1.04E and prior |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:45:44.696Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU92330101/index.html" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "FA Engineering Software", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "CPU Module Logging Configuration Tool versions 1.112R and prior" }, { "status": "affected", "version": "CW Configurator versions 1.011M and prior" }, { "status": "affected", "version": "Data Transfer versions 3.44W and prior" }, { "status": "affected", "version": "EZSocket versions 5.4 and prior" }, { "status": "affected", "version": "FR Configurator all versions" }, { "status": "affected", "version": "FR Configurator SW3 all versions" }, { "status": "affected", "version": "FR Configurator2 versions 1.24A and prior" }, { "status": "affected", "version": "GT Designer3 Version1(GOT1000) versions 1.250L and prior" }, { "status": "affected", "version": "GT Designer3 Version1(GOT2000) versions 1.250L and prior" }, { "status": "affected", "version": "GT SoftGOT1000 Version3 versions 3.245F and prior" }, { "status": "affected", "version": "GT SoftGOT2000 Version1 versions 1.250L and prior" }, { "status": "affected", "version": "GX Configurator-DP versions 7.14Q and prior" }, { "status": "affected", "version": "GX Configurator-QP all versions" }, { "status": "affected", "version": "GX Developer versions 8.506C and prior" }, { "status": "affected", "version": "GX Explorer all versions" }, { "status": "affected", "version": "GX IEC Developer all versions" }, { "status": "affected", "version": "GX LogViewer versions 1.115U and prior" }, { "status": "affected", "version": "GX RemoteService-I all versions" }, { "status": "affected", "version": "GX Works2 versions 1.597X and prior" }, { "status": "affected", "version": "GX Works3 versions 1.070Y and prior" }, { "status": "affected", "version": "iQ Monozukuri ANDON (Data Transfer) all versions" }, { "status": "affected", "version": "iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions" }, { "status": "affected", "version": "M_CommDTM-HART all versions" }, { "status": "affected", "version": "M_CommDTM-IO-Link versions 1.03D and prior" }, { "status": "affected", "version": "MELFA-Works versions 4.4 and prior" }, { "status": "affected", "version": "MELSEC WinCPU Setting Utility all versions" }, { "status": "affected", "version": "MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior" }, { "status": "affected", "version": "MELSOFT Navigator versions 2.74C and prior" }, { "status": "affected", "version": "MH11 SettingTool Version2 versions 2.004E and prior" }, { "status": "affected", "version": "MI Configurator versions 1.004E and prior" }, { "status": "affected", "version": "MT Works2 versions 1.167Z and prior" }, { "status": "affected", "version": "MX Component versions 5.001B and prior" }, { "status": "affected", "version": "Network Interface Board CC IE Control utility versions 1.29F and prior" }, { "status": "affected", "version": "Network Interface Board CC IE Field Utility versions 1.16S and prior" }, { "status": "affected", "version": "Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior" }, { "status": "affected", "version": "Network Interface Board MNETH utility versions 34L and prior" }, { "status": "affected", "version": "PX Developer versions 1.53F and prior" }, { "status": "affected", "version": "RT ToolBox2 versions 3.73B and prior" }, { "status": "affected", "version": "RT ToolBox3 versions 1.82L and prior" }, { "status": "affected", "version": "Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior" }, { "status": "affected", "version": "SLMP Data Collector versions 1.04E and prior" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets." } ], "value": "Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets." } ], "problemTypes": [ { "descriptions": [ { "description": "Improper handling of length parameter inconsistency", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-17T23:30:16.586Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf" }, { "tags": [ "government-resource" ], "url": "https://jvn.jp/vu/JVNVU92330101/index.html" }, { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2021-20588", "datePublished": "2021-02-19T19:58:29.101118Z", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-08-03T17:45:44.696Z", "serial": 1, "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2022-02-11 18:15
Modified
2024-11-21 05:03
Severity ?
8.3 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://jvn.jp/vu/JVNVU90224831/ | Third Party Advisory | |
ics-cert@hq.dhs.gov | https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03 | Patch, Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://jvn.jp/vu/JVNVU90224831/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03 | Patch, Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
mitsubishielectric | cw_configurator | * | |
mitsubishielectric | fr_configurator2 | * | |
mitsubishielectric | gx_works2 | * | |
mitsubishielectric | gx_works3 | * | |
mitsubishielectric | iu_configuration_tool | * | |
mitsubishielectric | iu_developer2 | * | |
mitsubishielectric | melsoft_iq_appportal | * | |
mitsubishielectric | melsoft_navigator | * | |
mitsubishielectric | mi_configurator | * | |
mitsubishielectric | mr_configurator2 | * | |
mitsubishielectric | mt_works2 | * | |
mitsubishielectric | mx_component | * | |
mitsubishielectric | rt_toolbox3 | * | |
mitsubishielectric | rd78g4_firmware | * | |
mitsubishielectric | rd78g4 | - | |
mitsubishielectric | rd78g8_firmware | * | |
mitsubishielectric | rd78g8 | - | |
mitsubishielectric | rd78g16_firmware | * | |
mitsubishielectric | rd78g16 | - | |
mitsubishielectric | rd78g32_firmware | * | |
mitsubishielectric | rd78g32 | - | |
mitsubishielectric | rd78g64_firmware | * | |
mitsubishielectric | rd78g64 | - | |
mitsubishielectric | rd78ghv_firmware | * | |
mitsubishielectric | rd78ghv | - | |
mitsubishielectric | rd78ghw_firmware | * | |
mitsubishielectric | rd78ghw | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "892E3CDC-AFC4-4EF1-AF46-3F161603DDB1", "versionEndIncluding": "1.010l", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*", "matchCriteriaId": "87549502-D224-408D-8C66-41F5E8F7743A", "versionEndIncluding": "1.22y", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "015EB163-A5D6-4C55-8038-59823B7FF49F", "versionEndIncluding": "1.595v", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "matchCriteriaId": "AE537EF6-72AE-4091-AF6E-9959C3F45632", "versionEndIncluding": "1.063r", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:iu_configuration_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "83B09E17-9CFF-4231-AE28-FB9D99332BCB", "versionEndIncluding": "1.04", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:iu_developer2:*:*:*:*:*:*:*:*", "matchCriteriaId": "D449D560-C64A-48B0-B1BB-31800FF3062E", "versionEndIncluding": "1.08", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_iq_appportal:*:*:*:*:*:*:*:*", "matchCriteriaId": "8F2EA556-367B-4F32-99D2-C685742CCAEE", "versionEndIncluding": "1.17t", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*", "matchCriteriaId": "FF88C6B0-5641-488E-9AE2-6AF479EB10BF", "versionEndIncluding": "2.70y", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*", "matchCriteriaId": "50DAB8A0-E2F3-496A-B6B6-22E4243D104C", "versionEndIncluding": "1.110q", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "04FF09A2-B1C0-4A65-A420-22A044B7F2CD", "versionEndIncluding": "1.156n", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0C9B5B3-D4F6-4E00-89B4-964516BB989B", "versionEndIncluding": "4.20w", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*", "matchCriteriaId": "463E3740-A618-45A6-9C30-6FBC28077123", "versionEndIncluding": "1.70y", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rd78g4_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BEAB1838-A2E2-4D12-A216-68DD9E4624CF", "versionEndIncluding": "10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rd78g4:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9B1BA74-5B02-400C-AA98-AFB29E848299", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rd78g8_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E213C893-9C88-42C1-BE32-634D7BB84AD6", "versionEndIncluding": "10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rd78g8:-:*:*:*:*:*:*:*", "matchCriteriaId": "8467C47A-2798-43FA-B132-A774B1148FC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rd78g16_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "389EBE60-F4CF-4E82-975D-44DCBAC74929", "versionEndIncluding": "10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rd78g16:-:*:*:*:*:*:*:*", "matchCriteriaId": "5F671BBC-41EE-41FF-87B1-36DBFA7A4BAD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rd78g32_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2325BC60-32F9-46CA-8035-7E88360C15A1", "versionEndIncluding": "10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rd78g32:-:*:*:*:*:*:*:*", "matchCriteriaId": "81DD3BFA-9E3A-4FAB-AB7B-6CC365628877", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rd78g64_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DC759E3E-6D0A-4BA5-AB2E-38947331C5B2", "versionEndIncluding": "10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rd78g64:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0A92E26-C302-4285-BED1-7B8637E252DA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rd78ghv_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D70552B7-C943-43B0-B5BD-ED43A853657E", "versionEndIncluding": "10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rd78ghv:-:*:*:*:*:*:*:*", "matchCriteriaId": "12E5533D-15A8-471B-899B-FE9F9655EE8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rd78ghw_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA2C0DCD-65E6-4B93-B92F-E4FE46CCA58C", "versionEndIncluding": "10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rd78ghw:-:*:*:*:*:*:*:*", "matchCriteriaId": "8B5C3119-7579-4623-8513-65A281BDF0D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code." }, { "lang": "es", "value": "diversos productos de Mitsubishi Electric Factory Automation presentan una vulnerabilidad que permite a un atacante ejecutar c\u00f3digo arbitrario" } ], "id": "CVE-2020-14523", "lastModified": "2024-11-21T05:03:27.300", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.6, "impactScore": 6.0, "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-11T18:15:08.577", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU90224831/" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Patch", "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU90224831/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-02-11 18:15
Modified
2024-11-21 05:03
Severity ?
8.3 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04 | Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
mitsubishielectric | c_controller_interface_module_utility | * | |
mitsubishielectric | c_controller_module_setting_and_monitoring_tool | * | |
mitsubishielectric | cc-link_ie_control_network_data_collector | 1.00a | |
mitsubishielectric | cc-link_ie_field_network_data_collector | 1.00a | |
mitsubishielectric | cc-link_ie_tsn_data_collector | 1.00a | |
mitsubishielectric | cpu_module_logging_configuration_tool | * | |
mitsubishielectric | cw_configurator | * | |
mitsubishielectric | data_transfer | * | |
mitsubishielectric | ezsocket | * | |
mitsubishielectric | fr_configurator_sw3 | * | |
mitsubishielectric | fr_configurator2 | * | |
mitsubishielectric | gt_designer2_classic | * | |
mitsubishielectric | gt_softgot1000 | * | |
mitsubishielectric | gt_softgot2000 | * | |
mitsubishielectric | gx_developer | * | |
mitsubishielectric | gx_logviewer | * | |
mitsubishielectric | gx_works2 | * | |
mitsubishielectric | gx_works3 | * | |
mitsubishielectric | m_commdtm-io-link | * | |
mitsubishielectric | melfa-works | * | |
mitsubishielectric | melsec_wincpu_setting_utility | * | |
mitsubishielectric | melsoft_complete_clean_up_tool | * | |
mitsubishielectric | melsoft_em_software_development_kit | * | |
mitsubishielectric | melsoft_iq_appportal | * | |
mitsubishielectric | melsoft_navigator | * | |
mitsubishielectric | mi_configurator | * | |
mitsubishielectric | motion_control_setting | * | |
mitsubishielectric | motorizer | * | |
mitsubishielectric | mr_configurator2 | * | |
mitsubishielectric | mt_works2 | * | |
mitsubishielectric | mtconnect_data_collector | * | |
mitsubishielectric | mx_component | * | |
mitsubishielectric | mx_mesinterface | * | |
mitsubishielectric | mx_mesinterface-r | * | |
mitsubishielectric | mx_sheet | * | |
mitsubishielectric | position_board_utility_2 | * | |
mitsubishielectric | px_developer | * | |
mitsubishielectric | rt_toolbox2 | * | |
mitsubishielectric | rt_toolbox3 | * | |
mitsubishielectric | setting\/monitoring_tools_for_the_c_controller_module | * | |
mitsubishielectric | slmp_data_collector | * | |
mitsubishielectric | gt_designer3 | * | |
mitsubishielectric | got1000_series_gt10 | - | |
mitsubishielectric | got1000_series_gt11 | - | |
mitsubishielectric | got1000_series_gt12 | - | |
mitsubishielectric | got1000_series_gt14 | - | |
mitsubishielectric | got1000_series_gt15 | - | |
mitsubishielectric | got1000_series_gt16 | - | |
mitsubishielectric | got1000_series_gt21 | - | |
mitsubishielectric | got1000_series_gt23 | - | |
mitsubishielectric | got1000_series_gt25 | - | |
mitsubishielectric | got1000_series_gt27 | - | |
mitsubishielectric | network_interface_board_cc-link_ver.2_utility_firmware | * | |
mitsubishielectric | network_interface_board_cc-link_ver.2_utility | - | |
mitsubishielectric | network_interface_board_cc_ie_control_utility_firmware | * | |
mitsubishielectric | network_interface_board_cc_ie_control_utility | - | |
mitsubishielectric | network_interface_board_cc_ie_field_utility_firmware | * | |
mitsubishielectric | network_interface_board_cc_ie_field_utility | - | |
mitsubishielectric | network_interface_board_mneth_utility_firmware | * | |
mitsubishielectric | network_interface_board_mneth_utility | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mitsubishielectric:c_controller_interface_module_utility:*:*:*:*:*:*:*:*", "matchCriteriaId": "23DA824B-6169-477E-ABE6-251673287DBB", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "4DB4A4DA-DBC0-42A8-B933-933DE45F004D", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:cc-link_ie_control_network_data_collector:1.00a:*:*:*:*:*:*:*", "matchCriteriaId": "147760E8-B888-481C-8669-C989B96CD642", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:cc-link_ie_field_network_data_collector:1.00a:*:*:*:*:*:*:*", "matchCriteriaId": "DD410E22-1E58-412B-8A03-2BDE25714E89", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:cc-link_ie_tsn_data_collector:1.00a:*:*:*:*:*:*:*", "matchCriteriaId": "82B337E7-3656-445B-9EA1-FEFC80C37819", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "EFB022B0-D30E-4EA9-BDB3-BD5784144F45", "versionEndIncluding": "1.100e", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "892E3CDC-AFC4-4EF1-AF46-3F161603DDB1", "versionEndIncluding": "1.010l", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*", "matchCriteriaId": "45BCA319-1B52-468E-BB59-A2AA2C491361", "versionEndIncluding": "3.42u", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0BF4793-8A65-4CB6-9B62-4388CBD84033", "versionEndIncluding": "5.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*", "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*", "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gt_designer2_classic:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B2B348C-0C2E-43A7-A606-102CB0E08B4B", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*", "matchCriteriaId": "F21C6BDF-DD7F-4462-9F74-4A91E4BA936C", "versionEndIncluding": "3.200j", "versionStartIncluding": "3.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEF6E106-73A6-403B-A731-0372521E412D", "versionEndIncluding": "1.241b", "versionStartIncluding": "1.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*", "matchCriteriaId": "5589F3F2-0857-4D95-9F63-EE66452BE566", "versionEndIncluding": "8.504a", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*", "matchCriteriaId": "591B76E1-665F-4473-8A65-B8549B61807F", "versionEndIncluding": "1.100e", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E36C451-A531-4EEB-9574-0AC0116D910D", "versionEndIncluding": "1.601b", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "matchCriteriaId": "AE537EF6-72AE-4091-AF6E-9959C3F45632", "versionEndIncluding": "1.063r", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:*", "matchCriteriaId": "87B55AB8-B00D-4960-9F31-45E1855B109E", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:*", "matchCriteriaId": "4116C452-19C3-4F48-8A05-864BD884BDD0", "versionEndIncluding": "4.4", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsec_wincpu_setting_utility:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C51CF8E-49C1-418C-B410-50B23F9A23D7", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_complete_clean_up_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "A6D30BBF-E50B-4C27-9A33-902D05F987AD", "versionEndIncluding": "1.06g", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_em_software_development_kit:*:*:*:*:*:*:*:*", "matchCriteriaId": "724C0E0B-5658-4040-A925-A07128EAD323", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_iq_appportal:*:*:*:*:*:*:*:*", "matchCriteriaId": "8F2EA556-367B-4F32-99D2-C685742CCAEE", "versionEndIncluding": "1.17t", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC7353B-EFF7-432D-8F88-0D5EBBBBE4C0", "versionEndIncluding": "2.74c", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:motion_control_setting:*:*:*:*:*:*:*:*", "matchCriteriaId": "12866465-10B2-4D45-B693-AE8C0EF34ADF", "versionEndIncluding": "1.005f", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:motorizer:*:*:*:*:*:*:*:*", "matchCriteriaId": "5D82696C-937C-4B49-B748-006A6E836B03", "versionEndIncluding": "1.005f", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*", "matchCriteriaId": "AEDAE974-4101-4B93-8DB5-8E93882AE3C5", "versionEndIncluding": "1.125f", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "57031F64-353E-403C-B7F8-0A145E70CBE7", "versionEndIncluding": "1.167z", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mtconnect_data_collector:*:*:*:*:*:*:*:*", "matchCriteriaId": "2561FAAC-19E7-48EE-AC80-8F9965EB2B2A", "versionEndIncluding": "1.1.4.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0C9B5B3-D4F6-4E00-89B4-964516BB989B", "versionEndIncluding": "4.20w", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mx_mesinterface:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F84606A-A815-4A4C-9B7A-3A47449044D8", "versionEndIncluding": "1.21x", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mx_mesinterface-r:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3CBAD07-E3E5-45C3-9208-B2F891D879F3", "versionEndIncluding": "1.12n", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mx_sheet:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA891D85-4E28-4AA6-8393-5EC58C4BD923", "versionEndIncluding": "2.15r", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:position_board_utility_2:*:*:*:*:*:*:*:*", "matchCriteriaId": "F4AC335D-3FF8-42A6-9567-023248CF7256", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:px_developer:*:*:*:*:*:*:*:*", "matchCriteriaId": "445EF081-A7BB-4568-850F-00CF58060D62", "versionEndIncluding": "1.53f", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:*", "matchCriteriaId": "5BD4EC4A-ACF7-45F2-893D-569B4F8F8909", "versionEndIncluding": "3.73b", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*", "matchCriteriaId": "779B0C13-D3DD-4D27-B18B-C0119B7BC5CB", "versionEndIncluding": "1.82l", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:setting\\/monitoring_tools_for_the_c_controller_module:*:*:*:*:*:*:*:*", "matchCriteriaId": "85CBC7FE-6EF9-4DA5-8128-849233A8DC72", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:slmp_data_collector:*:*:*:*:*:*:*:*", "matchCriteriaId": "8814A8BA-AA54-4270-AAB1-679D0881D715", "versionEndIncluding": "1.04e", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:*", "matchCriteriaId": "45AFD554-F595-4B11-92DC-5655E8203C76", "versionEndIncluding": "1.241b", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt10:-:*:*:*:*:*:*:*", "matchCriteriaId": "70B37C4A-147A-4A7D-8F29-E2C366B54D68", "vulnerable": false }, { "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt11:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AB71211-39CF-4AB7-8D7A-B6FC5C2A9FBC", "vulnerable": false }, { "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt12:-:*:*:*:*:*:*:*", "matchCriteriaId": "8E639243-577F-4787-8724-C1FEC886631D", "vulnerable": false }, { "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt14:-:*:*:*:*:*:*:*", "matchCriteriaId": "D3BD1AB4-3A3D-46CD-B613-3E3613AAA273", "vulnerable": false }, { "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt15:-:*:*:*:*:*:*:*", "matchCriteriaId": "29141984-191A-4A36-996D-9B60830CEA60", "vulnerable": false }, { "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt16:-:*:*:*:*:*:*:*", "matchCriteriaId": "647842FC-AC89-462E-9856-3BB1E469CB52", "vulnerable": false }, { "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt21:-:*:*:*:*:*:*:*", "matchCriteriaId": "4EFBF467-8492-4CFB-8669-424A71B3CBAF", "vulnerable": false }, { "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt23:-:*:*:*:*:*:*:*", "matchCriteriaId": "1379891B-B1EC-433F-918B-8E9A4FBC0352", "vulnerable": false }, { "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt25:-:*:*:*:*:*:*:*", "matchCriteriaId": "5ADE2CDE-AB27-42DD-B4C0-1F4B2F55FE88", "vulnerable": false }, { "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt27:-:*:*:*:*:*:*:*", "matchCriteriaId": "9AD87755-DECB-4007-970F-A082EE983EB6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:network_interface_board_cc-link_ver.2_utility_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5162D96A-EFDD-4679-B9A1-76CDAF00CA58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:network_interface_board_cc-link_ver.2_utility:-:*:*:*:*:*:*:*", "matchCriteriaId": "43223F6D-B64C-49D7-8A04-DDB09B6D698E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:network_interface_board_cc_ie_control_utility_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0FF03D46-5539-432E-B67B-1D4494D3BBD6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:network_interface_board_cc_ie_control_utility:-:*:*:*:*:*:*:*", "matchCriteriaId": "D8ABB436-86C7-49BB-B95B-FD61BE60BAD5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:network_interface_board_cc_ie_field_utility_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "95873A25-2480-45F1-8FE3-D190AE9A824B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:network_interface_board_cc_ie_field_utility:-:*:*:*:*:*:*:*", "matchCriteriaId": "8A756E0D-EB80-4601-B07A-4F5ECD8D424F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:network_interface_board_mneth_utility_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64CEB2D6-0113-47E9-A238-373472907CE5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:network_interface_board_mneth_utility:-:*:*:*:*:*:*:*", "matchCriteriaId": "03EAB2BF-B0EF-4899-BF6D-3C0975462178", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition." }, { "lang": "es", "value": "diversos productos de software de ingenier\u00eda de Mitsubishi Electric Factory Automation presentan una vulnerabilidad de ejecuci\u00f3n de c\u00f3digo malicioso. Un atacante malicioso podr\u00eda usar esta vulnerabilidad para obtener informaci\u00f3n, modificar informaci\u00f3n y causar una condici\u00f3n de denegaci\u00f3n de servicio" } ], "id": "CVE-2020-14521", "lastModified": "2024-11-21T05:03:26.950", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.6, "impactScore": 6.0, "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-11T18:15:08.513", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-428" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-276" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-06-30 11:15
Modified
2024-11-21 05:34
Severity ?
Summary
Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to cause a denial of service (DoS) condition attacks via unspecified vectors.
References
▼ | URL | Tags | |
---|---|---|---|
vultures@jpcert.or.jp | https://jvn.jp/en/vu/JVNVU90307594/index.html | Third Party Advisory | |
vultures@jpcert.or.jp | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf | Mitigation, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://jvn.jp/en/vu/JVNVU90307594/index.html | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf | Mitigation, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
mitsubishielectric | cpu_module_logging_configuration_tool | * | |
mitsubishielectric | cw_configurator | * | |
mitsubishielectric | em_configurator | * | |
mitsubishielectric | gt_designer3 | * | |
mitsubishielectric | gx_logviewer | * | |
mitsubishielectric | gx_works2 | * | |
mitsubishielectric | gx_works3 | * | |
mitsubishielectric | m_commdtm-hart | * | |
mitsubishielectric | m_commdtm-io-link | * | |
mitsubishielectric | melfa-works | * | |
mitsubishielectric | melsec-l_flexible_high-speed_i\/o_control_module_configuration_tool | * | |
mitsubishielectric | melsoft_fielddeviceconfigurator | * | |
mitsubishielectric | melsoft_iq_appportal | * | |
mitsubishielectric | melsoft_navigator | * | |
mitsubishielectric | mi_configurator | * | |
mitsubishielectric | motion_control_setting | * | |
mitsubishielectric | mr_configurator2 | * | |
mitsubishielectric | mt_works2 | * | |
mitsubishielectric | rt_toolbox2 | * | |
mitsubishielectric | rt_toolbox3 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "5AA4BCF9-CE1B-4A53-BBBD-396FE7D8D410", "versionEndIncluding": "1.94y", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "892E3CDC-AFC4-4EF1-AF46-3F161603DDB1", "versionEndIncluding": "1.010l", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:em_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "AD8B6AFD-17BE-4657-9F55-B0CA52E2578A", "versionEndIncluding": "1.010l", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:*", "matchCriteriaId": "567CE406-0FCE-44DC-B210-1E54EDB6FE11", "versionEndIncluding": "1.221f", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*", "matchCriteriaId": "591B76E1-665F-4473-8A65-B8549B61807F", "versionEndIncluding": "1.100e", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "7CCB1E6D-333D-458E-AE2D-974E16195811", "versionEndIncluding": "1.590q", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "matchCriteriaId": "20F14A8B-E42D-4621-8BCC-A6D28A8A0D7A", "versionEndIncluding": "1.060n", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:*", "matchCriteriaId": "35D76E9B-394E-47A1-B6F1-4854909A8D59", "versionEndIncluding": "1.01b", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:*", "matchCriteriaId": "37B4823F-E257-4CFF-A20B-FAB4A60D49D9", "versionEndIncluding": "1.03d", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:*", "matchCriteriaId": "4116C452-19C3-4F48-8A05-864BD884BDD0", "versionEndIncluding": "4.4", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsec-l_flexible_high-speed_i\\/o_control_module_configuration_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "BB41FBDD-2785-4012-AB84-2B1F947E9512", "versionEndIncluding": "1.005f", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_fielddeviceconfigurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "6DBBC676-19E1-4780-8D23-6888884E67A4", "versionEndIncluding": "1.04e", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_iq_appportal:*:*:*:*:*:*:*:*", "matchCriteriaId": "56B1A257-F1C6-4213-92A0-7476E3EB6207", "versionEndIncluding": "1.14q", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*", "matchCriteriaId": "76A6CCE9-ACB8-4A24-A4E5-0F8DCBC4475B", "versionEndIncluding": "2.62q", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "DA012067-3CF9-46E8-9C5D-C64D92C2574D", "versionEndIncluding": "1.004e", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:motion_control_setting:*:*:*:*:*:*:*:*", "matchCriteriaId": "19CEBFB8-E23E-4ABB-9337-221D6749D456", "versionEndIncluding": "1.006g", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*", "matchCriteriaId": "6998E84B-0EFC-4ACB-BFC6-FFC1A675F1B3", "versionEndIncluding": "1.100e", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "0303271B-F016-4D0E-A862-313A31B8CD60", "versionEndIncluding": "1.160s", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:*", "matchCriteriaId": "5BD4EC4A-ACF7-45F2-893D-569B4F8F8909", "versionEndIncluding": "3.73b", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*", "matchCriteriaId": "5E66C5F1-23BF-42F9-8A25-FE8A7E66B07D", "versionEndIncluding": "1.60n", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to cause a denial of service (DoS) condition attacks via unspecified vectors." }, { "lang": "es", "value": "Una vulnerabilidad de consumo de recursos no controlado en Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Versiones 1.94Y y anteriores, CW Configurator Versiones 1.010L y anteriores, EM Software Development Kit (EM Configurator) Versiones 1.010L y anteriores, GT Designer3 (GOT2000) Versiones 1.221F y anteriores, GX LogViewer Versiones 1.96A y anteriores, GX Works2 Versiones 1.586L y anteriores, GX Works3 Versiones 1.058L y anteriores, M_CommDTM-HART Versiones 1.00A, M_CommDTM-IO-Link Versiones 1.02C y anteriores, MELFA-Works Versiones 4.3 y anteriores, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Versiones 1.004E y anteriores, MELSOFT FieldDeviceConfigurator Versiones 1.03D y anteriores, MELSOFT iQ AppPortal Versiones 1.11M y anteriores, MELSOFT Navigator Versiones 2.58L y anteriores, MI Configurator Versiones 1.003D y anteriores, Motion Control Setting Versiones 1.005F y anteriores, MR Configurator2 Versiones 1.72A y anteriores, MT Works2 Versiones 1.156N y anteriores , RT ToolBox2 Versiones 3.72A y anteriores, y RT ToolBox3 Versiones 1.50C y anteriores, permite a un atacante causar ataques de condici\u00f3n de denegaci\u00f3n de servicio (DoS) por medio de vectores no especificados" } ], "id": "CVE-2020-5603", "lastModified": "2024-11-21T05:34:20.803", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-30T11:15:11.397", "references": [ { "source": "vultures@jpcert.or.jp", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html" }, { "source": "vultures@jpcert.or.jp", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf" } ], "sourceIdentifier": "vultures@jpcert.or.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-02-19 20:15
Modified
2024-11-21 05:46
Severity ?
Summary
Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
References
▼ | URL | Tags | |
---|---|---|---|
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://jvn.jp/vu/JVNVU92330101/index.html | Third Party Advisory | |
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02 | ||
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://jvn.jp/vu/JVNVU92330101/index.html | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02 | ||
af854a3a-2127-422b-91ae-364da2661108 | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
mitsubishielectric | c_controller_module_setting_and_monitoring_tool | * | |
mitsubishielectric | cpu_module_logging_configuration_tool | * | |
mitsubishielectric | cw_configurator | * | |
mitsubishielectric | data_transfer | * | |
mitsubishielectric | ezsocket | * | |
mitsubishielectric | fr_configurator | * | |
mitsubishielectric | fr_configurator_sw3 | * | |
mitsubishielectric | fr_configurator2 | * | |
mitsubishielectric | gt_designer3 | * | |
mitsubishielectric | gt_softgot1000 | * | |
mitsubishielectric | gt_softgot2000 | * | |
mitsubishielectric | gx_configurator-dp | * | |
mitsubishielectric | gx_configurator-qp | * | |
mitsubishielectric | gx_developer | * | |
mitsubishielectric | gx_explorer | * | |
mitsubishielectric | gx_iec_developer | * | |
mitsubishielectric | gx_logviewer | * | |
mitsubishielectric | gx_remoteservice-i | * | |
mitsubishielectric | gx_works2 | * | |
mitsubishielectric | gx_works3 | * | |
mitsubishielectric | iq_monozukuri_andon | - | |
mitsubishielectric | iq_monozukuri_process_remote_monitoring | - | |
mitsubishielectric | m_commdtm-hart | * | |
mitsubishielectric | m_commdtm-io-link | * | |
mitsubishielectric | melfa-works | * | |
mitsubishielectric | melsec_wincpu_setting_utility | * | |
mitsubishielectric | melsoft_em_software_development_kit | * | |
mitsubishielectric | melsoft_navigator | * | |
mitsubishielectric | mh11_settingtool_version2 | * | |
mitsubishielectric | mi_configurator | * | |
mitsubishielectric | mt_works2 | * | |
mitsubishielectric | mx_component | * | |
mitsubishielectric | network_interface_board_cc-link | * | |
mitsubishielectric | network_interface_board_cc_ie_control_utility | * | |
mitsubishielectric | network_interface_board_cc_ie_field_utility | * | |
mitsubishielectric | network_interface_board_mneth_utility | * | |
mitsubishielectric | px_developer | * | |
mitsubishielectric | rt_toolbox2 | * | |
mitsubishielectric | rt_toolbox3 | * | |
mitsubishielectric | setting\/monitoring_tools_for_the_c_controller_module | * | |
mitsubishielectric | slmp_data_collector | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "4DB4A4DA-DBC0-42A8-B933-933DE45F004D", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "D83BA6D0-2A25-4DDA-B7BA-DE11FA55D276", "versionEndIncluding": "1.112r", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "91D2BDFB-0A0A-4A1B-8671-8B5D652253DE", "versionEndIncluding": "1.011m", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*", "matchCriteriaId": "6AF9A2A7-6F9E-4CA9-8485-3AF83A6411DD", "versionEndIncluding": "3.44w", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*", "matchCriteriaId": "C6E4BC24-6583-4791-9ED9-D2D675187DCD", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "1773F87D-7E58-4E00-90B7-92BDDB4AA3BF", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*", "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*", "matchCriteriaId": "18E81D47-F88A-481B-98E0-56C52CDF6C8B", "versionEndIncluding": "1.24a", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:*", "matchCriteriaId": "66DEB37E-A837-4A2F-9660-7DE8441004D7", "versionEndIncluding": "1.250l", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*", "matchCriteriaId": "B835ECE8-6923-47DF-9BB8-E0AA8D77228D", "versionEndIncluding": "3.245f", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*", "matchCriteriaId": "92C96AF0-1DCE-4769-AAC4-422F8B411A2A", "versionEndIncluding": "1.250l", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_configurator-dp:*:*:*:*:*:*:*:*", "matchCriteriaId": "E767C69A-23D9-4C67-AA66-392D5E70ED7B", "versionEndIncluding": "7.14q", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_configurator-qp:*:*:*:*:*:*:*:*", "matchCriteriaId": "492299CE-FE94-4CB4-9D62-03F05CBCDE74", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*", "matchCriteriaId": "C4588898-2ABA-4AA3-A33F-551387DC84AC", "versionEndIncluding": "8.506c", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_explorer:*:*:*:*:*:*:*:*", "matchCriteriaId": "18A18533-FF83-4C7C-839D-077A7523DBDC", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_iec_developer:*:*:*:*:*:*:*:*", "matchCriteriaId": "974700B4-FC0B-4097-8826-CE055E13434F", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FFEE46E-C37D-4E82-BDC5-1225C03BFFFE", "versionEndIncluding": "1.115u", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_remoteservice-i:*:*:*:*:*:*:*:*", "matchCriteriaId": "C4DAEEF5-50CA-4DCD-8B1A-BAE8DEEA23AA", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "76E34DC3-5D48-49DB-B1CB-CB5BDDED169D", "versionEndIncluding": "1.597x", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "matchCriteriaId": "920FC6C1-32FA-4251-81AA-B76D353B216A", "versionEndIncluding": "1.070y", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:iq_monozukuri_andon:-:*:*:*:*:*:*:*", "matchCriteriaId": "07756207-64DF-4F89-B3A1-19086CCC42BB", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:iq_monozukuri_process_remote_monitoring:-:*:*:*:*:*:*:*", "matchCriteriaId": "978160CD-B7D4-4494-A5BB-CA0195441985", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:*", "matchCriteriaId": "EBC92717-C371-42B4-8AA6-73E14B60A87E", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:*", "matchCriteriaId": "87B55AB8-B00D-4960-9F31-45E1855B109E", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:*", "matchCriteriaId": "4116C452-19C3-4F48-8A05-864BD884BDD0", "versionEndIncluding": "4.4", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsec_wincpu_setting_utility:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C51CF8E-49C1-418C-B410-50B23F9A23D7", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_em_software_development_kit:*:*:*:*:*:*:*:*", "matchCriteriaId": "724C0E0B-5658-4040-A925-A07128EAD323", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC7353B-EFF7-432D-8F88-0D5EBBBBE4C0", "versionEndIncluding": "2.74c", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mh11_settingtool_version2:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8D3CBAF-5876-4DCE-908F-CCA8B0DDDB75", "versionEndIncluding": "2.004e", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "57031F64-353E-403C-B7F8-0A145E70CBE7", "versionEndIncluding": "1.167z", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B623A09-688E-49B1-99EF-CFA8DADC79E8", "versionEndIncluding": "5.001b", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc-link:*:*:*:*:*:*:*:*", "matchCriteriaId": "87A92A26-7148-4A2A-BAFA-5F819468F48E", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_control_utility:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D02C00E-B8C6-4987-8F25-E3D46FEDB44A", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_field_utility:*:*:*:*:*:*:*:*", "matchCriteriaId": "07F71BF3-FC69-4DA3-9989-DA269B557085", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_mneth_utility:*:*:*:*:*:*:*:*", "matchCriteriaId": "171CD9BC-2A02-4ACA-B29C-332094AA3EDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:px_developer:*:*:*:*:*:*:*:*", "matchCriteriaId": "445EF081-A7BB-4568-850F-00CF58060D62", "versionEndIncluding": "1.53f", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:*", "matchCriteriaId": "5BD4EC4A-ACF7-45F2-893D-569B4F8F8909", "versionEndIncluding": "3.73b", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*", "matchCriteriaId": "779B0C13-D3DD-4D27-B18B-C0119B7BC5CB", "versionEndIncluding": "1.82l", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:setting\\/monitoring_tools_for_the_c_controller_module:*:*:*:*:*:*:*:*", "matchCriteriaId": "85CBC7FE-6EF9-4DA5-8128-849233A8DC72", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:slmp_data_collector:*:*:*:*:*:*:*:*", "matchCriteriaId": "8814A8BA-AA54-4270-AAB1-679D0881D715", "versionEndIncluding": "1.04e", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets." }, { "lang": "es", "value": "Manejo