All the vulnerabilites related to siemens - pss_odms
Vulnerability from fkie_nvd
Published
2021-11-14 21:15
Modified
2024-11-21 06:25
Severity ?
Summary
In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
wibu | codemeter_runtime | * | |
microsoft | windows | - | |
siemens | pss_cape | 14 | |
siemens | pss_e | * | |
siemens | pss_e | * | |
siemens | pss_odms | * | |
siemens | sicam_230 | * | |
siemens | simatic_information_server | * | |
siemens | simatic_information_server | 2019 | |
siemens | simatic_information_server | 2019 | |
siemens | simatic_pcs_neo | * | |
siemens | simatic_process_historian | * | |
siemens | simatic_wincc_oa | * | |
siemens | simit | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:wibu:codemeter_runtime:*:*:*:*:*:*:*:*", "matchCriteriaId": "C8B1884B-18F5-4B92-B83F-C756725FDAB9", "versionEndExcluding": "7.30a", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:pss_cape:14:*:*:*:*:*:*:*", "matchCriteriaId": "76414178-E1E6-40A5-9DD2-FBAD698624C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:pss_e:*:*:*:*:*:*:*:*", "matchCriteriaId": "E01D2F88-8820-49E6-8865-3E20AB63289E", "versionEndExcluding": "34.9.1", "versionStartIncluding": "34.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:pss_e:*:*:*:*:*:*:*:*", "matchCriteriaId": "F42F3EBF-41A9-4F3B-BEED-2954B350E0FA", "versionEndExcluding": "35.3.2", "versionStartIncluding": "35.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:pss_odms:*:*:*:*:*:*:*:*", "matchCriteriaId": "8707B418-2D99-4303-8102-316081B722D4", "versionEndExcluding": "12.2.6.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sicam_230:*:*:*:*:*:*:*:*", "matchCriteriaId": "312E7EA5-61A8-4439-A9E0-87522E8DD141", "versionEndExcluding": "8.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_information_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FD2B7BE-73CA-4974-A61C-3E97FE5A2F7F", "versionEndExcluding": "2019", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_information_server:2019:-:*:*:*:*:*:*", "matchCriteriaId": "4FA3A37A-6A43-42E1-80BF-7FF346D2F253", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_information_server:2019:sp1:*:*:*:*:*:*", "matchCriteriaId": "4BB95C8C-188D-430F-9D59-7F5E1832A0A5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "D61D4B81-7F51-49BE-83DD-D2C28D23B0EA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_process_historian:*:*:*:*:*:*:*:*", "matchCriteriaId": "9A9C8C40-ABBD-496C-BF0B-24098B96D029", "versionEndIncluding": "2019", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_oa:*:*:*:*:*:*:*:*", "matchCriteriaId": "52504DDF-990A-419B-BEAF-E02B4403BBBA", "versionEndIncluding": "3.18", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simit:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE96110F-4874-42C5-A891-FD9022FE7803", "versionEndIncluding": "10.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions." }, { "lang": "es", "value": "En WIBU CodeMeter Runtime versiones anteriores a 7.30a, la creaci\u00f3n de un enlace simb\u00f3lico CmDongles dise\u00f1ado sobrescribir\u00e1 el archivo enlazado sin comprobar los permisos" } ], "id": "CVE-2021-41057", "lastModified": "2024-11-21T06:25:21.627", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 3.6, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:N/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-11-14T21:15:07.797", "references": [ { "source": "cve@mitre.org", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.wibu.com/us/support/security-advisories.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.wibu.com/us/support/security-advisories.html" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-59" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2021-41057
Vulnerability from cvelistv5
Published
2021-11-14 20:21
Modified
2024-08-04 02:59
Severity ?
EPSS score ?
Summary
In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions.
References
▼ | URL | Tags |
---|---|---|
https://www.wibu.com/us/support/security-advisories.html | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf | x_refsource_CONFIRM | |
https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T02:59:31.383Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.wibu.com/us/support/security-advisories.html" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-11-14T20:21:30", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.wibu.com/us/support/security-advisories.html" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-41057", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.wibu.com/us/support/security-advisories.html", "refsource": "MISC", "url": "https://www.wibu.com/us/support/security-advisories.html" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf" }, { "name": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf", "refsource": "CONFIRM", "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-41057", "datePublished": "2021-11-14T20:21:30", "dateReserved": "2021-09-13T00:00:00", "dateUpdated": "2024-08-04T02:59:31.383Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }