Search criteria

9 vulnerabilities found for onewireless_network_wireless_device_manager_firmware by honeywell

FKIE_CVE-2022-4240

Vulnerability from fkie_nvd - Published: 2023-05-30 17:15 - Updated: 2024-11-21 07:34
Summary
Missing Authentication for Critical Function vulnerability in Honeywell OneWireless allows Authentication Bypass. This issue affects OneWireless version 322.1

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:honeywell:onewireless_network_wireless_device_manager_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "189C7318-C0AC-41A9-99AB-AB2BCB75E90B",
              "versionEndExcluding": "r322.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:honeywell:onewireless_network_wireless_device_manager:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "987B6E5F-C1B6-4764-A3B1-4AC7734B6D1D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Missing Authentication for Critical Function vulnerability in Honeywell OneWireless allows Authentication Bypass.\u00a0This issue affects OneWireless version 322.1"
    }
  ],
  "id": "CVE-2022-4240",
  "lastModified": "2024-11-21T07:34:51.163",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 2.5,
        "source": "psirt@honeywell.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-05-30T17:15:09.810",
  "references": [
    {
      "source": "psirt@honeywell.com",
      "tags": [
        "Product"
      ],
      "url": "https://process.honeywell.com/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Product"
      ],
      "url": "https://process.honeywell.com/"
    }
  ],
  "sourceIdentifier": "psirt@honeywell.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "psirt@honeywell.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2022-43485

Vulnerability from fkie_nvd - Published: 2023-05-30 17:15 - Updated: 2024-11-21 07:26
Summary
Use of Insufficiently Random Values in Honeywell OneWireless. This vulnerability may allow attacker to manipulate claims in client's JWT token. This issue affects OneWireless version 322.1

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:honeywell:onewireless_network_wireless_device_manager_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "189C7318-C0AC-41A9-99AB-AB2BCB75E90B",
              "versionEndExcluding": "r322.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:honeywell:onewireless_network_wireless_device_manager:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "987B6E5F-C1B6-4764-A3B1-4AC7734B6D1D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nUse of Insufficiently Random Values in Honeywell OneWireless. This vulnerability\u00a0may allow attacker to manipulate claims in client\u0027s JWT token.\u00a0This issue affects OneWireless version 322.1"
    }
  ],
  "id": "CVE-2022-43485",
  "lastModified": "2024-11-21T07:26:34.957",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.2,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 4.0,
        "source": "psirt@honeywell.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-05-30T17:15:09.573",
  "references": [
    {
      "source": "psirt@honeywell.com",
      "tags": [
        "Product"
      ],
      "url": "https://process.honeywell.com/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Product"
      ],
      "url": "https://process.honeywell.com/"
    }
  ],
  "sourceIdentifier": "psirt@honeywell.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-330"
        }
      ],
      "source": "psirt@honeywell.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-330"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2022-46361

Vulnerability from fkie_nvd - Published: 2023-05-30 17:15 - Updated: 2024-11-21 07:30
Summary
An attacker having physical access to WDM can plug USB device to gain access and execute unwanted commands. A malicious user could enter a system command along with a backup configuration, which could result in the execution of unwanted commands. This issue affects OneWireless all versions up to 322.1 and fixed in version 322.2.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:honeywell:onewireless_network_wireless_device_manager_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "189C7318-C0AC-41A9-99AB-AB2BCB75E90B",
              "versionEndExcluding": "r322.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:honeywell:onewireless_network_wireless_device_manager:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "987B6E5F-C1B6-4764-A3B1-4AC7734B6D1D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An attacker having physical access to WDM can plug USB device to gain access and execute unwanted commands. A malicious user could enter a system command along with a backup configuration, which could result in the execution of unwanted commands.\u00a0This issue affects OneWireless all versions up to 322.1 and fixed in version 322.2."
    }
  ],
  "id": "CVE-2022-46361",
  "lastModified": "2024-11-21T07:30:27.763",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "PHYSICAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.3,
        "impactScore": 6.0,
        "source": "psirt@honeywell.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "PHYSICAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-05-30T17:15:09.737",
  "references": [
    {
      "source": "psirt@honeywell.com",
      "tags": [
        "Product"
      ],
      "url": "https://process.honeywell.com/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Product"
      ],
      "url": "https://process.honeywell.com/"
    }
  ],
  "sourceIdentifier": "psirt@honeywell.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "psirt@honeywell.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2022-46361 (GCVE-0-2022-46361)

Vulnerability from cvelistv5 – Published: 2023-05-30 16:21 – Updated: 2025-01-09 21:26
VLAI?
Summary
An attacker having physical access to WDM can plug USB device to gain access and execute unwanted commands. A malicious user could enter a system command along with a backup configuration, which could result in the execution of unwanted commands. This issue affects OneWireless all versions up to 322.1 and fixed in version 322.2.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Honeywell OneWireless Affected: 322.1 , < 322.2 (patch 322.2)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:31:46.378Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://process.honeywell.com/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-46361",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-09T21:26:07.253611Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-09T21:26:17.690Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OneWireless",
          "vendor": "Honeywell",
          "versions": [
            {
              "lessThan": "322.2",
              "status": "affected",
              "version": "322.1",
              "versionType": "patch 322.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn attacker having physical access to WDM can plug USB device to gain access and execute unwanted commands. A malicious user could enter a system command along with a backup configuration, which could result in the execution of unwanted commands.\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eThis issue affects OneWireless all versions up to 322.1 and fixed in version 322.2.\u003c/span\u003e"
            }
          ],
          "value": "An attacker having physical access to WDM can plug USB device to gain access and execute unwanted commands. A malicious user could enter a system command along with a backup configuration, which could result in the execution of unwanted commands.\u00a0This issue affects OneWireless all versions up to 322.1 and fixed in version 322.2."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-646",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-646 Peripheral Footprinting"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-30T16:21:37.079Z",
        "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "shortName": "Honeywell"
      },
      "references": [
        {
          "url": "https://process.honeywell.com/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Physical access to the WDM enables use of USB device to gain access to the WDM",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
    "assignerShortName": "Honeywell",
    "cveId": "CVE-2022-46361",
    "datePublished": "2023-05-30T16:21:37.079Z",
    "dateReserved": "2022-11-30T20:26:18.635Z",
    "dateUpdated": "2025-01-09T21:26:17.690Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-43485 (GCVE-0-2022-43485)

Vulnerability from cvelistv5 – Published: 2023-05-30 16:19 – Updated: 2025-01-09 21:27
VLAI?
Summary
Use of Insufficiently Random Values in Honeywell OneWireless. This vulnerability may allow attacker to manipulate claims in client's JWT token. This issue affects OneWireless version 322.1
CWE
  • CWE-330 - Use of Insufficiently Random Values
Assigner
References
Impacted products
Vendor Product Version
Honeywell OneWireless Affected: 322.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:32:58.741Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://process.honeywell.com/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43485",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-09T21:26:48.252024Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-09T21:27:01.369Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OneWireless",
          "vendor": "Honeywell",
          "versions": [
            {
              "status": "affected",
              "version": "322.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUse of Insufficiently Random Values in Honeywell OneWireless. This vulnerability\u0026nbsp;may allow attacker to manipulate claims in client\u0027s JWT token.\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eThis issue affects OneWireless version 322.1\u003c/span\u003e"
            }
          ],
          "value": "\nUse of Insufficiently Random Values in Honeywell OneWireless. This vulnerability\u00a0may allow attacker to manipulate claims in client\u0027s JWT token.\u00a0This issue affects OneWireless version 322.1"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-39",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-39 Manipulating Opaque Client-based Data Tokens"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-330",
              "description": "CWE-330: Use of Insufficiently Random Values",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-30T16:19:24.146Z",
        "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "shortName": "Honeywell"
      },
      "references": [
        {
          "url": "https://process.honeywell.com/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Insecure random number used for generating keys for signing Jwt tokens",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
    "assignerShortName": "Honeywell",
    "cveId": "CVE-2022-43485",
    "datePublished": "2023-05-30T16:19:24.146Z",
    "dateReserved": "2022-11-30T20:26:18.642Z",
    "dateUpdated": "2025-01-09T21:27:01.369Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-4240 (GCVE-0-2022-4240)

Vulnerability from cvelistv5 – Published: 2023-05-30 16:15 – Updated: 2025-01-09 21:27
VLAI?
Summary
Missing Authentication for Critical Function vulnerability in Honeywell OneWireless allows Authentication Bypass. This issue affects OneWireless version 322.1
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
Honeywell OneWireless Affected: 322.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:34:49.828Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://process.honeywell.com/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-4240",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-09T21:27:17.031575Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-09T21:27:24.395Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OneWireless",
          "vendor": "Honeywell",
          "versions": [
            {
              "status": "affected",
              "version": "322.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Missing Authentication for Critical Function vulnerability in Honeywell OneWireless allows Authentication Bypass.\u0026nbsp;\u003cspan style=\"background-color: var(--wht);\"\u003eThis issue affects OneWireless version 322.1\u003c/span\u003e"
            }
          ],
          "value": "Missing Authentication for Critical Function vulnerability in Honeywell OneWireless allows Authentication Bypass.\u00a0This issue affects OneWireless version 322.1"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-30T16:15:50.508Z",
        "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "shortName": "Honeywell"
      },
      "references": [
        {
          "url": "https://process.honeywell.com/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Unauthenticated API allowing an attacker to obtain the information about network resources",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
    "assignerShortName": "Honeywell",
    "cveId": "CVE-2022-4240",
    "datePublished": "2023-05-30T16:15:50.508Z",
    "dateReserved": "2022-11-30T20:30:03.280Z",
    "dateUpdated": "2025-01-09T21:27:24.395Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-46361 (GCVE-0-2022-46361)

Vulnerability from nvd – Published: 2023-05-30 16:21 – Updated: 2025-01-09 21:26
VLAI?
Summary
An attacker having physical access to WDM can plug USB device to gain access and execute unwanted commands. A malicious user could enter a system command along with a backup configuration, which could result in the execution of unwanted commands. This issue affects OneWireless all versions up to 322.1 and fixed in version 322.2.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Honeywell OneWireless Affected: 322.1 , < 322.2 (patch 322.2)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:31:46.378Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://process.honeywell.com/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-46361",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-09T21:26:07.253611Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-09T21:26:17.690Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OneWireless",
          "vendor": "Honeywell",
          "versions": [
            {
              "lessThan": "322.2",
              "status": "affected",
              "version": "322.1",
              "versionType": "patch 322.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn attacker having physical access to WDM can plug USB device to gain access and execute unwanted commands. A malicious user could enter a system command along with a backup configuration, which could result in the execution of unwanted commands.\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eThis issue affects OneWireless all versions up to 322.1 and fixed in version 322.2.\u003c/span\u003e"
            }
          ],
          "value": "An attacker having physical access to WDM can plug USB device to gain access and execute unwanted commands. A malicious user could enter a system command along with a backup configuration, which could result in the execution of unwanted commands.\u00a0This issue affects OneWireless all versions up to 322.1 and fixed in version 322.2."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-646",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-646 Peripheral Footprinting"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-30T16:21:37.079Z",
        "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "shortName": "Honeywell"
      },
      "references": [
        {
          "url": "https://process.honeywell.com/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Physical access to the WDM enables use of USB device to gain access to the WDM",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
    "assignerShortName": "Honeywell",
    "cveId": "CVE-2022-46361",
    "datePublished": "2023-05-30T16:21:37.079Z",
    "dateReserved": "2022-11-30T20:26:18.635Z",
    "dateUpdated": "2025-01-09T21:26:17.690Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-43485 (GCVE-0-2022-43485)

Vulnerability from nvd – Published: 2023-05-30 16:19 – Updated: 2025-01-09 21:27
VLAI?
Summary
Use of Insufficiently Random Values in Honeywell OneWireless. This vulnerability may allow attacker to manipulate claims in client's JWT token. This issue affects OneWireless version 322.1
CWE
  • CWE-330 - Use of Insufficiently Random Values
Assigner
References
Impacted products
Vendor Product Version
Honeywell OneWireless Affected: 322.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:32:58.741Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://process.honeywell.com/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43485",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-09T21:26:48.252024Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-09T21:27:01.369Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OneWireless",
          "vendor": "Honeywell",
          "versions": [
            {
              "status": "affected",
              "version": "322.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUse of Insufficiently Random Values in Honeywell OneWireless. This vulnerability\u0026nbsp;may allow attacker to manipulate claims in client\u0027s JWT token.\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eThis issue affects OneWireless version 322.1\u003c/span\u003e"
            }
          ],
          "value": "\nUse of Insufficiently Random Values in Honeywell OneWireless. This vulnerability\u00a0may allow attacker to manipulate claims in client\u0027s JWT token.\u00a0This issue affects OneWireless version 322.1"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-39",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-39 Manipulating Opaque Client-based Data Tokens"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-330",
              "description": "CWE-330: Use of Insufficiently Random Values",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-30T16:19:24.146Z",
        "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "shortName": "Honeywell"
      },
      "references": [
        {
          "url": "https://process.honeywell.com/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Insecure random number used for generating keys for signing Jwt tokens",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
    "assignerShortName": "Honeywell",
    "cveId": "CVE-2022-43485",
    "datePublished": "2023-05-30T16:19:24.146Z",
    "dateReserved": "2022-11-30T20:26:18.642Z",
    "dateUpdated": "2025-01-09T21:27:01.369Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-4240 (GCVE-0-2022-4240)

Vulnerability from nvd – Published: 2023-05-30 16:15 – Updated: 2025-01-09 21:27
VLAI?
Summary
Missing Authentication for Critical Function vulnerability in Honeywell OneWireless allows Authentication Bypass. This issue affects OneWireless version 322.1
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
Honeywell OneWireless Affected: 322.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:34:49.828Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://process.honeywell.com/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-4240",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-09T21:27:17.031575Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-09T21:27:24.395Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OneWireless",
          "vendor": "Honeywell",
          "versions": [
            {
              "status": "affected",
              "version": "322.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Missing Authentication for Critical Function vulnerability in Honeywell OneWireless allows Authentication Bypass.\u0026nbsp;\u003cspan style=\"background-color: var(--wht);\"\u003eThis issue affects OneWireless version 322.1\u003c/span\u003e"
            }
          ],
          "value": "Missing Authentication for Critical Function vulnerability in Honeywell OneWireless allows Authentication Bypass.\u00a0This issue affects OneWireless version 322.1"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-30T16:15:50.508Z",
        "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "shortName": "Honeywell"
      },
      "references": [
        {
          "url": "https://process.honeywell.com/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Unauthenticated API allowing an attacker to obtain the information about network resources",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
    "assignerShortName": "Honeywell",
    "cveId": "CVE-2022-4240",
    "datePublished": "2023-05-30T16:15:50.508Z",
    "dateReserved": "2022-11-30T20:30:03.280Z",
    "dateUpdated": "2025-01-09T21:27:24.395Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}