inadecuado de la vulnerabilidad de inconsistencia de par\u00e1metros de longitud en el software de ingenier\u00eda FA de Mitsubishi Electric (Herramienta de configuraci\u00f3n de registro del m\u00f3dulo de la CPU versiones 1.112R y anteriores, Configurador CW versiones 1.011M y anteriores, Transferencia de datos versiones 3.44W y anteriores, EZSocket versiones 5.4 y anteriores, Configurador FR todas las versiones, Configurador FR SW3 todas las versiones, Configurador FR2 versiones 1. 24A y anteriores, GT Designer3 Versi\u00f3n1(GOT1000) versiones 1.250L y anteriores, GT Designer3 Versi\u00f3n1(GOT2000) versiones 1.250L y anteriores, GT SoftGOT1000 Versi\u00f3n3 versiones 3.245F y anteriores, GT SoftGOT2000 Versi\u00f3n1 versiones 1.250L y anteriores, GX Configurator-DP versiones 7.14Q y anteriores, GX Configurator-QP todas las versiones, GX Developer versiones 8.506C y anteriores, GX Explorer todas las versiones, GX IEC Developer todas las versiones, GX LogViewer versiones 1. 115U y anteriores, GX RemoteService-I todas las versiones, GX Works2 versiones 1.597X y anteriores, GX Works3 versiones 1.070Y y anteriores, iQ Monozukuri ANDON (Data Transfer) todas las versiones, iQ Monozukuri Process Remote Monitoring (Data Transfer) todas las versiones, M_CommDTM-HART todas las versiones, M_CommDTM-IO-Link versiones 1. 03D y anteriores, MELFA-Works versiones 4.4 y anteriores, MELSEC WinCPU Setting Utility todas las versiones, MELSOFT EM Software Development Kit (EM Configurator) versiones 1. 015R y anteriores, MELSOFT Navigator versiones 2.74C y anteriores, MH11 SettingTool Version2 versiones 2.004E y anteriores, MI Configurator versiones 1.004E y anteriores, MT Works2 versiones 1.167Z y anteriores, MX Component versiones 5.001B y anteriores, Network Interface Board CC IE Control utility versiones 1.29F y anteriores, Network Interface Board CC IE Field Utility versiones 1.16S y anteriores, Network Interface Board CC-Link Ver.2 1.23Z y anteriores, Network Interface Board MNETH utility versions 34L y anteriores, PX Developer versions 1.53F y anteriores, RT ToolBox2 versions 3.73B y anteriores, RT ToolBox3 versions 1.82L y anteriores, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N y anteriores y SLMP Data Collector versions 1. 04E y anteriores) permite que un atacante remoto no autenticado provoque una condici\u00f3n de denegaci\u00f3n de servicio de los productos de software, y posiblemente ejecute un programa malicioso en el ordenador personal que ejecuta los productos de software, aunque no se ha reproducido, mediante la suplantaci\u00f3n de MELSEC, GOT o FREQROL y el retorno de paquetes de respuesta manipulados" } ], "id": "CVE-2021-20588", "lastModified": "2024-11-21T05:46:49.790", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-02-19T20:15:13.023", "references": [ { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU92330101/index.html" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU92330101/index.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf" } ], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-01-30 09:15
Modified
2024-11-21 08:44
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Summary
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally.
References
▼ | URL | Tags | |
---|---|---|---|
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://jvn.jp/vu/JVNVU95103362 | Third Party Advisory | |
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02 | Third Party Advisory, US Government Resource | |
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://jvn.jp/vu/JVNVU95103362 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
mitsubishielectric | ezsocket | * | |
mitsubishielectric | fr_configurator2 | * | |
mitsubishielectric | got1000 | * | |
mitsubishielectric | got2000 | * | |
mitsubishielectric | gx_works2 | * | |
mitsubishielectric | gx_works3 | * | |
mitsubishielectric | mc_works64 | * | |
mitsubishielectric | melsoft_navigator | * | |
mitsubishielectric | mt_works2 | * | |
mitsubishielectric | mx_component | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*", "matchCriteriaId": "C6096E48-9ECD-48FF-9F5E-D182E42D41C9", "versionStartIncluding": "3.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*", "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:got1000:*:*:*:*:*:*:*:*", "matchCriteriaId": "C31EFBDE-DE71-46F3-97A1-CABC037FC31D", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:got2000:*:*:*:*:*:*:*:*", "matchCriteriaId": "5D887323-BBDD-41ED-82B8-66DE412666F5", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "B73766EB-FF3E-495E-B1C1-5D49A1569696", "versionStartIncluding": "1.11m", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5790F2E-5511-46F6-94E5-F3E1A2367662", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F3C096D-D510-46F4-B46A-A234CA630227", "versionStartIncluding": "1.04e", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "0EC0ACF4-C303-4EC0-A755-1F9AE4152DDB", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*", "matchCriteriaId": "407781DB-9AF9-4E3A-BF24-1787ADB33F42", "versionStartIncluding": "4.00a", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally." }, { "lang": "es", "value": "Autenticaci\u00f3n faltante para vulnerabilidad de funci\u00f3n cr\u00edtica en Mitsubishi Electric Corporation EZSocket versiones 3.0 y posteriores, FR Configurator2 todas las versiones, GT Designer3 Versi\u00f3n1(GOT1000) todas las versiones, GT Designer3 Versi\u00f3n1(GOT2000) todas las versiones, GX Works2 versiones 1.11M y posteriores, GX Works3 todas versiones, MELSOFT Navigator versiones 1.04E y posteriores, MT Works2 todas las versiones, MX Component versiones 4.00A y posteriores y MX OPC Server DA/UA todas las versiones permiten a un atacante remoto no autenticado eludir la autenticaci\u00f3n enviando paquetes especialmente manipulados y conect\u00e1ndose a los productos ilegalmente." } ], "id": "CVE-2023-6942", "lastModified": "2024-11-21T08:44:53.183", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-01-30T09:15:47.757", "references": [ { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU95103362" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU95103362" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf" } ], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-02-19 20:15
Modified
2024-11-21 05:46
Severity ?
Summary
Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
References
▼ | URL | Tags | |
---|---|---|---|
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://jvn.jp/vu/JVNVU92330101/index.html | Third Party Advisory | |
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02 | Third Party Advisory, US Government Resource | |
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://jvn.jp/vu/JVNVU92330101/index.html | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
mitsubishielectric | c_controller_module_setting_and_monitoring_tool | * | |
mitsubishielectric | cpu_module_logging_configuration_tool | * | |
mitsubishielectric | cw_configurator | * | |
mitsubishielectric | data_transfer | * | |
mitsubishielectric | ezsocket | * | |
mitsubishielectric | fr_configurator | * | |
mitsubishielectric | fr_configurator_sw3 | * | |
mitsubishielectric | fr_configurator2 | * | |
mitsubishielectric | gt_designer3 | * | |
mitsubishielectric | gt_softgot1000 | * | |
mitsubishielectric | gt_softgot2000 | * | |
mitsubishielectric | gx_configurator-dp | * | |
mitsubishielectric | gx_configurator-qp | * | |
mitsubishielectric | gx_developer | * | |
mitsubishielectric | gx_explorer | * | |
mitsubishielectric | gx_iec_developer | * | |
mitsubishielectric | gx_logviewer | * | |
mitsubishielectric | gx_remoteservice-i | * | |
mitsubishielectric | gx_works2 | * | |
mitsubishielectric | gx_works3 | * | |
mitsubishielectric | iq_monozukuri_andon | - | |
mitsubishielectric | iq_monozukuri_process_remote_monitoring | - | |
mitsubishielectric | m_commdtm-hart | * | |
mitsubishielectric | m_commdtm-io-link | * | |
mitsubishielectric | melfa-works | * | |
mitsubishielectric | melsec_wincpu_setting_utility | * | |
mitsubishielectric | melsoft_em_software_development_kit | * | |
mitsubishielectric | melsoft_navigator | * | |
mitsubishielectric | mh11_settingtool_version2 | * | |
mitsubishielectric | mi_configurator | * | |
mitsubishielectric | mt_works2 | * | |
mitsubishielectric | mx_component | * | |
mitsubishielectric | network_interface_board_cc-link | * | |
mitsubishielectric | network_interface_board_cc_ie_control_utility | * | |
mitsubishielectric | network_interface_board_cc_ie_field_utility | * | |
mitsubishielectric | network_interface_board_mneth_utility | * | |
mitsubishielectric | px_developer | * | |
mitsubishielectric | rt_toolbox2 | * | |
mitsubishielectric | rt_toolbox3 | * | |
mitsubishielectric | setting\/monitoring_tools_for_the_c_controller_module | * | |
mitsubishielectric | slmp_data_collector | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "4DB4A4DA-DBC0-42A8-B933-933DE45F004D", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "D83BA6D0-2A25-4DDA-B7BA-DE11FA55D276", "versionEndIncluding": "1.112r", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "91D2BDFB-0A0A-4A1B-8671-8B5D652253DE", "versionEndIncluding": "1.011m", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*", "matchCriteriaId": "6AF9A2A7-6F9E-4CA9-8485-3AF83A6411DD", "versionEndIncluding": "3.44w", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*", "matchCriteriaId": "C6E4BC24-6583-4791-9ED9-D2D675187DCD", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "1773F87D-7E58-4E00-90B7-92BDDB4AA3BF", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*", "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*", "matchCriteriaId": "18E81D47-F88A-481B-98E0-56C52CDF6C8B", "versionEndIncluding": "1.24a", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:*", "matchCriteriaId": "66DEB37E-A837-4A2F-9660-7DE8441004D7", "versionEndIncluding": "1.250l", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*", "matchCriteriaId": "B835ECE8-6923-47DF-9BB8-E0AA8D77228D", "versionEndIncluding": "3.245f", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*", "matchCriteriaId": "92C96AF0-1DCE-4769-AAC4-422F8B411A2A", "versionEndIncluding": "1.250l", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_configurator-dp:*:*:*:*:*:*:*:*", "matchCriteriaId": "E767C69A-23D9-4C67-AA66-392D5E70ED7B", "versionEndIncluding": "7.14q", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_configurator-qp:*:*:*:*:*:*:*:*", "matchCriteriaId": "492299CE-FE94-4CB4-9D62-03F05CBCDE74", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*", "matchCriteriaId": "C4588898-2ABA-4AA3-A33F-551387DC84AC", "versionEndIncluding": "8.506c", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_explorer:*:*:*:*:*:*:*:*", "matchCriteriaId": "18A18533-FF83-4C7C-839D-077A7523DBDC", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_iec_developer:*:*:*:*:*:*:*:*", "matchCriteriaId": "974700B4-FC0B-4097-8826-CE055E13434F", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FFEE46E-C37D-4E82-BDC5-1225C03BFFFE", "versionEndIncluding": "1.115u", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_remoteservice-i:*:*:*:*:*:*:*:*", "matchCriteriaId": "C4DAEEF5-50CA-4DCD-8B1A-BAE8DEEA23AA", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "76E34DC3-5D48-49DB-B1CB-CB5BDDED169D", "versionEndIncluding": "1.597x", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "matchCriteriaId": "920FC6C1-32FA-4251-81AA-B76D353B216A", "versionEndIncluding": "1.070y", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:iq_monozukuri_andon:-:*:*:*:*:*:*:*", "matchCriteriaId": "07756207-64DF-4F89-B3A1-19086CCC42BB", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:iq_monozukuri_process_remote_monitoring:-:*:*:*:*:*:*:*", "matchCriteriaId": "978160CD-B7D4-4494-A5BB-CA0195441985", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:*", "matchCriteriaId": "EBC92717-C371-42B4-8AA6-73E14B60A87E", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:*", "matchCriteriaId": "87B55AB8-B00D-4960-9F31-45E1855B109E", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:*", "matchCriteriaId": "4116C452-19C3-4F48-8A05-864BD884BDD0", "versionEndIncluding": "4.4", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsec_wincpu_setting_utility:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C51CF8E-49C1-418C-B410-50B23F9A23D7", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_em_software_development_kit:*:*:*:*:*:*:*:*", "matchCriteriaId": "724C0E0B-5658-4040-A925-A07128EAD323", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC7353B-EFF7-432D-8F88-0D5EBBBBE4C0", "versionEndIncluding": "2.74c", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mh11_settingtool_version2:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8D3CBAF-5876-4DCE-908F-CCA8B0DDDB75", "versionEndIncluding": "2.004e", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "57031F64-353E-403C-B7F8-0A145E70CBE7", "versionEndIncluding": "1.167z", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B623A09-688E-49B1-99EF-CFA8DADC79E8", "versionEndIncluding": "5.001b", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc-link:*:*:*:*:*:*:*:*", "matchCriteriaId": "87A92A26-7148-4A2A-BAFA-5F819468F48E", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_control_utility:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D02C00E-B8C6-4987-8F25-E3D46FEDB44A", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_field_utility:*:*:*:*:*:*:*:*", "matchCriteriaId": "07F71BF3-FC69-4DA3-9989-DA269B557085", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_mneth_utility:*:*:*:*:*:*:*:*", "matchCriteriaId": "171CD9BC-2A02-4ACA-B29C-332094AA3EDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:px_developer:*:*:*:*:*:*:*:*", "matchCriteriaId": "445EF081-A7BB-4568-850F-00CF58060D62", "versionEndIncluding": "1.53f", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:*", "matchCriteriaId": "5BD4EC4A-ACF7-45F2-893D-569B4F8F8909", "versionEndIncluding": "3.73b", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*", "matchCriteriaId": "779B0C13-D3DD-4D27-B18B-C0119B7BC5CB", "versionEndIncluding": "1.82l", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:setting\\/monitoring_tools_for_the_c_controller_module:*:*:*:*:*:*:*:*", "matchCriteriaId": "85CBC7FE-6EF9-4DA5-8128-849233A8DC72", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:slmp_data_collector:*:*:*:*:*:*:*:*", "matchCriteriaId": "8814A8BA-AA54-4270-AAB1-679D0881D715", "versionEndIncluding": "1.04e", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets." }, { "lang": "es", "value": "Vulnerabilidad de desbordamiento de b\u00fafer basada en Heap en el software de ingenier\u00eda de Mitsubishi Electric FA (CPU Module Logging Configuration Tool versiones 1.112R y anteriores, CW Configurator versiones 1.011M y anteriores, Data Transfer versiones 3.44W y anteriores, EZSocket versiones 5.4 y anteriores, FR Configurator todas las versiones, FR Configurator SW3 todas las versiones, FR Configurator2 versiones 1.24A y anteriores, GT Designer3 Version1(GOT1000) versiones 1. 250L y anteriores, GT Designer3 Version1(GOT2000) versiones 1.250L y anteriores, GT SoftGOT1000 Version3 versiones 3.245F y anteriores, GT SoftGOT2000 Version1 versiones 1.250L y anteriores, GX Configurator-DP versiones 7. 14Q y anteriores, GX Configurator-QP todas las versiones, GX Developer versiones 8.506C y anteriores, GX Explorer todas las versiones, GX IEC Developer todas las versiones, GX LogViewer versiones 1.115U y anteriores, GX RemoteService-I todas las versiones, GX Works2 versiones 1. 597X y anteriores, GX Works3 versiones 1.070Y y anteriores, iQ Monozukuri ANDON (Data Transfer) todas las versiones, iQ Monozukuri Process Remote Monitoring (Data Transfer) todas las versiones, M_CommDTM-HART todas las versiones, M_CommDTM-IO-Link versiones 1.03D y anteriores, MELFA-Works versiones 4.4 y anteriores, MELSEC WinCPU Setting Utility todas las versiones, MELSOFT EM Software Development Kit (EM Configurator) versiones 1. 015R y anteriores, MELSOFT Navigator versiones 2.74C y anteriores, MH11 SettingTool Version2 versiones 2.004E y anteriores, MI Configurator versiones 1.004E y anteriores, MT Works2 versiones 1.167Z y anteriores, MX Component versiones 5.001B y anteriores, Network Interface Board CC IE Control utility versiones 1.29F y anteriores, Network Interface Board CC IE Field Utility versiones 1.16S y anteriores, Network Interface Board CC-Link Ver.2 1.23Z y anteriores, Network Interface Board MNETH utility versions 34L y anteriores, PX Developer versions 1.53F y anteriores, RT ToolBox2 versions 3.73B y anteriores, RT ToolBox3 versions 1.82L y anteriores, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N y anteriores y SLMP Data Collector versions 1. 04E y anteriores) permite que un atacante remoto no autenticado provoque una condici\u00f3n de denegaci\u00f3n de servicio de los productos de software, y posiblemente ejecute un programa malicioso en el ordenador personal que ejecuta los productos de software, aunque no se ha reproducido, mediante la suplantaci\u00f3n de MELSEC, GOT o FREQROL y el retorno de paquetes de respuesta manipulados" } ], "id": "CVE-2021-20587", "lastModified": "2024-11-21T05:46:49.637", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-02-19T20:15:12.833", "references": [ { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU92330101/index.html" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU92330101/index.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf" } ], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-06-30 11:15
Modified
2024-11-21 05:34
Severity ?
Summary
Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to conduct XML External Entity (XXE) attacks via unspecified vectors.
References
▼ | URL | Tags | |
---|---|---|---|
vultures@jpcert.or.jp | https://jvn.jp/en/vu/JVNVU90307594/index.html | Third Party Advisory | |
vultures@jpcert.or.jp | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf | Mitigation, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://jvn.jp/en/vu/JVNVU90307594/index.html | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf | Mitigation, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
mitsubishielectric | cpu_module_logging_configuration_tool | * | |
mitsubishielectric | cw_configurator | * | |
mitsubishielectric | em_configurator | * | |
mitsubishielectric | gt_designer3 | * | |
mitsubishielectric | gx_logviewer | * | |
mitsubishielectric | gx_works2 | * | |
mitsubishielectric | gx_works3 | * | |
mitsubishielectric | m_commdtm-hart | * | |
mitsubishielectric | m_commdtm-io-link | * | |
mitsubishielectric | melfa-works | * | |
mitsubishielectric | melsec-l_flexible_high-speed_i\/o_control_module_configuration_tool | * | |
mitsubishielectric | melsoft_fielddeviceconfigurator | * | |
mitsubishielectric | melsoft_iq_appportal | * | |
mitsubishielectric | melsoft_navigator | * | |
mitsubishielectric | mi_configurator | * | |
mitsubishielectric | motion_control_setting | * | |
mitsubishielectric | mr_configurator2 | * | |
mitsubishielectric | mt_works2 | * | |
mitsubishielectric | rt_toolbox2 | * | |
mitsubishielectric | rt_toolbox3 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "5AA4BCF9-CE1B-4A53-BBBD-396FE7D8D410", "versionEndIncluding": "1.94y", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "892E3CDC-AFC4-4EF1-AF46-3F161603DDB1", "versionEndIncluding": "1.010l", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:em_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "AD8B6AFD-17BE-4657-9F55-B0CA52E2578A", "versionEndIncluding": "1.010l", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:*", "matchCriteriaId": "567CE406-0FCE-44DC-B210-1E54EDB6FE11", "versionEndIncluding": "1.221f", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*", "matchCriteriaId": "591B76E1-665F-4473-8A65-B8549B61807F", "versionEndIncluding": "1.100e", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "7CCB1E6D-333D-458E-AE2D-974E16195811", "versionEndIncluding": "1.590q", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "matchCriteriaId": "20F14A8B-E42D-4621-8BCC-A6D28A8A0D7A", "versionEndIncluding": "1.060n", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:*", "matchCriteriaId": "35D76E9B-394E-47A1-B6F1-4854909A8D59", "versionEndIncluding": "1.01b", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:*", "matchCriteriaId": "37B4823F-E257-4CFF-A20B-FAB4A60D49D9", "versionEndIncluding": "1.03d", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:*", "matchCriteriaId": "4116C452-19C3-4F48-8A05-864BD884BDD0", "versionEndIncluding": "4.4", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsec-l_flexible_high-speed_i\\/o_control_module_configuration_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "BB41FBDD-2785-4012-AB84-2B1F947E9512", "versionEndIncluding": "1.005f", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_fielddeviceconfigurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "6DBBC676-19E1-4780-8D23-6888884E67A4", "versionEndIncluding": "1.04e", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_iq_appportal:*:*:*:*:*:*:*:*", "matchCriteriaId": "56B1A257-F1C6-4213-92A0-7476E3EB6207", "versionEndIncluding": "1.14q", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*", "matchCriteriaId": "76A6CCE9-ACB8-4A24-A4E5-0F8DCBC4475B", "versionEndIncluding": "2.62q", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "DA012067-3CF9-46E8-9C5D-C64D92C2574D", "versionEndIncluding": "1.004e", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:motion_control_setting:*:*:*:*:*:*:*:*", "matchCriteriaId": "19CEBFB8-E23E-4ABB-9337-221D6749D456", "versionEndIncluding": "1.006g", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*", "matchCriteriaId": "6998E84B-0EFC-4ACB-BFC6-FFC1A675F1B3", "versionEndIncluding": "1.100e", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "0303271B-F016-4D0E-A862-313A31B8CD60", "versionEndIncluding": "1.160s", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:*", "matchCriteriaId": "5BD4EC4A-ACF7-45F2-893D-569B4F8F8909", "versionEndIncluding": "3.73b", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*", "matchCriteriaId": "5E66C5F1-23BF-42F9-8A25-FE8A7E66B07D", "versionEndIncluding": "1.60n", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to conduct XML External Entity (XXE) attacks via unspecified vectors." }, { "lang": "es", "value": "Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Versiones 1.94Y y anteriores, Configurador CW Versiones 1.010L y anteriores, EM Software Development Kit (Configurador EM) Versiones 1.010L y anteriores, GT Designer3 (GOT2000) Versiones 1.221 F y anteriores, GX LogViewer Versiones 1.96A y anteriores, GX Works2 Versiones 1.586L y anteriores, GX Works3 Versiones 1.058L y anteriores, M_CommDTM-HART Versiones 1.00A, M_CommDTM-IO-Link Versiones 1.02C y anteriores , MELFA-Works Versiones 4.3 y anteriores, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Versiones 1.004E y anteriores, MELSOFT FieldDeviceConfigurator Versiones 1.03D y anteriores, MELSOFT iQ AppPortal Versiones 1.11M y anteriores, MELSOFT Navigator Versiones 2.58L y anteriores, MI Configurator Versiones 1.003D y anteriores, Motion Control Setting Versiones 1.005F y anteriores, MR Configurator2 Versiones 1.72A y anteriores, MT Works2 Versiones 1.156N y anteriores, RT ToolBox2 Versiones 3.72A y anteriores, y RT ToolBox3 Versiones 1.50C y anteriores, permite a un atacante conducir ataques de tipo XML External Entity (XXE) por medio de vectores no especificados" } ], "id": "CVE-2020-5602", "lastModified": "2024-11-21T05:34:20.697", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-30T11:15:11.333", "references": [ { "source": "vultures@jpcert.or.jp", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html" }, { "source": "vultures@jpcert.or.jp", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf" } ], "sourceIdentifier": "vultures@jpcert.or.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-611" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-01-30 09:15
Modified
2024-11-21 08:44
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.
References
▼ | URL | Tags | |
---|---|---|---|
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://jvn.jp/vu/JVNVU95103362 | Third Party Advisory | |
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02 | Third Party Advisory, US Government Resource | |
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://jvn.jp/vu/JVNVU95103362 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
mitsubishielectric | ezsocket | * | |
mitsubishielectric | fr_configurator2 | * | |
mitsubishielectric | got1000 | * | |
mitsubishielectric | got2000 | * | |
mitsubishielectric | gx_works2 | * | |
mitsubishielectric | gx_works3 | * | |
mitsubishielectric | mc_works64 | * | |
mitsubishielectric | melsoft_navigator | * | |
mitsubishielectric | mt_works2 | * | |
mitsubishielectric | mx_component | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*", "matchCriteriaId": "C6096E48-9ECD-48FF-9F5E-D182E42D41C9", "versionStartIncluding": "3.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*", "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:got1000:*:*:*:*:*:*:*:*", "matchCriteriaId": "C31EFBDE-DE71-46F3-97A1-CABC037FC31D", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:got2000:*:*:*:*:*:*:*:*", "matchCriteriaId": "5D887323-BBDD-41ED-82B8-66DE412666F5", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "B73766EB-FF3E-495E-B1C1-5D49A1569696", "versionStartIncluding": "1.11m", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5790F2E-5511-46F6-94E5-F3E1A2367662", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F3C096D-D510-46F4-B46A-A234CA630227", "versionStartIncluding": "1.04e", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "0EC0ACF4-C303-4EC0-A755-1F9AE4152DDB", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*", "matchCriteriaId": "407781DB-9AF9-4E3A-BF24-1787ADB33F42", "versionStartIncluding": "4.00a", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products." }, { "lang": "es", "value": "Vulnerabilidad de uso de entrada controlada externamente para seleccionar clases o c\u00f3digo (\"Reflexi\u00f3n insegura\") en Mitsubishi Electric Corporation EZSocket versiones 3.0 y posteriores, FR Configurator2 todas las versiones, GT Designer3 Versi\u00f3n1(GOT1000) todas las versiones, GT Designer3 Versi\u00f3n1(GOT2000) todas las versiones , GX Works2 versiones 1.11M y posteriores, GX Works3 todas las versiones, MELSOFT Navigator versiones 1.04E y posteriores, MT Works2 todas las versiones, MX Component versiones 4.00A y posteriores y MX OPC Server DA/UA todas las versiones permiten que un atacante remoto no autenticado ejecute un c\u00f3digo malicioso por RPC con una ruta a una librer\u00eda maliciosa mientras est\u00e1 conectado a los productos." } ], "id": "CVE-2023-6943", "lastModified": "2024-11-21T08:44:53.360", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-01-30T09:15:47.960", "references": [ { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU95103362" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU95103362" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf" } ], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-470" } ], "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-05-19 18:15
Modified
2024-11-21 05:03
Severity ?
8.3 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
mitsubishielectric | cpu_module_logging_configuration_tool | * | |
mitsubishielectric | cw_configurator | * | |
mitsubishielectric | data_transfer | * | |
mitsubishielectric | em_configurator | * | |
mitsubishielectric | ezsocket | * | |
mitsubishielectric | fr_configurator2 | * | |
mitsubishielectric | gt_designer3 | * | |
mitsubishielectric | gt_softgot1000 | * | |
mitsubishielectric | gt_softgot2000 | * | |
mitsubishielectric | gx_logviewer | * | |
mitsubishielectric | gx_works2 | * | |
mitsubishielectric | gx_works3 | * | |
mitsubishielectric | m_commdtm-hart | * | |
mitsubishielectric | m_commdtm-io-link | * | |
mitsubishielectric | melfa-works | * | |
mitsubishielectric | melsoft_fielddeviceconfigurator | * | |
mitsubishielectric | melsoft_navigator | * | |
mitsubishielectric | mh11_settingtool_version2 | * | |
mitsubishielectric | motorizer | * | |
mitsubishielectric | mr_configurator2 | * | |
mitsubishielectric | mt_works2 | * | |
mitsubishielectric | mx_component | * | |
mitsubishielectric | network_interface_board_cc-link_ver.2_utility | * | |
mitsubishielectric | network_interface_board_cc_ie_control_utility | * | |
mitsubishielectric | network_interface_board_cc_ie_field_utility | * | |
mitsubishielectric | network_interface_board_mneth_utility | * | |
mitsubishielectric | px_developer | * | |
mitsubishielectric | rt_toolbox2 | * | |
mitsubishielectric | rt_toolbox3 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "69A02BE6-633A-4A94-890C-586B3A42E19F", "versionEndExcluding": "1.106k", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "60875630-C0F2-434E-8D11-51B44F62CBA5", "versionEndExcluding": "1.011m", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE83331F-B795-410A-8510-351945025444", "versionEndExcluding": "3.41t", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:em_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0A01F0C-0B10-4906-9389-4D53AE3CD7FD", "versionEndExcluding": "1.015r", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9FFEA10-20FA-4B73-ACA5-AB7462820123", "versionEndExcluding": "4.6", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*", "matchCriteriaId": "2877EB49-8A69-426B-B7EB-87DEF3975562", "versionEndExcluding": "1.23z", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3393020-A6E6-431A-B572-E28948F6A970", "versionEndExcluding": "1.236w", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*", "matchCriteriaId": "3DC963D1-281A-48DE-B822-5254643C98E7", "versionEndExcluding": "3.245f", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*", "matchCriteriaId": "20E2D739-F982-4ED4-ADFB-505777CF9888", "versionEndExcluding": "1.236w", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*", "matchCriteriaId": "0809A627-EEC8-475E-997F-E3FAE2C39261", "versionEndExcluding": "1.106k", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F2B0AC1-1BEC-4D79-9995-527E3A770A66", "versionEndExcluding": "1.595v", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "matchCriteriaId": "80BF474D-E018-4612-93FD-F3A661C13A6D", "versionEndExcluding": "1.065t", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:*", "matchCriteriaId": "9C9ECB87-B07E-4E52-BF3F-8AD4AA03826B", "versionEndExcluding": "1.01b", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:*", "matchCriteriaId": "50FA8FAD-3DF4-453C-A55C-5F622DD76460", "versionEndExcluding": "1.04e", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:*", "matchCriteriaId": "ED888C84-4CD8-464A-A3A0-F623EB0F4920", "versionEndExcluding": "4.4", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_fielddeviceconfigurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE1E2976-38B4-4B1B-AC01-B3D8C26A1BB2", "versionEndExcluding": "1.04e", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*", "matchCriteriaId": "01D32795-831A-43D6-9F90-82A67F5E9081", "versionEndExcluding": "2.70y", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mh11_settingtool_version2:*:*:*:*:*:*:*:*", "matchCriteriaId": "7A6DE218-D030-4DDF-B504-B176DFE7662A", "versionEndExcluding": "2.003d", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:motorizer:*:*:*:*:*:*:*:*", "matchCriteriaId": "0FD24F8E-869B-413A-9BF1-555CF827F3C9", "versionEndExcluding": "1.010l", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*", "matchCriteriaId": "470498DC-4A30-4EC2-B9C7-B5348D2F1381", "versionEndExcluding": "1.106l", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "7926DBE1-335C-40E2-AD74-AE89DC9A0095", "versionEndExcluding": "1.160s", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCBBBA97-3C41-423F-8534-098070E49A97", "versionEndExcluding": "4.20w", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc-link_ver.2_utility:*:*:*:*:*:*:*:*", "matchCriteriaId": "3CFA2E01-1D66-40D6-8575-0E216376CC25", "versionEndExcluding": "1.24a", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_control_utility:*:*:*:*:*:*:*:*", "matchCriteriaId": "EBC15323-7468-4688-A9C2-01208B4849A4", "versionEndExcluding": "1.30g", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_field_utility:*:*:*:*:*:*:*:*", "matchCriteriaId": "F605A144-5A10-44C9-94DC-3B0D66E39431", "versionEndExcluding": "1.17t", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_mneth_utility:*:*:*:*:*:*:*:*", "matchCriteriaId": "54DBB417-5543-4AEB-9467-6197868C8C18", "versionEndExcluding": "35m", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:px_developer:*:*:*:*:*:*:*:*", "matchCriteriaId": "9987641F-1BD4-445A-86E4-778CFFFFEBD2", "versionEndExcluding": "1.53f", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:*", "matchCriteriaId": "A11F999D-CE97-49B6-9AF3-DD32D0E0779F", "versionEndExcluding": "3.73b", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*", "matchCriteriaId": "B03CE992-45F6-48EA-BE86-0041F0CDBEF7", "versionEndExcluding": "1.80j", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed." }, { "lang": "es", "value": "Una explotaci\u00f3n con \u00e9xito de esta vulnerabilidad para m\u00faltiples Productos Mitsubishi Electric Factory Automation Engineering Software de varias versiones podr\u00eda permitir a un atacante escalar privilegios y ejecutar programas maliciosos, lo que podr\u00eda causar una condici\u00f3n de denegaci\u00f3n de servicio, y permitir que la informaci\u00f3n sea divulgada, manipulada y/o destruida" } ], "id": "CVE-2020-14496", "lastModified": "2024-11-21T05:03:23.697", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.6, "impactScore": 6.0, "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-05-19T18:15:08.360", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-275" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }